Rotational Viscometer (VG-Rheometer) Test - Basic Mud School

Sdílet
Vložit
  • čas přidán 9. 04. 2020
  • Let's Learn more about How to measure Rheological Properties like Plastic Viscosity, Yield Point and Gels?

Komentáře • 18

  • @keiramorgan6967
    @keiramorgan6967 Před 2 lety

    Kandungan video sangat baik, tahniah

  • @chemistrylearn33
    @chemistrylearn33 Před 4 lety +1

    شكرا جزيلا باشمهندس

    • @MohamedElshora
      @MohamedElshora  Před 4 lety +1

      العفو تحت امركم في اي وقت باذن الله

  • @nadyaaprilianti5123
    @nadyaaprilianti5123 Před 2 lety +1

    Character In the video It's great, I like it a lot $$

  • @nhanpham9698
    @nhanpham9698 Před 2 lety

    You try to give the video more brightness it will be great if you do

  • @greenworld6372
    @greenworld6372 Před 2 lety

    Hello Mr.Mohammed... Can you guide me where can I get your videos about Advanced Mud school...Thank you.

  • @raniamontazeri87
    @raniamontazeri87 Před 3 lety

    Waalaikumsalam

  • @user-or4ln3qp8h
    @user-or4ln3qp8h Před rokem

    how do you do that?

  • @moustafaashraf4407
    @moustafaashraf4407 Před 4 lety +1

    ربنا يكرمك يابشمهندس محمد
    بس انا مش فاهم ال steps بتاعه حساب ال Gel strength فالو ممكن حضرتك توضحها اكتر

    • @MohamedElshora
      @MohamedElshora  Před 4 lety +1

      Gel Strength (10-sec/10-min) Steps:
      1. With red knob in bottom position, flip toggle switch to 600-rpm position (forward position). Stir mud sample for 10 seconds.
      2. Position red knob to the 3-rpm speed. When the red knob is in the middle position and the toggle switch is in low (rear) position -this is the 3-rpm speed. Flip toggle switch to off position. Allow mud to stand undisturbed for 10 seconds.
      3. After 10 seconds, flip toggle switch to low (rear) position and note the maximum dial reading. This maximum dial deflection is the 10-second (initial) gel strength in lb/100 ft2. Record on the mud check sheet.
      4. Pull toggle switch to high and position red knob to 600-rpm speed. Stir mud for 10 seconds.
      5. After 10 seconds, and while mud is still stirring, position red knob to the 3-rpm speed. Flip toggle switch to off position and allow mud to stand undisturbed for 10 minutes.
      6. After 10 minutes, flip toggle switch to low (rear) position and note the maximum dial reading. This maximum dial deflection is the 10-minute gel strength in lb/100 ft2. Record on the mud check sheet.