Video není dostupné.
Omlouváme se.
AC COMPRESSOR TRIPPING PROBLEM ठीक कैसे करे.
Vložit
- čas přidán 11. 08. 2020
- #REFRIGERATIONFULLSOLUTIONS #RS
--------------------------------------------------------------------
YE VIDEO AAP KE LIYE HAI AC COMPRESSOR TRIPPING PROBLEM SOLVE KAISE KAREN.
MY CZcams CHANNEL SUBSCRIBE OPEN LINK :- / @refrigerationfullsolu...
LG DOUBLE DOOR FRIDGE COOLING PROBLEMS OPEN LINK :-
• LG DOUBLE DOOR FRIDGE ...
OUTDOOR UNITE OR INDOOR UNITE MAI ALAG ALAG PRESSURE KAISE DALE OR KITANA DALE
OPEN LINK. :- • Outdoor Unit Or Indoor...
#RS Split AC Gas restore कैसे करे.
OPEN LINK :- • Split AC Gas restore क...
Mitsubishi AC Mai OUTDOOR UNITE Wiring Compressor Relay With Fan Motor & Capacitors In Hindi OPEN LINK. :-
• Mitashi AC Outdoor Uni...
-------------------------------------------------------------------
Keep Support Me.....
Keep love.....
Keep Like....❤
Keep Share.....
Keep Comments.....
Keep Subscribe This Channel......
MY CHANNEL NAME :- REFRIGERATION FULL SOLUTION 💪😄👌
PLEASE SUBSCRIBE MY CHANNEL PLEASE PLEASE PLEASE MY DEAR 💕👭👬
________________________________________
****THANKS FOR WATCHING****
Aap jesa koi sikhata nahi
Thanks
Dil khus ho gaye sir
Nice video sir ji 👌
assalamu alaikkum.masha alla.aajki ye videome zabardast pointsne aapney bolahai compressor tripingka reasons.great...super...excellent....keep it up.
Walaikum assalam bhai jaan Allah paq aap ko salamat Rakhe
@@RefrigerationfullSolutions aapku aur aapki pariwarkubi allapak sehthi thanthuristi aur dawlad diye.
Good
Bhai. Very nice video
Good information sir
very nice imformation
Good guidance
GOOD
Good information
Nice sir
Good bro
Sar aapke video mein aur aapke reply mein Ek chij bahut badhiya Lagi Mujhe jo aap bolate ho na theek hai theek theek hai theek ok👌👌👌👌👌
Thanks my dear friend habit main theek hai
Thanks
Good experience
Sir compressor not working, outdoor fan working, how to repair 1.5 T split ac please reply. Capicitor already changed. Indoor air blowing without cooling.
👍
Valekum asslam bai i Rahaman khan, NCL buildtek LTD. My house 🏘️ AC Daikin R 32 5 secund run after trip. running time 3 ampes not e.tell me bai.
Aap compressor direct chalao fir dekho kitni der tak chal rah h agar wo 5 - 10 minutes chalta h to aap ka compressor fault h to aap ye check karo fir aap batana thik h bro
Bai your AC video i looked this so our AC Daikin R 32 invatar modal.i Electrical department persons. I own fix the Last year.resent this prabulam.tell the comment. ME.
Nice information bro
Split ac ke outdoor ka fan band ho jata hai uske bad compressor band ho jata hai to kya kare
Non इनवर्टर की pcb ko kaise check kare
Sir ek help chahiye emergency wali...mera blower wheel phas gaya hai....badi mushkil se motor kholke to nikal gya but vapas jane m problem kar raha h...pls help
Mera same ac he
2ton mera room 110 sqft he
15min me cooling ho jati hai jab 26/27 pe rakhte hai aur baar baar trip hota hai usse jyada thanda nahi chahiye is lie 28 pe rakhte hai
28 pe continue chale isliye kya kare ?
Senser nikal de kya ?
Aluminium candenser leak ho gaya to ab copper condenser dala hai naya
Sensor check karo dono room sensor and coil sensor check karo aap ki problems solve ho jayegi bro
Agar machine ke uppar 6.5 Amp likha ho to kitna Amp aana chahiye?
7 amp
Wiring ke liye video bana do brother
Ok
Sir ac ka a to z reper ka videyo rakhe..
Ok ji
Sir ji apna outdoor unit ka line neutral short hogya hai continuity arha beep kar rha, kya karu koi fixing bataye
Wire check karo aap kahi se short h warna aap new wire laga do thik h
@@RefrigerationfullSolutions sirji mai compressor ki line khol dene se chal rha, wo condenser fan but compressor connect kiya toh breaker trip hogya, kuch hal hai iska
Aap aapna ac dusre switch se chalao or agar MCB break ho toh aap ka compressor short goya y wire kahi se shot h outdoor fan motor bhi short ho sakta h aap check karo thik h
Meri ac 26°C or uski upar ki temperature pe ac trip ho raha hai!
Have full video
दो मीनट मे पुरा आउटडोर बंद होता है दो मीनट बाद चालु होता है क्या प्रॉब्लम होगा continue ये ही प्रॉब्लम है
Amp kitne le raha h compressor batao bhai
Sr boht acha humara sub kuch thik hai but outdoor me awz me aati hai ..sb kuch her saal dikhwate hai thik he rehta hai kyo aa rh hogi normal Voltas h split outdoor raat ko lgta hai zyda awZ kr rh hai din me kbhi kbhi chalao to ni aati itna sound mai delhi jail road se hu sr cleaning kitna zaruri h ac ka ye b bnaye
Kitna puran h ac
@@RefrigerationfullSolutions sr hmara ac h 2013 ka bt jo outdoor tha hmne last yr change kraya qk meri frn ki b same dikkat thi her saal taka tutna gas niklna same hmari b ..to humne phir Se copper vala he le lia meri frn ne b yhi lia unka or hmara thik chal rh hai ..bus awz kr rh hai last yr jb badla to capistor change kra or ander indoor ki pcb bus baki sr boht dukhi kra tha outdoor me dukhi kya rula dia tha literally boht ..sparking krta kbhi taka tut ta kbhi gas leak gas leak to do saal me do bar hui hm to ac ajkl me 4may se chalate hai sirf two hrs ..hard core ac chalane vale n h hum k 15-18 hrs chalao jb garmi lgi tb one hr chala do zaruri ni rat me chalao islye hmare service vale aakr kehte hai kbhi itna chal gya..vese ek bat or perso pressure vali service ki ek do bar cheeta mara pani ka kyo?
Aap number send karo thik h
Walekumasslam bhai
Subha or raat ko thik chalta h ac
Or dhoper ko triip karta h
Kya problem h sir
Kitna puran h ac or copper mai ac ya aluminium mai batao aap
New compressor name
Sir 7 din purana invertor ac h 10 min chalta h fir compressor band ho jata hai fir 10 min bad fir s chalu ho jata h kya dikkt ho skti h
Service check karo clean h ac
@@RefrigerationfullSolutions 7 din m m hi
@@PRIIYANSH same mera v ek week hua h voltas ki ac h
Aap ac technician ko check karo
Mera hitachi ka invter ac hai or uska problem ye hai ki thoda sa v voltage up down hone se trip le leta or kuch der bad fir se start hota hai Kya problem hai
Agar voltage ki problem h toh aap steblizer laga do problem thik ho jayegi
@@RefrigerationfullSolutions steblizer laga hua hai 5 kv ka
Running mai voltage check karo bro
Sir spirit ac outdoor fan chalta ha compressor ke thimbel lga do mcb trip ho jata ha reply plz
Compressor winding check karo wire check
@@RefrigerationfullSolutions sir agar thimbel Galt lag jay to keya problem Hoge
Hn hogi trace kar lo connection
@@RefrigerationfullSolutions sir compressor check kra leya compressor kharab ho geya
@@RefrigerationfullSolutions lg ac ha split ac 1.50 ton ka compressor ka keya price hoga
Mera 4 minutes me treep ho jata hai please bataye har bar 4 minutes me treep ho jata hai please bataye
Aap video dekho sab pata chal jayega aap ko thik se check karo jo batai h agar koi problem to bata dena thik h
بھائی صاحب میں پاکستان سے ہوں میرا Ac کا کمپریسر 7 منٹ چلتا ہے اور 3 منٹ بند ہوتا ہے اس کا حل بتاۓ کیا مسلہ ہے جب کمپریسر چلتا ہے اور کمرہ کول ہوتا ہے جب بند ہوتا ہے تو کمرہ گرم ہوتا ہے
हमारा स्प्लिट AC जो कि डेढ़ टन का है उसका कंप्रेशर 3 मिनट चलता है और तीन ही मिनट बन्द रहता है और अगर उसको ड्राई मोड में चलते है तो कंप्रेशर ठीक चलता है मतलब ठीक चलता है तो ठंडक भी ठीक होती है पर cool मोड 3 मिनट ही चलता है ऐसा क्यों बैक प्रेशर 65 है और स्टैंड प्रेशर 165 से 170 है
Pcb agar cooling mode par sence nahi karti h to aap ki pcb fault h kyoki agar diry mode par thik chal rah h to aap ke sensor to thik h par pcb fault h
@@RefrigerationfullSolutions pcb में क्या फॉल्ट हो सकता है ओर अगर रही कूलिंग मोड में सेंस करने की तो 3 मिनट तो कंप्रेशर चलता ही है और तीन मिनट ही बन्द रहता है ऐसा लगता है मानो इसमें टाइमर सेट कर रखा हो लास्ट टाइम जब PCB रिपेयर कराई थी तो दिक्क्त ये थी कि इनडोर बन्द हो जाती थी पर आउट डोर चलती रहती थी इसी वजह से PCB को रिपेयर कराया था
Mera inverter AC hai have 5 MIN me Mera compressor band ho jata hai
Supply check karo bro
mai to paresaan ho gaya baar baar trip ho rha hai
Bhai 1 trippin ka course upload kar diya h usme competed information h aap videolist me jake dekh lo 5 parts h
Ac 10 mint bad cut Kar janda a
Ac kitne amp le rah h or compressor head ho rah h ya nahi
App apna nambar send me
Good information sir
Good information