RING CIRCUIT FAULT FINDING - FINDING BREAKS IN THE CABLE - TESTING METHODS - HOW TO TEST THE CIRCUIT

Sdílet
Vložit
  • čas přidán 9. 06. 2023
  • In this LearnElectrics video we look at ways of finding breaks or damaged wiring in a ring circuit. The methods you might employ if a periodic inspection of a premises has identified problems with the circuit. If you’re new to the trade or perhaps if testing is now part of your job description, this video will help.
    We’ve had lots of questions posted …
    How do I test for broken wires in a ring circuit?
    Or … During an Inspection and Test there is no continuity on some of the end to end tests.
    How do I find the problem?
    What readings should I get at the sockets and how can the resistance readings help me to find the problem?
    And lots more, including how to test without a wander lead
    This is video number 204 and to view all our videos type in LearnElectrics all one word into the CZcams search bar.
    Visit our CZcams channel where we have many more videos on a wide range of electrical topics.

Komentáře • 71

  • @matt4436
    @matt4436 Před rokem +7

    Thumbs up first then start watching

  • @koonholee3056
    @koonholee3056 Před rokem +4

    My favorite electrical knowledge channel, never disappoint you

  • @Crystalpal1978
    @Crystalpal1978 Před rokem +3

    I have my am2 coming up, thus channel is very helpful 👌

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      If it helps, great. Try and revise a little each day, rather than too much the night before. Good luck. Dave.

  • @mikegmarshall
    @mikegmarshall Před rokem +4

    Great video thanks - I use the same method. I use the continuity buzzer but same result - been a spark since 1980 but I could listen to you all day cheers Dave keep em coming 👍

  • @gbelectricks
    @gbelectricks Před rokem +6

    Great video Dave, I like to use the method you described here. The only additional thing I do is put a piece of insulation tape on top of the socket with the measured resistance value written on it. I also then go back to the board and link the other end, then use a different colour tape and start writing resistance values on socket fronts. Then if the ring isn’t logically wired, at least you can start removing the two sockets with the “highest resistances” first. I find it very effective especially if you’ve no idea how the ring has been previously wired.

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +3

      What an excellent method. Live and learn every day. Thanks for the tips, definitely worth investigating. Dave.

  • @no_short_circuit
    @no_short_circuit Před rokem

    When the route of the ring isn't quite straigtforward, Dave's video TRACING SOCKET CIRCUITS and other ELECTRICAL CIRCUITS is very useful

  • @sunshine3187
    @sunshine3187 Před rokem +1

    The one I've been waiting for, cheers Dave. Always excellently explained.

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      Glad to help, thanks for watching. next weeks is about breaks in the neutral. Thanks for the support. Dave.

  • @alinili5569
    @alinili5569 Před 8 měsíci

    Hi Dave I be been registered Approved Contractor for 13 years I found your videos very helpful and the best available I listen your video when I can during the work or at home You are great thanks

  • @testingtechnicians6751
    @testingtechnicians6751 Před rokem +1

    I was waiting your video this morning, thinking what is it going to be 🤔

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +1

      Hope you enjoyed it, after making you wait. Thanks for watching. Dave.

  • @northeastcorals
    @northeastcorals Před rokem

    Ive watched videos on this subject in the past but none were as clearly explained as this one, top notch 👍

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      Glad it was helpful and thanks for watching. Lots more to come. Dave.

  • @user-qi8tv2sj4m
    @user-qi8tv2sj4m Před 5 měsíci

    Brilliant, just brilliant.

  • @tonybaker7453
    @tonybaker7453 Před 10 měsíci

    Very good. Nice and simple. The hard bit is often the mystery of the socket runs and sequence along with spurs

    • @learnelectrics4402
      @learnelectrics4402  Před 10 měsíci

      Always draw what you see Tony, take loads of notes and save them in case you go back. Sometimes the only way is to disconnect at the board and resistance test on the most sensitive scale that your multimeter will go to and look for the ohms to increase as you move along the wires. Thanks for the input. Dave.

  • @ghulamsarwar8325
    @ghulamsarwar8325 Před rokem

    Very helpful video. Thanks

  • @johngray8798
    @johngray8798 Před rokem

    Brilliant, thank you.

  • @lucapuzzoli8363
    @lucapuzzoli8363 Před rokem

    Excellent. Thanks 👍

  • @shiamjad
    @shiamjad Před rokem

    Top Content every time

  • @hussmortada
    @hussmortada Před rokem

    Simply the best! I love your methods and I never fail to understand everything clearly. Thank you once again

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +1

      Happy to hear that and thanks for supporting the channel.

    • @hussmortada
      @hussmortada Před rokem

      @@learnelectrics4402 I wonder if you could do a video on under voltage faults, possible reasons and solutions. Regards

  • @robertwainwright5441
    @robertwainwright5441 Před 9 měsíci

    Brilliant videos 👍

  • @craigg7418
    @craigg7418 Před rokem

    Brilliant, this is the easiest way 😊

  • @DanTheElectricalApprentice

    Hi want to say thanks for the videos, recently started studying again at the age of 27, starting my NVQ level 3 next week and I've been watching your videos a lot to get my head round it all. cheers dave

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +1

      Best of luck Dan, you can do it. I know lots of folk who started in their late 20s through to 40s and they now have crackin little businesses. Stick with it, learn a little every day. It takes time, but time is what makes you good. Dave.

  • @robertwainwright5441
    @robertwainwright5441 Před 10 měsíci

    Another great video 👍

    • @learnelectrics4402
      @learnelectrics4402  Před 10 měsíci

      Thanks for watching, very much appreciated.

    • @robertwainwright5441
      @robertwainwright5441 Před 9 měsíci

      @@learnelectrics4402 your videos have helped an old man getting into being an electrician 👍 keep up the great work..

  • @hibernatus40
    @hibernatus40 Před 4 měsíci

    Top Quality as usual🍺🍺🍺

  • @ibrahimabdullah4430
    @ibrahimabdullah4430 Před 5 měsíci

    Thank you 🙏🙏

  • @jamalel-sahati8632
    @jamalel-sahati8632 Před 7 měsíci

    thank you

  • @jamiemarks1944
    @jamiemarks1944 Před 13 dny

    Can u please do a fault finding on lighting circuit please

  • @generosity3545
    @generosity3545 Před 8 měsíci

    Really usefull

  • @greatrixbrad
    @greatrixbrad Před rokem

    Excellent video, as always. As a suggestion, it might be worthwhile to link in description to your video that shows how to map out the path of a ring circuit, in case it’s not as logical a path as shown here. My own house has a strange ring, with two adjacent sockets in the lounge having a path upstairs (serving all sockets) then back down, rather than just being joined to one another…. Linking up that other video with this one makes a useful complement.

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      That's a great idea, also suggested by another viewer. I will get this done and thanks for the prompt. Dave.

  • @train4905
    @train4905 Před dnem

    Awsome😊😊

  • @ja_adam_
    @ja_adam_ Před rokem +1

    Hi Dave, issue at home please could you help, I was washing car with jet wash, when I went to unplug I got a very noticeable shock , a good tingle in my fingers that made me pull away quick… the plug was wet as I’d mistakenly left the socket lid up and it had got pretty wet as were my hands. I’m guessing some electricity was leaking up through the moisture. The sockets are on an RCD but it never tripped? I tested the RCD and it trips in time and tripped at 25ma on a ramp test. Any idea why it wouldn’t have tripped? I’m guessing there was at least 25mA of current leaking as I got a good tingle so should have tripped ?

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +1

      If you've tested it and it trips ok, then I would say that the shock current you felt was a lot less than 30mA.
      they do say that a current as low as 10mA will make you sit up and take notice. Also, if you were wearing rubber soled shoes that would reduce the shock current too. Lesson learnt I guess. Hope you're OK. Dave.

  • @brianhewitt8618
    @brianhewitt8618 Před rokem +1

    👌

  • @henrystevens2258
    @henrystevens2258 Před rokem

    In theory this is a good way but the problem with doing it this way is as the resistance rises you think this the wiring route that as been installed but the sockets can and in most cases in my experience can give false results because of there age are how they been used over the year ,so after many times of fixing breaks in rings it really is better to remove the sockets of the wall.

  • @pcg1276
    @pcg1276 Před rokem

    How do you identify incoming and outgoing pvc singles at the board?

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      Have a look at the video on the link below. When you do the crossover, a correct crossover will be R1+R2/4 at each socket. If you have incoming and outgoing mixed up, you will get very different values at each socket.
      czcams.com/video/iVAEDEvNObE/video.html

    • @pcg1276
      @pcg1276 Před rokem

      @@learnelectrics4402 Thanks I'll do that test first in future.

  • @persocommeysolarpowersys-zk9pu

    Is it possible to use a ring circuit for lighting purposes?

    • @learnelectrics4402
      @learnelectrics4402  Před rokem +1

      Nothing wrong with that, except that for most lighting at 6A or 10A breakers, the T/E cable easily copes with the demand current as a radial.

    • @tonybaker7453
      @tonybaker7453 Před 10 měsíci

      Yes but use a 3A, 5A fused spur to protect the additional lighting circuit cable.

  • @mikegmarshall
    @mikegmarshall Před rokem +1

    Great video thanks - I use the same method. I use the continuity buzzer on my MFT but same result - been a spark since 1980 but I could listen to you all day cheers Dave keep em coming 👍

    • @learnelectrics4402
      @learnelectrics4402  Před rokem

      Great tip Mike. Thanks for your support, really appreciated. Dave.