Why does grid voltage goes up or down suddenly due to which our inverter trips again and again ?
Vložit
- čas přidán 5. 09. 2024
- Why does grid voltage goes up or down suddenly due to which our solar inverter trips again and again ?
ग्रिड वोल्टेज अचानक क्यों घटता या बढ़ता है ?
जिससे हमारा सोलर इन्वर्टर बार-बार ट्रिप करता है ?
#neutralproblem #neutralfloating #solarinvertertriping #solarinverterunstability
#neutralbreak
Solar
Safest
Smarter
Saur urja
Biljli Kaise bachaye
Solar se Bijli Kaise Bachaye
Benefits of Installing solar
Profitable solar
Solar k Fayede
Solar Lagane k Fayade
MCB
MCCB
ACB
AJB
ACDB
DCDB
Lighting Arrester
walkway
cable Tray
Solar Panel
Solar Inverter
Solar Cable
AC Cable
Follow me on -
Telegram- t.me/+uVOzUWjD...
LinkedIn- / raman-kumar-666436141
Facebook - / solarfacts-37057195372...
solar structures
Solar panel mounting structure
Solar mounting structure
acdb and dcdb for solar system
acdb box price
dcdb box for solar system
dcdb box price
long rail solar structure
mini rail for solar panels
mini rail solar structure
solar mounting structures
solar panel structure
solar structure
solar structure types
types of mounting structures for solar panels
types of solar mounting structure
types of solar structure
mounting structure for solar panels
mono rail solar structure
solar acdb box
solar acdb dcdb box
solar dcdb box
solar mini rail
standing seam solar structure
tilted solar structure
acdb box for solar
dcdb box for solar
Video link -
1. How solar zero export works.- lnkd.in/evPgfuj2
2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
6. How to check Current Transformers? - lnkd.in/eT5gc99e
7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
• Solar Power Plant Shad...
18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
For more information contact us 😊.
Name - Raman Kumar
Contact No- 9871073342
You are sweating but still your energy levels don't goes down it means you are very passionate on your work.keep it up
Thank you 😊
Yes I have passion 🙂
Excellent 👌
Informative video! thanks for the effort
It is very well explanation to give information to client...👍
Glad to hear that
Very informative video Sir 👍
So nice of you
Very Very very informative 👍👌
thanks
Informative
Thanks
Very nice
Thank you
Great information
Glad you think so!
Excellent !!!
Thank you! Cheers!
Osm knowledge
Thank you so much 😀
Raman ji why we use floating neutral in IDT for solar plant.please make video on this topic thanks.
i did not get, What is IDT ?
@@solarfacts4242 Inverter Duty Transformer
Very much helpful
Thanks
Very informative....
thank you
Very nice video
Thanks
Great Job!!
Wow
thanks
Very informative video....
Thanks a lot
Good knowledge boss
thank you
Thanks sir
thanks
Last year we faced this problems in Gujarat and we damaged equipment in our resident then we found fault was neutral Brocken
yes this is the beigest problem of industry
What is the cause of low voltage in summers and high voltage in winter? I do not have net metering connection yet
Well explained
thanks
nice video sir. kindly make a video on the working principle of reverse peotection relay and it's inner components working too and its circuit diagram sir. it will very on while syn too power sources sir
Sure will make a separate video
Sir
1. what is the difference between power transformer and inverter duty transformer (IDT)?
2. What is use of GHI. Because calculated the PR to GTI, why use of GHI.
Sir please explain....
will make video on it
Nice
thanks
Please make video on solar plant leakage current failure
ok will make
Thank you sir...
thank you
We got this corrected by the discom
Thank you 😊
Why no English subtitles??? Why no Hindi translation to English?!?
Sir
Mere 3KV system me ye pro ho raha hai, Inverter trip ho jata jai phir 172 second ke baad sharu hota hai
Muje stabilizer lgane ke liye bola gaya hai
Kya ye sahi hai ?
sir kindly explain about reverse protection relay
Ok
सर मैने अपने घर में 5 kw का सोलर सिस्टम लगा रखा है cellcronic का इन्वर्टर है अभी ग्रिड से कनेक्ट नहीं हो पाया है CT sensor पर सिस्टम चल रहा है, अक्सर मेरा inverter trip हो जाता है PV 1 और PV 2 में वोल्टेज शो करता है पर पावर नहीं बनती है क्या करना होगा ।
Load kya chalate hai aap
Is there battery in your system
@@solarfacts4242 battery नहीं है on grid कराना है पर अभी हो नहीं पाया है CT sensor लगा कर दिन में लोड चलाता हूं
Sir explain the HVRT, LVRT in solar inverter.
will make video on it
Hi Raman
I have one query -- In 3 phase diagram , you shown broken neutral on the neutral line but in calculation part neutral is shown broken on phase part . So I feel that there is some calculation mistake. Can you please re-check the same. ?
i request to see the video again, there is no calculation error
@@solarfacts4242 YOU ARE WRONG, GRID VOLTAGE WILL INCREASE EVEN IF NETURAL IS PROPER. IT WILL HAPPEN IF TOO MUCH SOLAR PANEL UNDER SAME TRANSFORMER
Sir Mene 3 inverter 1 grid me lagaya hay 1 inverter me koi problem Nahi hai par dusra 2 inverter me over outage voltage problem dikha Raha hai to kya possiblity ho Shakti hai
SIR, maine apne ghar me 3KW ka On-grid solar system lagwaya hai....par abhi iska net metering nahi hua to humne system ka supply ghar me liya hai ZERO EXPORT DEVICE ko connect kar ke.....
Lekin sir jab main ghar ka load increase karta hu to Solar inverter ka VOLTAGE drop hone lagta hai...( ex:- 218-220 Volt hai to wo dheere dheere 170-180 volt pe aa jata hai fir wo thoda increase ho kar 180-190 ke aas paas rehta hai)
Aur power(watt) to solar supply kar rha hota hai but sirf kuch Ampere(ex:- 1-2-3 ampere) meter se lene lag jata hai....jab ki Watt 0-10-15W ke aas paas hi rehta hai)
Fir jab load kam karta huu to voltage badh jata hai aisa ku ho rha hai SIR...?
Main grid se aane wala ghar ka voltage normal rehta hai
..wo 1-2 volt drop karta hai....
PLEAE HELP 🙏
What load you are using
@@solarfacts4242 2-3 fans, 3-4 Led bulbs, fridge, 1 ho water motor and kavi kavi ek 1.5 ton Ac.....
@@solarfacts4242 AC voltage drop check karne ke liye hi on Kiya tha 1 din....uske baad se nahi chalaya hu sir...
Aur jab motor on karta hu to METER(GRID) se AMPERE lene lagta hai....jab ki WATT 0 ke aas paas hi rehta hai.......Matlab Power(watt solar panel se leta hai aur Ampere METER-Grid se lene lagta hai...
Aur power(Watt) badhta hai solar ka to VOLTAGE DROP hone lagta hai...218-220 se 180-190 pe aa jata hai.........
aisa ku ho rha hai....?
I work for DNO, when spring comes lost of pv inverters start tripping at midday sun, all voltage good on supply side with good Eli, how does a customer get this corrected?
Kindly share me your case we will took after
sir, can we add a voltage stabilizer between a solar inverter and grid for stable voltage output?
There will be problem in case of export
Sir mere ghar mein lo voltage aane ke Karan
Solar on grid inverter bar bar trip kar jata hai kya karna hoga
Kya stabilizer se connection de sakte hai
Inverter Havells 3300 hai
same problem here over voltage ki wajah se trip ho rha
My topic is D.G frequency high problem. how to resolve it. Inverter high frequency fault show on screen when D.G on & not working Inverter sync system.
thanks will make one video on it
what are the options for this below mentioned Issue .
I need your advise , if in an industry due to huge welding machines (inductive load) there is voltage fluctuation due to which solar inverter has synchronizing issues , please suggest how can we avoid this voltage fluctuation ?
there is neutral break please check and rectify
@@solarfacts4242 what?
Yes this can be one of the reason
@@solarfacts4242 checked , it is due to huge inductive load actually please suggest solution
Can we connect our neutral to local ground in order to protect our circuit load
you can but earth resistance should be less than one
I faced same problem on my site....but inverter company told me that overvoltage is from grid side , complaint to discomp ?? Is it possible that overvoltage is from grid side
yes it is
In inverter’s event log, it is showing that “AC low volt”, what to do?
check the grid voltage and and then adjust from transformer
if still problem check the load pattern
Very limited access because no other language 😢