Sizing and Installing Hydronic Expansion Tanks

Sdílet
Vložit
  • čas přidán 8. 09. 2024
  • Hydronic expansion tanks are sized on boiler NET output BTU's and the type of radiation. It is also important to install the expansion tank properly - mounted vertically in downward position only. Ensure the piping can support the entire weight of the tank when full of water.
    Making The Trades Great Again & Giving Back To The Community: / channel
    Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridge...
    I use the HIK Micro B20 thermal camera to verify working equipment
    amzn.to/3BkJC5Q and I wear Brunt pants and boots available here: bruntworkwear....
    Tired of HouseCall Pro? Don't wanna be ripped off with ServiceTitan? Try ServicePal for free for 30 days! app.servicepal...
    (You can thank me later)
    Please take a moment and click that 👍 button! Much appreciate the support from the community.
    Check out my Uncensored channel: / mikeypipesuncensored
    Oval raised silver stickers are from:
    Armored Decal Company Inc.
    35 Victoria St. E, Unit 9
    Alliston, Ontario L9R 1T3
    (p) 705-435-6665
    (e) ken@armoreddecal.com
    (Tell them Mikey Pipes sent you)
    Please support this channel and Mikey Pipes and consider the following…
    UPDATED: March 16, 2023
    PIPE DOCTOR FLEX FIT HATS only $40 each shipped USPS! Or 2 for $70
    Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
    Sticker Requests:
    Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
    Name
    Address
    City, State, Zip
    Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
    Donations Accepted:
    PayPal: office@pipedoc.net
    Venmo: @PipeDoctor
    CashApp: $mikeypipesny
    Zelle: office@pipedoc.net
    Want to send a love letter, note or gift? Our mailing address is:
    Mikey Pipes
    C/O Pipe Doctor Home Services, Inc.
    80 E Hawthorne Ave
    Valley Stream, NY 11580
    Join our team! PIPE DOCTOR HOME SERVICES is expanding to the great State of South Carolina!
    WE ARE ACTIVELY HIRING:
    SERVICE PLUMBERS
    HVAC TECHNICIANS
    DISPATCHERS
    For our location in:
    HILTON HEAD, SC

Komentáře • 62

  • @mikecurtis1281
    @mikecurtis1281 Před rokem +3

    Mikey pipes! Which lazer level was this??

  • @eddiew.6485
    @eddiew.6485 Před rokem +1

    Going the extra mile, Mikey with that laser level and getting the job done! FACTS!,,,,

  • @danobrien3109
    @danobrien3109 Před rokem +1

    Nice work Mike and smart adding the isolation valve. Figure that tank will weigh 75 to 80 lbs while it is operable and about 125 when it fails. Water weigh roughly 10 lbs per gallon.👍👍🇨🇦

  • @johnhegarty3491
    @johnhegarty3491 Před rokem +1

    You could have put a double bend offset on the 3/8” rod. Also, I believe it’s Dewalt that makes what they call the “smart DI (drop in anchor drill bit” for the sds+ that has a stopper at the exact depth of the drop in. And it has an attachment that you put over the drill bit that you use to hammer the anchor in with the hammer drill. It’s really nice.

  • @throttlebottle5906
    @throttlebottle5906 Před rokem

    you could have done two hangers in V shape to avoid the pipe above.
    alt 1: used half of two larger clevises to go around the pipe (bolted together with short bolts)
    alt 2: just hang it from the larger pipe above(clevis to clevis) and that pipe above to the ceiling with a clevis against the one below.
    alt 3: I'm less thrilled with, but gently bend the rod(long radius bends) out around the pipe. if not gentle bends it can be weakened and even then it may flex enough to overload the nipples/coupling and break off suddenly. especially the newer "junk" brass fittings.

  • @franciscoc3369
    @franciscoc3369 Před rokem

    I'm happy

  • @Aepek
    @Aepek Před rokem

    Palm beach, FL…..AHH MAN, that’s 3.5 hrs away from me, BUMMER!
    If we’re closer in service area, w/ way do business, after the initial meet and greet and 1st maintenance call, if better t(an company use now, which wouldn’t be hard to beat, imo, woulda have most likely gotten 45% of entire HOA live in.
    Well, Palm Beach gets you in FL, and that don’t mean can’t open 2nd shop in my area in the future😉
    Anywho, CONGRATS & HAPPY FOR YOU AND Fam, Team, Company for expanding to SC and FL.
    Cheers✌🏻

  • @nightone9720
    @nightone9720 Před rokem

    Mikey Pipes you make my day. I think I love you. Well, at least I love your channel!

  • @Threee_Eyez
    @Threee_Eyez Před rokem

    Woot woot, my evening dose of Mikey pipes, thanks for sharing.

  • @jstoney6471
    @jstoney6471 Před rokem

    Mikey...Small world! Back in the mid 80's I shot Amtrol's National Advertising films for 2 years...Spokesman was Claude Akins.

  • @HERITAGEWV
    @HERITAGEWV Před rokem +1

    The 30 wasn’t cross threaded, if you look closely the nipple that was welded to that 30 tank was slightly angled…. Manufactured defect.

  • @tmactheplumber4966
    @tmactheplumber4966 Před rokem

    I love clevis hangers, nice support !

  • @pskrak1
    @pskrak1 Před rokem

    i noticed the date on the 30 lol, doesn't look like you planned to put in the 90 ha ha , love ya

  • @tinopratt3056
    @tinopratt3056 Před rokem

    Hi pipe doctor like the way you and guys work I'm in the Bahamas also ac technician.

  • @marty0715yt
    @marty0715yt Před rokem

    Franky 2x is presently working AND excelling at Mattress Center!

    • @zwwz4537
      @zwwz4537 Před rokem

      If frankie isn't testing hes guessing

  • @DonaldRicci
    @DonaldRicci Před rokem

    🔧 You did what you had to do Mickey and the hell with the rest🔧

  • @williamdawson6351
    @williamdawson6351 Před rokem

    Temp installs of anything is not perfect but is better than nothing, I have install a temp power outlet just to get power for for a user before while looked down on but is done in when needed or ordered by the upper ups.

  • @richlong4119
    @richlong4119 Před rokem

    I needed one of those tanks couldn’t find one so I installed two 60s together. 😂

  • @ryangreff8340
    @ryangreff8340 Před rokem

    Awesome stuff I learn so much but I’m in Louisiana. Probably will never work on one

  • @kingbulldog107
    @kingbulldog107 Před rokem

    its fun to extend with an ips ball valve instead of a coupling

    • @kingbulldog107
      @kingbulldog107 Před rokem

      those expansion tank isolation valves are sexy AF though

  • @2pugman
    @2pugman Před rokem

    Laser ? COOL !

  • @michaelburgess7703
    @michaelburgess7703 Před rokem +1

    Mr Mackey pikes you going to use that 30 on another job. It should still be good. 👍🤟🌭🍺🍺

  • @throttlebottle5906
    @throttlebottle5906 Před rokem

    1:27 are those party plates on that "range rover" weaving around the lane and hitting the lines or is that just a yellow state plate? (lol)
    Yellow plates with red letters here = party plates, follow them to the party 🤣🤣 "hic hic hic"

  • @lan8262
    @lan8262 Před rokem

    Why wouldn’t you just offset the threaded rod with a bender?

  • @DevinHVACInc
    @DevinHVACInc Před rokem

    Trolls will be trolls. Let it be. At the end u did the right thing

  • @consolidatedplumbingandhea4390

    I have a tank sizing card in my tool bag along with I have no idea why anymore a vent damper recall serial number card. That said, I quickly go from an extroll 30 to a floor mount, just because anything larger is just to heavy to change. Ya, been hit or miss on using the air compressor to get all the water out. In a lot of cases, there is no easy way to support them and the concern of a 60 or worse 90 filling and snapping something, just easier to go to the floor mount.

    • @throttlebottle5906
      @throttlebottle5906 Před rokem

      I agree, #60 max suspended and preferable anything over #30 a floor model, unless the space doesn't permit that. I mean I've had to squeeze in 5 suspended #30's before in a bad location! talk about a cluster-fork-mess. the end result was still better than all the other "proposed" plans.(lol) sometimes I think to "deep space" outside the box levels.

    • @throttlebottle5906
      @throttlebottle5906 Před rokem

      I should add, all five were "horizontal" and in a radial pattern (star shape). it's still that way as far as I know and they just replace tanks when failed. it was oversized by "two" tanks just for added headroom and ease of repair. nothing else would fit, unless someone starts making a pancake style flying saucer tank 🤣🤣
      yeah, I'm rather nuts, but git-r-done-son.

  • @jims9597
    @jims9597 Před rokem

    Great install Mike and forget the haters they are just armchair quarterbacks

  • @jascoplumbingsupply4224

    The 30 would work but fail prematurely correct?

  • @earleclemans4836
    @earleclemans4836 Před rokem

    What is the purpose of the accumulator? Dampening pressure spike?

  • @jasonthejawman5442
    @jasonthejawman5442 Před rokem

    Hello Mikey pipes

  • @peeps9364
    @peeps9364 Před rokem

    Hi Mikey. Hope you are well.

    • @peeps9364
      @peeps9364 Před rokem

      @@PipeDoctor pretty good. Thank you.

  • @eddiehollner8801
    @eddiehollner8801 Před rokem

    Hello Mike

  • @throttlebottle5906
    @throttlebottle5906 Před rokem

    should have went with a floor model tank, once over a "60". much easier to set them down than fiddle around hanging them. if they water log from bad bladder, far less headache to move(dolly) when you don't want to make a huge mess. I don't like anything over a #30 hanging myself, unless the space is very tight.

  • @joed9908
    @joed9908 Před rokem +1

    What's the purpose of that tank?

  • @Aepek
    @Aepek Před rokem

    @Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
    1:41 I guess the ppl who said something about the expansion tank being wrong size didn’t watch the entire video! And listened to what ya said…..or missed what you said 🤷🏼
    B/C I REMEMBER you saying Mikey, you know you had wrong size after looking at the 1 page data sheet fr9m expansion tank AMD YOU SAID needed a 90 and don’t have in truck and would need to c9me back w/ the correct size. Was in the video, unless I’m hearing things, lol.
    So, think most ppl “know” you wouldn’t install a system (or repair a system) w/ improper parts etc……BUT IF YOU DID, it would be for good reason, which would be: unable to get part or didn’t have w/ you; BUT than you’d be back to rectify the situation to MAKE THINGS RIGHT and do the job the way supposed to be done; b/c your Mikey Pipes the pipe doctor and it’s your company’s core value, along w/ TESTING!
    So, don’t listen to those comments (know 1st hand how hard that actually is, it sucks) and keep doing right thing paying attention to details and doing awesome great work👍🏻👍🏻
    Cheers✌🏻

  • @UMAKitsune
    @UMAKitsune Před rokem

    I so want to come work for you

    • @UMAKitsune
      @UMAKitsune Před rokem

      @@PipeDoctor Ok my only thing is is i have to relocate lol from Neberska

  • @scottvolage1752
    @scottvolage1752 Před rokem

    I know supply houses that don't have Extrol 90s in stock. So why would you have one in your van?

    • @richlong4119
      @richlong4119 Před rokem +1

      I installed 2 60s together when I couldn’t find one 😂

    • @scottvolage1752
      @scottvolage1752 Před rokem

      @@richlong4119 And most residential homes do not have 280K BTU systems in them.

  • @leeit2me
    @leeit2me Před rokem

    did you say at the end you swapped out the 30 for a 60??? uhmm. where them trolls at?? lol

  • @jls1259
    @jls1259 Před rokem

    the extrol always brings out the trolls

  • @danielmandel750
    @danielmandel750 Před rokem

    🤙🏻

    • @danielmandel750
      @danielmandel750 Před rokem

      Right on brother love the videos also enjoy listening to you cut the dead weight out of your company. Lazy fucks

  • @lhr1701
    @lhr1701 Před rokem +1

    Ok Mikey now I have to brake your chops. Here we go, the hanger is steel and the pipe is brass. Dissimilar metals are a no no. Lol.

  • @scottmaz4063
    @scottmaz4063 Před rokem

    #1

  • @Nihilumbra
    @Nihilumbra Před rokem

    Trolls mast die😅 good job👍 молодцом)

  • @cindysaunders3330
    @cindysaunders3330 Před 11 měsíci

    Do It Right? Why did you use black pipe ? Mixing metals. Now you need a dialectric union. Don't mix metals.

  • @realestateservicessaleshea99

    😂😅😂🥃🥃🍺🍺

  • @scottmaz4063
    @scottmaz4063 Před rokem

    #1

    • @scottmaz4063
      @scottmaz4063 Před rokem +1

      Chicken dinner, you did the right thing. I've seen installers say they will be back and guess what they never do.

    • @MikeyPipesUncensored
      @MikeyPipesUncensored Před rokem

      @@scottmaz4063 yeah well, if you are a social plumber tradesman I need to show work!