FIRE ALARM || CONVENTIONAL FIRE ALARM PANEL || TYY CONVENTIONAL PANEL ||

Sdílet
Vložit
  • čas přidán 12. 11. 2021
  • Lazada: bit.ly/3P9kwxN
    Everything about Conventional Fire Alarm Panel well be discuss in this video.
    If you are a beginners or want to know more, especially how the systems work, then this is for you.
    Topics:
    1. How the conventional Fire Alarm Panel Works.
    2. What is the purpose of End Of Line (EOL) Resistor.
    3. What is the correct termination of Manual Call Point (MCP) and BELL.
    If you learn something in this video, Please do Like and Subscribe to this channel for more FDAS knowledge. \\
    If we can reach 1000 subscriber, I will cover how the COOPER, GST and Morley-iAS Systems work.
    From Termination, design and programming.
    With programming software.
    Thank you!!!!
    PANEL:
    www.lazada.com.ph/products/i3...
    / safetytechnician
  • Jak na to + styl

Komentáře • 111

  • @DavidMoorexy
    @DavidMoorexy Před měsícem

    COMPLETELY WRONG. IT IS NOT CURRENT SENSING. YOU SHOULD CHECK THE CIRCUIT FIRST.

    • @whatever.TV88
      @whatever.TV88  Před měsícem

      Thank you. ikaw na check mo na?

    • @DavidMoorexy
      @DavidMoorexy Před měsícem

      @@whatever.TV88 yes wrong

    • @DavidMoorexy
      @DavidMoorexy Před měsícem

      @@whatever.TV88 if you can tell me the IC number then i will tell you you are wrong.

    • @whatever.TV88
      @whatever.TV88  Před měsícem

      @@DavidMoorexy Paano pala Master para ma correct ko.

    • @DavidMoorexy
      @DavidMoorexy Před měsícem

      @@whatever.TV88 i know what im talking about. all IDC circuit for conventional FACP is not current sensing. The EOL resistor is designed to comply for NFPA72 requirements to have a surpervised curcuit that monitors short circuit, open circuit and Alarm status but the circuit is not designed with current sensing. the answer is can be known thru ic number of IDC. i have been working IDC design. so i know im right.

  • @fredroble4830
    @fredroble4830 Před 2 lety +1

    Salamat sir

  • @meldiskarte7561
    @meldiskarte7561 Před rokem

    Salamat idol alam Kona

  • @alexandercellon971
    @alexandercellon971 Před rokem +2

    Master ok SA isang zone dalawang manual call point na tyy. 4wires. Po. Yng wiring. Sa terminal. Niya isang zonel pwd paanu po I termination po. Slmt master

    • @whatever.TV88
      @whatever.TV88  Před rokem

      2 wires lang kay TYY Master, naka patallel ang termination., kung ibang brand e install mo pwede naman peru kung dry contact type na MCP yan need mo ng trigger resistor kace shorted po lalabas nyan.

  • @rodforiogabutero4117
    @rodforiogabutero4117 Před 2 lety

    Boss paano ikabit qng smoke detector fire guard yong bracket niya 1234 09-35v. Tapos gamit ko 24 v. Na conventional panel TYY salamat

    • @whatever.TV88
      @whatever.TV88  Před 2 lety

      Check mo muna bai kung pwede ba e two wires ang installation sa emu fireguard. wala pa naku na try

  • @jonahguitarchannel3504
    @jonahguitarchannel3504 Před 6 měsíci

    Hello.idol ask ko lang if may natirang bakante pang zone or sounder need bang lagyan ng resistor un ?

    • @whatever.TV88
      @whatever.TV88  Před 6 měsíci +1

      Yes po. Dapat andjan palage ang EOL Resistor

  • @joeydegamo8727
    @joeydegamo8727 Před 2 lety +1

    Bos pag dalawang panel pwd ba e synchronised ang Bell to bell anong gamit na ma synchronised sya?

    • @whatever.TV88
      @whatever.TV88  Před 2 lety

      Dito sa panel natin Master conventional to kaya need mag add ng relay. bali double input single output and relay na e design

  • @alexandercellon971
    @alexandercellon971 Před 2 lety +1

    Cooper na man sir☺️☺️

    • @whatever.TV88
      @whatever.TV88  Před 2 lety

      pagmakahiram tayo panel Sir. hehehe. Wala na kace tayo ngayun sa Cooper.

  • @alexandercellon971
    @alexandercellon971 Před rokem

    4 zone panel po ba Ilan. Kaya sounder or horn strobe Kaya po ba 6pcs bell or strobe slmt master

  • @renaldtejada8497
    @renaldtejada8497 Před 6 dny

    master halimbawa umabot device mo ng 40 isang zone isang 10k ohms pa rin ilalagay?

    • @whatever.TV88
      @whatever.TV88  Před 5 dny

      sa specs master up to 30 device lang. baka magkaka fault na yan. di ako sure.

  • @francisgustilo2015
    @francisgustilo2015 Před 2 lety

    hi boss, pwede ko kayo kunin for company in-house training and project installation?

    • @francisgustilo2015
      @francisgustilo2015 Před 2 lety

      maganda po pagkaturo nyo lalo sa mga beginner katulad ko

    • @whatever.TV88
      @whatever.TV88  Před 2 lety

      Pweding pwede Sir. contact mo lang ako. 09566756808

  • @meldiskarte7561
    @meldiskarte7561 Před rokem

    Sir good day ayaw man mag bato Ng signal yong smoke at sa Ka push button,bkit sir? Anong gawin

  • @eddavebongcawel4615
    @eddavebongcawel4615 Před 2 lety

    Bossing para San po Yung non-laching na push button sa TYY control panel ..

  • @sellihca32moriez22
    @sellihca32moriez22 Před rokem

    Sir sa bell namo Kay wala butangi...pwede BA sya madamge Ang bell.

    • @whatever.TV88
      @whatever.TV88  Před rokem

      coil kace ang bell kaya need mo ng diode para ma direct and current. may posibility na ang masira ay ang output ng panel.

  • @user-rd9oc2vv2y
    @user-rd9oc2vv2y Před měsícem

    Sir may EOL resistor po ba sa sounder natin?

  • @ivancruda9445
    @ivancruda9445 Před 2 lety

    Sir, ganda po ng pagka turo niyo po,
    tanung ko lng paano po pag mag iinstall po ako ng 3pcs Alarm Bell 10" at 8pcs na 6" na Alarm Bell, at nabanggit niyo po upto 4 pcs Alarm Bell lng kaya ng Panel.
    Ano po pwed gawin?

    • @whatever.TV88
      @whatever.TV88  Před 2 lety +1

      Salamat idol.
      Para makapag install ka ng mas maraming output devices like Bell and Strobe light, need mo ng separate supply para sa kanila. tapus gumamit ka ng relay (SPDT) type na 24V with Diode dapat. marami sa electronics store yan. kung di mo kabisado ang connection at termination, message ka sakin.

    • @franconap2871
      @franconap2871 Před rokem

      @@whatever.TV88 sir magandang araw po pwede din po ba ako magpatulong hihingi din po kase sana nang guide para sa connection at termination para makapag kabit po nang maraming sounder sir

    • @whatever.TV88
      @whatever.TV88  Před rokem

      @@franconap2871 Dali lang yan Master. need mo lang ng extra power supply na may back up battery din dapat kace kung walang back up battery bagsak po yan sa standard.

  • @tatajungay2790
    @tatajungay2790 Před rokem

    Series ba yan ang resistor sa mps master

    • @whatever.TV88
      @whatever.TV88  Před rokem

      Pag TYY MCP gamit mo no need na ang Resistor Master

  • @jeffvales9962
    @jeffvales9962 Před 2 lety

    anong specs ng diode master sa bell?

  • @rodeleenmontehermoso7680
    @rodeleenmontehermoso7680 Před 9 měsíci

    Anu ang problema kapag nag test ng sd tapos umilaw hindi naman nag trigger ung strobe anu po problema.,

    • @whatever.TV88
      @whatever.TV88  Před 9 měsíci

      Same brand ba ang Detector at ang Control Panel?

  • @tatajungay2790
    @tatajungay2790 Před rokem

    Same p yan panel sa assesment namin bakit ayaw gumana s1 isang bel at z1 isang detector at mps.. At may resistor naka series sa bell at meron din ressitor sa una bakit ayaw pumalo ang bell try ko pinalo ung mps nag alarm cignal. Lang ung panel. Bakit hindi tumotunog

    • @whatever.TV88
      @whatever.TV88  Před rokem

      Diode dapat nakalagay sa Bell. may polarity yun

    • @whatever.TV88
      @whatever.TV88  Před rokem

      kahit walang resistor ang zones pwede yun. may option ka djan na di gamitin ang EOL master. kung marami pa kayong di natutunan. punta kayo sa office. budget meal lang ang bayad.

  • @paopawliba6740
    @paopawliba6740 Před rokem

    Same lang po ba sila ng brand na arrow sir.??

  • @rjlcircuitdiagramsystem489

    Nagtetraining po ba kayo ng actual sir?

    • @whatever.TV88
      @whatever.TV88  Před 2 lety

      sa ngayun wala pa Sir. may inaayus lang ako para magka TESDA tayo. sayang kace

  • @markangeloimporta1614

    4:25 principle of operation ng conventional fire detection alarm system/paano gumagana ang fdas

    • @whatever.TV88
      @whatever.TV88  Před rokem +1

      Current driven yan. wala pong data na binabato nya. nag depende yan sa current na dumadaloy sa Zones.

    • @markangeloimporta1614
      @markangeloimporta1614 Před rokem

      @@whatever.TV88 saan ko po siya sir pwede pag-aralan, may link ka po ba sir na tungkol sa conventional fdas?

    • @whatever.TV88
      @whatever.TV88  Před rokem

      @@markangeloimporta1614 Based on my experience and curiosity lang lahat yan Master. Kung gusto mo matoto nyan lahat pwede ka mag apply sakin 1on1 training. Paid po yun xiampre peru sabi ko sayo a decade of experience ang makukuha mo sa akin. pm ka lang.

  • @jhebscubico1990
    @jhebscubico1990 Před 2 měsíci

    sir paano kng magtrigger ang MCP at hindi nag alarm ang FACP. ano po problema kapag ganon?

  • @chitotorculas5892
    @chitotorculas5892 Před 2 lety

    Ser bakit ang tyy mag ka troble kapag madame ang bell

    • @whatever.TV88
      @whatever.TV88  Před 2 lety +1

      4 bell lang ata nakalagay sa specs ng panel

  • @bikolexpress2794
    @bikolexpress2794 Před rokem

    Location nyo master.pwede ba magtraining syo

  • @meldiskarte7561
    @meldiskarte7561 Před rokem

    Bosh paano mag wiring sa bell at saka manual call point

    • @whatever.TV88
      @whatever.TV88  Před rokem

      Si bell Idol may sariling terminal yan sa panel yun ang output terminal. c MCP naman pwede na yan sabay sa mga SD.

  • @arvievaldez977
    @arvievaldez977 Před 2 lety

    Lods di pa po aq naka ranas ng ganyan kaya nanunood aq

  • @user-rd9oc2vv2y
    @user-rd9oc2vv2y Před měsícem

    Sir ask ko lang po paano po kung Yung connection na galing sa panel board ay line to line connection papaano po ito e connect sa facp ?

    • @whatever.TV88
      @whatever.TV88  Před měsícem

      Di ko ma gets ano ibig mong sabihin sa line to line Master. pa explain ng maayos

    • @user-rd9oc2vv2y
      @user-rd9oc2vv2y Před měsícem

      @@whatever.TV88 diba Meron line to ground connection Meron din line to line connection na kadalasan sa urban area..or single phase three wires po..ang tanung ko po sana po masagot ninyu Yung connection po sa panel board ng fire alarm(facp) paano po e connect ang linya na parehong may 110 volts each?

    • @whatever.TV88
      @whatever.TV88  Před měsícem

      @@user-rd9oc2vv2y ahh okay. sa power source pala tinutokoy mo.
      tatlo po terminal nyan parihu lang yan sa ibang mga appliances mayron Hot Neutral Ground.

  • @alexandercellon971
    @alexandercellon971 Před rokem

    Good day master capacity Ng isang zone Ilan divice po pwd.

    • @whatever.TV88
      @whatever.TV88  Před rokem

      30 mximum sa TYY 4 BELLS per output

    • @alexandercellon971
      @alexandercellon971 Před rokem

      Bali sir Kada zone Ng bell apat ang Kaya gnun po ba Yun slmt master

    • @alexandercellon971
      @alexandercellon971 Před rokem

      Bali 8 Kaya na bell sa Tyy na 4zone panel sir Yun po ba Yun slmt

    • @whatever.TV88
      @whatever.TV88  Před rokem

      @@alexandercellon971 bali may 4 zones ang panel na to maximum of 30 detectors per zone. at may 2 output lang sya na kay ayun sa manual 4 bells per output

  • @MrJeonard1985
    @MrJeonard1985 Před 10 měsíci

    boss panel zone 1, 2, 3, 4, 5 direct with resistor lang 1k walang nakakabit na SD, nagaalarm sya na fire. then yung ibang zone 6, 8,9, 10,11, 12 with resistor normal. ano kaya problema?

    • @whatever.TV88
      @whatever.TV88  Před 10 měsíci

      Sir. Trigger resistor po ang 1k. hindi sya EOL. Dapat po 10k ang nilalagay mo.

    • @MrJeonard1985
      @MrJeonard1985 Před 10 měsíci

      @@whatever.TV88 kung 10k ko kasi nilalagay katulad resistor ni sounder ng aalarm sya ng OC.. kung 1k normal po sya sa ibang zone.. iba naman fire

    • @MrJeonard1985
      @MrJeonard1985 Před 10 měsíci

      Posible ba defective na ang terminal?

    • @whatever.TV88
      @whatever.TV88  Před 10 měsíci

      Not Sure. bihira lang naman masira terminal. try mo recta sa terminal ang 10k kung mag okay.
      @@MrJeonard1985

    • @whatever.TV88
      @whatever.TV88  Před 10 měsíci

      Ano brand panel mo Sir?
      @@MrJeonard1985

  • @user-is4qk8id9k
    @user-is4qk8id9k Před 11 měsíci

    Sir bakit Hindi Humana Ang manual pull swicth

    • @whatever.TV88
      @whatever.TV88  Před 11 měsíci

      Anong MCP gamit mo Master? panoorin mo ulit paano mag install ng MCP.

  • @paanovlog3296
    @paanovlog3296 Před 11 měsíci

    Magkano po yan sir facp?

  • @jedagudo6127
    @jedagudo6127 Před rokem

    Sounder open sir khit tama connection

    • @whatever.TV88
      @whatever.TV88  Před rokem

      Check End Of Line Resistor. ilang sounder na ba naka connect?

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 Před 9 měsíci

      Sir patulong Naman po, bakit naka open circuit parin kahit nagpalit na ko nang mga resistor.. Wala po akong smoke detector at heat detector, bell lang at mcp

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 Před 9 měsíci

      ​@@whatever.TV881zone lang po Ang control panel ko

    • @whatever.TV88
      @whatever.TV88  Před 9 měsíci +1

      Try mo muna lagay ang mga resistor direct sa Zone terminal na walang load.@@leonimarcaquilala3381

    • @leonimarcaquilala3381
      @leonimarcaquilala3381 Před 9 měsíci

      @@whatever.TV88 maraming salamat po, try ko po bukas

  • @marvinsotero8385
    @marvinsotero8385 Před 2 lety +1

    hindi claro ung pagtorumo brand mahina

  • @kokseahteo1716
    @kokseahteo1716 Před 10 měsíci

    So LAZY! NO ENGLISH SUB TITLES!!!!!!!