Peugeot 208 heater AC blower motor not working

Sdílet
Vložit
  • čas přidán 29. 04. 2021
  • Peugeot 208 no heater fan
    Subscribe and get more great videos weekly
    / @rmautodiag
    Picoscope 2 channel scope
    amzn.to/2C8MeYt
    Picoscope 4 channel scope
    amzn.to/3gvFWRB
    Uni-T multimeter
    amzn.to/3bSDT7J
    decade/resistance box
    amzn.to/3jWds5u
    amzn.to/326vrjj
    rmautodiag.com
    home
    / rmautodiag
    Disclaimer:
    Due to factors beyond the control of RMAutodiag, it cannot guarantee against unauthorized modifications of this information, or improper use of this information. RMAutodiag assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. RMAutodiag recommends safe practices when working with power tools, automotive lifts, lifting tools, jack stands, electrical equipment, blunt instruments, chemicals, lubricants, or any other tools or equipment seen or implied in this video. Due to factors beyond the control of RMAutodiag, no information contained in this video shall create any express or implied warranty or guarantee of any particular result. Any injury, damage or loss that may result from improper use of these tools, equipment, or the information contained.
    As an Amazon associate, i earn from qualifying purchaces.
  • Auta a dopravní prostředky

Komentáře • 50

  • @sharonwood6918
    @sharonwood6918 Před rokem

    Thank you very much for your video my husband fixed my heating system..can't imagine the cost taking it to a dealer 👌👏👏

  • @philippepeta4335
    @philippepeta4335 Před 3 lety +4

    Excellent video, got the fan back to life ! Thanx to you, it saved me quite a lot of money. Peugeot main dealer already wanted to bill 117€ for the diag. I can easyly imagine the final result...
    All the best from France
    Take care !

    • @rmautodiag
      @rmautodiag  Před 3 lety

      Glad you got it fixed, thanks for the comment

  • @antonydavies3777
    @antonydavies3777 Před 9 měsíci

    Thanks for video it happened on my daughters and thanx to your video saved me loads of time and got me loads of browny points with the daughter lol cheers mate 👍

  • @pistolpete5189
    @pistolpete5189 Před 2 lety +5

    Thanks for the video, I just fixed mine in under 10 minutes instead of 2 hours pulling my hair out.. working perfectly 👍👍

  • @gomla8187
    @gomla8187 Před 3 lety +1

    My PUG 2008 had the same issue. Thanks for uploading. This saved me a lot.

  • @steveleste2039
    @steveleste2039 Před rokem

    Thanks.... Same problem with a Peugeot 2008-year 2016. Great job, you same me a lot of times. Keep it up !!!....😊👍👍

  • @taewhankim1617
    @taewhankim1617 Před rokem +1

    영상을 올려 주셔서 감사합니다. 영상 덕분에 쉽게 고쳤습니다.👍

  • @weist701
    @weist701 Před rokem

    Thank you for your advice!

  • @BaronRosenhein
    @BaronRosenhein Před 2 lety +1

    Excellent video. Exactly the same problem. No contact on the positive terminal (melted connector) coming from the battery to the resistor feeding the fan.

  • @NotMoreGames
    @NotMoreGames Před 2 lety +1

    The blower on my 2014 Peugeot 2008 was intermittent and may come back alive again by just jiggling that faulty connector block. Suspected it was melted inside as couldn’t disconnect without snipping the wires. Replaced it with a generic electric wire connector block and it works fine - common fault for many Peugeots including 208 and 2008.

  • @user-dv6bs1fl3m
    @user-dv6bs1fl3m Před rokem

    Dzięki temu filmowi naprawiłem wentylator w moim aucie 😊

  • @naomimcclean3544
    @naomimcclean3544 Před 2 lety +2

    Thanks.. same problem in my 208 fixed because of this video..

    • @rmautodiag
      @rmautodiag  Před 2 lety +1

      Glad it helped, thanks for the comment.

    • @naomimcclean3544
      @naomimcclean3544 Před 2 lety +1

      @@rmautodiag this video has saved so much time looking for problem and money..

  • @user-ft4yd3ye9b
    @user-ft4yd3ye9b Před rokem

    Thanks for the video. Hello from Ukraine. Дякую.

  • @duanedownton7155
    @duanedownton7155 Před 3 lety +2

    I had the same outcome, faulty plug👍 thanks

    • @rmautodiag
      @rmautodiag  Před 3 lety

      Glad you got it sorted, thanks for the comment 👍

  • @daniellebott3292
    @daniellebott3292 Před 2 lety +2

    Does anyone know what the black plug thing is called?

  • @daletabbinor4876
    @daletabbinor4876 Před 2 lety +1

    Hi what can I use to connect the wires back together ?

  • @marinmohoric43
    @marinmohoric43 Před 2 lety

    is it the same for manual ac?

  • @kithedley7045
    @kithedley7045 Před 3 lety

    Hey could you tell me where to source a replacement plug please?

  • @marjancfarku6372
    @marjancfarku6372 Před 11 měsíci

    Hi. I am having the same issue with the connector that is melted. Can you tell me pls what type of connector you used because I'm not finding the right one? Thank you

  • @md6732
    @md6732 Před rokem

    I have an issue where mine is stuck on or open. As soon as you start the engine its full blast, the controls still work to change the direction etc but you cannot turn it off. Any ideas?

  • @aaronsuch7563
    @aaronsuch7563 Před 2 lety +1

    For those wondering I think if you search "peugeot electrical multipurpose 2 pin connector" I think that's the one! I know it looks slightly different but think it's the same

  • @xaviermathieu6802
    @xaviermathieu6802 Před 2 lety

    Thanks for the video. Would you have the reference of the plug? I would like to order it to be able to change it myself :)

    • @johnl6973
      @johnl6973 Před 2 lety

      You don't have to order a plug if you need it fast... I used crimp connectors on mine. If you really want a connector, it's not a make/model specific part. Just get one that's rated for the volt/amps going through

    • @daletabbinor4876
      @daletabbinor4876 Před 2 lety

      @@johnl6973 which crimp connectors did u use ?

    • @chrispy2117
      @chrispy2117 Před rokem

      Did you ever find out if there was a reference?

  • @Mark32986
    @Mark32986 Před 3 lety +1

    Did you manage to source another connecter for that? Can’t find one anywhere

    • @chrispy2117
      @chrispy2117 Před rokem

      Any chance you found one?

    • @Mark32986
      @Mark32986 Před rokem +1

      @@chrispy2117 nah just used a wago, it’s not set my car of fire… yet

    • @scottmurray8483
      @scottmurray8483 Před 6 měsíci

      Did u use a 4 way wago or 2 x 2ways? ​@@Mark32986

  • @nathangibbons9270
    @nathangibbons9270 Před rokem

    Any idea where I can get the connector from online? or a part suitable to use as a jumper?

    • @nickclark4372
      @nickclark4372 Před rokem

      Hi Nathan, did you find a solution to this? Looking for a part to use 😬

    • @chrispy2117
      @chrispy2117 Před rokem

      Same question as @nickclark4372, any chance you've found anything?

  • @pgriff44
    @pgriff44 Před 2 lety

    Any idea if it is not this plug. I have 14V on both sides of the connector

    • @hf9168
      @hf9168 Před rokem

      I have the same problem as you. 14v on both sides of the connector but still the motor does not work. Have you found out what was the problem in your case? Thanks

    • @MH-sf3oj
      @MH-sf3oj Před rokem

      @HF 916 Hey there, did you manage to find the issue and get it sorted?

  • @claremadgin
    @claremadgin Před 3 lety +2

    👍

  • @nedas7983
    @nedas7983 Před 3 lety +2

    Where are you based?

    • @rmautodiag
      @rmautodiag  Před 3 lety

      Somerset UK

    • @nedas7983
      @nedas7983 Před 3 lety +1

      @@rmautodiag oh damn I’m London, cold air is coming out and hot air is as well but there seems to be no pressure, like you can just about feel it next to the fans, does this mean the blower is broken or the connection for it?

    • @rmautodiag
      @rmautodiag  Před 3 lety

      @@nedas7983 I would check this connection first