What is Joggle? | Why We Bend a Bar While Lapping?

Sdílet
Vložit
  • čas přidán 26. 08. 2024
  • Hello Friends,
    In this video, I will tell you about joggle, What joggle is and why we use it in lapping in bar column or Beam both.
    Hope you will like and learn something from this video.
    Joggle Part 2 - • What is Joggle in Colu...
    Gadget Use For Making Video.
    Laptop- amzn.to/32ITGS7 (Dell 5577)
    Mic- amzn.to/2AcYd3l (Boya BY M1 Microphone)
    Writing Pad- amzn.to/2QnuG1R (Wacom One)
    Personal Gadgets Use Photography
    Camera- amzn.to/2Nc0SCy (Nikon 7200D)
    Lens- amzn.to/2Ai963y (24-70mm)
    Flash- amzn.to/31mcjv2
    Tripod - amzn.to/2Ai9kaU
    Social Media
    Civil Facebook-
    tutorialstips
    Personal Instagram
    / amit_kr_sah
    Civil Website-
    tutorialstipsci...
    Instagram-
    / civiltutorialtips
    Photography Website
    www.jsstudioz.com
    CZcams-
    / tutorialstips
    Thank you
    Please Subscribe my Channel

Komentáře • 150

  • @AmitSahCivil
    @AmitSahCivil  Před 5 lety +2

    Is the first CZcams channel that gives a reply to all comments with days and hours.
    Try your Self, Comment your query and get your answer very Quickly.

    • @syedadil7435
      @syedadil7435 Před 5 lety +1

      Tutorials Tips maximum joggle kitney inch tk provide kr skte h

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      Bar k dia k according 1:6

    • @oms6335
      @oms6335 Před 3 lety

      Sir Agr Joggle na diya ho toh.. Age Koi problem toh nhi hogi

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety

      Nhi, 16,20,25;;k bar h to joggle dena chahiye

    • @AnujKumar-om7nz
      @AnujKumar-om7nz Před 3 lety

      @Zaire Jay see q

  • @bhaskarchandra1
    @bhaskarchandra1 Před 5 lety +4

    Best part of your video is that they always have practical explanation and site images

  • @a9450154247
    @a9450154247 Před 3 lety +2

    Bhai ek personal question h??
    Mera २००gaj ka plot h... Usme piller banwaye the vo ground level tak cast kr k chod diye the... Due to some problem kaam band ho gya. Ab plot me jo b pillar bar the, sab casting height se hi fully bend ho gye h.. Ab pir se kaam start krna h toh piller making k liye kya krna chahiye??
    Suggestion bar k liye chahiye ki unko lapping kr k seedha kkr k cast kre ya cut kr k cuppler lagaye???
    3storey building banani h toh base pillar strong rhe, uske liye kya kya option ho skte h???

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety +1

      No issue aap us Bar ko sidha kar do or lapping pura column top tak lena or 4 bars ko rebaring karke old k sath casting karke karsakte hai.

  • @shaikhmohdfarazahmed2145
    @shaikhmohdfarazahmed2145 Před 2 lety +1

    shukriya sir nice explain. sir cranck bar ke bare me bataiye

  • @johnjohnson5394
    @johnjohnson5394 Před 4 lety +2

    Great videos welled explain

  • @anuragkhati4547
    @anuragkhati4547 Před 5 lety +3

    Great video sir new thing to learn

  • @gurmeetkumar6246
    @gurmeetkumar6246 Před 5 lety +2

    👌👌 thanks for sharing this sir

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Thanks for watching, please share the video if you like

  • @nazimbaluch6020
    @nazimbaluch6020 Před 3 lety +1

    Excellent explanation of joggle - thanks

  • @sonujatain3421
    @sonujatain3421 Před 4 lety +3

    According to is code joggle is allowed if the column bar are not in layout at first floor

  • @user-gc1kz9so1l
    @user-gc1kz9so1l Před 3 lety +1

    अच्छी जानकारी है

  • @VAIBHAVSPAL
    @VAIBHAVSPAL Před 5 lety +2

    Thank you sir

  • @saurabhtyagi1081
    @saurabhtyagi1081 Před 5 lety +2

    Great video SIR

  • @alltypevideo327
    @alltypevideo327 Před 4 lety +2

    What is technical word of joggle?

  • @jaishreeradhe4529
    @jaishreeradhe4529 Před 5 lety +2

    Great Explanation Bro

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Thank you, dear please share the video to your frnds

  • @ashusaxena91
    @ashusaxena91 Před 3 lety

    Nice

  • @ramendole6744
    @ramendole6744 Před 5 lety +1

    Thanku sir
    for this information
    Make more video I am always with you

  • @anuragsahu1437
    @anuragsahu1437 Před 3 lety +2

    Hello. Column main 16 mm ko 16 mm se jodne k liye kitna joggle den ? Ye kese dete hain ? Aur overlap length kya hogi ? Pls reply.

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety +1

      Dia of bar multiple with 50 matlab 16*50= 800mm lapping length

  • @sahilkumar-nz5td
    @sahilkumar-nz5td Před 4 lety +1

    Nice video sir. Bt ye baar ko curve / bend kaise dena hai . Please koi video bnao ya dikhao Baar ko bend/curve krte hue

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      bars ko band karne ke liye iske tool aate hai. matlab pane

  • @er.sanjaykumar1194
    @er.sanjaykumar1194 Před 4 lety +1

    Staggered ya joggle ... good

  • @saurabhmhatre2749
    @saurabhmhatre2749 Před 4 lety +3

    Sir joggle ka bending angle kitna hota hai?

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety +1

      Angle koi fix nahi hota , jo bar use karte hai ussi k according band karte hai

  • @farhinhasen444
    @farhinhasen444 Před 5 lety +1

    Thanku

  • @akhileshhdas
    @akhileshhdas Před 2 lety +1

    Accha sir lapping zone main tmt bars ko kaise jore????..
    Wires ke through aur welding???..
    Answer me please!.

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety +1

      Wire, welding is also good but expensive.

    • @akhileshhdas
      @akhileshhdas Před 2 lety +1

      @@AmitSahCivil thank you sir।
      But I have read that during welding the TMT bars get hot which may effect the ductility of steel!.
      Also the property of welding material is not same as TMT, during huge amount of pressure it may collapse because at the junction of welding,it loose the elasticity property of the TMT..
      I'm little bit confused!..🤔

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety +1

      all are myth, welding process is good, if we loose the elasticity while welding than why welding machine is invented.

  • @GurmeetSingh-in7pw
    @GurmeetSingh-in7pw Před rokem +1

    If we do side by side lapping , does it still transfer load to the below sariya

    • @AmitSahCivil
      @AmitSahCivil  Před rokem

      yes, its transfer if building height not no much or also depend dia of bars

  • @o.g.3396
    @o.g.3396 Před 2 lety +1

    सर🙏 foundation coloum की सरिया एकसमान होनी चाहिए या लंबी, छोटी होनी चाहिए!

  • @inshaqayoom3068
    @inshaqayoom3068 Před 5 lety +5

    Sir i think joggle provided in column is prohibited in engineering is it corct.
    Sir rply zaroor krna

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety +1

      Kar sakte hai aisha koi issue nahi hai

    • @MayJackson-pg6ws
      @MayJackson-pg6ws Před 4 lety

      Who told you so ?

    • @AMIndustrial
      @AMIndustrial Před 4 lety +1

      Insha Qayoom You are correct it is totally prohibited. See full response posted by me. I think people are confused with the paper representation of the lap splice to real situations.
      Any S shape jags in repair will render the bar useless in tension because it will have an extra length in it trying to go straight and it will elongate with visibility cracks in the columns if it goes into a high tension cycle.
      No code even describe this. Video poster need to add code reference to this practice. I know ACI code does not allow bending tension pars in tension region “Specially lap splice region”
      This video need to be deleted due to the risk of misinformation.
      Regards,

  • @proudindian2190
    @proudindian2190 Před 5 lety +1

    Excellent information! Sir is it beneficial to give jogger from inside the stirrups? , I the overlap column steel from.inside area of ring?

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety +1

      You can bind ring as usual after joggle.

  • @AbdulHadi-rg3es
    @AbdulHadi-rg3es Před 3 lety +1

    Sir mera ek site par joggle nhi diya mestari ne isse kuch problem creat hoga kya plz reply

  • @aliqadri4672
    @aliqadri4672 Před 2 lety +1

    Sir joggle may curve kitna dena hay kia bbs hay reply..??

  • @palak6513
    @palak6513 Před 4 lety +1

    Transeverse reinforcement details dijiya please

  • @sanjaytudu4833
    @sanjaytudu4833 Před 4 lety +1

    Joggle me rod lapping karne ke liye wire se binding thik rahega ki welding karna????

  • @monalithakur2477
    @monalithakur2477 Před 3 lety +1

    Sir Sare joggle lekin ek hi jagh par nahi aa sakte. Matlab ki upar neeche karna chahiye. Column me agar 4 bar hai to koi thoda upar joggle hoga koi thoda neeche. Ek hi level par joggle ya lapping nahi de sakte

  • @makistar4855
    @makistar4855 Před 2 lety +1

    Sir mere total ghar k construction m 20 column h aur bs 2 column m h 18 feet ka distance baki h column m. 10 ft, 12 feet tk h. Aur column 9×14 ke h. Aur steel bar 6 h. 16 mm ke 4 aur 12 mm ke 2.tho sir m G+2 bna skta hu. Plz guide sir🙏🙏🙏

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety

      Bilkul Kar sakte hai, but kuch baato ka dyan dena hoga, jaise same ground floor ki planning ko first floor par lena hoga means walls k upper walls, second things concrete ki quality steel ka lapping length and lapping zone par v dyan dena hoga, main thing without engineering consultancy kaam mat suru mat kariyega.

    • @makistar4855
      @makistar4855 Před 2 lety

      @@AmitSahCivil mtlb G+2 bna skta hu is structure m. Tekedar tho bolra isme tum g+2 aram se bna skte ho. Plz guide me sir

  • @anuragkhati4547
    @anuragkhati4547 Před 2 lety +1

    Sir isme agr site par steel nikalana ho to kaise work out karein length steel li

  • @SanjayKumar-ew4nm
    @SanjayKumar-ew4nm Před 5 lety +2

    Joggle kitna provide krte hain?
    I mean as per IS code or specifications,how we decide how much we sud provide joggle?
    Thanks

  • @nooraincivilengineer
    @nooraincivilengineer Před 2 lety +1

    Kitna digree band hota hai jogal as for steel mm

  • @MayJackson-pg6ws
    @MayJackson-pg6ws Před 4 lety +1

    Sir joggle Kiya huva bar & uska neeche ka baar ke beech me jyada se jyada kitna spacing rehni chahiye?

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety +1

      Lapping length tk

    • @MayJackson-pg6ws
      @MayJackson-pg6ws Před 4 lety

      @@AmitSahCivil matlab lapping bar uska niche ka baar done join karke ke bandhna hota hai kya ?? Dono bars ke beech me space nahi chodni chahiye kya ?

  • @makistar4855
    @makistar4855 Před 2 lety +1

    Sir ek steel bar ki length 39.6 feet hoti hai. Tho kyu hum jitne height rkni ghar ki utni steel bar nhi rkte aur sariya kat dete hai hmare tekedar ne bi aisa hi kiya. Aur fir lapping krege bolra. Tho isse tho steel ki strength tho ktm hogyi na. Plz btaye sir🙏🙏

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety

      strength kam nahi hogi agar lapping location or lapping length sahi hogi to, or ek sath 12 m ya 40ft ki height aap de sakte hai koi dikkat nahi hai, upar aap usko manage kaise karoge, steel column bahut bari ho jayega, or bend bhi ho sakta hai, usko uthane k liye crain lana padega, accident bhi ho sakta hai, isliye wo aisha nahi karte hai?

    • @makistar4855
      @makistar4855 Před 2 lety

      @@AmitSahCivil बहुत बहुत धन्यवाद sir आप जैसे गुरु को तो ये ठेकेदार लोग हम जैसे लोगो का bewkoof nhi बना सकते. और हम अच्छे से काम करा सकते है. Sir आप से whats app मे बात nhi हो सकती 🙏🙏🙏🙏

  • @mohammadfiroz7596
    @mohammadfiroz7596 Před 5 lety +4

    Joggle ko kitne digree me curv kar sakte hai?

  • @sgpfamilysgpfamily844
    @sgpfamilysgpfamily844 Před 2 lety +1

    Sir which dia should be provide joggle.

  • @SURAJSINGH-gu9dm
    @SURAJSINGH-gu9dm Před 4 lety +1

    Nic

  • @makistar4855
    @makistar4855 Před 2 lety +1

    Sir my house is constructing in dehradun (Uttarakhand) in area of 2200 square feet.our arcitech made the map but not by structure design. So our contractor structure engineer has given 20 columns. Of size 9×14.In 1 column he is using 6 steel bars, 4 steel bar of 16 mm and 2 steel bars of 12 mm.footing is taperzoid with height 1.5 feet and he is giving 9×18 plinth beam size. in outer he is using 8 steel bars 4 steel bars of 16 mm and 4 steel bars of 12 mm. But in only 2 of column there is span of 18 feet. And he is saying that without any tension you can make G+2 in this structure. Do I have to worry aur tension free. Plz guide me sir🙏🙏🙏🙏🙏

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety

      your structure is good for G+1 floor but but now I'm seeing this comment your want to G+2 but here I'm confused what you want to construct first floor or first or second floor?

    • @makistar4855
      @makistar4855 Před 2 lety

      @@AmitSahCivil for g+2 is it good structure

  • @Bubai-315
    @Bubai-315 Před 4 lety +1

    Can lapping be given under plinth beam?

  • @davinderg918
    @davinderg918 Před 4 lety +1

    Sir joggel ki length/bend kitni provide karni hai ye kesey patta chalta hai

  • @yashgupta6826
    @yashgupta6826 Před 5 lety +1

    Thank You Sir....... For Information.....

  • @Khatushyam333
    @Khatushyam333 Před 3 lety

    Sir, Hamare column me joggal ek hi jagah kr diya hai, uper niche ( ulternate) nahi kiya hai, but abhi column ko bhara nahi hai. Kuch tarika ho sakta hai kya ?
    Jisse joggal ek hi jagah hone se column pr load padne pr crack na ho jaye ?
    Sir Please reply 🙏

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety

      aapka structure kitna upper jayega or bars ko upper niche mix karne k liye cutting k time par dyan dena tha ya fir abhi 50% bars ko 1 length mai cut kar do upper niche ho jayega

  • @KamilQuraishi
    @KamilQuraishi Před 5 lety +1

    Sir aap 3D Max k tutorial nhi upload krte beginner k liye..

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      TiTime ka issue hai bhai, uske liye thoda time chahiye

    • @KamilQuraishi
      @KamilQuraishi Před 5 lety

      @@AmitSahCivil theek h Bhai mjhe intizaar rhega tutorial ka

  • @manmohannegi3062
    @manmohannegi3062 Před 3 lety

    lapping , couplers dono me se kaunsa sahi he krna earthquake zone m

  • @brig-iccivil8850
    @brig-iccivil8850 Před 4 lety

    bar we r providing inside might be it will not effect to over covering

  • @sahiransari3288
    @sahiransari3288 Před 5 lety +1

    How much provie joggle length.

  • @sadikkilledar8484
    @sadikkilledar8484 Před 2 lety +1

    Jogle ki length kitne hone chahiye

    • @AmitSahCivil
      @AmitSahCivil  Před 2 lety

      uski length uske dia k according or lapping length k according rakhne hai,

  • @chiragghughal6869
    @chiragghughal6869 Před 5 lety +2

    Sir joggle is important to transfer load not for only ring alignment

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Yes, both are important

    • @aksinha9275
      @aksinha9275 Před 4 lety +1

      Both important nhi... Load transfer k liye diya jata hai.. Kya yaar aapne to iska meaning he change kr diya... Sach me aapne civil engineering kiya hua hai?
      Had hai yaar....

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      Common si baat hai jab lap hoga to load transfer hoga ismai, na samjhne wali koun si baat hai , kya maine bola ki load transfer nahi hoga ye dene se

  • @kaushalparmar2774
    @kaushalparmar2774 Před 2 lety +1

    Joggle formula???

  • @sohailkazi7028
    @sohailkazi7028 Před 3 lety +1

    What is the joggle angle?

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety

      According to bar dia

    • @sohailkazi7028
      @sohailkazi7028 Před 3 lety +1

      Sir can you please give example.
      For eg in how much in H:V ratio

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety

      It's not according to ratio it's depend upon dia or bar, if your bar dia is 20 than you have bend it 20-25mm horizontal than bend your bar to vertical

  • @pradeepbharti6643
    @pradeepbharti6643 Před 4 lety +1

    Joggle kaise lete hai bend length kaise lete hai 32* reinforcement joggle length kaise lete hai

  • @tusharkohli9555
    @tusharkohli9555 Před 4 lety +1

    Sir Agar Lenter Casting ke baad galti se column ki half bars (20mm)ki length thik hai aprx 1000 mm but half reforcing bars ki length short aprox 550 mm reh jaye to kya kare kindly suggest the solution

  • @mohdaziz3625
    @mohdaziz3625 Před 4 lety +1

    12 mm ke bar Ku b karna hai sir

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      Jaruri nhi hai utna, but kar sako to acha hai

    • @cbc6320
      @cbc6320 Před 3 lety

      @@AmitSahCivil sir aur 16 mm me joggle nhi dene se chalega kya???

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety

      Dena chahiye, but building type or depends karegw

    • @cbc6320
      @cbc6320 Před 3 lety +1

      @@AmitSahCivil apna contractor juggling nhi dia h .. Can we rectify it??? Pilar ka Majbuti pe kya farak padta h juggling nhi dene se??

    • @AmitSahCivil
      @AmitSahCivil  Před 3 lety

      Fark padega, but depending building height, building ki height jyda hai to joggle dena chahiye

  • @vinit7898
    @vinit7898 Před 3 lety +1

    P

  • @anuragkhati4547
    @anuragkhati4547 Před 5 lety +1

    Sir pls meri.job lagwa do kahi site p

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Wait when any vacancy is open i will tell you

  • @malkeetsidhu790
    @malkeetsidhu790 Před 5 lety +1

    Do you have any WhatsApp group ?

  • @aksinha9275
    @aksinha9275 Před 4 lety +2

    Sir apne knowledge ko tk kr lo...
    Iska main reason hai proper axial load transfer krna from slab to footing...
    Aapne toh meaning he badal diya... .. Aise galat information share na kiya kro

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      To maine kya bola ki load transfer nahi hoga kya??

    • @aksinha9275
      @aksinha9275 Před 4 lety

      Aapne sirf cover k bare me bola sirf...
      Cover ko toh eliminate kr sakte hai... .. Oo bara issue nhi hai... Iska matlab ye nhi ki tk ho gya... Iske piche ka Main reason kya hai o btana chahiye aapko....

    • @AmitSahCivil
      @AmitSahCivil  Před 4 lety

      Chalo mai ek baar video dekhunga kafi purana video hai,
      Chalo acha hai aapne dyan diya or mujhe iske baare mai bataya.
      But aap bol rahe hai galt information mat do mai galt information to di nahi, kuch or information miss ho gai bas

  • @Ranjanpatra143
    @Ranjanpatra143 Před 5 lety +1

    I think beach mein jo steel h usko joggle nehi marna chahie

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety +2

      Beeck mai steel kaha hota hai sab steel to outer mai hi hoti hai, or sabhi joggle mar sakte hai but sab ko ek hi location par nahi mar sakte

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Beeck mai steel kaha hota hai sab steel to outer mai hi hoti hai, or sabhi joggle mar sakte hai but sab ko ek hi location par nahi mar sakte

  • @syedadil7435
    @syedadil7435 Před 5 lety +1

    Agr koi column out ho gya 1” tu hm kitney inch tk joggle le skte h maximum

    • @AmitSahCivil
      @AmitSahCivil  Před 5 lety

      Joggle v 1" ka hi denge, maximum depend karega ki column k kitne bar out huye hai, 20-30 mm tak ka to de sakte wo v 1-2 bar sabhi k liyecolumn problem mai aa jayega, or maximum is par v depend karega ki column par load kya or kitna aa rha hai

    • @AkashSharma-hv4kl
      @AkashSharma-hv4kl Před 4 lety

      Aap joggle sirf dia of steel k equal hi de skte h mean 20 dia steel toh 20 mm joggle as i knw