End Termination of 33KV 3CX120SQMM HT Cable,

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • 5 Must-Have Tools for Efficient and Effective Cable Jointing
    As a cable jointer, you are responsible for ensuring the safe and efficient connection of cables in various electrical systems. To perform your job effectively, it is important to have the right tools and equipment at your disposal. Here are 5 essential tools every cable jointer should have in their toolkit.
    Cable Stripper: A high-quality cable stripper is a must-have tool for cable jointing. This tool helps you to remove the outer insulation of a cable, allowing you to prepare it for jointing. It should have adjustable blades to accommodate different cable sizes, and be made of durable materials to ensure a long lifespan.
    Cable Cutter: Cable cutters are another essential tool for cable jointing. They are used to cut the cable to the correct length, and should be designed to cut through the outer insulation and inner conductors without damaging them. Look for a cutter that is comfortable to use and has a cutting edge that stays sharp.
    Heat Gun: A heat gun is a crucial tool for cable jointing, especially for heat shrink cable joints. The heat gun is used to activate the heat shrink tubing, causing it to shrink and form a tight seal around the joint. It should be powerful enough to heat the heat shrink tubing evenly, and have a temperature control to prevent overheating.
    Cable Jointing Compounds: Cable jointing compounds are used to fill any gaps in the cable joint, ensuring a strong and durable connection. Look for a compound that is easy to apply, and provides good insulation and protection from moisture and environmental elements.
    Measuring Tape: A measuring tape is a simple, but essential tool for cable jointing. It is used to measure the length of the cable, and to ensure that the cable is cut to the correct length before jointing. Look for a measuring tape that is durable and easy to read, with a locking mechanism to hold the measurement in place.
    Having these 5 essential tools in your toolkit will ensure that you have everything you need to perform cable jointing efficiently and effectively. Remember to always use the proper techniques and follow all safety protocols to ensure the safety of yourself and those around you
    End Termination of 33KV 3CX120SQMM HT Cable, HT Cable Termination, Jointer Training, Termination kit kaise bharna hai, HV cable Termination kaise kerna hai, HT Cable joint kit
    #ht cable Termination #cable Termination Work #electrical joints and connections
    cable Termination interview questions
    cable Termination tools

Komentáře • 41

  • @alajingisivakumar5592
    @alajingisivakumar5592 Před měsícem +2

    Thank u bhayya.
    Raju bhayya also a brilliant worker.

  • @MuhammadMuzammal-eg6tl
    @MuhammadMuzammal-eg6tl Před 4 dny +1

    great work

    • @AkramAnsari.678
      @AkramAnsari.678  Před 4 dny

      Glad you enjoyed
      Keep watching and supporting my channel

  • @jamilusmani-m3x
    @jamilusmani-m3x Před 5 dny +1

    Great sir thanks so much

    • @AkramAnsari.678
      @AkramAnsari.678  Před 5 dny

      @@jamilusmani-m3x glad you enjoyed
      Keep watching and supporting my channel

  • @rkcreation7155
    @rkcreation7155 Před měsícem +1

    ❤❤❤

  • @pannierselvamsanthoshkumar8958

    Good video i will like it

    • @AkramAnsari.678
      @AkramAnsari.678  Před měsícem

      @@pannierselvamsanthoshkumar8958 glad you enjoyed
      Visit other videos, I am sure you will like those too

  • @RahulSahu-zu1eb
    @RahulSahu-zu1eb Před 8 měsíci +2

    Very nice video sir 💯💯

  • @bishuroy6146
    @bishuroy6146 Před 8 měsíci +1

    It's helpfull details for termination

  • @rustemmemmedov7134
    @rustemmemmedov7134 Před 4 měsíci +1

    There are special tools for stripping the semi-conductive layer, if you work with it, your work will be both fast and high-quality, and there is no need for additional polishing. The sharp edges at the end of the semi-conductor are counterintuitive and one of the reasons for the coupling to fail.

    • @AkramAnsari.678
      @AkramAnsari.678  Před 3 měsíci

      Agreed
      Many Joint makers don't have proper tool kits required to to make joints due to economic issues and rate of joints so these videos are those who are working with available tools with them and can make a proper joint with these tools

  • @RahulSahu-zu1eb
    @RahulSahu-zu1eb Před 8 měsíci +2

    Amazing

  • @Somlal
    @Somlal Před 14 dny +1

    Insulation semi conductor screen removal is totally wrong, could end up damaging the insulation, use depth knife instead.

    • @AkramAnsari.678
      @AkramAnsari.678  Před 14 dny

      @@Somlal I appreciate your concern and also want to share my experience that it is always better to use proper tool to specific job.
      But it doesn't mean this is wrong practice, I have been seeing the same method in practice all over India and no failure found so far

  • @user-cq9jo4mr3q
    @user-cq9jo4mr3q Před 7 měsíci +1

    सर केबल testing ka भी वीडियो बनाए साथ में ही VLF testing of cable

    • @AkramAnsari.678
      @AkramAnsari.678  Před 7 měsíci +1

      Thanks for your interest, I will upload these Videos asap

    • @user-cq9jo4mr3q
      @user-cq9jo4mr3q Před 7 měsíci

      @@AkramAnsari.678 thanks sir ji, cable laying और pulling का भी वीडियो प्लीज़ सर जी

  • @gopinathsutradhar5446
    @gopinathsutradhar5446 Před 7 měsíci +1

    Very nice

  • @rahulagarwal8213
    @rahulagarwal8213 Před 7 měsíci +1

    Isme cable ka konsa wala Core R, Y, B phase jayega , ye kaise pata chalta hai ? Ya koi sa bhi connect kar sakte hai ??

    • @AkramAnsari.678
      @AkramAnsari.678  Před 7 měsíci

      First of all, we make the end termination of anyone at the end of cable as per equipment R,Y,B nomenclature thereafter with reference to equipment R,Y,B phase sequence we check and mark the same R,Y,B at the other end of the cable.
      Now, we have to ensure that what we marked R,Y,B phase sequence at second end of cable, it should be matched with the equipment phase sequence while making second end termination.

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 Před 3 měsíci +1

    No English subtitle or version??

  • @bishuroy6146
    @bishuroy6146 Před 8 měsíci +1

    Cell pack ka training keise milega sir g

  • @CHANDTARA9006
    @CHANDTARA9006 Před 3 měsíci +1

    🎉🎉🎉

  • @AkramAnsari.678
    @AkramAnsari.678  Před 8 měsíci +1

    I'll let you know asap

    • @bishuroy6146
      @bishuroy6146 Před 8 měsíci

      Sir, i am 3m certified jointer, how to get cellpack training?

  • @Mr.Sandeep413
    @Mr.Sandeep413 Před 2 měsíci

    Ye koi experience holder nahi hai bz jo earthing kar rha usko hmsha scratch karke lgana chahiye jo proper earth pakde

    • @AkramAnsari.678
      @AkramAnsari.678  Před 2 měsíci

      Thanks for your valuable feedback, but it depends on the make of the jointing kits.
      For this we cannot say anyone he is not experienced

  • @gollugowrinaidu6541
    @gollugowrinaidu6541 Před 7 měsíci +1

    Which company kit

  • @AjayKumar-uq8vq
    @AjayKumar-uq8vq Před 6 měsíci +1

    Banda may kaha par plant h sir aur kitna MW ka h sir plant

  • @zaitonyahya4768
    @zaitonyahya4768 Před 2 měsíci +1

    102

  • @AkramAnsari.678
    @AkramAnsari.678  Před 2 měsíci

    My latest video on major equipment of switchyard and MCR in solar power plant
    czcams.com/video/a07BQZFEHh4/video.htmlsi=g1fuc7y-Q7dh3kPh