  • Power on the Hanover ERIC controller with external power supply unit and read out the route data using USB-Serial converter to PC
    Hanover Display DERIC controller
    Power: DC 24V, Meanwell LPV-150-24 supply unit
    USB-RS232 converter: UC232A, ATEN international Co. Ltd.
    Serial port software: Free Serial Port Monitor
    Baud rate setting: 19200-8-N-1 No flow control
    Hex editor: Frhed
    #HanoverDisplays #ERIC #Hanover電子牌 #巴士

Komentáře • 6

  • @tortipoof
    @tortipoof Před 3 měsíci

    Once you(ve done that, how can you open the dumped data with Helen ?

  • @TheArkamedBat
    @TheArkamedBat Před rokem +1

    That is a Deric, not an Eric. The Eric controllers have more buttons, including a number keypad. The Deric ones don't.

    • @samchan1031
      @samchan1031  Před rokem

      had you read the info box?😊

    • @TheArkamedBat
      @TheArkamedBat Před rokem +1

      @@samchan1031 Yes, but firstly it says that it is a ERIC, while below it says that it is a DERIC. That's a DERIC+.

    • @samchan1031
      @samchan1031  Před rokem +1

      ​@@TheArkamedBatyes, they all share the same method of reading data, unless the company has a tailor made firmware inside (which i dont know how it looks like)