Double door fridge Frost Free wiring diagram full detail.

Sdílet
Vložit
  • čas přidán 13. 09. 2024
  • Double door fridge Frost free wiring diagram.
    Hi frends
    Hum ne diagram ke zareye aap ko Double door fridge Frost free ki wiring kaise karte hai btaya hai.
    Agar aap logon ko ye video pasand aai to zaroor comment kare
    Aap Logan ko kis related videos chahiye batay.
    Mere channel. . technical tek. Ko zaror subscribe kare
    Please. Like& share
    Split AC out door wiring diagram
    Full details
    • split AC out door wiri...
    Split AC out door unit wiring diagram
    With multy capacitor & magnetic contactor
    • Split AC out door unit...
    Refrigeration Gas pressure information
    • Refrigeration Gas pres...
    #technicaltek
    #double door fridge wiring diagram

Komentáře • 89

  • @ismaeltechnician3263
    @ismaeltechnician3263 Před 3 lety +10

    wrong connection on timer Sir.....4 is for compressor 2 is for heater

    • @Tech9india
      @Tech9india  Před 3 lety +1

      Sir this is Videocon timer see Videocon timer connection

    • @worlboss2844
      @worlboss2844 Před 2 lety +6

      @@Tech9india your connection is incorrect, just watch the schematic on your timer, NC is compressor , NO is heater

    • @bejaylloydmasong4234
      @bejaylloydmasong4234 Před 2 lety

      Boss ano kulay ng heater

    • @tohidchowdhury732
      @tohidchowdhury732 Před 2 lety

      This one write conection,,,,are you ok

  • @mdridoyhasan4216
    @mdridoyhasan4216 Před 2 lety +1

    সেলিম

  • @samuelrajesh2753
    @samuelrajesh2753 Před 3 lety +1

    Very useful video, nice try

    • @Tech9india
      @Tech9india  Před 3 lety

      Thanks for watching my channel.
      Please subscribe me

  • @kerimyigit5370
    @kerimyigit5370 Před 3 lety +4

    !!!4 - compressor, 2 - heater on defrost timer

    • @Tech9india
      @Tech9india  Před 3 lety

      Hello brother
      Aap Videocon company ka defrost timer ek baar chek kare.
      Ya aap ka WhatsApp ka no deen
      Aap ko detail me video donga
      4 par compressor hai ya heater?

  • @appalanaidu4772
    @appalanaidu4772 Před 3 lety +1

    Clear and easyle tq

  • @mohdshukershuker1204
    @mohdshukershuker1204 Před 2 lety

    Very very good Diagram 👌👌👌

  • @patricks7984
    @patricks7984 Před rokem +3

    Why is the compressor on the NO contact and the heater on the NC contact in the timer?? Something seems backwards. Pretty graphics, info dangerously missing leading.

  • @onlinetvetrac3820
    @onlinetvetrac3820 Před rokem

    Good video

  • @praveendosapati2676
    @praveendosapati2676 Před rokem +3

    👋Hay
    Please do correction ,
    Timer No:04 is the Cooling (Compressor)
    Timer No:02 is the Heating
    (Heater) Thanks

  • @karthi1384
    @karthi1384 Před 5 měsíci

    ரொம்ப நன்றி எளிதில் புரிந்து கொள்ளும் படி இந்த பதிவு உள்ளது

  • @muhammadnaeem4834
    @muhammadnaeem4834 Před rokem

    Very nice

  • @dappareilselectromenagersb2530

    تحياتي الشيمة يبانية

  • @SathishKumar-mz5sn
    @SathishKumar-mz5sn Před 10 měsíci

    4:24 most watched

  • @adilriaz9726
    @adilriaz9726 Před rokem

    Aj main practices karta hun frieddge

  • @hasmukhbutani1131
    @hasmukhbutani1131 Před 3 lety

    Super..sirji

  • @shaguftanaaz8555
    @shaguftanaaz8555 Před 3 lety

    Well done👏👍

  • @mukhadea
    @mukhadea Před 2 lety +1

    Can you please tell me what’s the thermostat model that suitable for such refrigerators? ( no frost 2 door refrigerator)

  • @jayaprakash-wt1vf
    @jayaprakash-wt1vf Před 3 lety

    Very good clear ....👍

  • @NomanKhan-hr5nd
    @NomanKhan-hr5nd Před 3 lety

    Wao Amazing

  • @deccantraders8711
    @deccantraders8711 Před 3 lety

    Thank q so much sir g

    • @Tech9india
      @Tech9india  Před 3 lety

      Thanks for watching my channel Tech9 india

  • @bagishkulathil8536
    @bagishkulathil8536 Před 2 lety +3

    wrong connection 3 should be neutral, 2 heater , 1 phase and 4 compressor. neutral connection of timer should be come through bimetal.

    • @Tech9india
      @Tech9india  Před 2 lety

      Hello brother.
      Kafi experience hai aap ke paas thanks jo ke aap ne comment kare.
      Brother kya aap Bata sakte hai ke defrost timer kitne type ke hoote hai??
      Godrej . whirlpool. Videocon. in teeno timer
      Ke connection pin me kya defrent hai?
      Aur hum ne is video me kaunsi company
      Ka timer use kya hai.
      Comment zaroor kare aap ke jawab ka intezar rahe ga. Thanks

  • @Robin-lc3wx
    @Robin-lc3wx Před 3 lety

    💖💖💖💖💖👍

    • @Tech9india
      @Tech9india  Před 3 lety

      Thanks for watching my channel
      Please subscribe & share.

  • @kiransagarchalla1609
    @kiransagarchalla1609 Před 3 lety +1

    If possible means can I know the use of bi-metal ?

  • @ahemadrazahalai9860
    @ahemadrazahalai9860 Před 10 měsíci

    Sir plz explain kr sakte hain muje whirlpool wiring me confusion rehta h

  • @farhanmedia5904
    @farhanmedia5904 Před 3 lety

    Tnx

  • @isteevanmangalore9171

    2 for heater

  • @umeshnagvekar7080
    @umeshnagvekar7080 Před 3 lety +2

    Love this video.very clear explanation.
    Thank u

  • @elangovanrealtechengineers541

    Bi metel working time .timer motor working how .nutral no are nc...timer.explane bro

  • @vijaykumarsagar4628
    @vijaykumarsagar4628 Před rokem

    Bi metal on hoga to shot circuit ho jayega

  • @AsifMalik-nz9ky
    @AsifMalik-nz9ky Před 3 lety

    Door open krne sy fan kesy off ho jata ha?

  • @joyshil8502
    @joyshil8502 Před 2 lety

    4 number compressur ka hota hai
    2number heter ka

  • @rajeshchaudhry2603
    @rajeshchaudhry2603 Před rokem

    Hamara purana 7 pin pcb timer ha white Westinghouse fridge ka
    Defrost malfunction ho gaya hai
    Ice zada aur neeche cooling Kam ha.

  • @Crazy_hero
    @Crazy_hero Před rokem

    Door switch ki wire fan motor se kese joden ?

  • @AsifMalik-nz9ky
    @AsifMalik-nz9ky Před 3 lety

    Sir kya no frost ka fan hr wakt on hona chaye

  • @jaimeolano2886
    @jaimeolano2886 Před 2 lety

    Sir may i ask why my ref always running didnt stop automatically.

  • @anilnegi4255
    @anilnegi4255 Před 3 lety

    sir kaam sikhna tha aap kaha se ho

    • @Tech9india
      @Tech9india  Před 3 lety

      Thanks for watching my channel.
      Please subscribe my channel.
      Like & share my videos.
      Bro iam Hyderabad.

  • @dharmaj1171
    @dharmaj1171 Před rokem

    தவறான மின்தொடர்பு

  • @OpiGamer-od5kf
    @OpiGamer-od5kf Před 6 měsíci

    Timer ki netur evva

  • @Ibrahim-tv7rv
    @Ibrahim-tv7rv Před 2 lety

    why start with thermostat? why defrost heater electricity shall pass through the thermostat, what if the freezer was cold with frost buildup? the heater will not work!?

  • @ranjitfernando5241
    @ranjitfernando5241 Před 2 lety

    Before we could observe the complete wiring diagram pictures of the next videos appear and blocks the whole view

  • @multitechservicepoint4917

    Neutral ma OLP ka canection nahi kiya

  • @sujaninilusha2572
    @sujaninilusha2572 Před rokem

    Timer n line not working .

  • @rajeshrobidas4854
    @rajeshrobidas4854 Před 2 lety

    Sir konse apse is video ko banaya hai bolo sir

    • @Tech9india
      @Tech9india  Před 2 lety

      Kinemaster

    • @Tech9india
      @Tech9india  Před 2 lety

      Please like subscribe and share

    • @rajeshrobidas4854
      @rajeshrobidas4854 Před 2 lety

      Jab mouse se line jorte hai tab kinemaster ruk jata hai to kaise karte jo sir koi screen record ka koi istemal kate he ka sir please bolie sir

  • @mdrubelkhan936
    @mdrubelkhan936 Před rokem

    No guut

  • @findout947
    @findout947 Před 2 lety

    Timer connection is wrong you could damage a property.

    • @Tech9india
      @Tech9india  Před 2 lety

      How many type of TIMER S.?????
      VIDEOCON Company TIMER Connection???

  • @ahmadshahbaz8592
    @ahmadshahbaz8592 Před 17 dny

    Dear sum connection wrong

  • @leninssc4472
    @leninssc4472 Před rokem

    When heater mode on same time neutral and main goes one way to heater and other side neutral comes to heater how is possible.
    Wrong

  • @ArmahYeboah
    @ArmahYeboah Před 9 měsíci +1

    Wrong wiring

  • @densagun7361
    @densagun7361 Před 9 měsíci

    Wrong connection

  • @MDRAFI-wn1sh
    @MDRAFI-wn1sh Před 3 lety +1

    Rong connection

    • @Tech9india
      @Tech9india  Před 3 lety

      Please right kya hai bataye bhai

    • @carlosemmanuelgarciabrito791
      @carlosemmanuelgarciabrito791 Před 3 lety

      You right he cannot bring neutral from the heater because if the heater goes bad it will open the circuit and the timer will stop .

  • @moumni7
    @moumni7 Před 6 měsíci

    😂👎

  • @perumalv5807
    @perumalv5807 Před 3 lety

    Nice video

  • @3aliii1979
    @3aliii1979 Před rokem

    Wrong connection