Sir 6 saal se kaam mebi kr raha hu ac ka lekin m video dekh kr samjh gya tha yehbi problem ho sakti h lekin aap jaisi video CZcams pe koi nhi banata h ❤❤ nice work
Bahut hi Achcha Se Samghaye Thanks Sir Sir kya Second Hand Rotate Compresar Lagate Samay Aqumletar Me Jo Filtar hota haa Usako Todana Padata haa Kya Auger Todna Padta haa To Kyu
What if there is EEV instead of Capillary & then compressor is getting heated with noise, Pulling ~10Amps (in a Daikin Inverter AC 1.5 ton with rated Amps = 5.9Amps). Not much cooling in indoor & compressor trips every 5-8 mins. F3 error shows in indoor. Gas properly recharged but problem remained. Running pressure is 80-90psi & standing pressure is ~250psi.
mera invertor split ac h jo unit jyada le reha abhi 4 month hue h purchase kiye hue or 28 degree m b bohot cooling krta h or compressor auto cut b nehi hota h, kya kre ya kya problem h
Plz reply .. sir 1.5 ton inverter split ac .. 26 pe use krne pe 6amp se 2ampere tak load aajta tha ..lekin ab 5 ampere he reh raha ha 2-3 din se kya problm ho skta ha sir ..?
Sir Mera ac Sumsung digital invetar hai gas r410a hai jab m ac ko auto mode par calata hu to ac 5 mint bad tirip kar jata hai or jab 26 ya 28 digri par calata hu to kabhi tiri karta hai or kabhi nhi karta pelese solution
Sir aap kaha job karte h main bhi karna chahta hun mujhe ac ka kaam aata h lekin nhi kr raha kuchh aur karta hun aur achhi country mein company me job chahiye please help me.
Sir mai bhi technician hu.. Or mai apko btadu ki.. Mai automatic washing machine. Microwave. Dishwasher. Drayer. AC. Fridge. Ka technician hu. Mujhko bhi saudi ana hai to apse ye puchna hai in sb ki job requirements nikalti hai apki company
Q ki sir mai sbhi chez repair krta hu to iski konsi vacancy nikalti hai.... Mujhko sirf Refreging k kam mai hi ana hoga ya fr dusri koi vacancy hoti hai in sbhi kam. Ki
Sir 10.50 kW cooling capacity 3 ton signal phase ac compressor on hote hi 65 amp le raha hai 2 second me compressor trip ho raha hai kya kya reasons ho sakte hai pls jaldi bataiye ac hold kar rakha hai samajh me nahi a raha compressor stuck ho gaya hai ya koi aur falt hai
Bhai Mera window AC h godrej h ka 1.5 ton ka comparessor bar bar trip ho jata h aur stablizer input voltage 255 watt show ho rha h Maine new stabizer liya h phir bhi ac compressor not working please sir reply
Thanks sir itna sammsn dene ke liye is video se aur bhai logo ka bhala ho jaye sir ki wajah sabka bhala ho great sir
Thank you ser very nice video
Thanku Bhai app bahut acha samjha rehe nhe
Sir 6 saal se kaam mebi kr raha hu ac ka lekin m video dekh kr samjh gya tha yehbi problem ho sakti h lekin aap jaisi video CZcams pe koi nhi banata h ❤❤ nice work
Aap kaha kam karte ho
Thank u sir very good nolege
Again thanks from pakistan
Sir aise hi live problem ko dikhakar solution bataye
Thank you sir
Very nice 👍
R/32 , 1.5 ton ac me aisa video plz banaeye..
ampire perfect check karne ke liye kitane time Tak wait karna padega...
Bhai app bahut acha video bnate hai lekin video's thoda chota bnao
Bhut achi knowledge di aapne
Aap ne solve kardiya
Thank you sir ji,keep making videos.
Back pressure aur amp. Dono high hy to kya karna chahiye r 22
Bahut hi Achcha Se Samghaye
Thanks Sir
Sir kya Second Hand Rotate Compresar Lagate Samay Aqumletar Me Jo Filtar hota haa Usako Todana Padata haa Kya
Auger Todna Padta haa To Kyu
Okey sir very good sir
Good job sir..........
Verry good
Wao kya good job
yes sar very good job sar
Thanks brother
Very nice 👍
Shukriya bhai
Bahut badhiya 👌
What if there is EEV instead of Capillary & then compressor is getting heated with noise, Pulling ~10Amps (in a Daikin Inverter AC 1.5 ton with rated Amps = 5.9Amps). Not much cooling in indoor & compressor trips every 5-8 mins. F3 error shows in indoor. Gas properly recharged but problem remained. Running pressure is 80-90psi & standing pressure is ~250psi.
nice video nice
mera invertor split ac h jo unit jyada le reha abhi 4 month hue h purchase kiye hue or 28 degree m b bohot cooling krta h or compressor auto cut b nehi hota h, kya kre ya kya problem h
Well done bro, good job
Good sir
Ceplari chok h,ya cepisiter,condesun chok fan moter speed com
Sir live Aana suru kijie
shukriya sir
from Delhi
Pcb आउटडोर ki kaise chek kre एक वीडियो बनाकर भेजिए प्लीज
Plz reply .. sir 1.5 ton inverter split ac .. 26 pe use krne pe 6amp se 2ampere tak load aajta tha ..lekin ab 5 ampere he reh raha ha 2-3 din se kya problm ho skta ha sir ..?
Naya 2tone ka ac. compreshor amp.jada kintu le raha hai jad ki R22 ka gash Ranning prashor20 PSI hai
Sir samjhna bhut ashan tha
Thanks
Good morning sir
Sir Mera ac Sumsung digital invetar hai gas r410a hai jab m ac ko auto mode par calata hu to ac 5 mint bad tirip kar jata hai or jab 26 ya 28 digri par calata hu to kabhi tiri karta hai or kabhi nhi karta pelese solution
Good video
Please reply this problem
Sir aap kaha job karte h main bhi karna chahta hun mujhe ac ka kaam aata h lekin nhi kr raha kuchh aur karta hun aur achhi country mein company me job chahiye please help me.
Spit ac inverter modal ac kesai chake karte h
Volteg drop kyu karta h sir
Hello sir
Siirr Inverter Ac Ka Commpressure Diirect Start Krne Kii Viideo Vii Upload Kar DiiJiiye Plss ❤️
Ok
Bristol compresser new hai lakin direct connection nahi chal raha hai Batavia kya kare
Capsiter ke sath connection kariye
Thanks you
Welcome
Bro ek split ac hai lg ka 2amp le raha he our suction line pr ice aa rahi he
Mujhe aap se presnali paid jankari chahiye
Bilkul sahi
Sir tecumshah 1.5 ton reci compressor me r22 gas ka exact pressure kitnna hona chaiye
LG floor standing unit error code ch54 what reason explain boy
Compressor starting main 35 ampere leta hain phir 6 ampere per chalta hain. Steplizer ka fuse bhi uda deta hain .kya issue hain
Kya answer mila
Sir g app 2the point bat ni krty bhech m fozol k baty Bhoot krjaty hooo...😊
i tan ho ya 2tan ka ho
Sir split AC inverter Hie Ampere lay rha h Haire Campni ka Kya problame h
Sir kaise pahchane kitne number ki capillary lagi h AC m please sir batao
Bhae me yahi samasya me fasa tha
Sir compressor ka pampinh preshar bhi fell ho sakta hai kiu ki hamare satt Aisha ho chuka hai
Sir aap mudde ke bat pe jaldi aaya kijiye plz
Ok bro
Amp jayeda lene par bill bhi jayeda aata hai kya please reply @@AMRESH11TECH
Bro agr 1 ton ka ac still 9.5 ampairs ly rha hai or cooling b bahter nahi ho rai to uski kya wja hai
Hi sir kaun company me kaam karte ho sir
Mujhe sikhana hai kya karu
Kaise pata kare ki capillary kitne number ka hai
R22 gas sistm Dali par Puri gas vacuum ma chli g
Capillary different hone par kya problem ho sakta hai bhaiya
Same yahe problem hn Mari AC ka sath be 😔
Kon sa pipe jyda cool hota hota h mota ye patla
Sir aap live aaiye
Mai live me aapse question puchunga sir aap live rat 9:30 ke bad aana
Indoor band karne k baad outdoor chalu ho jata h Or outdoor trip kar jata h thodi der me fir kab uthega koi time ni iska kya karan h
Sir compressor full load pe chal rha hai, aur full current le rha hai ,but tripp nhi ho rha hai
How are you boss
Good
Sir mera ak problem ha
Compreser direct start karna sa wire ma smoking araha ha
Condensor 2-3baar change kiya hai. Plz guide immediately
Sir Mera ac nahi ho raha hai
Konse desh mai job krte ko kis jagah pr krte.... Btana zarur sir
Riyadh ( Saudi Arabia )
Sir mai bhi technician hu.. Or mai apko btadu ki.. Mai automatic washing machine. Microwave. Dishwasher. Drayer. AC. Fridge. Ka technician hu. Mujhko bhi saudi ana hai to apse ye puchna hai in sb ki job requirements nikalti hai apki company
I m big fan of you ❤
Q ki sir mai sbhi chez repair krta hu to iski konsi vacancy nikalti hai.... Mujhko sirf Refreging k kam mai hi ana hoga ya fr dusri koi vacancy hoti hai in sbhi kam. Ki
Or sr dusri bat ye ki. Mai apki company Mai aa skta hu ya nhi iski vacancy kb nikalti hai sir
Bhai Mera Ac 3.8 amr Le rha h or cooling km h or fan bhi full pr silo h
Gas leakeage hai
Sir 10.50 kW cooling capacity 3 ton signal phase ac compressor on hote hi 65 amp le raha hai 2 second me compressor trip ho raha hai kya kya reasons ho sakte hai pls jaldi bataiye ac hold kar rakha hai samajh me nahi a raha compressor stuck ho gaya hai ya koi aur falt hai
Bhai Mera window AC h godrej h ka 1.5 ton ka comparessor bar bar trip ho jata h aur stablizer input voltage 255 watt show ho rha h Maine new stabizer liya h phir bhi ac compressor not working please sir reply
please jaldi guide kare meharbani hogi
Kya jaankari chahte hain
@@AMRESH11TECH Sir good morning pls guide me
Sir comment me sab likha hai
Whatsapp me massage Kya hu lekin Avhi Tak jawab nahi diye h
1 ton
1.5 ton me caplery konti no ki lagti h please bataye
Bhai 0.60 caplari size
Sar aap kahan per job karte hain kis company mein
Sr ap job kaha krte ho
Riyadh ( Saudi Arabia )
Ac mpr adik liraha hay
Ya live kro bhaiii
Bhai kahan se ho aur konsi company me JOB karte ho
Sir mera window ac 1.5 lg hai or uska compressor on hote he 18 amp load le raha hai kya problam ho sakti hai
Compresser kharab hai
47se age nahi bad Raha h fain bas chal raha h
Low ampere le raha h.. package unit h 18ton what problem?
Mein ye problem face kar raha hun Bhai kya compressor kharab ho sakta hein . Reply kare
Ha
Samsung pc04 error btawo
Voltage check kariye
@@AMRESH11TECH ok
Bhai split AC me condonsor me bahut jyada garam ho Raha An compressor trip ho jaraha h Kya problem h
Compressor heating Ka video hai, dekhiye
No exepri
Bai hamare tora halp koro
Kaha hai link
sir fiting ka dalo plzz
Ok
@@AMRESH11TECH thanks 😊 you are great sir
@@AMRESH11TECH thanks 😊 you are great sir
No de do bro apna
Bonk kuty bonk Samaj to a ni Rai Kya Keh rhy ho lakin bonk kuty bonk
comprassor to on ho rha h
mgr fan nhi on rha h kya fan aur comprssor sat on hote h ya fan pehle on hota h sr
Thanks sir very useful information
Apna no. De do bhai
Bhai apka nambar mil sakta hai
+918840474861
Chaman chu😂
Sir aap ka number. chahiye.please sir reply