zamil package unit trip reason asolutions

Sdílet
Vložit
  • čas přidán 26. 08. 2024
  • welcome to my CZcams channel mk technical solutions this channel making for technology education learn HVAC rooftop package ac satend ac tower ac split ac air cooled chiller and water cooled chiller and cold storage and freezer all tipe freeze and ice candy palant and centrifugal chiller gas charging and oil charging
    m.k technical solutions me aap shahi ka Seagate karta hu ye channel par aap ac freeze ice palant nand cooled storage ke bare jane wale hai okay bhai
    #l keywords
    #how to check compressor Ground with megger meter
    how to check compressor coman run start #digital compressor ka ground kaise check kare
    #electric compressor ko kaise direct kaise start kare
    #inverter compressor ka ground kaise check kare
    #moter ka ground kaise check kare
    #cable ka ground kaise check kare
    #digital package ac compressor tripping problem
    #package ac compressor lockout
    #zamil package ac compressor tripping problem

Komentáře • 32

  • @AmitAmit-yy5md
    @AmitAmit-yy5md Před 6 měsíci +1

    Good video sir

  • @Atishkumar8852
    @Atishkumar8852 Před 5 měsíci +1

    Very good video 👌👌👌👌👌👌👍👍👍👍👍👍👍👍🙏🙏🙏🙏

  • @KashifKhan-jg6gs
    @KashifKhan-jg6gs Před 6 měsíci +1

    Very good video

  • @PremSingvlog
    @PremSingvlog Před měsícem

    Nice video

  • @muheelhvac1954
    @muheelhvac1954 Před 6 měsíci +1

    Nice brother

  • @mahamdulhasan6892
    @mahamdulhasan6892 Před 6 měsíci +1

    ❤ Always helpful brother everyday esa practical video upload kare brother ❤😮

  • @user-jg7ow3cu6d
    @user-jg7ow3cu6d Před 6 měsíci +1

    Nice

  • @amzadcooltech8528
    @amzadcooltech8528 Před 5 měsíci

    Very good bro

  • @user-nb9ez5fk5s
    @user-nb9ez5fk5s Před 5 měsíci

    Excellent

  • @mktechnicalsolutions
    @mktechnicalsolutions  Před 6 měsíci

    This video for new technician

  • @hamidjalal4687
    @hamidjalal4687 Před 6 měsíci +1

    Bhai kis point per check karteh hai ki compressor ke contacts per 24volt hai ki nai. Check KAHA karteh hai

    • @mktechnicalsolutions
      @mktechnicalsolutions  Před 6 měsíci

      Bhai jo contector का A1aur A2 hota waha pe likha hota nahi to jo contector ka ditels diya hota hai waha pe likha hota hai okay bhai contector coil 24 volt ka hai या 230 volt ka hai

  • @shaikhsabir3828
    @shaikhsabir3828 Před 2 měsíci

    155 LRA compresure single phase compresue start hota h high amp leke trip ho jata h.compresure heat v hota h.compresure ko cold karne k baad on nhi hota compresue new compresue h gas sb thik h.new capacitor dala h 55 mfd ka.

  • @AmitAmit-yy5md
    @AmitAmit-yy5md Před 6 měsíci +1

    Sir aapki company mein job milega ac technician ki full nolej hai🙏🙏🙏🙏🙏❤️

  • @user-te1rt7jt2t
    @user-te1rt7jt2t Před měsícem

    Bhai Jo contactor ke niche me LGA hai wo kya hai Usme kaise setting Hoti hai please reply bhai

  • @javedanjum4770
    @javedanjum4770 Před 4 měsíci

    Zamil pacu k both compressoe ddc ma trip ho jaty hyn compressor run ni hyn.but pcb ma koi alarm ni ha. Kia waja ho sakti ha

    • @mktechnicalsolutions
      @mktechnicalsolutions  Před 3 měsíci +1

      Aapka Matlab hai aapke BMS ddc me trip hota hai bataye pahle ok bhai

    • @javedanjum4770
      @javedanjum4770 Před 3 měsíci

      @@mktechnicalsolutions ddc ma alaram hota ha but pcb ma koi indication ni hoti

  • @lostandfound78
    @lostandfound78 Před 5 měsíci

    Bhai saab blower run ho rahaa hai lekin compressor temprature me cut off nahi ho rahata hai...

    • @mktechnicalsolutions
      @mktechnicalsolutions  Před 5 měsíci

      OK bhai aapka package ac room temperature mention kar rha hai ki nahi

    • @mktechnicalsolutions
      @mktechnicalsolutions  Před 5 měsíci

      Aapka ac ka probalm hai compressor cut off nahi ho rha hai ok bhai aapka package unit BMS se canection hai to aap returns air sensor ko check kare augr tharmostat se hai to tharmostat me temperature ko badha ke check kare phir bhi nahi thik hota hai to tharmostat ko chenge kare okay bhai

    • @mktechnicalsolutions
      @mktechnicalsolutions  Před 5 měsíci

      Aur aapka ac room temperature mention nahi kar payega to bhi cut off nahi milega okay bhai