Introduction to UL 508A Industrial Electrical Control Panels with PLC

Sdílet
Vložit
  • čas přidán 1. 12. 2020
  • In this video we take an exciting look at UL 508A Industrial Control Panels including PLCs and HMIs.
    Get the full details of this lesson at:
    twcontrols.com/ul508a-control...
    Items used in this video:
    UL 508A Industrial Control Panel twcontrols.com/control-panels
    The above links make these videos possible. Please use them!
    Support these videos while you advance your skills courses.twcontrols.com/
  • Věda a technologie

Komentáře • 115

  • @adampitt7052
    @adampitt7052 Před 3 lety +7

    This is what Ive been waiting for. Looking forward to this series.

  • @hjp520
    @hjp520 Před 3 měsíci +1

    Thanks from New Orleans!!

  • @brady0630
    @brady0630 Před rokem +3

    you probably have the best presentation so far. good stuff. will be watching the entire series.

  • @faschwank
    @faschwank Před 6 měsíci +1

    Nice job with the ferrules.

  • @CommercialGasEngineerVideos

    Many thanks from the UK.

  • @jomahank6314
    @jomahank6314 Před 2 lety +1

    great way of teatching
    thank you from Morocco.

  • @NeGRaDiCaLz
    @NeGRaDiCaLz Před rokem +2

    I like that your disconnect handle will literally cover an inch of your HMI when you turn it on with the door closed.

    • @TimWilborne
      @TimWilborne  Před rokem +2

      That's all you got out of the video....😂

  • @JB-hq7vp
    @JB-hq7vp Před 3 lety +1

    I work for Prime Controls in Dallas and really enjoy your videos!

  • @k50159
    @k50159 Před 2 měsíci +1

    Much appreciated Tim

  • @jasonryan2175
    @jasonryan2175 Před 3 lety +5

    love it! do more of these!!

  • @taylor2160
    @taylor2160 Před rokem +2

    I would like to question the spacing requirements for your components. UL got me with that on my first panel that got inspected. Typically a power supply, especially ones that convert 3 phase into 24vdc require at least about 1.5 inches above and below. It does not look like those requirements have been met. Love your videos man. Great content. Would love to ve able to bounce automation ideas back and forth.

  • @italyinmoto8494
    @italyinmoto8494 Před rokem +1

    Thank you so much Tim! I just love watching yours video!

  • @rixpanapasa8977
    @rixpanapasa8977 Před 3 lety +1

    Awesome vid Tim....Thanks

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Put in your request for what you want to see in this series.

    • @rixpanapasa8977
      @rixpanapasa8977 Před 3 lety

      @@TimWilborne would really like to see how you size up and set up the electrical panel .

  • @lokeshwar4093
    @lokeshwar4093 Před 3 lety +1

    wonderful, I liked your all playlist and save in library and subscribed before your promotional words :)

  • @ThatNerdyCoolGuy
    @ThatNerdyCoolGuy Před 2 lety +1

    Just wanted to let you know that I found your youtube channel from Linkedin and Jake Hall!

  • @isaacparry8686
    @isaacparry8686 Před 2 lety +1

    I watched the "hater" episode. I like how you were accused of selling yourself for AB when in reality most things you have in your videos is AD stuff. That's a testament to an untrained eye. Minus maybe the PLC! I'm pretty sure I even saw a DL05 in there somewhere. Personally I'd rather use the DoMore! in one of it's various form factors, or I hate to say it, a Micro800 of some sort for simple applications. (although you absolutely should hard code you're variables in those as they have a tendency to go brain dead for no reason!) The Click! isn't much more reliable, but it is cheaper. Both software's are free. (At least the non-developer edition for the AB) Anyway, I like you're series, you are a pioneer in the socialization of the field. WE NEED MORE CONTROLS GUYS, people don't understand how fun this stuff is! I almost want to keep it a secret, or everybody will want to do it!

  • @gurjantsingh6647
    @gurjantsingh6647 Před 3 lety +1

    Good video'
    I want to learn this tips.

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Great, we'll be uploading more videos about this soon so subscribe.

  • @aboshnb97
    @aboshnb97 Před rokem +1

    Hi Tim,
    Thanks a lot for all the tutorial videos. I learned a lot by following your tutorials really appreciate that. Is there any video about calculating the total load of the whole control panel by going to each components? I'm trying to get that for my application in order to size a step down transformer and a safety disconnect switch. Thanks a lot!!!

    • @TimWilborne
      @TimWilborne  Před rokem +1

      This is one I have avoid because it's not as simple as adding up all the loads and multiplying that by safety factor, it depends on the types of loads, size, and locality.

  • @bblee2150
    @bblee2150 Před 2 lety +1

    Nice video Tim! Can you talk about the wire color coding when building a panel? I can't find much information for the color coding for such as AC voltage, DC voltage and etc.
    Thank you!

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      I am going to soon but you won't like it. The only color that is required is green for grounded conductors :)

  • @joshkraai7657
    @joshkraai7657 Před 3 lety +2

    I really enjoy this video break down in easy terms to understand. I would like to see in one of your videos how and why you choose the panel lay out you did. Like which components can be next to one another and how you have to be careful about wiring crossing each other (high voltage/low voltage)

    • @TimWilborne
      @TimWilborne  Před 3 lety +2

      We're working on a panel layout video. It is a little tricky but hopefully we'll get the kinks worked out.

    • @christopherlyons7613
      @christopherlyons7613 Před rokem

      ​@@TimWilborneHI Tim. Have you made any progress on doing the Panel Layout video? That would be great information to show and it could help many of us. Thanks.

  • @trevorthobe8528
    @trevorthobe8528 Před 2 lety +1

    Hey Tim! Have you done any videos yet going over how to calculate SCCR?

    • @TimWilborne
      @TimWilborne  Před 2 lety +3

      It is up for the next group of control panel videos.

  • @coasterbp
    @coasterbp Před 3 lety +1

    Hey Tim, Do you through bolt your components to your back plane or drill and tap?

    • @TimWilborne
      @TimWilborne  Před 3 lety +2

      I'm 99% sure code doesn't allow through bolting components. And if code doesn't prohibit it then it should. I always drill and tap. If the diameter is too large for the thickness of the panel then they make volts that can be riveted into the panel.

  • @dwaynes5983
    @dwaynes5983 Před 2 lety +2

    I always leave the space above disconnect open. Thought it was code back in 90s??

  • @indian.techsupport
    @indian.techsupport Před 27 dny

    Din is an acronym which translates to "german industrial norm" which is basically the german iso. There many more din norms than just those rails.

    • @TimWilborne
      @TimWilborne  Před 25 dny +1

      Yep, here is a video on DIN rail.
      czcams.com/video/7QuITImfDqc/video.html

  • @steveestey
    @steveestey Před 2 lety +1

    Hi Tim, great series! I noticed one thing in particular that surprised me, you don't label your panel components, why is that? Also I live in Canada and this may just be a difference in code requirements but I also noticed no fuse charts on the door, are you guys not required?

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      Our UL standards are the same. As far as labeling, it can be done by the component, on the door in a panel layout such as you mention, or on a drawing. This is one of our training panels so it get reconfigured often, hence not permanent labels.

  • @csdrip
    @csdrip Před 3 lety +1

    Is there a list of labels that are required by UL for ICP's? For instance "to maintain overcurrent protection...."

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Not in a broad sense. There are some labels every panel may require but many are specific for the situation.

  • @sanjaygurung7623
    @sanjaygurung7623 Před rokem +1

    Hello, I don’t find wiring diagram on video description

    • @TimWilborne
      @TimWilborne  Před rokem

      You're right, we're revising our website and that link is missing. See if I can get it put back up.

  • @christopherlyons7613
    @christopherlyons7613 Před rokem +1

    Hi Tim. Thanks for your videos. I have a question about UL508 wire colors. Can you please provide some basic info on recommended AC & DC wire color guidelines.
    Also, what format do you use for your wire numbers? Thanks.

    • @TimWilborne
      @TimWilborne  Před rokem +1

      I have a video on wire colors in my drafts. Many people don't like my answer but according to UL 508A for industrial control panels which is what 99% of labels are, you only need to mark grounds as green. The rest is regional and even varies across the USA. I'll have some examples in it.
      Here are some sample wiring diagrams, the wire numbers are based on the page and line number.
      controls.tw/sample-drawings

    • @christopherlyons7613
      @christopherlyons7613 Před rokem

      @@TimWilborne Thanks. Doesn't UL508A make some statements about wire colors (i.e.66.5 (Power) & 66.9.1 (Control Circuits) (not sure if these are current section #s)? I believe they state that all ungrounded AC power connections should be BLACK (RED if < supply voltage) and all grounded AC connections should be GREY or WHITE. For DC control circuits they say to use BLUE for all ungrounded DC connections and WHITE WITH BLUE STRIPE for grounded DC connections. I realize there is some openness in the spec regarding these colors. But if you were to follow this basic color scheme would that be sufficient? Are there any other basic colors that you tend to use? Regarding your upcoming Wire Color video, any idea when it will be released? Looking for a beta tester? Appreciate any help you can provide. Thanks.

    • @TimWilborne
      @TimWilborne  Před rokem

      @@christopherlyons7613 ​ No, this is the most commonly misused sections. 65, 66, and 67 are for Industrial Machinery, not industrial control panels. Industrial Machinery labels are very rarely used, in fact I've never seen one.

  • @rcandrew8780
    @rcandrew8780 Před rokem +1

    Hi Tim,great videos..i really like that disconnect switch what brand and or PN is it?

  • @leandrodortaduque3392
    @leandrodortaduque3392 Před 3 lety +1

    What kind of license/permit/certification do I need to do this kind of job and being certified by UL?

  • @danielsowa8209
    @danielsowa8209 Před 3 lety +1

    I don't see the wiring diagram, I'm still a nube and I like following those for practice. I love this channel though!

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Hi Daniel, they are at the link below.
      twcontrols.com/lessons/introduction-to-electrical-control-panels-including-plcs-and-hmis

    • @danielsowa8209
      @danielsowa8209 Před 3 lety +1

      @@TimWilborne Hey, you actually answered! Well I enjoy your videos so I signed up for the first tier of Patreon. Keep up the good work! Thanks for the link too.

    • @TimWilborne
      @TimWilborne  Před 3 lety

      @@danielsowa8209 Thank you for your support!

  • @EETechs
    @EETechs Před 2 lety

    Can you use MTW 16 or 18 AWG wire inside control panels for the control wiring to save on money for wire as long as the proper fuse size is chosen? I read somewhere that UL508a says only 20 AWG or smaller wire has special requirements limited to PLC connections only.

    • @TimWilborne
      @TimWilborne  Před 2 lety

      UL says "power wiring" must be 14awg, with a few exceptions, they don't specify control wire size.

  • @uisignorant
    @uisignorant Před dnem +1

    Did you actually run AC and DC in the same duct?

  • @kevinburt3075
    @kevinburt3075 Před 3 lety +1

    How do you make the label for the outside of the panel is this special software ?

    • @TimWilborne
      @TimWilborne  Před 3 lety +2

      Hi Kevin. I use a Brady BMP71 for all my labeling. See links below.
      BMP71 amzn.to/3cqs3FN
      Nameplate labels amzn.to/3oAsDD9

    • @kevinburt3075
      @kevinburt3075 Před 3 lety

      @@TimWilborne thank you

  • @jhoon6227
    @jhoon6227 Před 2 lety +1

    Hi, I dont see schematics in description to download. Is it removed?

    • @TimWilborne
      @TimWilborne  Před 2 lety +2

      No, we're moving some links around right now trying to consolidate items, here you go.
      twcontrols.com/lessons/standard-electrical-control-panel-and-plc-trainer-drawings

  • @jessecastro9717
    @jessecastro9717 Před rokem +1

    Do you still have classes? Where are you located?

    • @TimWilborne
      @TimWilborne  Před rokem +1

      Yes in Roanoke Virginia. You can learn more about our training at:
      twcontrols.com/allen-bradley-plc-training

  • @rameshnatarajan5746
    @rameshnatarajan5746 Před 2 lety +1

    I have main ac panel ,ac distribution junction box.in ac panel we have main mccb(earth protection) for on-off,
    Ac distribution Power cable taken from Ac panel main circuit breaker control.
    Is this needed any separate mccb for ac distributions box .(in ac distribution box we have 30 MCB,30ssr,two controller).

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      Yes there is more needed, you need to dig into the NEC book.

    • @rameshnatarajan5746
      @rameshnatarajan5746 Před 2 lety

      @@TimWilborne Thanks for your response.Could you please share authentic links for NEC ,UL508A.
      Suggest any course are there for ul508a .

  • @pushpakarmishra1441
    @pushpakarmishra1441 Před 3 lety +1

    sir pls make videos over VFDs

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      See link below.
      twcontrols.com/ac-drives-and-3-phase-motors

  • @Bosanac_99
    @Bosanac_99 Před rokem +1

    Would products certified only to the UL508a standard be accepted in Canada?

    • @TimWilborne
      @TimWilborne  Před rokem +1

      There is a Canadian marking for UL 508A. It has a C on the left side of the UL and a US on the right side.

    • @Bosanac_99
      @Bosanac_99 Před rokem

      @@TimWilborne OK, one more question, please. Would cUL508 certified products be accepted by CSA standards in Canada?

  • @MyRefriedBeans18
    @MyRefriedBeans18 Před měsícem +1

    I don't see a grounding lug for the incoming power.

    • @TimWilborne
      @TimWilborne  Před měsícem +1

      It's the green thing 🙄 Did you have a question about it?

  • @_stardust__
    @_stardust__ Před 3 lety +1

    Where can I get that enclosure?

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      www.theautomationstore.com/control-panels/

  • @vidzbelikewoah
    @vidzbelikewoah Před 10 měsíci +1

    Good afternoon, I’m about to start classes to be a ul 508a Mtr. Do have any advice and recommendations of books I should have? Thanknyou

    • @TimWilborne
      @TimWilborne  Před 10 měsíci +1

      Do UL's practice exams. They cover everything you need to pass.

    • @vidzbelikewoah
      @vidzbelikewoah Před 10 měsíci +1

      @@TimWilborne thank you

    • @TimWilborne
      @TimWilborne  Před 10 měsíci +1

      Good luck. Definitely don't go into the test blind. It was difficult

    • @vidzbelikewoah
      @vidzbelikewoah Před 9 měsíci

      Good afternoon, do you know how I can find the practice exam? I’ve looked on ul website and couldn’t find anything on an practice exam for ul508a

  • @fiifinenyi2156
    @fiifinenyi2156 Před 2 lety +1

    please am from Ghana
    how can I buy a micrologic 1100 or 1000. I have been searching since in my area but can't find one

    • @TimWilborne
      @TimWilborne  Před 2 lety +1

      The first question is what PLC is popular in your area.

    • @fiifinenyi2156
      @fiifinenyi2156 Před 2 lety

      @@TimWilborne so far in all the company's I worked as an intern they don't use one brand, I have seen Mitsubishi, Siemens, Omron and in my school they use Allen Bradley

  • @Munira495
    @Munira495 Před rokem +1

    Iwant take online course so how to take?

    • @TimWilborne
      @TimWilborne  Před rokem +1

      Here you go.
      twcontrols.com/plc-lessons

  • @khoanguyen4780
    @khoanguyen4780 Před rokem +1

    what is standard of wire color sir?

    • @TimWilborne
      @TimWilborne  Před rokem +2

      According to UK standards, ground has to be green. The rest is regional. I have a video coming on this.

    • @khoanguyen4780
      @khoanguyen4780 Před rokem

      @@TimWilborne I hope to see it soon

  • @langlymcmanus1194
    @langlymcmanus1194 Před 3 lety +1

    Where's your overcurrent protection (fuses)????

    • @TimWilborne
      @TimWilborne  Před 3 lety +1

      Uh did you watch the video? There in it...

    • @langlymcmanus1194
      @langlymcmanus1194 Před 3 lety

      I'll answer myself = 15A main CB so motors are group protected. The LVPS must be a self protected type?

    • @langlymcmanus1194
      @langlymcmanus1194 Před 3 lety

      @@TimWilborne I don't see any fuses, nothing rated 5kA but I may be blind. Is there a link to the electrical schematic? Might be a good idea?
      UL508A requires that the main switch (CB) be able to be switched with door open, I don’t see a handle that allows that? Anyway I subscribed and will check out some other video's. Great response time ... lol

  • @steadywatching7564
    @steadywatching7564 Před 3 lety +1

    What!? I like the beard.

  • @Fulzomatic
    @Fulzomatic Před rokem +4

    Is grounding important? 🤣😂

    • @TimWilborne
      @TimWilborne  Před rokem +3

      Can you tell I used to work at a place where they didn't think grounding was important 😁

  • @lefi75
    @lefi75 Před 3 lety +1

    "Does it need a label?"
    Can you just say yes next time?

  • @celsiusfahrenheit1176
    @celsiusfahrenheit1176 Před rokem +1

    Hi Tim, I have a computer science degree and a minor in electronics, I became an electrical contractor while studying. I did an online PLC basics certification. I am thinking of doing the PLC II which covers Rockwell 5000 series, SCADA, DCS etc. My question you you is what else do I need to get enough knowledge and experience to start offering my services for the automation industry specifically, PLCs, scada, MES, and ERP integration?

    • @TimWilborne
      @TimWilborne  Před rokem +1

      The biggest thing would be opportunities for troubleshooting experience. That will go further than PLC II.

  • @mrashad219
    @mrashad219 Před 3 hodinami

    UL standard is ass backwards why so much blue where is the -.
    What was wrong with Red + and Black -?