How To Testing Air Conditioner Compressor Pumping | Ac Compressor Testing | Compressor Oil Change
Vložit
- čas přidán 27. 08. 2024
- How To Testing Air Conditioner Compressor Pumping | Ac Compressor Testing | Compressor Oil Change
1 - how to testing air conditioner compressor pumping
2 - compressor pumping test
3 - compressor back pressure
4 - ac discharge pressure
5 - rotary compressor pumping test
6 - rotary compressor oil change
7 - how to change compressor oil
8 - compressor for borewell pumping
9 - compressor pumping effect
10 - ac compressor solenoid valve testing
11 - ac compressor testing
12 - testing car ac compressor
#Amresh11Tech #compressorpumpingtest #howtochangecompressoroil #testingcaraccompressor
काम में इमादार 1 न.आदमी हो,मेहनती इन्सान हो सर आपके बातोसे बहोत सिखने कों मिलता है. Thank u
Welcome Ganesh brother
Aapne clear se explain kiya hai thank you sir
Labbaik ya rosol allah 🇵🇰 bangladesh turkey Pakistan Kashmir falastin zindanad🇵🇰🇧🇩🇹🇷🇵🇸✌️🤺💯👍❤️
Nice video sir ji
Thanks brother
All your vedios super bro. Go ahead, keep upload vedios 👍🙏👌👌👌
Top video
100 💯 ka kam ok mast vidio
Good job
Sir,apka video dekha muje ache laga
Nice information sar thankyou
wellcome
@@AMRESH11TECH sir how to checking and freeze 👍ok 👍
Nice always
मेरे भाई रहम करो और एक ही बात को बार बार मत बोला करो जैसे कि तुमने इस वीडियो में कर की हमारा एक दिन वेस्ट हो गया तुम्हे पता है तुमने कितनी बार बोला इस बात को और जिस टॉपिक पर वीडियो बनाते हो उस टॉपिक को उस कमी को जल्दी बताया करो तुम इतनी बात करने लगते हो वीडियो में की जिस बात को 3 मिनट से 4 मिनट में खत्म किया जा सकता है उसी में बोहत टाइम खपा देते हो
Very very nice sir
Good vedeo sir.
thanks
Service wall single hai to kaise check krege pumping system me
500-700 psi ka pressure fridge ka compressor banata hai ac ka compressor toh or jada banayega pumpping check karne ke liye koi bhi compressor ho uska suction discharge line khole le ir pin valve ya coupler ki madad se pressure gauge laga ke pumping check kare pressure gauge ki sui bina ruke tezi se bhagegi jab gauge ka end hone wala ho turant compressor band kare
exillant
@@AMRESH11TECH Thanks you
Good job sir
Thankes sir welcome
ধন্যবাদ
Har sprit ac ke outdoor mei discharge valve mei chargingline system nahi kuch mei only suchine valve mei he charging line system hota h usme kase check kare
amazing video
thanks
runing time pe 1.5 ton compress ka temperature kit na hota hy..?
tag_faces
Very good
Good information
Bilkul sahi Kiya aapane
BesT video 👌
thanks
@@AMRESH11TECH Everyday esa video upload kare brother ♥
Good
Nice video
Sir मुझे कंप्रेसर रिपेयरिंग का काम खोलना है कंप्रेसर काटना, वेल्डिंग करना, पिस्टन वह स्पेयर पार्ट कहां से खरीदें कृपया इसके बारे में कुछ जानकारी दो
Scroll compressor mai kitna pressure dena hai 5.5.5ton duct ac de compressor pls reply
Outdoor me air stand karne ke bad ye susction se to nikalta hai to ye galat kaise hua sab compressor me nikalta hai
Tnx Sir
welcome md ashraf bhai
Sir.Hamne bohot video me dekha eysa back pressure martaheto oil change karne me tik ho jati he,apne iye try kia?or iye taarika tik he?oil charge karneme tik ho jatihe iye nahi?
nahi hoga bhai, kyonk aisa lhta hai ki compressor ka piston bilkul khatam ho gya hai
Bhai aap bahot kheenchke bast karteho
Pireshat vapas nhi Ana chahiye kya
Tanx bai....
wellcome
@@AMRESH11TECH bhai pls apna no doge yr m ik ac thik kr rha hu but thik nhi ho para pehli bar mere sth esa hua h bhai pls yr apna no dedo m cll ke jriye m puch lunga apse bhai pls ye apna no de rha hu ...6239672085 pls bhi cll me
Bhai sahab compressor se discharge ka pipe nikal Ke 400 ml oil Dal Ke check karo FIR pumping
Bro gas west na ho to kaise karenge pumping check please batao bro
Bhai ye to back mar rha hai na
Back marega to chalu condition me suction pe charging line laga ke bhi pata chalega ya nahi
This is rotary compressor, there is no piston, there is a problem with the Reed valve that's why air is going backwards and also causing the compressor to rotate in reverse due to the air pressure.
Sir , dc inverter compressor main low oil kaise check kare? Aur agar compressor change ho rahahain to new compressor main oil dalna chahiye ?
New compressor me oil dalne ki jaroorat Nahi Hoti Hai , new me already oil hota hai
Hi bro suction valve elenky Se band Karlo bhaiya
Nice ❤️❤️❤️❤️
Bhai Jaan jo gas torch hai uska link send kijiye. Kaha se li wo
bhai offline market se mera boss khrid ke diya hai.
Sir slipt ac system me nahi Laga ho.ac indoor outdoor room me Nikal kar rakha ho bat .ac kharid te samyay kaise pata chalega ki ac sahi hai ya kharab konsi konsi parts check kare please bataye
Aap bahut acche se samjhate ho bro please give me your number 👏👏
Inverter AC ka compressor aise hi check karenge Kaya
runing time pe 1.5 ton compress ka temperature kit na hota hy..?
Sir pumping nehi karta compressor to standing pressure kesa reheta & running pressure kese reheta
Mere ac ka b to outdoor off hony par b kuch dair hilta rehta he yani marta he lekin cooling high-class krta he
Hitachi inverter AC usme foult suction pressure thik lekin cooling nahi ho raha compressor change kiye phir wahi problem phir bhi aa raha hai cooling nahi ho raha
Return bhi nahi aa raha hai
Dishchar pressure chech karne ke leye walve nahi dishcharge only suction valve pe guas lag raha hai
Bhai Apne compressor ka pumping test Kiya tab compressor running tha FIR 300 PSI Ho Gaya tab aapane suction line ellenki se band karna chahie tha
बैक प्रेशर क्या होता है psiप्रेशर क्या होता है
good
thanks
Cold room ma indoor pa 25% ice aa rhi h
Refgrant 404A
Had Prashar 250
Rining prashar 25-30
Falt ksa trash hoga
0 temp ka cold room h
Rining or had or standing prashar kitna ana chiya
6[1/2} Ton ke machin h
Agar compressor me oil kam rahi tu kiya problems karega plz reply
Aap is Samay kaun si company mein hai
Aap comment ka jawab nahi dete hai isliye aapka subscriber nahi badh raha hai
Bhai Ye Discharge Line Nahi Hai. Ye Liquid Line Hai.
Liquid Line Ka Pressure R-22 Refrigerant Par 115 PSI Hi Hota Hai.
Aapke System Me Thoda Refrigerant Gas Aur Oil Top Up Karneki Jarurat Thi.
Rotary Compressor Me Piston Nahi Aata Hai Bhai.
Excellent
@@AMRESH11TECH kya yeh bat sahi h jo bhai ne apko uper btai
Ye Rotary Compressor Hai Isme Piston Nahi Hota Hai, Sir
Hota h
Kon sa pipe jyda cool hota hota h mota ye patla
JyadA tar aisa hitchai me hota hai
Bro Kya aap Bata sakte Hy 1.5,tr,2 tr,,2.5 tr 3 tr in sab ka expect capillary sizes Kya hoga Jo ke sab ac o ke Ander chal sake
ok
Bhai. Compressor . Tonnage k according compressor ka pressure stroke. Hota h islie. 1ton me 0.55 or 2ton me 0.90 ki lagate h
Hi sir kuish amdid
Sir mene bhi ase hi chek ki thi lekin jab me outdor ko band kr raha tha tho sara presar sekshan se nikal gya lekin usme mene ges daal di or wo a.c sahi chal raha h
Rotary compressor ki pumping Achchi ho to Bhi off position me pressure suction Se aa sakta Hai
Jabki Reciprocating Compressor me discharge Reid(Valve) Ke leak hone ki condition me hi pressure wapas Aata hai
Bhai apka no chahiya
Pls kuch discuss karna hai
My no 8267888294
Bhai apka no chahiya
Ek compressor mai mujhe bhi aissa fault mila
Compressor ka prssure -500psi plus hai check karnai par suction say dua nikal raha aur unit kee pipe joint kar gas dali to
Rated current- 6.3amp
Running pressure-55psi
Suction pressure-250 psi
Aur colling nahi ho rahi
Pls arjent reply
Sir Pls Ek Barr Aap Calling Se baat karna hai Aap Se jankari lena Hai
send your number
My ac timer light belling ac tuning half hour ac off automatically
Kese release kia? Hawa par release kia?
Recover nahi kia?
Or kyon yellow pipe lagaya hai. Yellow is for recover, vacuum or recharge not for pressure check.
Package Ac hai Uss mei Suction pressure backum mei ja raha hai Aur discharge 200. R407 hai drier bhi sahi hai aur Expension valve bhi mere khayal se sahi hai amp 11.12. Le raha hai 8.5 tr comp. Hai kya lag raha hai aap ko
Solvnied valve laga ha wo chk kro operate ni ho raha ho ga
@@hvactechnichalservices7513 Nahi Laga hai
@@hvactechnichalservices7513 Wo Uss ka Expansion Vale ke Agey Jo.hai Heder Wo jo Patla patla Pipe Evaporate mei Jata hai Wo Change karna Hoga Wo block hai uss ko cutting kar ke Flash kar ke new laga na Hoga Aur to sab theek hai
Outdoor fan giving cool air indoor not cooling what is the reason
maybe rafrigrant pressure low.. so check rafrigrant
Will I have to fill the gas ?
Thank you very much
Laal colour ka batan dikhai nahi de raha
are bhai kaam rotary ka pressure stand nahi hota.
abhi knowledge lo.
Discharge walve na ho to kaise chek kre
Rotary compressor me piston nehi reheta hai bhai.
Ha bhai
👍
brother oil chek kar lo
Section line se aap bahar ka air dala compressor me bhai
its rotory compressor ther are not any piston there
Bhai aap kaa LPG ka patla achha hai uska photo bhejo na
हेलो सर प्रेशर 300 स्टैंडिंग रुका रहता तो कंप्रेसर ठीक था क्यों सर यही बोलना चाह रहे हैं
Sistem ko pump down kya hua hai to fir pressor kha se ara hai
Rottery compressor presure kbi b stand ni kry ga
Ha
एक बात बताओ जैसा कि तुम बोल रहे हो कि रोटरी कंप्रेशर को सिस्टम में लगे होने पर पम्पिंग अगर चेक करनी हो तो उसमें प्रेशर 150 से ज्यादा ना रोके ऐसे में उकी पम्पिंग का पता कैसे लगेगा कि वो ठीक है या खराब
Sir outdoor unit me direct compressor motor kese on karte hai please help me
Cp ke jaga pe dayrekt power saplay de ke
Amresh bro hmari smssiy ye he hmara ac R22 gesh he istending 150 bta rha he compreshr nhi istart nhi hota compreshr ki rnig Stating bol rhi he comn nhi bol rhi kiya krbh he kiyo esa huaa kis ke kardh esa nobt aayi btana tiren dulab a c he btana pileeg
Ok Bro
Acha bolte ho but utnabhi long ny Or ya utna short na ho
Ok brother
Bhai hmare ac ka compressor krab ho gya hai abb ac new lena chaiye ya compressor dalvana chaiye purane mai
compresser lagaye, agar ac mentione hai to
@@AMRESH11TECH kafi log keh rhe hai ki compressor jyada time chlta
Nhi chalta
Plz btao ji
@@happysaini3813 compressor change karna behter
Suction ki valve bnd nhi kroge to presser suction se aayga hi or rotary compressor ma kisna bta diya aapko piston hota ha k
😂😂
mara jo compressor hy bohot jeda hot hota hy plz reply.
Voltage ⚡+ Capsiter + servicing + capillary ✅ check kariye
sab new hy clean hy compressor old hy 4 years pimping ok
Gas vi thik he or capeciter vi change Kiya par compercer trip hota he Kya kare standing presser thodi Jada he 150 psi r 22 gas he Kya probalam ho Sakta hai
Votage chek kiy ho
New matches mai same problem aarha hai
Ok Aur details me bataunga next video me
Outdoor fan thanda haba deraha hai indoor thanda Nahin horaha
gas pressure low hoga
OK ,koi dusra kaaran ?
You are right the technician told the same and he said to check the leakage point and fill the gas .
@@samirpradhan4915 Gas choking and pumping failure of compressor
👍👌🤝
Beta time ke sath sath party ka bhi nuksan kiya
Sir Aap video bahut long banate hai
Ok ab short karunga
bhai ji maine samsung ka inverter ac liya he 4 mahine huva hai aur compressor jab slow hota hai to avaj bahut karta hai aur vibration bhi hota hai to compressor kharab hoga?
Cooli hota hai ke nahe hota hai speed me aur low speed me
Pumping shi hai par pistan ghaske khatam hogya hai uska
kabhi kabhi oil kam hone ki vjah se bhi pumping down ho jati he
Ye lpgcan kitne ki hai
50 saudi Riyal
300 Nitrogen ka pressure denge