    Hi, it is really helpful. Thanks for this presentation. I would appreciate if you could answer one of my question. I find in pipeline (underground) facility design, sometimes Isolation kits are used and sometimes not in the riser site. When do we need it and when not? Thanks for your clarification. Riton

    • @cck0728
      @cck0728 Před 6 lety

      Isolation kits are normally used to prevent the cathodic protection current leaking to your critical equipment such as flow meters etc. The flow meter (specially electro magnetic) reading will deviate if CP current start passing through it.