Sir mera jina niche se landing tak 8 fit hai our uski uchai 5 fit hai our jine me hamne sariya 5 inch par our aade bala sariya 3.5 our 4 inch par diya hai par diya hai our ek sit 4 inchi diwall par rakha hai usme ek misteck hogai hai sidi ke niche 4inch ka bes hona chahiye oh 2 our 3 inch ka hai sir usme hamne loha bahut jyada dala hai Sir our majbuti ke liye koi upay bataiye place
Sir mera jina niche se 4fit uncha hai our 7fit uski lambai hai our jine ki chaudai 2.5 fit hai our ek site dibal ME chiptate gaya hai sirf sirf uska bes 2 se 2.5inch mota hai sir aagr meri bat apko samajh me nahi arhi to plice apka contect nambar ek Minute bat karni hai
@@CivilEngineerDeepakKumar sir Maine aapko mail kiya tha ....column reinforcement ki detail se related.....to aasa krta hun ki bhut jldi mujhe uska reply milega.. ....... meri e-mail I'd- maithaniankit276@gmail.com
sir, bohot jagah dekhte hai, ki koi company bolti hai.....humara reinforcement 550D, 600D, hai........kya sahi me hota hai? kyu ki humare IS456:2000 me to 500 tak hi limited hai.... aur ek sawal, circular staircase ka ek detailing sikha dijiye please.
क्या सीढ़ी को दोनों ओर से दीवाल का सपोर्ट देना जरूरी है? अगर सीढ़ी के एक साइड को दीवाल पर नहीं चढ़ाया जाए तो क्या होगा। क्या रेन्फोर्समेंट के डिज़ाइन में भी फर्क करना होगा?
Deepak ji gd evning Mera ek bath hy Roomki andar kitiki ka uper hamlog sajaa boltha hy Kithana thickness banega Kithna width banega kitchen me banatha hy saman raknekeliye Kithna ml steel /sariya dalneka
Bhai Jo reinforcement aap dikhaye hai ...aise galat hai... Waist slab se bottom ka rod upar ka slab ka top mein ja k bending lap karega...minimum bending lap 500 mm dena chahiye 300 mm nehi bhai...galat mat samjhao...logo ko..
Dekhye Surendar G ... Apka plot agar Road se down h to koi baat nhi ... Bo depend karta h ki apki Road Kaisi h Kaachii h ya phirr Pakki h . Q ki agar road apki Nyi or pakki h to ab Plinth ki height 600m or 900mm rakh sakte h Ye Aacha rhega ...
आप बहुत अच्छी जानकारी बताते हैं बहुत-बहुत धन्यवाद सर आपको
Thanks
Nice knowledge sir....salute u
thank you
Very good sir nice video please take care
thanks
👍👍👍 mast. Aap ka channalwa subscribe kar liya bro. Mast batate ho, bilkul clear.
thank you very much Mukesh Ji
sir ji unit ekhi rakho inch me foot mein kauki apne 24'' kara landing reinforce ka dekho
Sir apka video dekh ke mujhe cation dekhne a giya
Very helpful video sir
thanks
Ventilated stairs kase banega sir please help me. Mai ne dekha tha delhi mein kisi ghar mein only centre mein piller jesa rehta hai baki open.
Niche wall nehi he long 12 ft he 12 mm rod de to hoga kya
Sir I would share my stair case reinforcement.... Am little bit confused
Kithna ml sariya daltha hy hooo sajja ko
Sir three liyar shidhi kese banye
Sir plz make a video on how to use auto level during excavation of foundation both using NGL and plinth level
ok
Sir ek karkat ke gr ka naksa bna sakte hai kya
Angel of elevation kya liya hai
Stare Mein 10 foot ke Patte Mein Kitni gitti lagti Jiske bad Mein suli Chadh jaenge Kitni cement Lagti Hai bataiye
Awesome sir
thanks
13'5" labai chathal haghit kitna hoga please jaldi vedio karo
Can I use 10mm,8mm bar
Thank you sir
10 mm ka sariya de diya hai mistri is se koi dikkat hoga kya sir plez bataye
Sir mera jina niche se landing tak 8 fit hai our uski uchai 5 fit hai our jine me hamne sariya 5 inch par our aade bala sariya 3.5 our 4 inch par diya hai par diya hai our ek sit 4 inchi diwall par rakha hai usme ek misteck hogai hai sidi ke niche 4inch ka bes hona chahiye oh 2 our 3 inch ka hai sir usme hamne loha bahut jyada dala hai Sir our majbuti ke liye koi upay bataiye place
send your plan
Thanks
सर जरा छड़ निकालने का फार्मूला बता दीजिए प्लीज
Sir mera jina niche se 4fit uncha hai our 7fit uski lambai hai our jine ki chaudai 2.5 fit hai our ek site dibal ME chiptate gaya hai sirf sirf uska bes 2 se 2.5inch mota hai sir aagr meri bat apko samajh me nahi arhi to plice apka contect nambar ek Minute bat karni hai
Sir sidi mei kitna steel cement legta hai
Staircase aise thoda samjne pe muskil lagta he site pe ek video banaye
Sar sidio ka renga kese banae
Great sir..🙏🙏
thanks
@@CivilEngineerDeepakKumar sir Maine aapko mail kiya tha ....column reinforcement ki detail se related.....to aasa krta hun ki bhut jldi mujhe uska reply milega.. .......
meri e-mail I'd- maithaniankit276@gmail.com
@@ankitmaithani1241
ok mai reply karta hu aaj
@@CivilEngineerDeepakKumar thanku sir...
Sar mera ghar me 12fit lambai hai 6fit choda hai or 2fit bahar total 14fit 10inch hai to sidhi Ka step kitana hoga
Beam se saria kaise connect karu???
Thanks.sir.
thanks
Sir ek chiz nehi bataya .....chair bhi lagega usske bare me kuch b nehi bataya sir
Sir aapka me fen hun
thanks
Sir jo sariya h bo diwar main fashai jayegi
Sar.ham.jeena.ke.neeche.get.rkhna.chahte.he.chat.ka.hait.10.fit.lambai11.fit10enh.chorae.7fit.he
Spiral staircase ka detail me batye sir
ok
Aap cover nhi btaye ki kitna liya jayega buttom aur top m
sir, bohot jagah dekhte hai, ki koi company bolti hai.....humara reinforcement 550D, 600D, hai........kya sahi me hota hai? kyu ki humare IS456:2000 me to 500 tak hi limited hai....
aur ek sawal, circular staircase ka ek detailing sikha dijiye please.
Sar. Mera 20/43 fit ka ariya hai iska naksa btai na jo charo traf se wendow ho dakhin face kapalot hai
ok
Good
thanks
Landing का top bar full length beam तक जायेगा भाई
cut steel ya full steel
कृपया मेरा भि एक समस्या का हल निकाल दिजिए बहुत कृपा होगा ।
Space 10*10
floor height 10.6"
Riser size 6"
Tread 12"
width of staircase 4.5"
lambi.val sarya 12 mm aur chaudi 10 mm dono ke beech ki duri nahi samajh aayi
👍👍👌👌✌
thanks
Purane dewal ke ghar ko kaat kar beam kaise dale?
2 bissa me 4 manjeela banana hai kitna kharcha ayega.help
क्या सीढ़ी को दोनों ओर से दीवाल का सपोर्ट देना जरूरी है? अगर सीढ़ी के एक साइड को दीवाल पर नहीं चढ़ाया जाए तो क्या होगा। क्या रेन्फोर्समेंट के डिज़ाइन में भी फर्क करना होगा?
4sq meter me ban jayega kyaa????
Sir, mene mere ghar ke stair case mein 10mm Tata Tiscon SD ka saria diya hain isme koi problem hoga kya?
No problem
8 by 8 Mai jina kaise
Kuch bolchal bhasha me bhi jor de sir please
good, pls add site demo video
ok
1000 kg ka steel baandhane me liye kitna time aur labour lagata hai
Iss pe video chaiye
Sir aap kaha se ho
11 फीट लंबाई 7 फीट चौड़ाई और छत का हाइट 11 फीट इसको तीन लैंडिंग में चढ़ाना है पूरा डिटेल में समझा सकते हैं
Isme jada kharcha hai ki zigzag main jada kharcha hai?
लेंडिड स्टील 12एमएम का टॉप बॉटम darekt दे सकते ।
सर हिडन बीम कितने की रूम में डाली जाती है और कै से
Deepak ji gd evning
Mera ek bath hy
Roomki andar kitiki ka uper hamlog sajaa boltha hy
Kithana thickness banega
Kithna width banega kitchen me banatha hy saman raknekeliye
Kithna ml steel /sariya dalneka
thickness 100mm
use 10mm steel @150c/c
सर फारमुला बताउ सीधा सीढी बनाने का आप जो ख़ाली जगह जरा किलिएर बताउ
Top se Jo bottom reinforcement dikha rahe hai wah pura wall me q sata rahe hai
Jabki cross section me 24 inch hi landing per charha rahe hai
hmm
1200sq ft ka home banane m kitna amount lagta h group floor banane m. reply
17lakh
Lenter ki 11
Sir me 6*10 me chedi keashe banay
Lantern maleiya
Upr k seedhi ko bnane k liye kitna feet rod chor de
Full length bottom
कितनी ऊंचाई तक जा सकती है 7 fit ya 8fit
samjha nahi
Sir mene jine ka plan sand to kar diya our koun sa plan sand Karin
kahan bheje hai
Sir ji Aap ka what's up no chaiye mujhe aap se ek map ke baare me discuss karna hai
Sir 6 inch bahut wast slab mota hoga
4 inch better hai
hmm
Bhai Jo reinforcement aap dikhaye hai ...aise galat hai... Waist slab se bottom ka rod upar ka slab ka top mein ja k bending lap karega...minimum bending lap 500 mm dena chahiye 300 mm nehi bhai...galat mat samjhao...logo ko..
SIR ISKA STEEL QUANTITY BOLIYE SIR
ok
Room me do thrafh bantha hy sajja
Hindi me kya bolthi hy muje malum nahi
chhajja hi bolte hai
Sir site engineering ki video do
ok
Navin Solanki
Nakasabanakedoge
8 ft by 16 ft is too much area for a stairs, best size 10 ft by 7.5 ft for residential building
लैंडिंग कितनी उचाई पर होनी चाहिए
half of building height
Watis meaning of center ceter
bich ka duri
sir are taking coaching class
Not now
Sir cost Jara Bata detey to help hojayega.
ok
video coming soon
Plans banana h sir 6 room ka
Sir whr r u from?
Bihar
Halo sar
halo
Sir piece aap ka contect nambar dena aap se thodi bat karni hai aapki har video me dekhta hun meri chhotisi ek samasya hai
check About tab
Beam aur column me 5mm ka ring dena sahi rahega kya
nahi
खर्चा भी बता देते सर
Ok
Sir mera comment jaldi bapas karo
Ghichpit ghichpit
ohh
Main bar shorter span main provide karte hai aapne longer span main provide Kiya hai ? Kyon ?
you are wrong
send me this type of drawing in my email id
Hey u should learn during placing of steel.. It will be more clear ur vision.
Hello
hello
Isir I want to talk to you how can it be possible ?
send email for this
ये भिडियो बिलकुल ही अच्छा नहीं रहा.☹️
ohh
ᴄʜʜᴀᴛ ᴍᴇ ꜱɪᴅɪ ᴋᴀ ꜱᴀʀɪyᴀ ʜᴏɴᴛ ᴋᴀɪꜱᴀ ʜᴏ ɢᴀ ꜱʀ ʙᴀᴛᴀyᴇ
yes
Deepak bhaiya ek Ghar ka naksha banana h apna what's up no. dijiye
aap mujhe email kare
Sir besment she Roth floor tak Steyer me kitna church ho ga sir 9971751875 arjent hai
App apna no dijye ga drowning bhej dunga sir
Thanks sir
thanks
Good
Thanks
Sir Mera plot road key level se 7 feet down h. Plenth beam kitni hight/feet per Dena hoga
Dekhye Surendar G ...
Apka plot agar Road se down h to koi baat nhi ...
Bo depend karta h ki apki Road Kaisi h Kaachii h ya phirr Pakki h .
Q ki agar road apki Nyi or pakki h to ab Plinth ki height 600m or 900mm rakh sakte h
Ye Aacha rhega ...
600mm yani 2 feet
900mm yani 3 feet ...
agar baris ka pani wahan jama nahi hota hai to 1 feet le sakte hai
nahi to road 7 feet se v jyada lena hoga
Go with a basement option if your plot is at a very low level as compare to road.
New Road h Deepak ji