Eg4 6000 Xp All-in-one Solar System! Full Install! Extremely Affordable!

Sdílet
Vložit
  • čas přidán 19. 12. 2023
  • Eg4 6000 Xp All-in-one Solar System! Full Install! Extremely Affordable! OUR SOLAR EQUIPMENT...CLICK HERE: www.signaturesolar.com/?ref=c... COUPON CODE: Countryliving12 HARVEST RIGHT FREEZE DRYER: affiliates.harvestright.com/1... GROWERS SOLUTION: growerssolution.com/Countryli... DISCOUNT CODE: CountryLiving10.
    Solar and Electrical Equipment:
    EG4 6000xp Split Phase Inverter: signaturesolar.com/eg4-6000xp...
    Victron Multiplus 2: signaturesolar.com/victron-mu...
    Victron Smartsolar MPPT: signaturesolar.com/victron-sm...
    Victron Cerbo GX Comms Hub: signaturesolar.com/victron-en...
    Victron Cerbo Touch 50: signaturesolar.com/victron-en...
    Victron GX Touch Wall Mount: amzn.to/3ruaXR7
    Victron Lynx Distributor: signaturesolar.com/victron-en...
    Mini Rail Roof Mount: signaturesolar.com/asphalt-mi...
    Solar panel rail clamp: signaturesolar.com/end-clamp-...
    EG4 6500ex Off-Grid Inverter signaturesolar.com/eg4-6-5k-o...
    EG4-LL LiFePo4 Batteries: signaturesolar.com/eg4-ll-lit...
    Growatt SPF 5000 ES Off Grid Inverter: signaturesolar.com/growatt-5k...
    IMO PV Disconnect Box: signaturesolar.com/dc-disconn...
    Nader 200Amp Breaker: signaturesolar.com/nader-dc-c...
    Growatt Transformer: signaturesolar.com/growatt-5k...
    12 position electrical sub panel: amzn.to/3DVKZpZ
    4 gauge THHN wire: amzn.to/3pYrXuB
    4/0 and 2/0 Battery Cable: amzn.to/3QXfZgy
    Copper Battery Ring Terminals: amzn.to/3CLRK0y
    70 amp double pole breaker: amzn.to/3AvMVWp
    Safety switch: amzn.to/3FXCkHO
    conduit as needed
    Simpson Flip Toggle mounting hardware: amzn.to/47AFhtw
    Ticonn IP67 Electrical Box: amzn.to/3YBFKHX
    Dinkel Terminal Blocks: amzn.to/3QMq6Yj
    DIN rails: amzn.to/3OxbpFS
    Hardie backer board
    Pike Industries Bus Bar: amzn.to/3R3bSzs
    EG4 Brightmount Rack: signaturesolar.com/eg4-bright...
    Panel calculation site: www.photonik.solar/string-vol...
    Parts list:
    1 1/2" conduit
    90° conduit elbows: amzn.to/3qL33Tm
    conduit LB boxes: amzn.to/45SEWAR
    conduit threaded connectors: amzn.to/3OTCbZc
    lock nuts: amzn.to/3P3bCAO
    thread protectors
    Conduit weatherhead: amzn.to/3L61WnV
    Conduit straps: amzn.to/45S6iHf
    grounding rod: amzn.to/3LspxzF
    ground rod clamp: amzn.to/47Yzi1O
    sub panel: amzn.to/3DVKZpZ
    AC breakers: amzn.to/3AvMVWp
    Safety disconnect switch: amzn.to/3FXCkHO
    Grounding bar: amzn.to/3LspDY3
    Neutral Lugs: amzn.to/45U4Iog
    Ring terminals: amzn.to/3EfLRGK
    Ferrule Kit: amzn.to/3sCgh5p
    PVC Electrical Glue: amzn.to/3OWoLvz
    1/2" flexible conduit: amzn.to/45OyXNt
    Liquid tight conduit connectors: amzn.to/45OyXNt
    Distribution protection box: amzn.to/3P2t7Bq
    Dinrail: amzn.to/3OxbpFS
    Dinkel terminal blocks: amzn.to/3QMq6Yj
    DC breakers: amzn.to/3L4iPQ0
    Surge protection device: amzn.to/3qTDuPQ
    Combiner box: amzn.to/3YBFKHX
    Solar inline fuses: amzn.to/3PnRZVK
    Flip toggle mounting hardware: amzn.to/47AFhtw
    MC4 connectors: amzn.to/3qWiW9s
    WIRE! : amzn.to/3pYrXuB and amzn.to/3QXfZgy
    Tools below ↓↓↓↓↓
    Tools Used for Our Solar Install:
    Klein Clamp Meter: amzn.to/3sBK7Hc
    Step Drill: amzn.to/459TWKE
    Cable Stripping Knife: amzn.to/3pkWlOO
    Klein Wire Stripper: amzn.to/3Ib3tWD
    Klein Crimping Tool: amzn.to/3E8gk9P
    Large Gauge Hammer Crimper: amzn.to/3ro7rVZ
    Large Gauge Wire Cutter: amzn.to/3lqUiI2
    Ferrule Crimping Tool with Ferrules: amzn.to/32RgJQj
    Copper Lug Set: amzn.to/3EfLRGK
    1.5" Wrench: amzn.to/3o9gh8c
    24" Breaker Bar: amzn.to/3rrMQAk
    1.5" Socket: amzn.to/2ZIqnn7
    All links are affiliate links that we earn a commission from. There is no extra charge for you at all but it helps support our channel.
  • Jak na to + styl

Komentáře • 320

  • @CountryLivingExperience
    @CountryLivingExperience  Před 6 měsíci +3

    EG4 6000xp Split Phase Inverter: signaturesolar.com/eg4-6000xp-off-grid-inverter-split-phase/?ref=countrylivingexperience

    • @davefroman4700
      @davefroman4700 Před 5 měsíci

      Don't know if you came across this yet but if you are going to use two mppt's you want to do it on the master if you are going to have an imbalance.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      @@davefroman4700 I have not come across that. How have you come across or tested this info?

    • @davefroman4700
      @davefroman4700 Před 5 měsíci

      @@CountryLivingExperience From one of the other big reviewers online. Think it was Rob Prowse. Something about the Master wanting to be fully populated first though. The software is better able to balance the load that way supposedly.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci +1

      @@davefroman4700 Interesting. I had not seen his video. I haven't had any issues but I will look into it. Thanks.

    • @davefroman4700
      @davefroman4700 Před 5 měsíci

      @@CountryLivingExperience It makes sense to me because the master is managing the load.

  • @wilshawlynnstevens2980
    @wilshawlynnstevens2980 Před 6 měsíci +2

    Very nice! We just got our system up and running. It has been a bit cloudy but everything is looking positive so far.

  • @GavinStoneDIY
    @GavinStoneDIY Před 6 měsíci +7

    You covered a lot of ground on this video. Good work on this one. These are fantastic inverters.

  • @stevenfrazier8939
    @stevenfrazier8939 Před 6 měsíci +5

    For the hole where the battery cables come in try GB Flex Tubing 3/8" Split Flex Tubing. I got it at Lowe's. I used it for the same application on my EG4 18K PV battery in. It works great. If I knew I could post a picture I would.

  • @dangoras9152
    @dangoras9152 Před 6 měsíci

    Looks good I got one last week and still haven't changed over .. Its hard to leave outback and midnight classics but I will try it... Keep it up brother

  • @rickinge7682
    @rickinge7682 Před 6 měsíci

    Just picked up my xp and a single 14 kw wall mount battery 16 bifocal panels.Hope to install this spring as soon as it warms up.Love your channel, looking forward to your next one .

  • @bobcole3852
    @bobcole3852 Před 6 měsíci

    Thanks for a clear and concise video. I gotta build my power shed before I install mine but it's too cold to pour concrete.

  • @paul.phillips
    @paul.phillips Před 6 měsíci +1

    Thanks for the video, I have the EG4-LL v1 batteries also, didn't realize I will have to update firmware. I want to get a couple of these 6000XP's, the fun part will be getting the ~150lb Growatt off the wall.

  • @mnj5089
    @mnj5089 Před 6 měsíci

    Those look really nice!

  • @rroades
    @rroades Před 6 měsíci

    I bought 1 from current connected. In stock and arrives tomorrow, Sunday to Thursday, not bad

  • @amsohn1
    @amsohn1 Před 6 měsíci

    Thanks for sharing, this is great!
    Blessings ❤

  • @chrs1212
    @chrs1212 Před 3 měsíci

    Awesome video, thank you very much for the great detail and information!

  • @briandumont7619
    @briandumont7619 Před 6 měsíci

    Nice video. I have a pair arriving Friday along with 4 X Ruixu batteries. Ordered from Current Connected on Monday!

  • @carlosschmidt6035
    @carlosschmidt6035 Před 6 měsíci +1

    Great video!!

  • @rodneyhunt
    @rodneyhunt Před 6 měsíci +10

    I had to update all my (comm connected) batteries to get the charge parameters from PV to work correctly. When I only did host battery it did communicate but only showed part of my battery bank that was connected for battery comms. So PV charge was low until updates completed on my lifepower4 batteries. Good work!

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +3

      Thank you.
      I saw that on your video. I will probably do an follow up video based on my firmware update for the master battery. We will see what happens.

    • @rodneyhunt
      @rodneyhunt Před 6 měsíci +2

      @@CountryLivingExperience sounds good 👍

  • @armedmindset6778
    @armedmindset6778 Před 6 měsíci

    I ordered two of them to replace my Growatt 5000 es system. I am going to leave the growatts in place as an emergency backup to my offgrid house and use the new EG4 inverters as my main system.

  • @SimonReilly-cd3ck
    @SimonReilly-cd3ck Před 6 měsíci +5

    Thank you for your dedication , so helpful. There is one work around for the battery recognition issue . If you set your actual battery to LUX , this will allow you to change to lithium battery in the EG4 6000XP, dip switch o seems to work for this even though the manual says dip 16 . Ok then have a charming wonderful day .

  • @intDavid
    @intDavid Před 6 měsíci +2

    I would go with a larger breaker in the sub panel than 40 amps since the 6000xp supports 50 amp pass through - as long as your wires (AC in and out) are spec'd to handle the 50 amps.

  • @diySolarPowerFunWithRay
    @diySolarPowerFunWithRay Před 4 měsíci

    Awesome. Thank you. I'm installing mine this week. It's interesting that the inverter communication doesn't show the battery state of charge.

  • @AdamDeLay07
    @AdamDeLay07 Před 6 měsíci +5

    Thanks for sharing! I'm with you on those tiny screws! Horrible little things! I was hoping they would have hinged the door with latches like the 18kPV.

  • @joetripp123
    @joetripp123 Před 6 měsíci

    I ordered one of these for Black Friday along with 2 EG4 LLs batteries. Still waiting for them to arrive.

  • @joetripp123
    @joetripp123 Před 6 měsíci +2

    21:45 looking forward to the clarification on defining what to use as priority - solar, battery, utility. Thanks. I suppose as long as it optimizes for most efficient for the load at the moment that would be ok.

    • @dbf1dware
      @dbf1dware Před 17 dny

      And let me ask this (I think I know the answer though), if the priority is set to solar, battery, utility... if the grid goes down, does it still use the solar and battery. If I understand correctly, that is what is considered a hybrid system, and the info I've seen on these specifically say they are not hybrid. Any clarification would be great.

  • @joeking3966
    @joeking3966 Před 6 měsíci +1

    thank you for the great video! isn't this inverter off-grid only, so it's interesting to see the grid option showing up on the screen.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +2

      You're welcome.
      AC (grid power in) in works on all off-grid inverters. It is only when you get into selling back to the grid that you need a hybrid or grid-tie inverter.

  • @sciglassblower
    @sciglassblower Před 5 měsíci +2

    Always keep your last MC4 Connector at the Panels Disconnected while messing with wiring at MPPT Charger! Then you don't need to worry!

  • @colormaker5070
    @colormaker5070 Před měsícem

    I just bought the 2 6000xp to replace my 6500ex. I have been watching a few videos on install. Wills channel shows only 1 comms cable between the inverters not the 2 you used. I wanted to check to be sure. I have the Lifepower 4 with original firmware so I may have to upgrade the newest release for the 6000xp. I got some great info from your channel thank you for sharing.

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem +1

      Glad I could help.
      I have had the Sig Solar guys confirm that you need both cables connected.
      I have the V1 LL batteries and had to update all of them so I am sure you will have to update your Lifepowers.

  • @EastTexasHomestead
    @EastTexasHomestead Před 6 měsíci

    Great video. I'm watching and dreaming while I patiently wait for mine to ship and replace the 6000EXs.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      Thank you.
      Did you have an issue with your 6500ex's?

    • @EastTexasHomestead
      @EastTexasHomestead Před 6 měsíci +1

      @@CountryLivingExperience I've had quite a few issues since adding the 3rd. It's been a bit disappointing, but I'm hopeful for the upgrade :)

    • @stifflerjj4
      @stifflerjj4 Před měsícem

      I have a brand new eg4 6500 and before I hook it up would you suggest that I trade it back in for the 6000 XP

    • @EastTexasHomestead
      @EastTexasHomestead Před měsícem +1

      @@stifflerjj4 I'll let Eric give his opinion on the 6500s. I had the old 6000EXs. I'm glad I made the trade. :)

  • @Budz_alot
    @Budz_alot Před 6 měsíci

    Just ordered one and 20 400 watt panels

  • @dannydonnelly8345
    @dannydonnelly8345 Před 6 měsíci

    Great video! with 2 batteries the xp unit and the solar panels it would be closer to $5G not $3500, still an excellent price for a system that's expandable. I'm starting with 1 xp and 2 batt.

  • @stephanied143
    @stephanied143 Před 6 měsíci

    they keep coming up with better systems think I'm going to get these

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      They are running flawlessly right now and are very quiet.

    • @rroades
      @rroades Před 6 měsíci +1

      I bought the 6500-ex in June, and they’re obsolete. Yes, they work but out of production. You CANNOT buy 2 more to upgrade an installed system unless you want used, and expansion was part of my plan.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      @@rroades I understand. That can be frustrating when companies do that.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      @@rroades They may offer refurbished ones.

  • @TheRockingSockPuppet
    @TheRockingSockPuppet Před 6 měsíci +2

    Nice video. Please update us on the reliability of these in parallel as you run your house over time. I had a twin 6500ex system and had constant stability issues. I switched to an 18Kpv and it just works. However, two of these 6000XPs is more affordable and desirable if selling back is not desired…IF they are reliable. Looking forward to updates as you use them for your daily loads.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      Thanks. I will keep y'all updated.

    • @ssoffshore5111
      @ssoffshore5111 Před 6 měsíci

      So how do these play with the grid, being off grid inverters? Net metering has become a joke in most areas now (or will be soon if not, thanks to all the lobbying). Can you actually use these and still be tied to the grid? If so, how does that work?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +2

      @@ssoffshore5111 They take AC in from the grid to charge the batteries. They can also pass-through power to your house loads if you have your system set up like that. You cannot sell back to the grid with them. I use my solar like a generator. I keep the grid for extended cloudy periods (because I do not have enough panels or batteries yet) and just switch over manually when I want to use either solar or the grid.

  • @mdinning123
    @mdinning123 Před 6 měsíci

    Well done video as always. Will you be connecting grid input to pull from if needed? My question is for users that will need to connect up to the grid, I'm looking for the best way to run the grid input into some type of transfer/bypass switch so you could bypass the unit if needed and still power the house sub-panel.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      Thank you.
      I am going to leave it as an off-grid only system actually. I think Will Prowse may have touched on that some.

  • @dupre7416
    @dupre7416 Před 2 měsíci

    Dang this EG4 6000XP is sweet! Do you know if there will be any big updates coming in the next 18 months? I’m not quite ready for it at our off grid acreage but I’m excited to start working with modern gear. My current system is very much a cludged together monster. This tech has gotten so much better in the past five years. It’s a great time to be working with solar.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      It is really nice for sure.
      They may be coming out with a smaller hybrid like the 18k which will be the 12k.

  • @wilsonal66
    @wilsonal66 Před 3 měsíci

    great video!! covered just what i was looking for but one thing from your sub panel to your main panel how did you wire that up?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 3 měsíci

      Thanks. Glad it helped. I covered wiring the sub panel in a few other older videos. Try this one....czcams.com/video/-5w6b_2LxtQ/video.html and this one.....czcams.com/video/I2rbxKtx5cs/video.html

  • @stevenelson3540
    @stevenelson3540 Před 2 měsíci

    Great video! Next week I'll be installing 2 of these in connection with my 2 powerpro batteries -this video will be super helpful. One question: How do you deal with live PV wire if you needed to disconnect PV from the 6000's charge controller? It seems like it would be safer (& more convenient) to have your PV disconnects before your wire goes into the charge controller

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      Glad it was helpful.
      I still have another pv disconnect switch. If I disconnect the pv wire from the inverter, I just turn off the switch. It would be safer, you are correct.

  • @itmike23662
    @itmike23662 Před 6 měsíci

    Wooden chopsticks make great pointers when dealing with electricity.

  • @carlossantini
    @carlossantini Před 6 měsíci

    Another great video! What happened with the multipluses & Cerbo Gx setup? Removed and gave up on them?

  • @SetitesTechAdventures
    @SetitesTechAdventures Před 6 měsíci

    I'd probably get these if they offered a trade up program. Otherwise, I have to find someone to buy my 6500s when I am ready to switch. I still might consider and 18kPV though because it has 200A pass through so I could comfortably put everything on solar but with these the pass through is like 50A per inverter from what I read. I feel like these grid supported inverters should offer full pass through since the 18kPV shows its possible.

  • @northidahodreaming5657
    @northidahodreaming5657 Před 6 měsíci +1

    Good video.
    Seems complex however since you cannot easily set inverter for LFP batteries at first startup...and had to setup initially to lead acid?? Perhaps EG4 rushed this to market without having default set to EG4 LFP batteries? Perhaps your next video will explain this?
    For me, the relatively lower idle consumption of this inverter is a winning feature. The 6000EX-48HV idle consumption was just too high for those of us living off grid in the far north.
    Having all the breakers in the box is a real savings for sure.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      Thank you.
      It isn't complex at all. If you have newer batteries, there is no extra step. All that needs to be done is adding the new parameter to the old battery via a firmware update.
      The breakers are great as well as that low idle consumption for sure.

  • @theadventuresofarenaissancman

    FYSA. When using only two in parallel, you only need one communication cable (between the two inverters).

  • @TheJR914
    @TheJR914 Před 6 měsíci

    Nice update on your 6000xp . So what do you do with the eg4 6500’s ? Just purchase my eg4-6500 a year ago can afford to buy new ones😅. At least there are improving on the newer inverters lower power consumption, Wi-Fi app that’s informative and parallel connections. So keep up the good videos coming and have a wonderful holiday for you and yours.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      Thank you. I will use the 6500’s for a small cabin that I want to build on the property. They are ever improving their equipment which is nice.

    • @daddio7249
      @daddio7249 Před 5 měsíci +1

      @@CountryLivingExperience I bought an EG4 kit back in August. I work slow (71, did a ground mount) and just got finished last week. The 6,500's are working fine but two are needed for 240v. If I lose one I will not be able to power my submersible well pump and my hybrid water heater. Should have waited. Might just buy a 6000XP to have on hand.

  • @tjmooney4181
    @tjmooney4181 Před 6 měsíci +1

    Awesome thanks for the great video, are the inverters the ground neutral bond or is that at your main panel?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      You're welcome. The bond is in my main panel.

    • @tjmooney4181
      @tjmooney4181 Před 6 měsíci

      ​​@@CountryLivingExperience please excuse my ignorance, I thought the main panel was the 1st with the incoming power then sub panels were after? Is main just where the ground rod is connected directly?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      @@tjmooney4181 Mine is an off grid system. It is wired differently. You'll have to look at my older videos to get all the info.

    • @tjmooney4181
      @tjmooney4181 Před 6 měsíci +1

      @@CountryLivingExperience great thank you. I'm curious because I have very similar system but use the 1st breaker load center as the main with the ground neutral bonded and separated them in the sub panel (which is the old main panel in the house with all the breakers)

  • @vt20247
    @vt20247 Před 4 měsíci +2

    Why not just drill a 2x4 to the wall as supporting the device while mounting it? Lift it up and rest itvon the 2x4 and that should allow you to secure the devices!

  • @georgeokunade2563
    @georgeokunade2563 Před 9 dny

    Can you make a list of solar kits including panels that I need for the 2 Inverters

    • @CountryLivingExperience
      @CountryLivingExperience  Před 9 dny

      Every project is unique. I have no idea what you need for your project so I cannot really suggest anything.

  • @jasonemery570
    @jasonemery570 Před 6 měsíci

    Happy new year. Do these eg4 batteries have a place to hook up both inverters? Thank you

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      Happy New Year. You will need some sort of common buss bar to hook up multiple inverters.

  • @Darren-C
    @Darren-C Před 2 měsíci

    Hey boss. These are just the calculations I needed. Thanks for the explanation! I’m building a larger electrical mobile unit out of an enclosed trailer I’ve converted to be powered by the 6000xp with 10.2kwh server no alternator charge tied. My biggest question is grounding the system in a mobile application with no grid tie. Is grounding to the frame fine because of wood blocks and rubber tires. Or do I need to tie the ground to a rod at every location. I’m worried times I’ll be around pavement only. Thanks again boss!!

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci +1

      You're welcome. Glad it was helpful.
      Honestly I am not well versed on mobile systems. The best channel for that is Explorist Life...www.youtube.com/@EXPLORISTlife. Nate does a great job explaining van systems.

    • @Darren-C
      @Darren-C Před 2 měsíci

      @@CountryLivingExperience Yes sir. Thanks

  • @timcraig8279
    @timcraig8279 Před 2 měsíci

    Are these 480VOC per mppt on the unit or 480voc for both?

  • @daviso4954
    @daviso4954 Před 6 měsíci

    I just purchased a complete system, 2 6000xps, 20 400 watt panels, and 4 li LL batteries. I am in the process of the setup and your video was super helpful. Thanks for all of your work! I do have on question, does the battery input cables go to both AIOs? I have two sets of battery cables in my packet. Do you connect both + cables to the battery buss bar or do you come out of buss bar with one cable and then split into two cables? Thanks again.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      Awesome, you're welcome.
      I am not sure what kit you bought so I don't know exactly what they gave you. You do need battery cables for each inverter and those in turn must be connected to the battery buss bars. I don't know f you have the battery rack with integrated buss bars or other external buss bars or both (like me).

    • @daviso4954
      @daviso4954 Před 6 měsíci +1

      @CountryLivingExperience hi and thanks for answering. I do have a 6 slot battery rack with buss bar. I was going to attach both positive cables (2 red cables) to the top slot on + buss bar and the two negative leads to the top slot on negative buss bar. Thanks again

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      That type of connection will work.

  • @user-ew9gz1gy6j
    @user-ew9gz1gy6j Před 2 měsíci

    What about the cost of the batteries? Also how many watts output to your house?
    Great video

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      Batteries are always the most expensive part of a system. What do you need to know?
      Watts output to my house? For the inverters? The inverters are 6000w each to 12000w if needed.

  • @chuckklapp8355
    @chuckklapp8355 Před 24 dny

    You talk about a generator interlock kit in your main breaker. How would I add that? Does the 6000XP work better with a interlock kit vs a transfer switch?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 24 dny

      The interlock is a physical piece that you add to the metal inner cover of your main panel. It costs about $40. A transfer switch can be either manual or automatic. An auto transfer switch will cost you about $1k installed. Either will work well.

  • @shaybee22
    @shaybee22 Před 4 měsíci

    Just got my upgrade from SigSolar with their trade in offer. But they won't be shipping till May due to such high demand so I get a few months to plan the installation :) , Bye bye 6500-EX's and hello 6000XP's !

    • @CountryLivingExperience
      @CountryLivingExperience  Před 4 měsíci +1

      Great. How were the 6500's working? My last batch before these were working perfectly.

    • @shaybee22
      @shaybee22 Před 4 měsíci

      @@CountryLivingExperience Still working perfectly without a hitch and that is with the original firmware, I was about to upgrade the firmware but I've been lazy then I got the inverter upgrade offer from SS so I guess now I'm not going to bother anymore LOL

    • @daddio7249
      @daddio7249 Před 3 měsíci

      @@CountryLivingExperienceI have two I got in August in my solar kit but only got functional last week(I work slow). They power my home just fine, just lots of light flickering and one UPS was clicking so much I had to unplug it. I will be getting the replacement 6000XPs. I got a digital torque screwdriver, PV breakers need more torque then you might think. Also I doubt you are getting the pv input wires tight enough with that tiny screwdriver.

  • @beebop9808
    @beebop9808 Před 6 měsíci

    Going to be ordering a couple of those panels after the first. They have a curious statement about the PV rating that says 8kw but there's a 10kw maximum. No idea what they mean by that and find nothing in the specs about it. Only the minimum and maximum voltages and a warning to check panels for cold temp output.
    Guess they can handle the watt fairies flying by and dumping a little dust on your panels? hahaha

    • @doomsday2002
      @doomsday2002 Před 6 měsíci +1

      I hope someone clarifies it too. The mppts can handle 4000w each so 8000w total and I guess the 10000w max pv input is to allow for over paneling for cloudy/winter days. That way the extra panels can help to make it to the 8000w max input. I guess in the summer at 10000w at max power it will clip it down to 8000w

    • @beebop9808
      @beebop9808 Před 6 měsíci

      Could be yeah. Curious they throw out numbers like that and leave you to guess what it's for.
      But if I get 8kw total I'm sitting phat. My usage isn't very heavy @ about 20kwh/day. Storage is big on my list of things to do. Think 100kwh would be just peachy.
      Find one of these new Ford Lightening's that somebody crashed into a tree, drag it around back and plug it in. Good to go. hahaha

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      I know. That is a strange statement and I was very unsure of it as well. I hope I can get some answers about that. Until then, 8k it is.

  • @joeblocker9248
    @joeblocker9248 Před 6 měsíci

    It would be great if signiture solar would make these hybrid.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      They are hybrid in the sense that they can utilize AC power in and combine a charger with mppt's. Do you want it do be able to sell back to the grid in a grid-tie configuration?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      I believe the EG4 18k supports selling back to the grid.

  • @wili77745
    @wili77745 Před 6 měsíci

    Please comment on the battery settings. Why did you have to use lead acid? Thnx

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      I thought I mentioned that.
      I don't have the correct firmware on my EG4-ll battery so the comms will not work. The inverters will not read any LiFePo4 battery without comms. So you can temporarily set it to Lead Acid and enter in the correct Ah of your entire battery bank and the inverter will charge based on those parameters.

  • @kairasa3536
    @kairasa3536 Před měsícem

    Doesn't this inverter output 50 amps? If so, why is the AC output breaker 40amps? With 6awg, a 50amp CB would be more to spec, or am I missing something? Thanks for any info

  • @nowonehere
    @nowonehere Před 6 měsíci

    How do these compare to the Victron MultiPlus-II 2X 120v. 3000VA? I want to install it in a 50Amp RV for Boondocking. I have 4 LiTime 24v 200AH running in parallel. I will get 2 more in the future. This system looks a lot cleaner and easy to install.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      The biggest difference is they are split phase and an all-in-one unit. You really can't compare them to the victron as they are two different types of systems. These 6000xp's are 48v however. You will need to configure for that.

  • @sh839c
    @sh839c Před 2 měsíci

    What advantage does the xp have over properly running ex models?.

  • @thedabbler2753
    @thedabbler2753 Před 6 měsíci

    Are the battery cables from each inverter going all the way back to the battery cabinet or to bus bars with one beefy cable to the cabinet? I didn't see.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      Yes, that’s correct. The battery cables from each inverter goes back to that common bus bar. Then the big battery cables go to the cabinet.

  • @ravzir
    @ravzir Před 2 měsíci

    Question about the AC side: why are there 4 wires? Where I live, all AC wires have 3 parts: Live, Neutral and Ground. Why do you have two live?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      240 volt split phase power. Used for large loads like clothes dryer, water pump, stove, etc.

  • @KoiAquaponics
    @KoiAquaponics Před 5 měsíci

    Do all the batteries need to be parallel and connect to the master unit or can each bank be hooked up to individual inverters?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      They all need to be connected yo a common buss bar. That buss bar then needs to be connected to each inverter.

  • @iowac
    @iowac Před 4 měsíci

    So you leaving your main inverter as ground neutral bonded/controlled did you unbind in the breaker box? Im new and trying to get visual info on how it looks. Thanks

    • @CountryLivingExperience
      @CountryLivingExperience  Před 4 měsíci

      As an off-grid system, I did not change anything internally on the inverters. My sub-panel has grounds and neutrals separate. My main panel has grounds and neutrals bonded.

  • @kevinmerriweather3680
    @kevinmerriweather3680 Před 5 měsíci

    Can one run a small shop with lights, outlets and power tools?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      Yet, but.....Depends on the tools and how many are running at once. Depends on many factors. They have plenty of power for all kinds of jobs and tools.

  • @AlexanderBell1847
    @AlexanderBell1847 Před 5 měsíci

    Nice review, just curious why you went with two of these as opposed to one 18KPV

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci +1

      Thank you. I like to have a little redundancy with multiple smaller units. If one goes bad, I can still run most critical systems off of 1 unit. Or if I want to expand, I can add 1 more unit for much less than an 18k.

    • @AlexanderBell1847
      @AlexanderBell1847 Před 5 měsíci +1

      Very good point, thank you!

  • @samfish6938
    @samfish6938 Před měsícem

    put better dc switch in underload i have seen your breaker go on fire

  • @mr_DIY
    @mr_DIY Před 5 měsíci

    7:50 or just use j-hook bolts ;)

  • @malcolmkegel3905
    @malcolmkegel3905 Před 6 měsíci

    Hi thanks again for the great content, what are your thoughts on grounding for off grid. I don’t want to create a ground loop in my system I currently have my main panel grounded from a rod and feeding the inverters and sub panel has separate ground and neutral bars. Setting 26 allows to enable or disable neutral ground bond with out an ac source should it be enabled or disabled? Thanks in advanced

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      I am certainly no electrician so my advice should be cross referenced with one. You should have one grounding electrode on the house. All sub-panels should have grounds and neutrals separate. Only ground neutral bond should be in the main panel. There should be equipment grounding conductors that run from each piece of equipment to a ground bar in the sub-panel and then ultimately back to the main panel. I believe the g-n internal bond comes disconnected. I ran mine strait out of the box as configured by the manufacturer. You will have to check with Sig Solar for a more indepth answer on this as my system architecture may be different from yours. Braden from EG4 did a video on this topic on the EG4 CZcams channel if you want to go check that out.

    • @malcolmkegel3905
      @malcolmkegel3905 Před 6 měsíci

      Thanks for the prompt reply. I spoke with signature solar earlier and explained my system layout to them. I have two 6000 xps in parallel feeding a main panel off grid grounded by an earth rod and have separated the ground and neutrals for the main and my sub panel. Setting #26 comes enabled as default and signature solar said this was fine the way I have it configured but they recommended joining my ground and neutral bars at the main panel and to then disable setting #26. I hope this helps someone else wondering the same. I love your content thanks for all the great info.

  • @brinncrowdus9951
    @brinncrowdus9951 Před 4 měsíci

    So I am looking at this inverter and I am a little confused on the PV voltage ranges, especially the minimum MPPT startup voltage. You stated 140 volts as did a Signature Solar video that was very comprehensive. However, 140 volts is not mentioned in the spec sheet from Signature Solar. The spec sheet states in the PV Input Data section a Unit Startup of 100VDC (+/-) 10 VDC, DC Input Voltage Range of 100-480 VDC and an Operating VDC Range of 120-385 VDC. I watched a video by Will Prowse and he stated a 120VDC minimum to start the MPPT charging. Seems this value is very important in determining your minimum string size and the spec sheet is not matching any of the videos. Can you please confirm where you got 140 VDC as one you can search the Spec Sheet and only find 140 in two places and that is 140 A in the Battery Discharge Sections and 140 degrees for max storage temp.

  • @fasnuf
    @fasnuf Před 2 měsíci

    Are you still happy with the 6000XP over the 6500Ex for offgrid use? I got the quote to upgrade and need to decide. I'm not having issues except light flickering on some lights but like the idea of 120/240 on each inverter in case one of them goes down I can still power 240 loads.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      Yes, it is working perfectly well. I had a few issues with my 6500's until I got the correct firmware update. When I switched them for the 600's they were working perfect as well.

  • @rmdarragh4
    @rmdarragh4 Před měsícem

    Question…Do you need to have the batteries into each inverter? What would I use to do that. I am just getting started really. I do have one bank of 4 Lipo EG4 batteries. Thanks!

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem

      In my opinion, yes. You will charge them way more quickly with both inverters being connected to a common buss bar charging the whole bank.

  • @dlpeters0n
    @dlpeters0n Před 4 měsíci

    You mention it requiring two batteries. Is this because of the two units? Seems strange, not sure how that is required. It'd certainly be nice to have 2+ batteries just for the type of load a 12k system would typically have, but as a requirement to function?

  • @spotterinc.engineering5207
    @spotterinc.engineering5207 Před 4 měsíci

    I noticed you have PV connected in reverse to the inverters based on the PV wire colors (red + black -). Am I correct? The inverter was labeled 1+ 1 - and 2+ 2 - from left to right but the PV wires look like they are connected black (-) red (+) from left to right?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 4 měsíci

      Correct. That is because I reversed the wire colors originally when I ran them through the conduit.

  • @intDavid
    @intDavid Před 6 měsíci

    Just curious - it appears you have the red PV wire going to PV- and the black going to PV+. I presume the cables are simply the wrong color?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      The colors were originally switched when the panels and pv wire were originally installed.

  • @benfaubion
    @benfaubion Před 5 měsíci

    I have a newbie question for you about setting up the 6000XP. I'm pretty sure I'd like to set it up in my home, which is grid connected, and I have no need to send electricity back to the grid since the compensation for net metering is so low for where we live. How exactly does this unit physically setup in a way in which it is always connected to the grid, along with battery and solar? In my case, I have one 40 amp breaker that is unused in my sub-panel (there was an old wine cooler that used it and I took that unit out), but what's coming from my 40 amp is just the hot, neutral, ground. Where exactly does the L1 and L2 connect to in this scenario? And what about the difference between the load and grid breakers on this unit? I'm planning on hiring an electrician, but I'm just curious.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      Since I can't physically see your home, I can only give some basic thoughts. Will Prowse set his up with the AC-IN connected. For me personally, I didn't choose to do connect the AC-IN and have not set up a system like that. Make sure your electrician knows DC power. Many do not.

  • @irfanwaseh
    @irfanwaseh Před 3 měsíci

    Can I use it with out batteries only get back up from grid
    Thanks

  • @EbanQHanna
    @EbanQHanna Před měsícem

    Can these new units be installed outdoors?

  • @ousmanediarra6365
    @ousmanediarra6365 Před 2 měsíci

    Can this inverter power the house directly from PV without batteries back up during day time ?

  • @Barc7580
    @Barc7580 Před 6 měsíci

    Wanted to ask what size breaker do you have in your main panel interlock going to your 6000xp’s
    I understand from your video and several others that a 40 amp breaker from each 6000xp should be used in the combiner panel.
    I have a 200 amp service in my main and plan on starting with 2 6000xp’s but want to use the proper breaker and wire between sub panel and main panel. Also trying to think ahead with getting heavier wire between panels for future growth to a 3rd 6000xp so all I’d need to do is change the interlock breaker.
    Thank you.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci +1

      I have a 70 amp breaker at my main panel with the interlock kit. The 70 amp is appropriate for my 4 awg wire.

    • @Barc7580
      @Barc7580 Před 6 měsíci +1

      @@CountryLivingExperience Thank you

  • @colormaker5070
    @colormaker5070 Před měsícem

    I just started working on connecting my 6000xp and trying to follow your process. I noticed your pv connection is Negative on 1 and positive on 2. My inverter shows positive on #1 did the design change?

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem +1

      Nothing changed. Connect it how the manual shows.
      The colors of my wires are reversed. That happened during my original setup a few years back. The polarity of my wires is correct though.

  • @joemccloskey4402
    @joemccloskey4402 Před 5 měsíci

    Shouldn't the breakers be 30 amp and not 40 amp

  • @mylesoffgrid
    @mylesoffgrid Před 4 měsíci

    Have you had good reliability with these? Looking to install in a remote camp with no internet!

  • @jkohutiak
    @jkohutiak Před 2 měsíci

    my EG4 6000xp refuses to put out power when i have it connected like yours are?

  • @bobcole3852
    @bobcole3852 Před 5 měsíci

    I saw someone use a 50 amp breaker ILO the 40 to power subpanel. Think he used #6 wire. What's your thoughts on that since you've had your setup for a while? Manual says 8 gauge which is good for 40 amps.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      You can upsize it a bit. I think that 6 gauge may be the limit though. That said, following the manual is always best.

  • @KoiAquaponics
    @KoiAquaponics Před 5 měsíci

    What's the max dc charging voltage the system allows? I have 17s batteries lifepo4 and I'm hoping it will be able to charge it...

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      450 volts at 20 amps. You need to scale your system components accordingly. Each inverter can only handle 16 100ah batteries by the way.

  • @Nat_Sarim
    @Nat_Sarim Před 6 měsíci

    So will this not operate on one battery? I'd like to use this for just our washroom alone due to it's 2-phase capability, but I didn't think I'd need more than one battery for just the washer/dryer and a light or two, a couple times a week.
    Appreciate your thorough coverage brother.👍

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      You're welcome. Manufacturer recommends two batteries or a total of 200ah capacity.

    • @Nat_Sarim
      @Nat_Sarim Před 6 měsíci

      @@CountryLivingExperienceVery good. I appreciate the quick reply, thanks so much.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      @@Nat_Sarim You're welcome

  • @user-kl4vd4gg3u
    @user-kl4vd4gg3u Před měsícem

    Not meaning to be picking but just for some clarification, it looks like you have the negative from your PV array going in to the positive terminal on the mppt and the positive going in to the negative?

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem

      You’re correct. The wires are reversed in color from my original install but the polarity is correct.

    • @user-kl4vd4gg3u
      @user-kl4vd4gg3u Před měsícem +1

      @@CountryLivingExperience ahhhhhh ok cool, it makes sense now, that would confuse the heck out of me lol

  • @briancook6158
    @briancook6158 Před 5 měsíci

    Can you run a heat pump with 6kw?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci

      What type of heat pump? I have mini-splits which are very efficient and run off a low amperage. They will run with just one 6kw.

  • @carlosreyes6448
    @carlosreyes6448 Před 4 měsíci

    So what if it over loads? Would grid take over? And would it return to inverter mode?

  • @GregMiller-zo5ug
    @GregMiller-zo5ug Před 4 měsíci

    Is the eg4 chargeverter still needed with this newer inverter? Or can a 6.5k pl generator?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 4 měsíci

      I still use it. Same concept applies as to it's purpose. You would still need a larger generator if directly connected to the inverters.

  • @sm6551
    @sm6551 Před 3 měsíci

    I just bought a EG4 600XP and had my electrician wire it to my Generac Transfer switch with a lite load. My electrician was not comfortable hooking the inverter to the batteries so I am wondering if there is an online service that I could pay to help me do that? There are not many solar consultants out on the Oregon coast where I live.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 3 měsíci

      I make videos for the DIY individual. It is not that difficult and if you follow my vids, I think you can do it.

  • @user-zd1gz1ov5w
    @user-zd1gz1ov5w Před 6 měsíci

    Do these use grid power when the sun is out like the 6500 ex?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      It depends on the setting you have. I usually have mine use Solar, Battery, Utility in that order.

  • @Radioactive_Texan
    @Radioactive_Texan Před měsícem

    Great video. I have 1 question. On the second Inverter, is setting 21 set to P1 also, or P2? If both inverters are set to P1, does that not mean single phase on both and I would not get 240?

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem

      As far as I am aware, they are paralleled already when set to the 1PH type. Then all inverters need to be set to P1 phase.
      Mine work fine like this and power my 240v loads.

    • @Radioactive_Texan
      @Radioactive_Texan Před měsícem

      @@CountryLivingExperience Thanks for the quick reply. We got two of the 6000xp's, one already running, 2nd to be hooked up. We are thinking about an additional 30KWH battery rack. That should give us enough power to go for a couple of rainy days.
      I wonder what the P2 setting is for.

    • @CountryLivingExperience
      @CountryLivingExperience  Před měsícem +1

      Glad you are expanding your system. Should be great for a few rainy days for sure.
      Check out Sig Solar's video on commissioning the 6000xp's. Kelly did a great job explaining the setup about 2/3 of the way through the video. czcams.com/video/O8eVxRVwlnw/video.htmlsi=2c4fKdNGKP8PhPn0

  • @comarshlunan8592
    @comarshlunan8592 Před 6 měsíci

    What happened when the batteries are fully charged? Does it automatically stop charging? Or is that something you have to set up?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      All inverters do that. Once they are full, the voltage is sensed and it stops charging.

  • @kencotton4645
    @kencotton4645 Před 11 dny

    Can you hardwire a network cable to your existing home network rather than using the WiFi dongle?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 10 dny +1

      Yes, there is but I am not sure how to do it. I know there is a process but you have to call EG4 and they will walk you through it.

    • @kencotton4645
      @kencotton4645 Před 10 dny

      @@CountryLivingExperience Thanks for the info. I thought there might be when I saw all those network ports on the unit. If you can hardwire into your network, it just seems like a more reliable and faster connection than WiFi.

  • @ihsanhanif3343
    @ihsanhanif3343 Před 6 měsíci

    Is this inverter suitable for single phase 220volt?

  • @alvinaqui9139
    @alvinaqui9139 Před 3 měsíci

    Why do they require two batteries each?

  • @wildcorn12790
    @wildcorn12790 Před 2 měsíci

    How are these 6000xp units working out so far? Are you getting any light flickering at all or is it steady (assuming you're using LEDs). I want to get these so bad, but it's a large chunk of change to drop on them! Trying to sell my 2 TP6048 units first!

    • @CountryLivingExperience
      @CountryLivingExperience  Před 2 měsíci

      They are flawless so far. I get flickering with grid power on my lower quality led bulbs. I don’t notice a difference in flicker with the inverters.

  • @sia3540
    @sia3540 Před 5 měsíci

    Can it be changed with 120 volts only?

  • @frankbohaczyk5968
    @frankbohaczyk5968 Před 27 dny

    How much battery storage do you have and approximately the what do you run off your system? I just ordered an off grid kit with the same inverters. I know I’ll need at least 2 more batteries. Kit came with 4 life pros

    • @CountryLivingExperience
      @CountryLivingExperience  Před 27 dny

      I have +/-46kw of storage. 10 EG4-LL 48v batteries. I run all modern appliances. I have 3 mini-splits. I do have a propane stove however. Well pump is on a separate system.

    • @frankbohaczyk5968
      @frankbohaczyk5968 Před 26 dny

      Do you feel like you have enough to comfortably not worry about power? I’m going to have to do the mini splits as well and they are my biggest concern of draw.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 26 dny

      @@frankbohaczyk5968 Not yet. I am slowly building my system as money allows. I added more panels and a few more batteries this past year. I will continue to do that. I would say I have about 75% of what I would need to "not worry".
      My mini-splits can draw about 1kw at the hottest part of the day but do an amazing job compared to a window unit or a central forced air system. They are the most efficient way to cool a home.

  • @zachreyhelmberger894
    @zachreyhelmberger894 Před 6 měsíci

    Please help me. I spent ten hours today ripping out an old solar power system (24v lead acid) and installing a new one(six lifepower4's and an EG4 6000XP). But the inverter will not produce power. I gotta get this new solar power system running tomorrow or I hafta rip it out and re-install the old!!!

    • @CountryLivingExperience
      @CountryLivingExperience  Před 6 měsíci

      Since I cannot physically see what you did, I cannot give you advice on what to fix. I need much more information

  • @lindaferguson593
    @lindaferguson593 Před 5 měsíci

    I have 2 of the eg4 6500ex 48v. Can I hookup one of these new 6000xp 48v to my existing 6500ex's? Is it doable? Thanks.

    • @CountryLivingExperience
      @CountryLivingExperience  Před 5 měsíci +1

      No, that’s not possible as far as I am aware. They won’t communicate with one another.

  • @MrJar1rad
    @MrJar1rad Před 3 měsíci

    Is it worth it to upgrade from 2 6500 to those in your opinion?

    • @CountryLivingExperience
      @CountryLivingExperience  Před 3 měsíci +1

      It is worth it. These have much better features. All the built in breakers save cost and wiring.