  • Called out for no cooling, found the defrost board not passing voltage on to contactor. I bypassed board, and charged system. Also I show a terribly designed air handler. #hvac #hvaclife #fieldpiece #makita #aspen

Komentáře • 37

  • @coltes007
    @coltes007 Před 29 dny

    Thank you so much your video saved me a service call and God knows how much they wouldve tried to charge me

  • @luckybeltz3892
    @luckybeltz3892 Před 2 lety +1

    Once again complete troubleshooting no wasted steps !!!

  • @W4AX
    @W4AX Před 2 lety

    Great detective work!

  • @carlossaenz4075
    @carlossaenz4075 Před 2 lety

    Great video

  • @lancelawrence3259
    @lancelawrence3259 Před 2 lety

    Nice work

  • @acrservicesmathewr7565

    Only thing better then a goodman is a greatman. Great video.

  • @bryansimon4072
    @bryansimon4072 Před 2 lety

    Good fix

  • @Bryan-Hensley
    @Bryan-Hensley Před 2 lety

    I didn't watch all of this yet but I wanted to add my experience before I forget. I've changed a couple or 3 of these boards only to find out the low pressure switch wires have worn through somewhere. (Which can knock the board out) I've had one pressure switch to open permanently. If that wire is open or grounded it will not turn on the contactor. You might have already figured it out since I didn't have time to watch the whole video

  • @Eddy63
    @Eddy63 Před 2 lety

    Good vid ... Thx ...

  • @caru3257
    @caru3257 Před 2 lety +1

    I really liked my Mantooth probes because I could add refrigerant if needed unfortunately the charging port broke. Fieldpiece and Testo if you are listening... I carry this board as a replacement 47D01U-843 Universal Heat Pump

    • @HVACGUY
      @HVACGUY  Před 2 lety

      I used to use a swivel T with my suction probe, but for some reason it charged extremely slow.

  • @cutum
    @cutum Před 2 lety

    Rock on!

  • @nikkid4798
    @nikkid4798 Před 5 měsíci

    So the defrost board has a high and low pressure cut-off switch. Will the board stop the voltage for any other reason if it is working properly, or are those the only two things that will stop the voltage?

  • @picklerix6162
    @picklerix6162 Před 2 lety

    Those defrost boards seem to have a high failure rate. I believe Aspen Mfg is based in Humble, TX and has been making HVAC coils for a long time. Those Aspen coils were quite popular in Houston for replacement jobs when I was in the HVAC business back in the 80’s. Those coils were dirt cheap back in those days.

  • @justinbelleville1392
    @justinbelleville1392 Před 2 lety

    How come the 2nd pressure switch was getting 0 volts as closed? Wouldn’t it be 24 volts? I assumed that if it was zero there would be no power running to it. Can you please explain. Thanks!

  • @coltes007
    @coltes007 Před 29 dny

    Mine says 30, 60, 90 then the 2 pin test. I moved the cover up one and the red light on board turned off. I plugged fuse back in an it kicked right on

  • @seangriffon6502
    @seangriffon6502 Před 2 lety

    Those Goodman defrost boards fail alot. Also this unit is got a bunch of garbage around it. Since it's a heat pump it needs to be sitting on risers so it can drain properly when it defrosts.

  • @stephwaylonwells3218
    @stephwaylonwells3218 Před 2 lety

    👍

  • @realestateservicessaleshea99

    That looks like another unstoppable Goodman. 😆
    I saw the first utuber with an OXBOX by the trane people . 😃
    Thanks for the video!
    🍺🍺🍺🥃🥃🍿🎯
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

    • @HVACGUY
      @HVACGUY  Před 2 lety +1

      I had to google oxbox, I don’t think I’ve heard of them before

    • @picklerix6162
      @picklerix6162 Před 2 lety

      I believe that you can buy Oxbox equipment online. I hear that Oxbox is made in China.

  • @GonzDez-sh7vx
    @GonzDez-sh7vx Před rokem

    I hate how close the housing is to the liquid port on goodmans

  • @melissachartres3219
    @melissachartres3219 Před 2 lety

    Okay... I'm confused. 09:28 I thought that the suction line WAS the liquid line and that the discharge line was the gas line. What am i missing?

    • @HVACGUY
      @HVACGUY  Před 2 lety +1

      On a heat pump the small line is always the liquid line, hot gas comes from the compressor, so in cooling it goes to condenser to become liquid m and in heating it goes out the big line to evaporator to become liquid. So big line can be suction or hot gas depending on the season.

    • @melissachartres3219
      @melissachartres3219 Před 2 lety

      @@HVACGUY ah. right. thanks kindly for that.

    • @edwardgarza5104
      @edwardgarza5104 Před 2 lety

      @@HVACGUY so the big line is always a high pressure vapor or low pressure vapor on heat pump. Small line will always be a high pressure liquid?

  • @seadeas
    @seadeas Před 2 lety

    Because you’ve worked very hard, and I think very smart, just to be an hourly worker…

  • @DRAggIN123
    @DRAggIN123 Před 2 lety +1

    I would braze in some flair nuts that's a really bad design

    • @HVACGUY
      @HVACGUY  Před 2 lety +2

      That’s a good idea. Measurements would have to be perfect though.

    • @DRAggIN123
      @DRAggIN123 Před 2 lety

      Yes for sure they would have to be

  • @seadeas
    @seadeas Před 2 lety

    I’ve watched several of your videos, and I’m thinking this is your own company!?!?

  • @chrismyvision7494
    @chrismyvision7494 Před rokem

    Ban aspen for that design 😂

  • @YukonHawk1
    @YukonHawk1 Před 2 lety

    Poor design having that line set where it is 🤬