Primary-Secondary Chilled Water Systems | HVAC Chilled Water Distribution System | HVAC World

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • Hell guys!!
    HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
    so plz
    LIKE | COMMENT | SHARE | SUBS C R I B E
    Keep Sharing - And Subscribe For More Updates...
    THANK YOU.

Komentáře • 142

  • @HVACWorld
    @HVACWorld  Před 4 lety +9

    Let's have 100 likes for this video

  • @abhilashac3988
    @abhilashac3988 Před 2 měsíci +1

    Very good👍👍

  • @mdshahbazgaddi5319
    @mdshahbazgaddi5319 Před 3 měsíci

    Very nice explain thanks

  • @amarjeetbadhan9593
    @amarjeetbadhan9593 Před 2 lety +1

    Very very knowledgeable video. 🙏🙇

  • @hvacshailendarshahganjup9464

    Good 👍

  • @prakashbaby9189
    @prakashbaby9189 Před 6 měsíci

    Nice explanation

  • @RAVIKUMAR-hd1gk
    @RAVIKUMAR-hd1gk Před 10 měsíci +1

    Bahut khub sir excellent

  • @krishnarajsaradha8653
    @krishnarajsaradha8653 Před 2 lety +1

    Very good explain thank-you sir

  • @jarugumallipavankumar7161

    Very good explain sir thank you.....

  • @muhammadjamilfaiz1173
    @muhammadjamilfaiz1173 Před rokem +1

    Very nice informations.

  • @guddumishra5655
    @guddumishra5655 Před 2 lety +1

    Very good explain boss lot's thanks

  • @akhtarreyaz376
    @akhtarreyaz376 Před rokem +1

    Meaning content

  • @ssraorao7565
    @ssraorao7565 Před 3 lety +1

    Thank you very much sir now i am got secondary pipe line and primary pipe line bypass valve (decouple)🙏

  • @mdmohi5635
    @mdmohi5635 Před 7 měsíci +1

    Best explanation ❤

  • @Samshiralam
    @Samshiralam Před 3 lety +1

    Sir acche se explain krte ho, main abhi kuch din pahle hi aapke chanel pe aaya hu, or mujhe acchi knowledge mili hai

  • @alok0734
    @alok0734 Před 2 lety +1

    Thank you for eloborating so clear and in simple words. Appreciate your efforts, keep doing good work.

  • @kumarsong855
    @kumarsong855 Před 3 lety +1

    Very nice Information... your explanation way is very Good

  • @sharanupujar5462
    @sharanupujar5462 Před 2 lety +1

    Thank u so much sir.... Really I loved it.... thanx alot

  • @shahikhan5637
    @shahikhan5637 Před 3 lety +1

    Bahut achcha samjhaya aap ne

  • @golamnur989
    @golamnur989 Před 3 lety +1

    I have been following your channel from quite long time. Every video is very informative. I am benefited alot from your video. My humble request make a video on
    1. Chemical dosing (matual and automatic)
    2. Chilled water pressurisation unit
    3. Chilled water line flushing (most needed).

  • @tinkurajrajsingh8589
    @tinkurajrajsingh8589 Před 3 měsíci +1

    Nice sir

  • @A.AHAD123
    @A.AHAD123 Před 3 lety

    awesome information

  • @skbarua7677
    @skbarua7677 Před 3 lety

    Wow...great....thanks dear

  • @saimathecalligrapher
    @saimathecalligrapher Před rokem +1

    Love you sir

  • @usmanahmed8842
    @usmanahmed8842 Před 4 lety +2

    Sir first question k reply k liay thanks clear ho gya he, mera second question ye he k Ap nay jasy btya k off load pay jo return air ay gi us ka temperature b 56 rhy ga lakin jo water by pass ho raha he secondary pump say us ka temperature tu 44 hi rhy ga, is terha jb AHU ka retrurn Aur by pass ka water mily ga tu temperature 56 say km ho ker 50 nhi ho jay ga same constant volume system ki terha?

    • @HVACWorld
      @HVACWorld  Před 4 lety +2

      Video me maine explain kiya h k part load pe hmara 3 chiller me se 1 chiller off ho jayega or uske sath sath 1 primary pump v off ho jayega...jaise hi primary pump off hoga us case me bhut hi come amount me CHW bypass hoga jisse CHWR k temperature me bhut minutes difference ayega jiski wajah se baaki ke 2 chiller unload hone shuru jayege jisse k hmari power consumption come ho jayegi..ek chiz mai or add krna chahunga k primary-secondary system me secondary pump ka water flow maximum case me primary pump se zyada hota hai, kyu ke building me bhut sare equipments hote h to secondary loop me zyada GPM chahiye hota hai..isliye water bhut kam amount me bypass hota hai...

    • @usmanahmed8842
      @usmanahmed8842 Před 4 lety +1

      HVAC World thank you sir for your explanation

  • @mdaafanhasan2651
    @mdaafanhasan2651 Před 4 lety +1

    Awsome

  • @afrozroushan5194
    @afrozroushan5194 Před 3 lety

    Zbrdst bro ultimate appko professor hona chahye goood knowlage

  • @VikasSingh-sq8pk
    @VikasSingh-sq8pk Před 3 lety

    Excellent explain sir

  • @ankitpathade7023
    @ankitpathade7023 Před 3 lety +1

    Excellent explanations sir

  • @rezashahid7768
    @rezashahid7768 Před 4 lety +1

    Excellent sir ji

  • @ASADKHAN-xb3vn
    @ASADKHAN-xb3vn Před 3 lety

    Great Sir

  • @singhsingh-ip1sc
    @singhsingh-ip1sc Před 3 lety

    Nice video

  • @joydipghosh3273
    @joydipghosh3273 Před 2 lety +3

    What is the process of calculation of de-coupler pipe size???

    • @KashifKhan-rd8ts
      @KashifKhan-rd8ts Před 2 lety

      Ek size chota le kr connect kr do, part load pe chiller run karega, kabhi bhi 100% water to return lena nhi hai decoupler se.

    • @javeedhvactechnician7760
      @javeedhvactechnician7760 Před 8 měsíci

      czcams.com/video/KQEh6t7pdCw/video.htmlsi=gvbqOfQpDHeg804C

  • @sunnymodi9393
    @sunnymodi9393 Před 2 lety

    DP sensors & Temp sensors are liittle bit tricky & technical, explained well though

  • @usmankhalid1806
    @usmankhalid1806 Před 3 lety +1

    Sir agar load 100% acheive ho geya hai or 100gpm 44 F water secondary pump k through chala geya or 100gpm 44 F decoupler line se primary motor mai a geya than ye 100gpm with 44F and return se 100gpm with 56F mill ke low delta T nahi ho jeya ga?

  • @ranazubairkhalid9447
    @ranazubairkhalid9447 Před 11 měsíci

    Love you bro

  • @usmanahmed8842
    @usmanahmed8842 Před 4 lety +1

    Sir Ap nay jis terha video me kaha k jb aik AHU ka 2 way valve close ho ga tu dosry AHU ka b 2 way valve close ho jay ga Aur load kam ho jay ga but mera question ye he k her aik floor ki apni cooling requirement hoti he suppose AHU #1 pay load km hota he tu lazmi tu nhi he k baki AHU ka load b km ho?

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Mere kahne ka mtlab hai k jaise jaise floor pe temperature achieve hota jayega waise waise us AHU ka 2-way valve usi ratio me band hota jayega or jisse k ahu k accross water flow kam hota jayega or wo water Bypass line se cross ho kr primary me chala jayega....aisa ko rule nhi h k at a time sare ahu ka valve band hoga..ye understood hai k valve tab band hoga jab room ya floor ka temperature achieve hoga.....I hope ab aapko clear ho gaya hoga... comment kr ke confirm zarur krna.. thank you

    • @usmanahmed8842
      @usmanahmed8842 Před 4 lety

      HVAC World G thanks

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY Před 3 lety +1

    excellent video, u said PDS will be installed at high level, why? might i will got required temperature at low level floor, 2ndly if i have industry and all AHU,s will be on one roof horizontally, where i have to install PDS?

    • @KashifKhan-rd8ts
      @KashifKhan-rd8ts Před 2 lety

      Hi, I think we receive the highest pressure at the last ahu either in case of vertically placed or in horizontal placed AHUs, that's why we are installing PDS there.

    • @javeedhvactechnician7760
      @javeedhvactechnician7760 Před 8 měsíci

      czcams.com/video/KQEh6t7pdCw/video.htmlsi=gvbqOfQpDHeg804C

  • @alamroushan9351
    @alamroushan9351 Před 2 lety +1

    Chlir or cling tawor ka keya cantion rahta hai plz Ripley

  • @muhammadswalih5989
    @muhammadswalih5989 Před 7 měsíci +1

    Why Ur installing modulating valve at the chiller outlet, on off valve is enough

  • @4umahin
    @4umahin Před 2 lety

    Good explanation...but what will happen if in case valves of secondary pump circuit are closed and PP is still running? Like, is it possible if there may be no secondary pump?

  • @MohdJaved-oq8bn
    @MohdJaved-oq8bn Před 3 lety +2

    Sir bms systems ke bare m bataiye

  • @kashifiqbalzafar
    @kashifiqbalzafar Před 4 lety +1

    Sorry sir , I missed your live session today.
    Excellent explanation..

  • @meesamkazmi0512
    @meesamkazmi0512 Před 3 lety +1

    Sir jb load km hoga decopler line mai jayega to kya secondary pupm ki frequency km hogi ya same speed pe chalega

    • @HVACWorld
      @HVACWorld  Před 3 lety +1

      Secondary pump ki frequency kam ho jayegi jisaki wjh se secondary pump ka RPM kam hoga or water flow v kam ho jayega jo energy saving ka sabse bada reason h

    • @meesamkazmi0512
      @meesamkazmi0512 Před 3 lety +1

      @@HVACWorld sir agr water flow km hoga to primary pump k liye bhi water suction km hoga kya

    • @HVACWorld
      @HVACWorld  Před 3 lety +2

      Nahi...wo decoupler line se water suck kr lega

    • @meesamkazmi0512
      @meesamkazmi0512 Před 3 lety +1

      Ok thnku sir

  • @usmankhalid1806
    @usmankhalid1806 Před 3 lety

    And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?

  • @alishnawa1108
    @alishnawa1108 Před 2 lety +2

    Is there any English Version for ur valuable lectures ?

  • @suru7593
    @suru7593 Před rokem +1

    Would it be possible to create the chiller selection for various applications, such as commercial and residential, as well?

  • @abdulraqeeb6514
    @abdulraqeeb6514 Před rokem

    Excellent very informative , just tell me what is roll of thermoste in the room , and it is linked to return air sensor ? Please.

  • @johnphilip7084
    @johnphilip7084 Před rokem +1

    dps which line it be placed,as there is 2 rises supply return.which floor it be placed if it is 6 floor building,

    • @HVACWorld
      @HVACWorld  Před rokem

      DPS has two ports, one portt will be connected to Supply line and other one will be connected with Return line to get the pressure difference between supply and return line

  • @subhashvasava6540
    @subhashvasava6540 Před 3 lety +1

    Humidity temperature KV Ritesh Himalaya temperature Ben 10

  • @abhijitpalai6540
    @abhijitpalai6540 Před rokem

    Sir achutor kese manual open close karte hai ek bar bataye plz video me🙏🙏🙏

  • @hamzabadar3386
    @hamzabadar3386 Před rokem +1

    Hmra jo primary pump ha wo b vfd sa control hota ha.. sir.

  • @nishantsh03
    @nishantsh03 Před 3 lety

    Hot well and cold well kya hotabhai sir... Or hot well se connect kya hota hai primary pump or secondary pump

  • @AshrafKhan-xu4wk
    @AshrafKhan-xu4wk Před 4 lety +1

    Sir apna 2 chiller 200tr
    iska GPM 800 hua but mera questions ye hi ki sir building ka load 50 percent hua toh vsd pump slow hua ab building ko 400gpm chahiye ye decopler line h vsd pump ke inlet and primary pump ke inlet se connect h sir ye samjh nhi aa raha h apna primary pump constent h ye depcopler se 800gpm le lega building 400gpm nhi ja payega sir depouler par automatic valve hona chahiye ki building ka 50 percent load ho toh decoupler valve se 50 percent water bypass ho

    • @HVACWorld
      @HVACWorld  Před 4 lety +1

      Good observation...jab building 50 prcnt pe operate hogi to schematic k according usko 600 GPM chahiye hoga or hamara primary pump 800 GPM delivered krega jisse decoupler se 200 GPM by pass hoga..ek point maine add nhi kiya jo mai add krna chahunga... primary-secondary system me secondary loop me zyada GPM building ko delivered krta hai maximum cases me...agar aap kisi v site pe jao waha dekhna building ka load zyada hoga to secondary pump ka flow rate primary se zyada hota hai to is case me building ko v zyada GMP chahiye hota hai kyu k bhut sare AHU hote hai..to us case me thoda paani bypass hota hai.... decoupler line pe automatic valve nahi lagate hai pani ka flow pump k pressure drop k according hota hai

    • @AshrafKhan-xu4wk
      @AshrafKhan-xu4wk Před 4 lety +1

      @@HVACWorld sir chiller opreating kaise karte h bata dijiye step by step

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Video mil jayegi apko....I hope apka doubt clear ho gaya hoga.... primary pump ka pura paani decoupler se suck nhi krega kyu k secondary pump v running condition me hai to wo v paani suck krega or aage building me bhejega... decoupler is chiz ko mind me rakh kr kiya jata hai uske bich ka pressure drop is trh se design kiya jata h k pura paani wapis se primary pump me na aye....

    • @AshrafKhan-xu4wk
      @AshrafKhan-xu4wk Před 4 lety +1

      @@HVACWorld sir doubt clear ho gaya

    • @HVACWorld
      @HVACWorld  Před 4 lety

      Thanks

  • @thepurposeofmyexistence2511

    Dear sir, i could not get one point , why allways we put the 2way valve or picv valve on the outlet of the ahu or fcu , can we put it on inlet of fcu/ ahu , and put actuator which operate on temp sensor of return air , if room temp achived then it will close the supply valve to fcu , which is same as if we put picv down stream the fcu

  • @jai.shree.Ram-sena108
    @jai.shree.Ram-sena108 Před 3 měsíci

    Primary pumb kaha laga hota hai aur secdary pumb plz answer

  • @mdsadabalam9434
    @mdsadabalam9434 Před 3 lety +1

    Sir DPT return ka pressure kaise sense karta hai wo to supply me laga hai

    • @HVACWorld
      @HVACWorld  Před 3 lety

      I will explain you in video

    • @mdsadabalam9434
      @mdsadabalam9434 Před 3 lety +1

      Thanks sir Actually,My course is about to finish on 30August,If you can explain before 30 August I will be grateful for you.Thanks

    • @HVACWorld
      @HVACWorld  Před 3 lety

      30 August se pahle video mil jayegi with practical demonstration

    • @mdsadabalam9434
      @mdsadabalam9434 Před 3 lety +1

      Thanks sir❤️

  • @masterchef6694
    @masterchef6694 Před 2 lety

    Can we have 2 sets (arrays) of pumps in the secondary side? (If there are 2 different types of loads with very different pressure drops)

  • @mdwaquaruddin165
    @mdwaquaruddin165 Před rokem

    In vpf system where the water goes when system is return at part load

  • @mdsuhailansari485
    @mdsuhailansari485 Před 2 lety +1

    600 tr ka ek hi chiller ho sakta hai kya?

  • @MANISHYADAV-kc7jm
    @MANISHYADAV-kc7jm Před 4 lety

    ye balancing valve Q lga rhe hai two way valve ke baad .iska kya opration hai

  • @DilshadAhmad-mw3yc
    @DilshadAhmad-mw3yc Před 3 lety +1

    Sir ji vfd se load kam kyu ho raha hai
    Pahle 100 % me chal raha tha abhi 40% me chal raha hai kyu

    • @HVACWorld
      @HVACWorld  Před 3 lety

      100% kab to or 40% kab hua???

  • @tinkurajrajsingh8589
    @tinkurajrajsingh8589 Před 3 měsíci +1

    Sir ji mujhe HVAC se koi diploma karna hai kon sa karu

    • @HVACWorld
      @HVACWorld  Před 3 měsíci

      HVAC in diploma nahi hota hai.... Diploma in Refrigeration and air conditioning se hota hai

  • @RahulKumar-yy2jg
    @RahulKumar-yy2jg Před 3 lety +1

    K3 metalizer kae bar me kuchh batai sir ji apana number dijiye

  • @mohammadrahman7597
    @mohammadrahman7597 Před 2 měsíci

    Is it possible to get a ladder diagram

  • @ArifKhan-nh8xd
    @ArifKhan-nh8xd Před rokem

    Sir can you explain me how we calculate GPM

  • @dilawarkhan4838
    @dilawarkhan4838 Před rokem

    Bhai to is system Mai bypass open hi rkhna hota hai

  • @chiragbari7680
    @chiragbari7680 Před 3 lety

    Need to primary and secondary pump commissioning video upload (Mumbai)

  • @DilshadAhmad-mw3yc
    @DilshadAhmad-mw3yc Před 3 lety +1

    Hello sir

  • @9889008366
    @9889008366 Před 3 lety

    Confusing.

  • @johnphilip7084
    @johnphilip7084 Před rokem +1

    dps be placed in which line as there is both supply and return line,for example 6floor building which floor it be placed.can i have ur mail id i have some doubt to learn can u help me out.

    • @HVACWorld
      @HVACWorld  Před rokem +1

      If 6th floor is your furthest point, Install it on 6th floor

    • @HVACWorld
      @HVACWorld  Před rokem

      *5th floor

    • @johnphilip7084
      @johnphilip7084 Před rokem

      @@HVACWorld dps is placed in which line as there is 2 lines supply and return

  • @Kaishar-Raza
    @Kaishar-Raza Před 2 dny

    TFA me kb se CHW water jane lga 😂

  • @usmankhalid1806
    @usmankhalid1806 Před 3 lety

    Please explain.. lot of respects Stay blessed
    Sir i want your email id please if you feel easy. Because your channel have made my interest in HVAC.

  • @mepmep5682
    @mepmep5682 Před 2 lety +1

    100 TR ka AHU 😂

  • @dil_ipkumar
    @dil_ipkumar Před 2 lety

    Bhai VFD Hota hai VSD Nahi to hai yaar correction kijiye pahle vedio ko

    • @trick-tech6623
      @trick-tech6623 Před 2 měsíci +1

      Vfd means variable frequency drive
      Vsd means variable speed drive.
      Bro plz enhance your knowledge before blaming someone.

    • @HVACWorld
      @HVACWorld  Před 2 měsíci

      @trick-tech6623 zyada gyani ban jate ho. VFD or VSD k bare me ye video nahi h....ye Video piping system k bare me jisme pump ki speed vary karti h. Speed vary karne k liye VFD or VSD dono ka use Kiya jata h kyu dono ka kaam ek hi hai. Agar VFD k bare me janna hai to dusri video dekh lo.

  • @a.m347
    @a.m347 Před rokem

    English please 😢

  • @usmankhalid1806
    @usmankhalid1806 Před 3 lety

    And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?