Hi, now turns the spindle. Have all values transferred from the old original Huanyang VFD to the Yaskawa. It can be controlled by software. Autotuning does not work, no idea why, but that is not bad either. Here´s the data: E1-01 230V E1-04 300Hz E1-05 220V E1-06 300Hz E1-07 2,5Hz E1-08 13V E1-09 0,6Hz E1-10 6,6V E1-11 0Hz E1-12 0V E1-13 220V E2-01 10A E2-02 20Hz E2-03 4A E2-04 2 E2-05 2,134Ohm E2-06 19,6% E2-11 3kw
• Motor data entered to T1 parameters does not match motor nameplate. Enter the correct data.
• Restart Auto-Tuning and enter the correct information.
Hi, now turns the spindle. Have all values transferred from the old original Huanyang VFD to the Yaskawa. It can be controlled by software. Autotuning does not work, no idea why, but that is not bad either.
Here´s the data:
E1-01 230V
E1-04 300Hz
E1-05 220V
E1-06 300Hz
E1-07 2,5Hz
E1-08 13V
E1-09 0,6Hz
E1-10 6,6V
E1-11 0Hz
E1-12 0V
E1-13 220V
E2-01 10A
E2-02 20Hz
E2-03 4A
E2-04 2
E2-05 2,134Ohm
E2-06 19,6%
E2-11 3kw
A1-02=???
A1-02=2 open loop vector control