FIXING 24 VOLTS LOW INSULATION | Marine Electrician

Sdílet
Vložit
  • čas přidán 15. 08. 2024
  • 24 VOLTS LOW INSULATION, I consider this as part of the critical system onboard. You cannot just simply drop off any breakers as it may affect the operations of the Main Engine and Auxiliary Engines.
    It may cause blackout or slow down once essential breakers have been off.

Komentáře • 61

  • @Dilidjent
    @Dilidjent Před rokem

    Wow, the things you are doing for future generations are pure gold my friend. God bless you!

  • @eboytheeminent831
    @eboytheeminent831 Před 3 lety +3

    I like your touch, this is amazing. It's such a great pleasure to be in a position to explore your career. Keep it up. Congratulations.

  • @adrianaberion8140
    @adrianaberion8140 Před 4 lety +1

    Thanks, very informative, lalo na sa mga 3 A/E na walang kasamang electrician sa barko

  • @bertapartv
    @bertapartv Před rokem +1

    Very nice master

  • @johncantrell614
    @johncantrell614 Před 2 lety

    Good work. I have to admit, that one probably might have stumped me.

  • @jeromewelch7409
    @jeromewelch7409 Před 3 lety

    your an awesome diagnostician very methodical in your approach thanks for lesson.

  • @reyvincentgumapac210
    @reyvincentgumapac210 Před 3 lety

    Laking tulong to sir thank you po ngyon po ganito problema namin

  • @viraltandel7769
    @viraltandel7769 Před 2 lety

    please make video on DG sensors.. how to check & maintain well

  • @picachou8561
    @picachou8561 Před 4 lety +1

    Galing talaga leck. Keep up the good work leck

  • @senthilanbalagan8532
    @senthilanbalagan8532 Před 4 lety +1

    Nicely explained great job

  • @kknk5072
    @kknk5072 Před 6 měsíci

    Thank you Sir.

  • @PeaceMah
    @PeaceMah Před 2 lety

    You da man Jake. Bravo.

  • @gavinofuedan2664
    @gavinofuedan2664 Před 3 lety

    Superb Isolation sir

  • @denis_artemov
    @denis_artemov Před 3 lety +1

    Thanks for your great videos!

  • @mohdkhaja2713
    @mohdkhaja2713 Před rokem

    Lot of thanks sir.
    I take knowledge from u

  • @shyster717
    @shyster717 Před 2 lety

    Good material, I am also with Maersk. On Santa class unfortunatelly, when you have a 24VDC earth fault, there is an engine stop...but this fault must be only in engine control modules to let it happen.

    • @leckyjake
      @leckyjake  Před 2 lety

      Just had on the ECU B 2 days back and good thing it was fixed immediately. I am doing this fault finding specifically for the MAN B&W engine.

  • @scorpiomarine-electrocutio7460

    Goodpm sir leckyjake.. Mayroon ako case dito nah lowinsulation sa 24 V, nka zero ang insulation meter, P at N nag ilaw .pag ene earth test ko sya nag nonormal at infinity reading at ang namamatay na lamp indicatior ay ang N. Pag balik ko naman sa earth test switch sa normal position, mag zero at P N ang iilaw olit. Ang ginawa ko sa dc switchbaord namin, dhil may 2 breakers, (DC-A for navagitional equipments, fire alarms etc. at DC-B para sa Engine control console at main switchboard ) sa DC-A na inoff ko hindi sya nag normal, pero sa DC-B nung inoff ko nawala ang low insulation nag normal na.so doon ako SA panel board sa engine control room(DC-B)nka fuse na lng sila, 4 na fuse, ang 2 fuse ay para sa main switchboard positive at negative, at ang dalawa pang iba ay sa engine control console.. Tinanggal ko isa-isa ang positive fuse ng main switchboard, at engine control console. Wla parin,So tinanggal ko ang mga negative fuses. Sa engine control console wala parin nangyayari, pero nung ang negative fuse na tinggal ko sa main switchboard. Nwala na ang low insulation at nag infinity.
    1.)Engine control console(alarms indicators and anunciators)
    2.)DC Main Switchboard alarm (alarm circuit na may tatlong cards. Alarma Para sa low insulation 440,low insulation 100,preferencial trip at Emer. GEN. Eng. Abnormal at power ng lamp indicators sa emergency gen., (Emergency Gen. run, eng Abnormal at stanby ,
    nung tinggalan ko ito ng negative fuse saka pa nawala ang low insulation.Ngayun palang tu nagka low insulation 24v,kadalasan nmn dito ay 440v,100v.

  • @aveshgupta4252
    @aveshgupta4252 Před 6 měsíci

    Thank you 🙏

  • @abdalrahembarham4343
    @abdalrahembarham4343 Před 3 lety +1

    Thanks for your info Mr.lecky
    How did you test the sensor in DG control panel ?
    and can we start the generator if there was an earth fault in it ??
    Hoping you can answer my multi answer!!!

  • @MsPinks007
    @MsPinks007 Před 3 lety

    Superb lecky sir.. waiting for your new trouble shooting videos...👍

  • @subhammondal6294
    @subhammondal6294 Před 4 lety +1

    Nice video sir.
    Thank you very much sir.

  • @adityaputra6747
    @adityaputra6747 Před 9 měsíci

    Hi Jake, this is pretty much helpful. i have question. but what if the alarm comes and goes, it just triggered for few second. and back to normal. how to find the source in this situation.

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp Před 2 lety +1

    Thanks 👍

  • @BroskiTheGreat
    @BroskiTheGreat Před rokem

    Outstanding 👏

  • @ademothmen450
    @ademothmen450 Před rokem

    Some ship there is not existing 24 vdc inducator of fault insulation,how to know that? Is it from 220v inducator ?!

  • @bt9604
    @bt9604 Před rokem

    When u connect the wire to gnd both the lights should dim, how only one did, since they are in series

  • @fcgaylan
    @fcgaylan Před 3 lety

    You're the BEST !!!

  • @arvinagullana6679
    @arvinagullana6679 Před 4 lety +1

    Sir.. good day.. thank you for sharing your knowledge to us especially to those who are new to the work..
    Sir, kung okay lang.. pwd ba makahingi ng tips/ guidelines on how to recover during blackout. Bago lang po ako sir. Thank you sir and God bless

    • @leckyjake
      @leckyjake  Před 4 lety +1

      Will keep that in mind. Magandang topic yan

    • @arvinagullana6679
      @arvinagullana6679 Před 4 lety

      @@leckyjake thank you sir jake... God bless po

  • @kahar2011
    @kahar2011 Před 4 lety +1

    Nice explain sir, thanks for your share..

    • @leckyjake
      @leckyjake  Před 4 lety

      Thank you. Please like and share 😉

    • @kahar2011
      @kahar2011 Před 4 lety

      I am electrician to, please follow my channel.. thanks

  • @dilipsangada6691
    @dilipsangada6691 Před 4 lety +1

    Good morning sir from india

  • @ionaandshienahendwonderlan1904

    Idol lecky tnx for sharing

  • @monzurhasan3583
    @monzurhasan3583 Před 4 lety

    Thank you so much

  • @dreamoto7251
    @dreamoto7251 Před 2 lety

    Sir Im a newbie in ship electrician , nag trouble po yung auxillary namin hindi na po ma auto yung gobernor nya,, pwede po ba pa advice kung ano ang dahilan nito at bakit ?
    Top fan nyo po ako sir

  • @jackpot7029
    @jackpot7029 Před 3 lety

    Sir any idea about ang generator engine alternator, alarm low insulation 440v triggered when generator has a load, pag naka idle po wla naman alarm,...anu kaya possible problem and troubleshooting ?tanx

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp Před 3 lety

    Thanks dear

  • @dshinkori
    @dshinkori Před 2 lety

    Good keep it up

  • @DANI-ru3vt
    @DANI-ru3vt Před 4 lety

    Sir, I would like to ask one question. If you don't mind, please tell what are things are needed before joining the ship.

  • @ShubhamSingh-bn3vx
    @ShubhamSingh-bn3vx Před 3 lety

    What u were checking in those sensor? IR value???

  • @radhakrishna1008
    @radhakrishna1008 Před 4 lety

    Plz make a video on power system on how 440V is converted and fed to 24V loads.. I mean from generation of 440V to different types (I.e. volts) of loads...

  • @noblehormeku7326
    @noblehormeku7326 Před 2 lety

    i will like to work with you one day on a ship one fine day kudos to you

  • @joelsemblante3486
    @joelsemblante3486 Před 4 lety

    Same sa kabayo ko dto sir 24v low insulation ang hirap hanapin kac intermittent yong alarm seconds lang mawala na both navigation at sa port susulpot...

  • @johnandes8861
    @johnandes8861 Před 4 lety

    Sir Jake san po kaya maganda magtraining about sa marine electrical. kakatapos ko lang isang contrata ko as wiper. gusto ko rin sana maginf eto gaya nyo REE at RME din po ako.

    • @FloroJrGaray
      @FloroJrGaray Před 3 lety

      Try mo UMTC,NTC,GIGAMARE...May trainee cadetship sila dun sir.

  • @manoranjan4598
    @manoranjan4598 Před 3 lety

    Nice medam aur banaiye video realy ke baare me

  • @ManojYadav-or6tj
    @ManojYadav-or6tj Před 2 lety

    Hii sr

  • @alfrazernudalo1060
    @alfrazernudalo1060 Před 2 lety

    😉

  • @hafizanismujahid5375
    @hafizanismujahid5375 Před rokem

    I cant understand..