    DER EE DE-5000, Silicon Chip ESR Meter MkII, MESR-100, MK-328, ESR meter comparison, I compare a capacitor ESR reading across all four meters, to see how accurate they are relative to each other.
    DER DE-5000 LCR Meter: defs.link/?u=12d498
    MK-328 Tester: defs.link/?u=739ee7
    MESR-100 ESR Meter: defs.link/?u=009419
    Please help to support me so I can continue making more repair videos:
    PayPal Donations: payments_to@thedefpom.com
    Patreon: / thedefpom #ifixstuff #thedefpom #electronicsrepair
    TheDefpom Merchandise: teespring.com/stores/thedefpom
    ==========================================
    Some Of My Electronics Tools (video and purchase links)
    ==========================================
    Boonton
    ------
    4220.
    8210: defs.link/?u=e1eddc
    Fluke
    ------
    8842A:
    45: defs.link/?u=eac51d
    343A: defs.link/?u=13c93d
    5200A: defs.link/?u=a43c99
    540B: defs.link/?u=0c6bd9
    893A.
    A90.
    HP/Agilent/Keysight
    ------
    4261A: defs.link/?u=07ed95
    5005A.
    5342A 18GHz: defs.link/?u=5f7513
    6181B: defs.link/?u=b12aef
    8012B: defs.link/?u=ca5764
    8648B: defs.link/?u=da52a3
    8901B: defs.link/?u=535835
    DSOX1102G: defs.link/?u=a68d39 defs.link/?u=12d498
    E3646A: defs.link/?u=128f4a
    Marconi
    ------
    2022D.
    2955.
    TF2103: defs.link/?u=61baaa
    Rohde & Schwarz
    ------
    SMY: defs.link/?u=93514b
    CMU200: defs.link/?u=8ccd72
    Polarad SPN: defs.link/?u=2ead82
    Siglent
    ------
    SDM3065X: defs.link/?u=1ed0fe defs.link/?u=12d498
    SDS2102 (hacked to 340MHz): defs.link/?u=1ed0fe defs.link/?u=12d498
    SPL-1008.
    SDP1168X: defs.link/?u=1ed0fe defs.link/?u=12d498
    SDL1020X-E: defs.link/?u=a0eccb
    Other Equipment
    ------
    KSGER T12 Soldering Iron: defs.link/?u=620ace defs.link/?u=5c112e
    Quick 861DW: defs.link/?u=138c0f defs.link/?u=a3fc81
    S-993A: defs.link/?u=079677 defs.link/?u=e855a0
    EEVBlog BM235: defs.link/?u=12d498
    YR1030 Battery ESR: defs.link/?u=c56527
    Heathkit IT-12 Signal Tracer.
    Racal Dana 1992: defs.link/?u=8eeeba
    Bird 43: defs.link/?u=4b18f7
    Sinadder 3: defs.link/?u=2bf1dd
    Audio Control SA-3050A RTA: defs.link/?u=a04df2
    Korad KA3305D: defs.link/?u=69090a
    PDVS2mini: defs.link/?u=869ba4
    Valhalla 2703: defs.link/?u=06bcfc
    Feeltech FY6800: defs.link/?u=8b98cd defs.link/?u=34d101
    Eakins Microscope: defs.link/?u=b0278b defs.link/?u=262327
    Mustool G600: defs.link/?u=b8bc26 defs.link/?u=33f0aa
    Handheld Equipment
    ------
    Uni-T UT210E: defs.link/?u=391ce3 defs.link/?u=ea4edc
    DER DE-5000: defs.link/?u=0d9160 defs.link/?u=12d498
    MK-328: defs.link/?u=0d9160 defs.link/?u=739ee7
    MESR-100: defs.link/?u=0d9160 defs.link/?u=009419
    ESR Meter: defs.link/?u=0d9160
    HOPI: defs.link/?u=7fab55
    PeakMeter PM6252: defs.link/?u=59ef66
    HS1010: defs.link/?u=10c699
    Thermal Camera: defs.link/?u=280cca defs.link/?u=4a2256
  • Věda a technologie

Komentáře • 70

  • @freemaninprogress1659
    @freemaninprogress1659 Před 7 lety +18

    I've watched 2 different youtube videos comparing the readings on the DER EE against high-end bench equipment - the DER EE is insanely accurate

    • @TheDefpom
      @TheDefpom  Před 7 lety +1

      Freeman in Progress - thanks for the info, good to know.

    • @fredflintstone8048
      @fredflintstone8048 Před 2 lety +2

      The DER EE has probe resistance compensation (4 wire and a bridge) so it will read a lower ESR which is more accurate than meters using plain probes. Having the ability to connect probes together and zero the meter does help.

  • @ZilogBob
    @ZilogBob Před 5 lety +1

    That would be the most laid-back electronics video clip I've ever seen on CZcams. Good to see that my "Silicon Chip" meter stacks up OK against some of the opposition.

  • @jacoblindquist1152
    @jacoblindquist1152 Před 7 lety +11

    Three of the meters need to go trough calibration mode beforehand for first use. I got two of them. One is the MK-328 which in fact is far the easiest meter to use. Don't turn it on before you have the test leads on the subject. Just push the button and it's ready. It's is for the price very precise compared to my HP pro meter.

  • @pds8475
    @pds8475 Před 5 lety +11

    You might already know this by now but capacitance is measured at 120Hz and ESR is measured at 100KHz hence why you were getting strange readings from the DER EE. The MESR probably alternates between the two frequencies but the DER EE does a lot more than ESR tests therefore you have to select the right frequency for the test that you are doing.

    • @ivanradoslovic8229
      @ivanradoslovic8229 Před rokem

      How to know which frequency to choose for testing caps? Is it better to test it on multiple ones?

    • @davidknightaudio934
      @davidknightaudio934 Před rokem

      also series /paralell mode deree is thebest others r junk and will mislead ppl just don't know how to use propper meter like de5000

  • @conwaynoel3715
    @conwaynoel3715 Před 2 lety +1

    I use the MESR 1OO and find it very good. No issues with it.

  • @dennisqwertyuiop
    @dennisqwertyuiop Před 7 lety +5

    I have the DER EE DE-5000 and changed the clips to better ones as seen on TRX bench,, works well

    • @TheDefpom
      @TheDefpom  Před 7 lety

      DENNIS N - I also changed the clips, I did a video on it too.

  • @raindropsrising7662
    @raindropsrising7662 Před rokem

    Thanks for the quick useful demonstration of ESR meters

  • @kellykeys6092
    @kellykeys6092 Před 5 lety

    What if you want to measure a capacitor that falls outside the given ESR table? For example, I have a 400volt 80 Farad capacitor in circuit. How would I test that one to make sure it is good using the MESR-100? Or, can it be done at all using this meter?

  • @tonysfun
    @tonysfun Před 7 lety

    The second tester from the left, I think you can just power it up by the TEST button, but you must have the leads connected first!
    Anyway, thanks for your videos!
    If you have the MLC500 also, can you compare it to the MESR100?
    Do you happen to have a REAL MANUAL for the MESR100?

  • @dmuntz
    @dmuntz Před 2 lety +1

    Good video. Would love to see more tests though. Testing a few good caps at different values would be interesting to show how accurate each meter is.

  • @thecoinmagician
    @thecoinmagician Před 6 lety +8

    The DER EE DE 5000 is by far the best , read the reviews...

  • @Pyridox
    @Pyridox Před 7 lety +2

    I have the MK-328, and for the money that I paid ($28 US on Amazon) I have been happy with it. It can test capacitors, as well as transistors (NPN-PNP-FET), diodes, & thyristors. The case is not the best, but I keep it on the bench. I believe the test frequency is 8 Khz. Amazon also sells a model without a case (model M28), that you could put into your own case.

    • @TheDefpom
      @TheDefpom  Před 7 lety +1

      +Pete Ciallella - yes it seems to work ok, just could use more buttons and a user interface so it feels like a proper tool.

    • @freemaninprogress1659
      @freemaninprogress1659 Před 7 lety

      8 Mhz cannot be right - will be 50 Khz or 100 Khz - crystal could be 8 Mhz

    • @Pyridox
      @Pyridox Před 7 lety

      You are correct, it is 8 Khz. Sorry for the typo, corrected.

    • @freemaninprogress1659
      @freemaninprogress1659 Před 7 lety +1

      The single frequency ones are 100Khz for the more expensive ones, and the really cheap uncased ones are 50Khz
      What you'll usually find is an 8Mhz crystal divided down to 100Khz - which was the original spec of the designer (probably because electrolytic capacitor manufacturers test at 100Khz) - don't know why some of the cheap ones are only 50KHz - but that is better for testing big electrolytic capacitors than 100Khz
      That DER 5000 meter is really good - has a variety of frequency ranges

  • @UpcycleElectronics
    @UpcycleElectronics Před 6 lety +2

    MK-328 is a sub-par clone version of the German OSHW AVR Transistor Tester project that can be found at mikrocontroller dot net /articles/AVR_Transistortester. English and alternate firmware support is available on the EEVBlog forum. The tester is not intended as a replacement for a LCR or ESR meter. It is just a ballpark figure. There is extensive documentation available through the official project forum thread, article, and SVN repo with a mirror of the SVN repo also available through github. The project was developed as an exercise in ultra simple hardware while pushing the limits of the internal hardware of the AVR MCU through a combination of C and Assembly. Basically this is the balls to the wall limits of an ATmega ADC. You can update the firmware or add project options for additional functionality ;)

    • @uK8cvPAq
      @uK8cvPAq Před 6 lety +1

      How is it sub-par? It seems to be good enough.

  • @anthonydacko2856
    @anthonydacko2856 Před rokem

    Good video

  • @freemaninprogress1659
    @freemaninprogress1659 Před 7 lety +5

    Apart from the MK-328 who's frequency no seller lists in the specifications they are or can be set to 100 Khz - which is what capacitor data sheets test them at - i.e. the ideal frequency for smallish capacitors
    The DER EE is clearly the best one as you can select low frequencies - needed for accurately testing large capacity capacitors found in audio amplifiers
    The really cheap testers (usually without a case) use 50 Khz frequency and are inferior
    One you haven't got is a Russian one ESR-Micro v4.0 - shipped direct from Russia via their Russian language web site - but frequently not available - I'm getting one as soon as they have some more in stock - reputed to be best of the best
    In the meantime I'm going to try and find a UK supplier of the DER EE
    PS - that old cap likely needed a 1 hour charging voltage on it to bring it back to life, before discharging it and testing it - even unused but old stock electrolytic caps that have been stored for a few years need re-rejuvenating

  • @SoddingaboutSi
    @SoddingaboutSi Před 7 lety

    I have the second one in too, it works but is crappy case puts me off. Good for fet testing though. The main ESR meter is the HP 4261a and a Racal Bridge.

    • @TheDefpom
      @TheDefpom  Před 7 lety

      Simon Spiers - I was looking to buy a decent hp lcr meter, but the prices put me off, the de-5000 was purchased instead as it does what I need and was a quarter of the cost. Yes the mk-328 works, but isn't the nicest to use, ok if your on a budget and just want something cheap that does the job though.

  • @IliyaOsnovikov
    @IliyaOsnovikov Před 5 lety +2

    Why haven't you plugged the capasitor directly into DE-5000 slots? Or at least you should use TL/21 attachment with alligators instead of TL/22 tweezers.

  • @firstnamelastname7476
    @firstnamelastname7476 Před 6 lety

    yeah some prep is good, but over-preparation into the realm of lifeless/clinical is also pretty awful. thanks for the video .. helped me a lot.

  • @DW7BPB
    @DW7BPB Před rokem

    great comparison..how about their inductance measurement accuracy? do they all agree to some degree?

  • @maurizio700
    @maurizio700 Před rokem

    Thanks for sharing this video but I don't understand why you turned off/on each time the instruments. It was frustrating.

  • @uK8cvPAq
    @uK8cvPAq Před 4 lety +3

    Those Chinese tester things do have a calibration routine, short all three test leads together and press test it'll ask you to run calibration. Also I found the grabber leads and not that great as they have a habit of oxidizing and the wire strands like to snap over time.

  • @irishguy200007
    @irishguy200007 Před rokem

    Which meter is the third one.

  • @jon123423
    @jon123423 Před 7 lety

    is this any good DE-5004 6000 Count DER EE?

    • @TheDefpom
      @TheDefpom  Před 7 lety

      Mods & Tweaks - I don't know, I'm not familiar with the model.

  • @mikes1031
    @mikes1031 Před 6 lety +4

    If I'm not mistaken the DER should have had been set to 120hz to test that Cap, not 1khz plus you raised the Cap temp from holding it. I think that's why the readings differ so much between the DER and the other testers. But not a bad video.

    • @Mtaalas
      @Mtaalas Před 5 lety +2

      Those two aren't enough to explain it. He simply didn't calibrate the instrument so he's measuring the lead capacitance/inductance/resistances as well as the capacitor itself...

  • @clems6989
    @clems6989 Před 2 lety

    It's actually measuring capacitive reactance. So frequency is ctitical. Most of these use a 100khz test signal..Alsobthe one on far right (msr100?) You need to zero the leads out..

  • @PBS-nm1uu
    @PBS-nm1uu Před 6 lety

    what brand is the esr meter ? { the forth one }

    • @TheDefpom
      @TheDefpom  Před 6 lety

      MESR as far as I can tell, it may just be unbranded.

    • @fkm504
      @fkm504 Před 5 lety +1

      jingyan

  • @irishguy200007
    @irishguy200007 Před rokem

    What use are these?

    • @trieck
      @trieck Před rokem

      A capacitor can develop high Equivalent Series Resistance (ESR), which is one indicator that the capacitor is on its way out, or currently kaput and needs to be replaced.

  • @b1nsid383
    @b1nsid383 Před 3 lety +2

    i like these videos but.. only for me is his pronuntiation so hard to understand? obv i'm not native eng

    • @TheDefpom
      @TheDefpom  Před 3 lety

      Yeah my speech isn’t very good, that’s just how I talk.

  • @nspization
    @nspization Před 7 lety

    how to protect DE-5000 from capacitor charge any trick for this ?

    • @Drew-Dastardly
      @Drew-Dastardly Před 7 lety +4

      I usually use a screwdriver as a crowbar to short errant caps. Only a fucking imbecile would use any of these devices on a live or charged circuit.

  • @WV591
    @WV591 Před 6 lety +1

    TU.too bad they don't make the silicon chip kit any more.

    • @kellaudio5849
      @kellaudio5849 Před 6 lety +2

      YES they do, well at least Anatek Instruments does. It's now called the Blue ESR Meter. This is the latest Bob Parker design (approved and sanctioned by Parker) and successor to the famous Dick Smith MKII ESR and Low Ohms Meter. This handy and affordable meter, built 100% in the USA. I love mine and it's the best tool for electrolytic testing.
      anatekinstruments.com/products/fully-assembled-anatek-blue-esr-meter-besr $95.

    • @ZilogBob
      @ZilogBob Před 5 lety

      @@kellaudio5849 Wow, thanks for the plug! Actually Altronics in Australia make a clone of the Dick Smith/Silicon Chip Mk2 meter. It's at www.altronics.com.au/p/k2574-esr-meter-kit/

  • @skeggjoldgunnr3167
    @skeggjoldgunnr3167 Před rokem

    I just opened the box and put the batteries into my new MESR-100 all excited to get a replacement for my useless DER-ee DE-5000. Nothing. It arrived dead. New fresh alkalines. My luck.

    • @TheDefpom
      @TheDefpom  Před rokem

      You certainly are unlucky.

    • @skeggjoldgunnr3167
      @skeggjoldgunnr3167 Před rokem

      @@TheDefpom they never stripped the red + battery terminal wire. Never tried soldering it. The positive terminal seas tinned with a smooth lean blob of solder just waiting for it. I had to solder it. Device had a “QC PASSED” sticker right below the “made in China” sticker. Oh - I understand now!

    • @TheDefpom
      @TheDefpom  Před rokem

      @@skeggjoldgunnr3167 yeah the stickers mean nothing.

  • @brunomahle1618
    @brunomahle1618 Před rokem

    Bob Parker,....Australian for electrickery

  • @PBS-nm1uu
    @PBS-nm1uu Před 6 lety

    fourth sorry for the wrong spelling

  • @skeggjoldgunnr3167
    @skeggjoldgunnr3167 Před rokem

    That der-ee HERp deRP de-5000 winds up tellin' ya "OL" on everything after you've owned it a year or so. That's not useful.

    • @TheDefpom
      @TheDefpom  Před rokem +1

      I’ve had mine for about 6 or 7 years, still working fine for me, maybe you have a bad cable

    • @skeggjoldgunnr3167
      @skeggjoldgunnr3167 Před rokem

      @@TheDefpom more likely I had failed to discharge a cap prior to testing one day. It gave all myriad of readings - conflicting, unreliable. One day I found some of my colophony rosin on the kelvin 4-wire test tweezers. !! - I cleaned that off and - still I couldn’t have it on my bench telling me meaningless values or most likely the usual “OL”. In the garbage with it. I was impressed with its performance at first. I got my mesr-100 working now and I hope to be cautious and more fortunate with it now that I’ve done their assembly work for them (it arrived dead because it’s red battery wire should maybe be soldered on for that QC PASSED sticker to have meaning in China.)

  • @mahirerensan
    @mahirerensan Před 6 lety +1

    25 disliker use DER EE brand

  • @irishguy200007
    @irishguy200007 Před rokem

    Won't a multimeter test a capacitor?

    • @trieck
      @trieck Před rokem

      A multimeter will test capacitance, but it will not test ESR, which is what this is all about.

  • @fins59
    @fins59 Před 5 lety +10

    The idea was good but surely you could have picked an electrolytic that didn't have rusty leads, checked the lighting, made sure that all the meters were working, zeroed them before taking measurements when required, and written down the results.
    Do a rehearsal before making your videos so that you don't waste your viewers time. That could have been a really interesting video but it was so amateurish it was painful.

    • @TheDefpom
      @TheDefpom  Před 5 lety +3

      fins59 - this isn’t television, I am an amateur.

    • @Paul-ib5xv
      @Paul-ib5xv Před 5 lety +2

      Harsh

    • @fazilamzirf8887
      @fazilamzirf8887 Před 5 lety +1

      I do appreciate that Defpom(?) is only an amateur and still appreciate his time to gather these and compare. But I do agree that it takes way too long. The first meter isn't turned on until almost 3 minutes into the video.

    • @battlecoder
      @battlecoder Před 5 lety +4

      @fins59 Is 10 minutes really that long? I enjoyed the pace, and I quite like that the video was not rehearsed. Rehearsing and editing a video takes time, from planning and creating a general script, to doing some test runs for the camera and later editing the result. I don't want to be rude but you are asking him to add at least 1-2 hours more of time and effort into this video that he has generously shared with us all for free.... to save you what? 3 minutes of viewing time?

    • @ctbully
      @ctbully Před 4 lety +3

      If you are such an EXPERT why the hell didntt you do it yourself instead of criticizing someone who actually took his time to do something, you POMPOUS ASS!

  • @billhill839
    @billhill839 Před 5 lety +2

    Can't understand you. Slow down and talk clearer.