Video není dostupné.
Omlouváme se.

Pressure pump fitting | Automatic pressure pump | Washing machine pressure | Shower pressure

Sdílet
Vložit
  • čas přidán 24. 10. 2022
  • Know how to fit Pressure pump for washing machine or Shower.
    Sequential procedure is shown in this video, to fit Pump easily.
    Here is the link for V guard automatic pressure pump:
    amzn.eu/d/iRblLBG
    Link for fixing washing machine or fridge on adjustable trolley / Stand :
    • Fix washing machine on...
    Approximate expenses for Pump fittings:
    1) Pressure Pump cost : 4500 INR
    2) Piping fittings : 1500 INR
    3) Plumber : 500 INR
    4) Electrical fittings : 600 INR
    5) Electrician : 500 INR
    Total Cost is around 7600 INR.

Komentáře • 114

  • @Quote07
    @Quote07 Před 9 měsíci +4

    Thanks for your information, I spent @RS 4500 /- total cost. @RS 2500/- for a Pressure Pump ,@RS1000/- for Electrican and plumber and Approx @Rs 1000/- for Fitting material.

  • @siddharthpathare2
    @siddharthpathare2 Před 11 měsíci

    ekadam mast explanation, kjup changali mahiti milali.

  • @jacobfamilyyoutubechannel2937

    I like your output piping. Good use of a single motor for at least two outputs

  • @rajeshv8257
    @rajeshv8257 Před rokem +1

    Thanks, Sir, for giving me good information.

  • @GoofyPandit
    @GoofyPandit Před rokem +2

    Thanks for the info!

  • @1108ankur
    @1108ankur Před rokem +4

    Thanks , useful info, how long u r using this pump..
    Just wanted to confirm on pump positioning, as per instruction it should be horizontal not vertical, but as per space vertical is more suitable so if it’s working fine for long duration than it’s fine.

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      I am using it from last 1 month.
      You are correct. motor shaft shall be horizontal as per manual drawings. I have kept pump in wrong way, to remove maximum water from syntex. That is to reduce dead volume of Syntex tank.
      If you can install pump below bottom line of Syntex, then you can keep pump with horizontal shaft position ( 3 correct positions given in manual). Also you can remove max holdup of Syntex.

    • @deepakk1347
      @deepakk1347 Před rokem

      @@deepakkhilari7415 sir what is syntex?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Sorry spelling mistake. It's sintex tank. That is white tank shown in video

  • @kedarjoshi9255
    @kedarjoshi9255 Před rokem +1

    Bitha hai ya nahi on your screen first got message never install pressure pump for wm

  • @bapusohonmane2159
    @bapusohonmane2159 Před 8 dny

    What's price of pressure pump

  • @AdityaGuptaX
    @AdityaGuptaX Před 4 měsíci

    Can water flow reverse when the motor is switched off to fill the tank from other source?

  • @NarendraKothariCA
    @NarendraKothariCA Před rokem +1

    Can the same pump be used to get pressure in shover ?
    Means can I install it after geyser

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Do you need hot water in shower ? If yes then no need to install pump after geyser.
      You can install pump at bottom of water storage/Syntex tank. This will pump water to shower via geyser. But for more flowrate of 30 LPM, you will not get very hot water.

    • @yashenterprises177
      @yashenterprises177 Před rokem

      Geyser Inlet if fixed on Pressure Pump outlet the problem is solved -- The pump is than pussing Cold water to Geyser resulting in enhanced pressure fro Hot water outlet in Geyser. The pressure pump can route the hot water also -- But the Aforementioned techniques enhances the life of PPump.
      Rgds

  • @mudassarbhatkar8386
    @mudassarbhatkar8386 Před rokem +1

    Very good and informative video

  • @abir95571
    @abir95571 Před rokem +1

    Hi i connected water booster pump’s outlet to my washing machine and the machine doesn’t seem to auto start. However when test it disconnecting to the machine, it works fine. What could be the reason?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Please watch complete video. Suction piping shall be similar to video to work pump in auto mode..
      There shall be gravity flow from line/pump to start pump in auto mode.
      Syntex tank and water pump shall be above washing machine as like video.

    • @nitinsahu5789
      @nitinsahu5789 Před 6 měsíci

      ​@@deepakkhilari7415 in my case the tank is smiliar to pump but still not working

  • @91prashu
    @91prashu Před rokem +3

    Hi , I live in an apartment where pressure is always maintained but water has a high salt content. I have a counter top dishwasher but due to high salt content scaling appears badly. I have planned to install a plastic tank (50L )beneath the dishwasher. I'll connect my R.O to the tank. If I run R.O say 4-5 hours then the tank will be filled with clean water. Till this step I have no doubt. If I connect the pressure pump from clean water tank ( located under ) to the dishwasher inlet and set it up in auto mode will this arrangement work. My intention is to supply clean water to the dishwasher. Dishwasher typical consumption per cycle is 10 L max .

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      Hello. I am assuming that Dishwasher bottom and 50 L plastic tank bottom is at same level. Pressure Pump suction is connected to 50 L plastic tank and discharge is connected to Dishwasher. Pressure Pump inlet and outlet line size is 1".
      With above arrangement you will get pressure around 1 kg/cm2 gauge and 24 lit per minute flowrate. I think it will work and satisfy your requirement.
      Elevation of "50 L plastic tank with pump" can be above Dishwasher.
      But do not install "50 L plastic tank with pump" below elevation of Dishwasher. It will reduce pressure.

    • @91prashu
      @91prashu Před rokem +1

      @@deepakkhilari7415 50 L tank will be placed below the counter i.e below dishwasher because 1. I have no loft
      2. Even If I fabricate a stand and place the tank above dish washer I will not be able to pump the R.O water to the tank. Any other alternative?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      @Prashanth ji, 1 to 1.5 meter height difference between pump and Dishwasher is acceptable.
      That is pump is at floor and Dishwasher is above 1 meter.

    • @91prashu
      @91prashu Před rokem +1

      @@deepakkhilari7415 Thankyou very much for guiding me.

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Thank you for appreciation.

  • @spotoncam3640
    @spotoncam3640 Před 2 měsíci

    मेरा यहि पंप है पर बॉश् प् फ्रन्ट लोड मशीन पानी लेना शुरू करें तो ये पंप ऑन नही होता !
    पैनासोनिक का टॉप लोड मशीन में यह पंप ऑन हो जाता था 😂

  • @mitsunamsa6650
    @mitsunamsa6650 Před rokem +1

    Hello please reply... I bought Bosch dishwasher and done the same setting ( in comment section Mr Prashant put a query)but my setup doesn't work. I bought lubi pump and set the tank of 35 litre above pump with 1 bar pressure approx hight 3 feet.. and now i bkm panic and searching solution on net and I found this comment.. please help me to get rid of it

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      Ok. I am not getting clear idea. Can you send pictures of your pump, tank , washer setup.
      deepak.r.khilari@gmail.com

  • @user-lh3pr6dl6m
    @user-lh3pr6dl6m Před rokem +1

    is preasure pump lagene se keya gyser ki jo hot water ki speed obhi barenge or uski liye alag preasure pump lagane parega?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      geyser se pani aa raha he usaki speed badh jayega. Lekin jyada speed ki wajah je pani ka temperature pahile ke mukabale kam hoga (pump lagane se pahile).

    • @user-lh3pr6dl6m
      @user-lh3pr6dl6m Před rokem +1

      thank you Depak Vai.

  • @BhagyashreeBorkar
    @BhagyashreeBorkar Před rokem +1

    Hello sir
    Maine same pump mere dishwasher ko lagaya hai par wo auto pe kaam nahi karata manual rakhana padata hai .. kuch idea hai kya pls batana

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Pl watch complete video.
      Suction line video jaise karo. Syntex tank and pump, dish washer ke upar hona chahiye. Pump ko bypass mat dena
      Line/pump se gravity flow hona chahiye tabhi pump auto start hoga

  • @varunsharma7852
    @varunsharma7852 Před rokem +1

    Bhaiyaa, isse off on kese krna, matalb hr time on rahta ya, jb use krna ho har bar upr jake on krna,.. Ye clear kr dijiye
    Aur jb light nai hogi, to phir pressure pahle se bi kn nina ho jayega

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Auto me rakhna. To har time on off karna jaruri nhi. Pani ka use nhi hoga to automatically band hoga. Pani ka use karoge to automatically start hoga.
      Light nahi rahegi ya fir pump switch band karoge to pani ka normal flow hoga by gravity

    • @varunsharma7852
      @varunsharma7852 Před 10 měsíci

      ​@@deepakkhilari7415 inverter se connection de skte hai...
      Inverter par load kitna dalegi..?

  • @feddythechamp
    @feddythechamp Před rokem +1

    I had installed dsk 0.5 pressure motor 4yrs ago. But recently there is a water leakage occurred from the motor near the outlet point. How can we fix it?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      Ok. Please check leakage from pump or piping. Damage of Pump gasket can cause leakage from pump.

    • @feddythechamp
      @feddythechamp Před rokem

      @@deepakkhilari7415 Plumber told there is a internal leakage from the pump. Plumber don't know to repair the pump. Who repairs such pumps?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      @@feddythechamp contact manufacturer's customer care number.

  • @IRS_magnetar
    @IRS_magnetar Před rokem +1

    Hi Deepak Thanks for the Video Mate !! I am facing pressure issue in the shower and Toilet flush(no tank flush valve) The vertical height between the tank and shower is 4-5 feet only. Can this VGuard little pump of 0.18hp solve this problem. Or do i need to buy a 0.5hp bigger pump. I read in reviews that this small pump doesnt deliver enough pressure for shower & Toilet & the 0.5hp pump is a bit expensive and might also cause leakage issues in the connections because if higher pressure. Will appreciate your suggestion.

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +2

      Yes. 0.18 kw pump is ok for 5ft height.
      That is shower is 5ft above tank. You will get around 1m3/hr flow for 5ft height.
      If your tank is 5ft above shower then you will get 1.8 m3/hr flow

    • @IRS_magnetar
      @IRS_magnetar Před rokem

      @@deepakkhilari7415 thank you !!

  • @starlights214
    @starlights214 Před rokem +1

    How about the noise? Is it noisy?

  • @deepaksonu1785
    @deepaksonu1785 Před rokem +1

    I have Bosch washing machine. It's display shows low water pressure tap symbol but clothes are washed very well. Just it takes 10 mins more than its usual time. I think low pressure will not affect washing machine. Am I correct Brother

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      For front load washing machine, Pressure is required. Lower pressure can cause water valve failure.
      If your machine is working then Pump is not required.
      Is your machine front load?
      What is the approx height difference between tank/ Syntex to washing machine?

    • @deepaksonu1785
      @deepaksonu1785 Před rokem

      @@deepakkhilari7415 yes mine is front load washing machine. May be 15feet height. Washing machine working properly without interruption but taking 10 to 15 mins more time than usual

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      @@deepaksonu1785 ji , machin is working fine then no need to invest in pump.

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem +1

      @@deepaksonu1785 for 15 ft height difference you are getting around 0.5 kg/cm2g (7 psig) pressure ) that is enough..

    • @deepaksonu1785
      @deepaksonu1785 Před rokem

      @@deepakkhilari7415 thanks for the valuable information 🤝🤝

  • @VijayKumar-nr7cr
    @VijayKumar-nr7cr Před 10 měsíci

    I have no sintex but i want to buy washing machine so what can i do for water pumping. ...
    Ground

    • @deepakkhilari7415
      @deepakkhilari7415  Před 9 měsíci

      If possible install sintex tank 5m above machine. Pressure pump for washing machine will not required.

  • @RAJESHNAIK-jb9jk
    @RAJESHNAIK-jb9jk Před 2 měsíci

    Please read the instructions on pump, pump shaft should be horizontal not vertical

  • @dileswarsahu9125
    @dileswarsahu9125 Před 10 měsíci

    Can it be work in fully automatic front load washing?
    Or what means automatic mode in motor can it be operated automatically while my washing machine is on ?

    • @deepakkhilari7415
      @deepakkhilari7415  Před 9 měsíci

      Automatic pump starts only when you consume water for washing machine or shower or tap.
      Once you stop consumption, pump will stop

    • @dileswarsahu9125
      @dileswarsahu9125 Před 9 měsíci

      After seeing your video I will install this same motor normally it’s works fine like when I on the tap the motor will be start automatically and stop after off the tape but in case of fully automatic washing machine it’s not working properly

  • @parshwajain3086
    @parshwajain3086 Před rokem +1

    Sir v gaurd ka aacha h ya fir BTALI ..plz reply

  • @musidiction8666
    @musidiction8666 Před rokem

    Sir i have a query....
    I have top load Samsung Washing machine. But the tank is merely 4 ft above the ground and on that same floor i have installed the washing machine. So i dont get the appropriate pressure. Will this motor can solve my problem ?

  • @BholaKumar-sy5pb
    @BholaKumar-sy5pb Před rokem +1

    Kya yah niche se Pani khich sakta hai

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Khichega. Niche 5 meter se height jyada na ho. Foot valve acha hona chahiye.
      Niche se Pani khichane ke time ye auto me kam nhi karega. Manual me karna padega.

  • @seeingahead
    @seeingahead Před 9 měsíci

    Auto sensor ke flow switch ka on and off threshold kya hai? Yeh setup kiya hai maine par washing machine and dish washer ke flow rates pe auto start nahi hota har baar.

    • @nitinsahu5789
      @nitinsahu5789 Před 6 měsíci

      Yes aapne kaise solve kiya ye issue

    • @seeingahead
      @seeingahead Před 6 měsíci

      ek pipe aur valve tank mein back flow ke daal diya - jabhi washing machine chalata hun tabhi motor bhi on aur valve half open kar deta hun (motor on auto mode always)
      Aur pipe diameter 0.5 se 0.75 kar diya jisse dishwasher bina motor ke chal jata hai
      @@nitinsahu5789

    • @say2000in
      @say2000in Před 5 měsíci

      Same issue for me

  • @sukantbarua144
    @sukantbarua144 Před 7 měsíci

    Kitana hp ka hai sir ?

  • @maharastramaza5577
    @maharastramaza5577 Před rokem +1

    Sahi hai sir

  • @battleongaming4223
    @battleongaming4223 Před rokem

    I want to buy it for my washing machine
    The tank is on ground level as well as washing machine is on ground level
    Will this pump satisfy my requirement.. ?

    • @deepakkhilari7415
      @deepakkhilari7415  Před rokem

      Pump will work in manual mode only in ur case.
      There shall be gravity flow from line/pump to start pump in auto mode . That is possible in my case shown in video.
      To have gravity flow from line and pump , Syntex tank and pump shall be above washing machine.

  • @kanchankhilari930
    @kanchankhilari930 Před rokem +1

    Thanks for useful information...keep it up 💯👍👍👍

  • @AKMahadev-cg3fc
    @AKMahadev-cg3fc Před 11 měsíci

    Gav konta apla

  • @facts2grow888
    @facts2grow888 Před rokem

    20 A switch algse lagana pdega Kya?

  • @hardikdhanani4522
    @hardikdhanani4522 Před rokem +1

    Sir v.guard pressure pump price ???

  • @AKMahadev-cg3fc
    @AKMahadev-cg3fc Před 10 měsíci

    Washing machine ka line itna uper se kyu liya niche se sidha kyun nahi liya

  • @tatyasahebbhosale2350
    @tatyasahebbhosale2350 Před 10 měsíci

    1.48 wrong pump installation
    Check user manual

  • @hussainsk2665
    @hussainsk2665 Před rokem

    Kha milega bhai, price

  • @justintrudeau75
    @justintrudeau75 Před rokem

    Hello sir thank you so much for making video as i was finding such videos. Yesterday i install the same motor but i am not satisfied with the pressure as i can only see minimal difference as if i want to explain u in simple words i live in apartment where we usually gets water at morning 8 and evening 8 so. The pressure which is get at that time i was expecting same but when installed the pump i am not getting that pressure as when the machine is off the pressure which get is only 2-3% difference when the motor is on . If you sir don't mind can please get ur Instagram id or something where i can i cannot with you and share you the video please. I installed this motor on 26 July and i am commenting on 27 July night that is 01:27 hrs

  • @kishorvartak3819
    @kishorvartak3819 Před rokem

    भाई साहब आपका सर्विस मुंबई वेस्टनमें कहाँसे कहाँतक है.आपका काँट्याक नंबर प्लीज.

  • @drswapnilprabhulkar6183

    यह पंप भी ठीक से काम नहीं करता है।

  • @johndoe-vc1we
    @johndoe-vc1we Před rokem

    Thumbs down for the clickbait thumbnail👎

  • @bharatacharya2556
    @bharatacharya2556 Před rokem

    share your mobile no. we need to install for washing machine