SPRINKLER SYSTEM INSTALLATION | Bakit Kailangan ng Sprinkler System sa Building?

Sdílet
Vložit
  • čas přidán 20. 07. 2020
  • Ang Sprinkler System Installation ay alinsunod sa NFPA 13 or Standards of Sprinkler System. Alamin kung paano ginawa ang Sprinkler System sa Loob ng building. 👷‍♂
    #sprinkler #sprinklersystem #fireprotection
    www.nfpa.org,
    www.sciencedirect.com,
    sprinkler system,
    sprinkler sound effect,
    sprinkler diy,
    sprinkler system design,
    sprinkler dance,
    sprinkler system philippines,
    sprinkler irrigation,
    sprinkler gun,
    sprinkler agriculture,
    sprinkler animation,
    sprinkler aerator,
    sprinkler arduino,
    sprinkler accident,
    sprinkler activation,
    sprinkler alarm system,
    sprinkler assembly,
    a sprinkler zone is not working,
    a sprinkler system,
    sprinkler bloxburg,
    sprinkler bottle,
    sprinkler booster pump,
    sprinkler ball,
    sprinkler ball toy,
    sprinkler buddy,
    sprinkler bl3,
    sprinkler beat,
    b hyve wifi sprinkler timer,
    b hyve indoor sprinkler timer,
    bhyve sprinkler,
    b whirly whale sprinkler,
    rainbow arch sprinkler b&m,
    b hyve smart sprinkler timer,
    b&q sprinkler,
    b hyve wifi sprinkler,
    sprinkler can,
    sprinkler calculation,
    sprinkler cooling system,
    sprinkler control valve,
    sprinkler control panel,
    sprinkler ceiling,
    sprinkler controller,
    sprinkler cooler,
    hunter pro-c sprinkler controller,
    c clamp sprinkler pipe,
    sprinkler design,
    sprinkler donation,
    sprinkler diagram,
    sprinkler dn50,
    sprinkler durian,
    sprinkler distance from each other,
    sprinkler emote,
    sprinkler escutcheon removal,
    sprinkler experiment,
    sprinkler extension,
    sprinkler ep jayarajan,
    sprinkler easy,
    sprinkler emitters,
    sprinkler enthanu,
    e p jayarajan sprinkler,
    sprinkler for garden,
    sprinkler fitter,
    sprinkler for small garden,
    sprinkler fire,
    sprinkler for plants,
    sprinkler fountain,
    sprinkler for banana,
    sprinkler for agriculture,
    sprinkler garden,
    sprinkler green screen,
    sprinkler glitch bee swarm simulator,
    sprinkler garden hose,
    sprinkler grass,
    sprinkler glitch,
    sprinkler gardena,
    sprinkler head,
    sprinkler hose,
    sprinkler hacks,
    sprinkler head slow motion,
    sprinkler how it works,
    sprinkler head types,
    sprinkler head installation,
    sprinkler how to make,
    sprinkler in minecraft,
    sprinkler installation,
    sprinkler in stardew valley,
    sprinkler in skyblock,
    sprinkler ideas,
    sprinkler in farm,
    sprinkler irrigation for vegetables,
    i'm sammy sprinkler,
    sprinkler jump,
    sprinkler jet,
    sprinkler jugad,
    sprinkler jayarajan,
    sprinkler jet gun,
    sprinkler jugaad,
    sprinkler jayashankar,
    sprinkler joint repair,
    j house vlogs sprinkler,
    sprinkler kebun durian,
    sprinkler kerala,
    sprinkler karar,
    sprinkler kaise banaye,
    sprinkler kupu kupu,
    sprinkler kitne prakar ke hote hain,
    sprinkler kabut,
    sprinkler kerala news,
    k sprinkler heads,
    k sprinkler head adjustment,
    k rain sprinkler head adjustment,
    k rain sprinkler,
    k rain sprinkler head not rotating,
    sprinkler k factor,
    k rain sprinkler valve,
    k rain sprinkler timer,
    sprinkler layout,
    sprinkler line,
    sprinkler laugh,
    sprinkler long range,
    sprinkler lawn system,
    sprinkler line leak,
    sprinkler layout stardew valley,
    sprinkler layout design,
    gardena aquazoom l sprinkler,
    fiskars sprinkler l,
    fiskars oszillierender sprinkler l,
    sprinkler minecraft,
    sprinkler mist,
    sprinkler mini,
    sprinkler move,
    sprinkler meaning,
    sprinkler machine,
    sprinkler meme,
    sprinkler mist system,
    m swaraj sprinkler,
    m plus sprinkler,
    sprinkler nozzle,
    sprinkler not rotating,
    sprinkler news,
    sprinkler noise,
    sprinkler not working,
    sprinkler nozzle replacement,
    sprinkler nozzle types,
    sprinkler nozzle size chart,
    sprinkler outlast,
    sprinkler operation,
    sprinkler out of pvc,
    sprinkler on,
    sprinkler openblocks,
    sprinkler onion farm,
    sprinkler on roof to cool house,
    sprinkler obstruction rules explained,
    como funciona o sprinkler,
    sprinkler pump,
    sprinkler pipe,
    sprinkler pipe fitter,
    sprinkler plastic,
    sprinkler price,
    sprinkler pool,
    sprinkler pump repair,
    sprinkler pvc,
    sprinkler e p jayarajan,
    sprinkler quick connect,
    sprinkler quick response,
    sprinkler quick fix coupling,
    sprinkler quick coupling valve,
    sprinkler questions,
    sprinkler quick coupler,
    quick snap sprinkler,
    quality sprinkler stardew valley,
    for_q sprinkler,
    for_q sprinkler system,
    for_q sprinkler einstellen,
    for_q sprinkler turbinesproeier,
    for_q sprinkler impulssproeier,
    sprinkler turbinen versenkregner for_q,
    sprinkler rain,
    sprinkler roblox,
    sprinkler raft,
    sprinkler rust,
    sprinkler rotating,
    sprinkler repair,
    sprinkler rain gun,
    sprinkler rotary,
    r van sprinkler heads,
    sprinkler shower,
    sprinkler sound,
    sprinkler skyblock,
    sprinkler stardew valley,
    sprinklers,
    pop-up sprinkler s 80,
    sprinkler tape,
    sprinkler time,
    sprinkler toy,
    sprinkler test,
    sprinkler tube,
    sprinkler trap,
    sprinkler type,
    sprinkler trap base rust,
    t post sprinkler,
    replace sprinkler t joint,
    t rex sprinkler,
    t rex mondo sprinkler,
    t bird sprinkler adjustment,
    fix sprinkler t junction,
    sprinkler t connector,
    t post sprinkler head,
    sprinkler using bottle,
    sprinkler upright type,
    sprinkler uk,
    sprinkler under sidewalk,
    sprinkler usa,
    sprinkler underground,
    sprinkler under driveway,
    sprinkler use,
    sprinkler valve,
  • Zábava

Komentáře • 86

  • @JUANCIVILIAN
    @JUANCIVILIAN  Před 3 lety

    INSTALLATION OF SPRINKLER HEAD 👇
    czcams.com/video/9BuuCj73xmA/video.html

  • @Leli8390
    @Leli8390 Před 4 lety +1

    Great construction materials marangal na trabho i salute sa inyo proud for this kind of Job God bless

  • @hmlardizabal4374
    @hmlardizabal4374 Před 4 lety +1

    Kelangan talaga yan kapatid salamat kapatid sa hindi pag limot hehe big like po

  • @xiaomix2983
    @xiaomix2983 Před 3 lety +2

    Mechanical engineer here. Thanks sa upload. Suggest ko gawa ka ng video about sa stand pipes and Accessories.

    • @mr.unknown6088
      @mr.unknown6088 Před 3 lety

      Brad anong tamang pagkakasunod niyan structural,architectural.....ano na next niyan gineer?

    • @xiaomix2983
      @xiaomix2983 Před 3 lety

      Interms of designing: architectural (base plan), structural, mechanical, electrical and sanitary.
      Implementation: civil, sanitary, electrical or mechanical and ofcourse guided by architectural depende po sa gagawing proyekto. Yun kasi sir ang observations ko sa mga previous projects ko, residential, commercial and mixed use building.

  • @inhinyerongsibil6383
    @inhinyerongsibil6383 Před 4 lety +1

    ayus para sa sunog ito ahh... basta pagkatapos ng installation wag kalimutan i testing para iwas tulo

  • @tamemevlog5755
    @tamemevlog5755 Před 2 lety

    Nkakamiss gnyan trabaho ko dati sa loxon Phil. Ako nagkakabit ng brancline sa bawat unit sa condo. Ako din nglalagay ng droppings.

  • @DSDEsigNPhilippines
    @DSDEsigNPhilippines Před 2 lety

    New subscriber here 🥰

  • @boyskilledtv9469
    @boyskilledtv9469 Před 2 lety

    Good day boss new supporter @ friend to your channel.... Shout out to D'SKILLEDMIX DIY TV godbless

  • @jorengalanida3208
    @jorengalanida3208 Před 4 lety +1

    Salamat Idol 😍

  • @regiegayacan4165
    @regiegayacan4165 Před 3 lety

    Sir Pwede Po mg pagawa ng disign NG planu fire protection apat n palapag Po mini condo po

  • @romyjaydemecillo2055
    @romyjaydemecillo2055 Před 3 lety +1

    Hi sir. Beginner po ako. Ano po requirements ng sway bracing. Need po ba talaga yan?

  • @superjaysiblero6144
    @superjaysiblero6144 Před rokem

    di po ba kayo nahirapan mag install ng crossmain at branchline pipes ksi nauna na yung framing, ano po diskarte nyo jn?

  • @cookingwithKumare
    @cookingwithKumare Před 3 lety +1

    nasa magkano po ba need na budget pag magpapa install ng water sprinkler.

  • @kuyamojeck7880
    @kuyamojeck7880 Před 2 lety

    Riser yong nakatura sa arrow papuntang pump room

  • @johncarlruiz8952
    @johncarlruiz8952 Před 3 lety

    Nice Video po sir. Informative po. :) Nag iwan na po ako ng marka . Btw po, Saang company po kayo nagwowork sir. ?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      Hello po, salamat. Bakit po sir? 3rd party po yung sprinkler namin.

    • @johncarlruiz8952
      @johncarlruiz8952 Před 3 lety

      @@JUANCIVILIANWelcome po. ahh kayo po ba yung contractor ng fire pro sir ? Baka po kasi may hiring po dyan sa company niyo po sir.

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      @@johncarlruiz8952 hello po, ibang contractor po sila, sort of subcon.

    • @johncarlruiz8952
      @johncarlruiz8952 Před 3 lety

      @@JUANCIVILIAN Ahh ok po sir. San po pala location nila. Anu po name ng company?

  • @jofranluna6021
    @jofranluna6021 Před 3 lety +1

    Sir magkano po mag pa install ng watersprinkler?

  • @yeraxisa178
    @yeraxisa178 Před rokem

    Ano pong pipe ginamit dyan?

  • @obaydul6654
    @obaydul6654 Před 2 lety

    How much will I actually pay for this work and how much time will I have to work?

  • @kuyamojeck7880
    @kuyamojeck7880 Před 2 lety

    Yong katabi nya drain 2.5" yata or 2"

  • @jamesbascon423
    @jamesbascon423 Před 2 lety

    Sir pwede po magtanong , nagbabago po b ang pressure sa riser time to time, nataas o nababa sa pressure gauge, kasi may nagsabi po na gawa raw po ng temp? Meron nmn ngsabi na wlang koneksyon ang temp, salamat po sir at more power sa channel nio.

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 2 lety

      Hello po, hnd po kasi ako expert regarding sa mechanical works sir..pero sa tingin ko po may mga factors din sguro na mabago ang pressure, lalo na pag kalaonan may sumingaw or leak pipes (branches).

  • @jakemobius8976
    @jakemobius8976 Před 3 lety

    Sir is that a GI or BI pipes? Anong schedule?

  • @ernestogabo7586
    @ernestogabo7586 Před 3 lety

    Bkit nauna pang i installed ang kisame,gayong wla pang linya ng firepro,hayan hirap tuloy gumalaw ang mga pipe fitter?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello po, yan po ang challenge sir pag iba iba ang contractor at matagal mag start c fire pro.

    • @johnyblaze6347
      @johnyblaze6347 Před 3 lety

      Minsan talaga nirrequest ng ibang fire pro contractor na mauna ang ceiling frame kasi yan ginagamit nila reference para sa drop ng sprinkler. Hassle nga lang s kanila yan pag mag kabit na.

  • @junbrillo4607
    @junbrillo4607 Před 3 lety +1

    ask ko lang po sir kung pwede ba gumamit ng pipe size 1/2? or anu po ba ang minimum standard size ng pipe na gagamitin?

    • @GRM0420
      @GRM0420 Před 3 lety

      Depende po sa application yan sir. May computation or estimation po ang pipe sizing.

    • @zaccblack103
      @zaccblack103 Před rokem +1

      Usually 1" ang pinakamaliit na ginagamit. Ang sprinkler heads ay 1/2" yan kaya ginagamitan ng coupling reducer na 1" x 1/2" to connect the sprinkler heads and the pipe droppings. So pwede naman cguro gamitin, iniiwasan lang sa practice kasi tataas ang pressure drop as the pipe size decreases. Pero, di po talaga ginagamit sa practice yan sir. I have yet to discover na ginamit ang 1/2" sa installation.

  • @angelosalinas4057
    @angelosalinas4057 Před 2 lety

    Boss 4 sorey 97sq/m2 po nakalagay dun sprinkler mahal po kc pd poba ung pamatay sunog nakadirect lng sa water tank na may fire stinguisher sana masagot u po salamat

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 2 lety

      Hello po, mas mabuting makipag ugnayan po kayo sa BFP sir kasi nasa kanila po ang approval at inspections, may mga guidelines din po sila regarding sa sprinkler system. Salamat po

    • @angelosalinas4057
      @angelosalinas4057 Před 2 lety

      @@JUANCIVILIAN pero boss pag 4 storey hlos required sprinkler po b?

    • @christiandolatre1560
      @christiandolatre1560 Před 2 lety

      Anyari. Bat nauna p Yung acoustic ..Hirap toluy magsmapa ng crossmain

  • @jandericklubuguin377
    @jandericklubuguin377 Před 3 lety +1

    Hello Sir. May tanong po ako. Entry level po ako ngayon sa work ko at napasok ako sa fire protection works. Ano pong dapat kong unahin na aralin? Salamat po. God bless!

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      Hello po, observe ka lang sa mga plans tapos verify mo yung mga symbols and etc na hnd mo alam, the first step of learning is to admit that you don't know, tapos wag ka din mahiyang magtanong2 sa mga workers. Godbless you 👷‍♂

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      Installation of Pendent Sprinkler Head 👇
      czcams.com/video/9BuuCj73xmA/video.html

  • @engineeringphilippineschan9638

    SINO PO BA ANG AUTHORIZED PIPIRMA NG SPRNKLER SYSTEM PLAN? CIVIL HO BA OR MASTER PLUMBER O ARCHT. OR MECHANICAL ENGR.?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello po, base sa experience ko. PME (Professional Mechanical Engineer) po ang pipirma at nagdedesign ng sprinkler system.

    • @mr.unknown6088
      @mr.unknown6088 Před 3 lety

      @@JUANCIVILIAN actually pwede naman mag design ang electrical sa firepro ee at me lng ang pwedeng mag mepfs...

  • @frankienovela5155
    @frankienovela5155 Před 3 lety +1

    Hello sir. Ano po bang pwedeng maging rason para ireduce masyado yung size ng tubo sa isang building? Kase yung may kontrata kami ng erpat ko sabi nya di na daw pasok sa scheduling yung sizes ng pipe. Yung teacher ko noong college ang gumuhit neto. Yung mainline nya de uno lang. 5 storey hotel building. Thank youuu!

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello po, sa pagkakaalam ko sir mas maliit na tubo mas malakas ang pressure..kaya sguro pinareduce para kahit hanggang 5th floor ay kaya parin.

    • @frankienovela5155
      @frankienovela5155 Před 3 lety

      Disregard nalang siguro yung pressure, kase malakas talaga yung pump ng fire pro system. Talagang di ko lang mapagtanto kung bakit sobrang reduced na yung sizes ng pipes ng siamese, riser, mainline at branchline. Kung susuriin talaga basi sa NFPA 13, di nakasunod yung sizes.. Hmmm. By the way, thank you sa sagot nyo. Lage ko rin pinapanood mga videos nyo.

    • @glennganio4851
      @glennganio4851 Před 2 lety

      Kasi pag nagbago ka o reduce may flow o pressure kang ilalagay sa luob ng tubo at kailangan din yun para malaman mo ang sizee ng fire pump mo.

    • @zaccblack103
      @zaccblack103 Před rokem

      May 2 methods ng pag design: and paggamit ng Pipe Schedule Method at paggamit ng Hydraulic Analysis to select the proper pipe sizes. Yung pipe schedule method, luma na yan at it is only allowed under certain conditions as per NFPA13. However, pwede mo sya gawing guide, then perform hydraulic analysis to analyze and verify if sakto lang ang pipe sizing mo. Kaya nga these days, hinahanapan ng BFP at OBO ng hydraulic analysis ang mga fire sprinkler systems. Also, agree ako sa erpat mo - masyadong maliit ang 1" for cross main, pang branches lang yan. Unless cguro kung nakaloop ang cross main mo and it was verified by hydraulic analysis na sakto lang sya and as long di lalagpas sa 175 psi ang pressure ng system mo. It is important to consider din kasi when designing yung economy side. Pwede mo naman paliitan ang pipe sizes para cheaper pero you increase the pressure of the system, lalaki ang horsepower ng fire pump and jockey mo. So, mas maganda to perform hydraulic analysis of the system to find the right balance.

    • @ericdc7009
      @ericdc7009 Před rokem

      Kung 5 storey hotel building kumporme Kung gaano karami yun Room main puede n 6" raisers , manifold 2 1/2 . branch line ,1 1/2 to 1" komporme ulit Kung ilang yun room n lagyan ,, Ilan sprinkler head Ang ilalagay nasa design yan kasi Yun 1" pipe design 2 head sprinkler head Kung gusto no look mo sa NFPA 13 Doon marami code

  • @cegrowber
    @cegrowber Před 3 lety +1

    Pwede po ba magtanong kung paano katagal mag install ng Fire Protection System sa isang building base sa laki ng building?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      Hello po, depende din po sa manpower sir at sa situation, medyo matagal kung installed na ang ceiling, yang project na yan umabot ng apprx. 4 months.

    • @cegrowber
      @cegrowber Před 3 lety

      Thank you Sir! Malaking tulong po ang info na ito

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety +1

      Welcome po sir, Godbless you. 👷‍♂

  • @justinmyname7734
    @justinmyname7734 Před rokem

    buti di kyo nahirapan nauna pa sa inyo un ceiling

  • @LynnMinmae
    @LynnMinmae Před 2 lety

    may question po. required p ba mga 4 storey building na naka fire sprinkler system?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 2 lety +1

      Hello po, sa tingin ko po sir yes. I think at least 2,000 sq na floor area. Verify nyo nalang po sa BFP sir. Salamat po

    • @LynnMinmae
      @LynnMinmae Před 2 lety +1

      @@JUANCIVILIAN thank you sir

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 2 lety +1

      Welcome sir. Godbless po

  • @fidescuello461
    @fidescuello461 Před 2 lety

    Bossing ask ko lang kase nasa requirement ng fire safety yan mahal yata yan, meron bang substitute jan na pwedeng gamitin, slamat

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 2 lety +1

      Hello po, pagmalaki na po yung area sir fire sprinkler system na po ang kailangan, pero pag maliit lang pwd na ang fire distinguisher

    • @fidescuello461
      @fidescuello461 Před 2 lety

      @@JUANCIVILIAN bossinga need namen ng installer ng sprinkler yun masyadong mahal at maaprubahan ng Fire Dept me pwede ka bang irecommend

    • @liliacampanano6182
      @liliacampanano6182 Před 2 lety

      New subscribersir, ask lng po 4rthfloor with roofdeck bahaynmin
      80 square meter required b n maglagay fire sprinkler?

  • @butikegtv3590
    @butikegtv3590 Před 2 lety

    MAGKANO PAINSTALL BOSS

  • @jaimepagtalunan3335
    @jaimepagtalunan3335 Před 3 lety

    pano ka namin ma contak kailangan namin ng installer sir

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello po, ibigay nyo po ang email address nyo sir para ma e refer ko po kayo.

    • @chaomarco46
      @chaomarco46 Před 3 lety

      ako boss

  • @glennganio4851
    @glennganio4851 Před 2 lety

    Mali yung gumamit ng plastic straw...dapat tefplone tape ang gamit..

  • @GRM0420
    @GRM0420 Před 3 lety

    Bakit po may Nitrogen/gas sa system?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello, saang part po ng video sir ?

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Oxygen/acetylene gas tank po ata ang nkita nyo sir, pang putol ng bakal.

  • @josuearienza2748
    @josuearienza2748 Před 3 lety

    Ka bisaya nmo mag pronounce oi

  • @saimoncalix8628
    @saimoncalix8628 Před 2 lety

    Paano po hydrotest niyan sir?

  • @robertoliwao5210
    @robertoliwao5210 Před 3 lety

    Kawawa namn mga fitter jan sir nahuli kau sa install...

    • @JUANCIVILIAN
      @JUANCIVILIAN  Před 3 lety

      Hello, huli po kasi yung design dyan, kaya ganyan po.

  • @jhunverfillarca7863
    @jhunverfillarca7863 Před 3 lety

    Kawawa po installer 😅, bat nahuli po ang firepro. dapat nauna sila .

    • @mr.unknown6088
      @mr.unknown6088 Před 3 lety

      Oo nga eh haha...dapat after plumbing nakalagay na yan..

  • @kumanderkapitan
    @kumanderkapitan Před 3 lety

    Sir Ilan po b standards distance between two sprinkler heads

    • @Sirbeastmoto
      @Sirbeastmoto Před 3 lety

      As per nfpa 13
      1.8 minimum and a Max. Ranging 3.6 to 4.8 meters Heads to Heads sprinkler