Why Solar Energy Consume First ? // How Import and Export Works in Solar system ?
Vložit
- čas přidán 26. 11. 2021
- Why Solar Energy Consume First ? // How Import and Export Works in Solar system ?
#export #import #solar #solarsystem #solarinverter
Solar
Safest
Smarter
Saur urja
Biljli Kaise bachaye
Solar se Bijli Kaise Bachaye
Benefits of Installing solar
Profitable solar
Solar k Fayede
Solar Lagane k Fayade
MCB
MCCB
ACB
AJB
ACDB
DCDB
Lighting Arrester
walkway
cable Tray
Solar Panel
Solar Inverter
Solar Cable
AC Cable
Follow me on -
Telegram- t.me/+uVOzUWjDk0tiNTBl
LinkedIn- / raman-kumar-666436141
Facebook - / solarfacts-37057195372...
solar structures
Solar panel mounting structure
Solar mounting structure
acdb and dcdb for solar system
acdb box price
dcdb box for solar system
dcdb box price
long rail solar structure
mini rail for solar panels
mini rail solar structure
solar mounting structures
solar panel structure
solar structure
solar structure types
types of mounting structures for solar panels
types of solar mounting structure
types of solar structure
mounting structure for solar panels
mono rail solar structure
solar acdb box
solar acdb dcdb box
solar dcdb box
solar mini rail
standing seam solar structure
tilted solar structure
acdb box for solar
dcdb box for solar
Video link -
1. How solar zero export works.- lnkd.in/evPgfuj2
2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
6. How to check Current Transformers? - lnkd.in/eT5gc99e
7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
• Solar Power Plant Shad...
18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
30.What is Skin Effect ? // Why Skin effect happens in AC not in DC ? // Why current flow through surface of conductor ? -- lnkd.in/eHTtuFtK
For more information contact us 😊.
Name - Raman Kumar
Contact No- 9871073342
Very Nice,
Excellent and detailed explanation. Really appreciate it.
Nice information.
एकदम सही गुरु...
good work bro...........
Loveable explanation ❤
Great information , well done 👍
Thanks 👍
Very well prepared
Thank you
Thanks 🙏
बहुत बेहतरीन समझाया है आपने
❤❤
Best information friend,Thanks
Excellent explanation
Excellent and detailed explanation
Well explained
Thanks 🙏
Fantastic. Great description of how the system works. So easy to comprehend even for a layperson.
thank you sir
V informativ
Informative video , thank you Raman ji
Thanks 🙏
बहुत बहुत आभार।
Thanks you
Hi ...Thanks For Sharing Your Valuable knowledge.. Excepting English Subtitles ...it will be helpful more.
Sure 👍
Very informative video 👍👍
Thanks 🙏
Highly informative for those who are in solar sector ,keep it up sir. Please make a presentation on sizing of Solar power plant and DG set.
Ok sure I will make one video
Good.!! Well explained. Keep it up.
Thank you, I will
thanks so much, sir very useful knowledge thanks again 😎
Thanks you 🙏
According to power transmission theorem, the power always tries to flow towards Lower impedance path. Compare to grid, the local load impedance will be less so power flows towards to local load. That's the actual principle.
0.1 is very negligible, inverter need to increase atleast 1% of gird voltage. 2 -2.3 volts. the solar inverter need to stay in higher potential than the grid.
In order to push power to grid.
Need to fine tune information. All the best
thank you so much for your input sir.
It's true
The difference in Voltage after sync only transfers reactive power.
Best explanation 👍
Thank you 🙂
Good information. One question how does this work in case there 2 on grid inverters connected and feeding to same phase. How these 2 inverters manage rise in voltage since both inverters will try to sync to grid and raise the voltage. Will they keep on fighting with each other in this case? Kindly elaborate. Thanks
But in Load panel, both sources are coming on common bus bar. So on single conductor ( bus bar ) how two different voltages shall be available ?
You are great sir
Thank you
How does export-import meter work? How it is connected in the circuit?
👍👍👍👍
Thanks you brother....
.I got my answer
thanks
Kya koi aisa sysytem bn skta h Agr ongrid solar m grid se light nhi aarhi h to kya fir bhi m solar ki ligh se apne appliances chla ske
Thankuu sir
Thanks
Hi, thanks for sharing now how does the load export into the grid? Means how it's transferred into the grid?
Through the same line
Is spd or fuse used first in dcdb?
Can you make a seperate video on off grid inverter with charge controller and old home inverter. How the solar system will work in above combination?
Sure will
Make
Thank you sir but on grid system me grid jane par aam tor par jo pahle se hamare gharo jo invertor laga hai kam karega ?
Home ups kaam
Karega but aap solar Panel ka ise nahi kar sakte
My house import is 3 phase
But soLar inverter single phase.
Then day time consumption from 3 phase what import export effect us.
In AC power, increase in frequency caused the transfer of Watt.
Ok
Thanks
Sir delhi me discom ka ek formality hai ki ELCB bhi use karna h to usko kaha pe installed karenge
grid wire per
I was going through trina module data sheet the current is very high more than 17 amps , is there any on grid inverter in 3ktl or 5ktl capacity which is compatible with this module?
Yes havells
See my video where I have explained how to connect higher wattage high current module with smaller inverter
Hello sir,mene 4kw ka on grid system lagvayahe or mera 1ph meter he to esme aeksath 3 A.C chalastehe???
On grid me inverter capacity se koi problem nahi hai
Sir, PLEASE kindly look into my matter,
I have installed 3kw ON GRID residential Solar system with zero export device, i have single phase meter connection in my home,
But i am facing a problem, the problem is that despite having zero export device my solar system is producing more than my home running load and the extra power solar is producing, it is taking from the METER( that is from the grid),
But when i increase the load according to the solar power production then it doesn't not take from METER and when i further increase the load more than the solar power production then only it takes EXTRA load from the METER,
SO Please tell me sir why it is taking power from METER when it is producing more than the RUNNING LOAD? and
why it is producing more than the RUNNING LOAD?
And
the extra power more than the load produced by the Solar system is showing in NEGATIVE (ex- Minus 600 watt, minus 1000 watt like this) in the ZERO EXPORT DEVICE and the same it is taking from the GRID METER.
Kindly resolve my issue sir....i will be very thankful to you 🙏
Please share me videos and photos so that I can understand better
Hi Raman
Sorry But For active power flow voltage difference is never the criteria.
Did you ever confirmed this reason with any solar inverter manufacturer ?
Yes confirmed with inverter manufacturer
Right 👍 not voltage but frequency is the reason.
What is the output of ongrid solar inverter ?
Is it pure sine wave like AC or square wave ?
Shine wave
When there is no netmeter and zero export is to be done, in that case MFM has to be installed on the grid panel, now my question is if MFM is installed on the grid panel, how to know the load at that time.
At you LT panel your entire load is connected and by taking the values from the panel we can control the system
Thanks a lot Raman ji,
My question is that some people says, both Discom & Solar Current comes together but inverter increase the potential of current so we get Solar Current first.
Is it ?
Sir inverter increase the amplitude of voltage that’s why energy generated from solar Inveter consume first
@@solarfacts4242I think voltage is not the reason, slightly increasing the frequency active power transfers after sync. Increase in Voltage is causing reactive power transfer.
Solar system structure design karna sikhao....
Ok sure
for me the gap between generated and exported unit is increasing drastically...today is fifth day and the difference is 15 units (55 - 40 = 15) 55 generated, 40 exported...and the gap between imported and exported is just 2-3 units...is it how it normally works or is it only me? please reply
Sir please check the Channel I have one video on this topic also
When there is Transformer bet. load and grid then in case step down transformer how export works. Kindly make a video on this topic.
ok sure
@@solarfacts4242 is there any video relating to the topic.
If my solar has 2kw output and I am consuming 1kw load, then from where is the load consuming energy? From solar or from grid?
Means
Agar mera solar 2kw output de raha hain aur main 1kw istemal kar raha hu toh woh 1kw grid se aa raha hain yaa solar se?
From Solar
Sir how export works ?
My solar will produce current as per load requirement ?
Also since both the source are at same potential difference how current will flow from ongrid inverter to grid ?
Solar inverter Voltage amplitude is higher than grid that’s why
@@solarfacts4242 thank you. Is there any other way other than zero export if I don't want to give back energy to the grid.
@@pankajmazumder2860 if you have no export excess power in to the grid and netmeter is not available then install zero export controller
I have difficult question, no one in Pakistan can ans me. Can u help ?
Inverter details pe presentation
Ok Sure 🙏
why solar generation unit is not similar to export units on main metre
Because we consume
Will my solar excess will expire by govt. on March 31 ?
Yes give us year set off
how solar increase voltage,why?
Inverter increase it’s voltage with respect to grid from where it takes reference.
And inverter increase voltage because load consume higher amplitude source first
10 kilohertz PV panel 10 kilowatt PV current aaega
I have one video how to calculate please go through that video you can check
Samjhane ka Tarika Shai nhi hai
Thanks for input will improve
What language is he speaking?
Hindi
एक्सीलेंट आपका डिस्क्रिप्शन। एकदम क्लियर बता दिया आपने । सर एक कन्फ्यूजन काम कर रहा है। प्लीज क्लियर कीजिए। जैसे ऑफ ग्रिड में लौड के ऊपर इनवर्टर चूसिंग होता है क्या ऑनग्रिड में वह डिफरेंट होता है? मतलब लोड जितना भी हो हम सिर्फ पैनल के कैपेसिटी के ऊपर इनवर्टर चूस करें? प्लीज रिप्लाई सर
Reply kijiye plz
Reply kijiye plz
Hii sir apka number mil sakhta he kya