Great video! Can you run 2 Pentair Variable Speed Pump? Filter and water fall feature? If yes, where do you connect the green and yellow cable to the Aqua logic? Theres only 1 slot for green and yellow cables for 2 green and 2 yellow cables.
Thanks for the video! I have a question tho, I am trying to connect the gas heater (with RS Capability) AND the Variable Speed Pump, into the RS System... is there a way to do so? I am using an iAquaLink antena system with an RS4... I have read both equipments manual but haven't figured out if it supports dual use
Does anyone have any experience with the newest version of the Superflo VS pump that also uses a RS-485 automation wiring kit? It appears it would connect to Jandy RS in a similar manner to the video shown. How easy is it to program since Jandy makes no reference to the Superflo?
Would I be able to connect the wires from the com cable of the intelliflo to a separate com port to be placed next to the com port of the iAquaLink antenna as opposed to the same one as you say you don’t “promote”
The wire plugs into the side (on the outside) of the intelliflo pump. The cable comes in the box with the pump, however typically local Pentair dealers have a surplus of cables
All variable speed pumps need to be "Hot Wired" which means it needs to have power all the time. I assume the last pump was a standard single speed pump. The wiring on the filter pump relay needs to be altered. The pump load wires typically on screws #2 and #4 need to be on the Line screws #1 and #3. Watch this video czcams.com/video/x8BKtcQ5uWE/video.html at about 45 seconds I explain how to hot wire the pump. It is the same relays in a Jandy RS system as on an EasyTouch or IntelliTouch system
@@craigwooster6646 Thank you for your help. I can now use pump in service mode. Need help in 2 questions. 1. In service mode what is the speed of pump. Display is inactive, and iAqualink does not provide any information on web in service mode. 2. Is there is any way to use pump in manual mode. Thanks again for your help.
Great video! So crazy how it's designed like that...put the green wire in the yellow slot lol. Thanks for this 👍🏼👍🏼👍🏼
Great video! Can you run 2 Pentair Variable Speed Pump? Filter and water fall feature? If yes, where do you connect the green and yellow cable to the Aqua logic? Theres only 1 slot for green and yellow cables for 2 green and 2 yellow cables.
Great short video! Let me ask you which aqualink model is this one, I want to do this and I believe I have a R6 . Thanks in advance.
Mystery solved. Thanks for this.
Thanks for the video! I have a question tho, I am trying to connect the gas heater (with RS Capability) AND the Variable Speed Pump, into the RS System... is there a way to do so?
I am using an iAquaLink antena system with an RS4... I have read both equipments manual but haven't figured out if it supports dual use
Does anyone have any experience with the newest version of the Superflo VS pump that also uses a RS-485 automation wiring kit? It appears it would connect to Jandy RS in a similar manner to the video shown. How easy is it to program since Jandy makes no reference to the Superflo?
Would I be able to connect the wires from the com cable of the intelliflo to a separate com port to be placed next to the com port of the iAquaLink antenna as opposed to the same one as you say you don’t “promote”
Great video. I have it wired. How do I program it now?
Do you get full capabilities when using the intellaflo3 ? ( speed adjustments, spa setting, setting a general schedule)
Did you ever find out?
Can you show where the 2 wires terminate inside the pump please?
The wire plugs into the side (on the outside) of the intelliflo pump. The cable comes in the box with the pump, however typically local Pentair dealers have a surplus of cables
Do you have a video on how to connect jandy flowpro to rs onetouch system?
That’s what I’m trying to figure out? Did you get it?
When I put Iaqualink in to service mode my Inteliflow VSF model 011056 pump has no power, I have iAqualink IQ 900.
All variable speed pumps need to be "Hot Wired" which means it needs to have power all the time. I assume the last pump was a standard single speed pump. The wiring on the filter pump relay needs to be altered. The pump load wires typically on screws #2 and #4 need to be on the Line screws #1 and #3. Watch this video czcams.com/video/x8BKtcQ5uWE/video.html at about 45 seconds I explain how to hot wire the pump. It is the same relays in a Jandy RS system as on an EasyTouch or IntelliTouch system
@@craigwooster6646 Thank you for your help. I can now use pump in service mode. Need help in 2 questions. 1. In service mode what is the speed of pump. Display is inactive, and iAqualink does not provide any information on web in service mode. 2. Is there is any way to use pump in manual mode. Thanks again for your help.
does not work