@@electricalgurukul can you kindly guide me, i got job in ksa for operation also. They are giving cat4 ppe dress that protect from arc falsh of 40cal/cm2 but arc flash temperature is 20,000°C. My question is that is its enough to save me in cause anything bad happen? I am getting anxiety
Nice information!
Bohot badhiya...good work..sir ji..
Good representation of ring main unit
What is the difference between vcb and rmu
Please make one video at it
bhaiya bhut acha smjhaye ho aap
Sir Bahut achhe se bataye aap RMU ke bare me
Thanks for the information sir
Good Information Brother 💐💐💐💐
Great job 👍👍
Make video on pre commissioning test of RMU.
Hello. I have test for rmu. I will send to you
Good
Good job sir... ❤️🙏
Kindly include operation of interlocking sliding switches
Masha Allah mabrook good explanation 👍
Great job bro👍
चांगल्या पद्धतीने स्पष्टपणे शिकवले आहे सर.
Is there any interlocking provided between isolator and breaker, so that no one can off isolator in on condition before breaker
Thanks good ❤
Good explained thanks.
Good job bro
We too have a similar transformer it gets earth frequently van u share the reason
Good working priktical
Great sir
Nice Bhai jii
Good explanation sir
Nice bro
Sir rmu me lbs swith dcs se operate hota hai kya
Nice
Good wark sir
first we break the isolator then the circuit breaker .
Dheraj bhai seimens or c&s ke rmu ko operate kaise kre ye bhi btao. Or sub station me kaise operate kre
Make more videos on operation
❤❤❤❤
Very good
Yeh RMU kaunsa make hai
ABB
Siemens
Schneider
Etc.
RMU aur CSS is same or different?
Super sir
Sir is copper earthing in 2 numbers of 3 meter is enough for RMU
Transformer ka WTI, OTI & Buchholz relay ka protection h...??? Please answer.
I have safeplus ABB make , type: VVV+ model RMU
Yes, for internal protection of transformer we use Buchholz relay.
Thanks you
Thanks 🙏
Can i get a video about shutdown
Sir RMU ki contol wiring k bare mein video banyo
thanks 🙏
Sir what is the basic deference in between indoor switch gear and R
Mu.
Indoor switch will be inside outdoor will be outside...
You and your question...
@@transientmatter6088 what do you mean you and your question.
please share the details of this product
Informative video, but no English or subtitle?
If we charge both incoming feeder then what will happen.
If both sources are different then it may trip the related feeders on heavy S. C
How to connecting in 240supply wiring how plz tell in video
सर खुला परिपथ बन्द परिपथ किसे कहेगे रमयु मे
Sir up ht panel may operation & maintaince karte hai??
Operation
what is the difference between a LBS & a Breaker?
Bro lbs us isolator which is just a switch and don't work on onload condition and breaker is a switch work on load condition.
How much dc volt need for controling?
24volt
Is it live? You are working on live rmu?
No, it's spare
@@electricalgurukul does protective suit provide us full protection from blast?
@@asimiqbal25 Arc flash PPEs use during operations.... Probability of protection is high in this case
@@electricalgurukul can you kindly guide me, i got job in ksa for operation also. They are giving cat4 ppe dress that protect from arc falsh of 40cal/cm2 but arc flash temperature is 20,000°C. My question is that is its enough to save me in cause anything bad happen? I am getting anxiety
hope theres english sub
SO RMU IS BASICALLY ATS
But you are not telling us the basic reason for using RMU.
सर य़ह कहाः पर हैं???
11 KB input 2 output connection1 kaise
सर में और अच्छी तरह से समझा सकता हूं???
Hi
Sir pls apna namber send me
Subscribe sir
No No safety fast
Explain english
Is it not interlocked for sequence of operation of isolator, earth switch and CB?
Yes it is