[Eng Sub]KYORITSU KEW 2046R AC/DC CURRENT TRUE RMS DIGITAL CLAMP METER- A REVIEW

Sdílet
Vložit
  • čas přidán 27. 07. 2024
  • Hello everyone! This is a review of my Kyoritsu KEW 2046R. Also featured in it, are some of my other clamp meters which I used for reference and comparison, including my Fluke 116 DMM, Fluke 324, Hioki 4367, KEW 2127R, and KEW 203. If you liked this please consider subscribing. The video is time stamped with chapters for easy navigation. Thanks for watching and your support!
    00:00 Disclaimer
    00:10 Intro
    01:26 Specifications
    03:45 Parts & Functions
    05:20 Test Leads
    06:58 Backlight & Data Hold Button
    07:56 Clamp Sensor
    08:35 Non-Contact Voltage (NCV) Detection
    09:27 Side Rubber Moulding & Back Details
    09:55 2-AAA Battery Compartment
    TEST
    10:10 AC voltage & Frequency (KEW2046R VS FLUKE 116)
    10:51 AC Inrush & Running Current (KEW2046R VS KEW2127R)
    11:34 DC Voltage (KEW2046R VS FLUKE 116)
    12:14 DC Current (KEW2046R VS HIOKI 4376)
    13:22 Capacitor Test
    14:18 Resistor & Continuity Test
    15:02 Diode Test
    TEMPERATURE TEST USING
    FLUKE TYPE-K THERMOCOUPLE
    15:25 Temperature (KEW2046R VS FLUKE 324)
    16:47 LIKES
    17:35 DISLIKES
    18:57 Closing Thoughts
    19:54 End
    Music:
    Accralate - The Dark Contenent by Kevin MacLeod is licensed under a Creative Commons Attribution 4.0 license. creativecommons.org/licenses/...
    Source: incompetech.com/music/royalty-...
    Artist: incompetech.com/
    MIST - by Odonis Odonis
  • Věda a technologie

Komentáře • 15

  • @starobinful
    @starobinful Před 2 lety +2

    Thanks a lot !!
    Do you know which Japanese clamp meter would have LoZ feature or relative zero ? Thanks

    • @pakito9947
      @pakito9947 Před 2 lety

      Loz o filtro de paso bajo las pinzas hioki los traen

    • @pakito9947
      @pakito9947 Před 2 lety +1

      HIOKI CM 4371-4372-4373-4374-4375 y 4376 todos estos modelos loz a filtro de paso bajo

    • @ramschannelreviews
      @ramschannelreviews  Před 2 lety

      If you mean low impedance voltage measurements, like the LoZ of Fluke 117 & Fluke 116, I don't know of any Japanese clamp meter. For relative zero, if you mean Zero Function Button before making DC current measurement, I think most, if not all, DC current clamp meters have that including the Japanese brand Hioki CM4376 & this KEW2046R.

  • @sultanhong
    @sultanhong Před rokem +1

    I saw you had a Hioki CM4376 clamp meter, how do you compare the Kyoritsu KEW 2046R and Hioki CM4376?

    • @ramschannelreviews
      @ramschannelreviews  Před rokem

      Thanks for watching. The Hioki CM4376 is superior to the Kyoritsu 2046R. This is expected as the CM4376 cost more, has built in Bluetooth adapter, thinner jaws, DC power (kW) function, better backlight implementation, and inrush current (both instantaneous peak & RMS) to name some examples. It lets you view voltage and current waveforms on the Hioki Gennect Cross app, as well. You can compare their specs for more details on their individual websites.

  • @BPadventure
    @BPadventure Před 2 lety +1

    Shout out Sir Ram

  • @waiedragon9107
    @waiedragon9107 Před 2 lety

    kyoritsu 2046r needs calibration??

    • @ramschannelreviews
      @ramschannelreviews  Před 2 lety

      Thanks for watching. If you mean the low reading when taking low AC current as noted in the video, yes I think my unit may need to be calibrated for that. To be fair, it's possible it's just my unit. All other functions were good.

    • @waiedragon9107
      @waiedragon9107 Před 2 lety

      @@ramschannelreviews owh. because i also have that kyoritsu 2046r. I tried on the fan in my house and Tried looking at the meter I couldn't get a reading. maybe the 2046r can't display a low ac current (A) reading

    • @waiedragon9107
      @waiedragon9107 Před 2 lety

      @@ramschannelreviews In your opinion, does my clamp meter 2046R need to be calibrated? because I just bought the meter clamp.

    • @ramschannelreviews
      @ramschannelreviews  Před 2 lety +1

      @@waiedragon9107 Just now, I took AC current readings of my stand fan with the KEW 2046R and a Hioki CM3289. The KEW2046R reads zero, while the CM3289 reads 0.30A (300mA). The KEW2046R apparently wasn't specified to measure current below 1Amp. This isn't surprising for an AC/DC current clamp meter. For instance, my Hioki CM4376, also an AC/DC current clamp meter, is not specified to measure below 1Amp. For AC current only clamp meters, like the KEW2127R & the Hioki CM3289, measuring below 1Amp AC is often possible. In my video, the 2046R measured 1.3A AC when compared with the KEW Snap 203.

    • @ramschannelreviews
      @ramschannelreviews  Před 2 lety +1

      @@waiedragon9107 As to the question of calibration, my opinion is if you have convenient, economical access to it then why not? My thoughts on this is purely suggestion, based on my comparison of the 2046R with the current readings of my other clamp meters on low value current. However, there may be more factors to consider, which I am not aware of, before calibration is really warranted. Perhaps you can compare the readings of your 2046R unit with other clamp meter readings first, just to check as an initial step.