Nice video my friend , A very creative idea ///////////❤❤❤❤❤❤
(150)2 واٹ کے پینل اور 585واٹ کے پینل کو اکٹھا لگا سکتے ہیں ...اگر لگا سکتے ہیں تو چارجر کونسا MPPT یاpwp...لگانا چاہیے یا نہیں ۔۔۔۔پہلے 2پینل 150موجود ہیں اب ایک 585لینا چاہتا ہوں ۔۔۔بیٹری 100Amp کی موجود ہے۔۔DC 12وولٹ چلانا ہے۔۔پلیز گائیڈ لازمی کر دیں۔
ni laga skty kbhi bhi
Bhai behtar tu yeh hy keh ap 585 ke plate aur mppt le len es sy ap sar load chly ga 150 ke sath na lagain
Very nice
Assalamualaikum
Bhai ye bataye maloom kar ke 10,000 /- ka kon sa MPPT 60A ka mil jaey ga ,uss ki video bhi banaen.....kyu ke har koi MPPT mehga hi sell kar raha hai sastaa koi nahi sell kar raha haii ,,solar panel ke paise nichaay aa rahe hain lakin MPPT ke rate din ba din bartey ja rahe hain..jo lacal MPPT ban rahe hain jo "Brand"bhi nahi hain wo bhii mehgey sell kar rahe hain sab mil kar bewqoof bana rahe hain logo ko..
Prince hy jo pehly 8800 ka thaa ab woh bhe 10000 se upr de rahe hn yahe tu mafia hy jo gerebon ko lota hy
Mn ne is k sath 1 inverter lgaya howa ha fridge chalny k liye .jab inverter off hota ha to battery ko 14.2 sy charge krta ha lkn jab inverter on krta hu to voltage 15.6 tak chly jaty hn .3 mint chlny k bad volt 12.5 pr aa jaty hn or amp 000 pr phr automatic dobara 15.8 volt or 56 amp tak chly jaty hn.ye kia msla ha
same issue hai mere pass sir.load chalao to 15.2 chala jata hai wese 14.2 hi rehta hai
Bhai Battery ke aik dfa Gravity chek kra len
Battery new install ki masla sir tab aata jab main fridge on karta hoon ups hai 1500 watt ka fridge to aram se chalta hai lekin voltage phir badh jate hain wese thek hote hain normal load pe
sir iskay current kaisay kam karay
2 soler panel lagae hai 580 watt k
battery ko 25 amp par charge kar raha hai 6mm wire mppt to battery bohot zyada garam ho jata hai
battery 150 amph hai please replay zaror daina
parallel aur series dono mein check kia hai eik he masala hai
Es ka vereable batan 50 v tk kam krta hy ap ne 2 panal lagi hn ap 1 panal lagain main bhe cnadian 575 1 lgia hy
Jab ap nay load on kia to battery wali light ku blink krny lgi? Matlb agar apki battery full charge ho to kia load direct mppt othaye ga ya battery sy?
Bahi jab Betry full Hoti ha or jab hum extra lod on karty hain to yeh light on ho jati ha or yeh sham k time asy Hota ha din ko nai.din ko Betry full rehti ha
AoA...plz let me know how you are converting DC to AC mean invertor...which invertor is used for this? Kindly share... JazakAllah
For long backup I am use only Dc home employees. You can use ups Dc to Ac converter in low budget
agr amp 0 show hon to isko kese set krynm?
sir s mppt k hybrid model ke hybrid settings ka bata dain k kaise hote hai plz bcz mere pas yahi wala hybrid model ha din k time solar peak pe hota ha but wapda ko use kr rha hota ha
Ap koshish kren keh din ko wapda off kr den keunkeh yeh peak time m bhe wapda sharing krty rehty hn even kuch Inverter bhe maslan farounis wagera
Mera pas same mppt lga hoa ha lkn us ma aik problem a rha ha. Ma na 4 plates 180 watt ki lgai hoi hain jab un 4 plates ko series ma lgata ho to mppt ka amp meter sae work krta ha lkn jab plates ka 2+2 ka pair bna kr lagta ho to mppt ka amp meter off ho jta ha kya ap bta skta hain kya problem ha
2/2 se Ampair tu brh jaty hn lekan voltage km ho jaty hn es ly problem krta hy
Salam sir mery yahi laga huwa h paktech ka mppt jb solar se amp aty hn to wo 80 tak chaly jaty hn..
Battery k sath ups lga huwa h us par srf ik computer r dc fan chalta hy...
Amp 80 tk chaly haty hn r volt 15.5 tk..
Solar ka connection parallel hy...
Ye kia issue hoga amp ka... ?
Kindly bta den ap k jwab ka muntazir...
Ap solar sareez m lagin
Battry full charge cutt off 14.8 pe set hen. Float charging ka matlab bhi yehi hota ha? Plz reply.
Ap cutoff voltage 13.8 ya 9 pe rken battery long-time chle ge
@@ZAEngineeringhub-Zulfiqar mere pas deep cycle battery ha 145ah
Battery voltage ko 14 per set karo warna battery boht jald kharab ho jay gi
Bhai mere pass 585 k 2 penal hai 190bettery hai main ne wo wo bton pe gor ni kia 12v or 24v pe main 24v pe chala raha hu ab 12v pe kr du baton ko plZ bta dain
G ap 12 pr kr deen 24 pr tu mppt ke Battery full wale light he on ne hote lgatar charging hote rehty hy battery ke blast hone ka khatra hy
Bhai solar ki cables series me lagani hain ya parallel?
Saries
Jo motor Ap ne chalay h. Wo Ac h ya Dc
Dc
Bhi mery pass same is tarha ka h 70 amper ka vintech ka .....kya is ki koi setting b karni parti h
Cutoff Voltage kam rakhen ge tu Battery ke life zeada ho ge
Agar battery full Kar data ha time pay to na charain eski agr Sahi chal raha ha to
Mara bi pk teac mppt charge controller ha wo battery full b ho to 16/17 ampare use kr rha hota ha load k bagar please solution
Aik tu cutoff voltage km kren 13.7 dusra battery ko chek kren
@@ZAEngineeringhub-Zulfiqar bhi mein nay parrael connection kea ha ab cut off volt 13.1 ha series mein 14.5 hota tha 13.1 mein b battery theek charge ho ge 🥱🥱 jb battery 13 pr jatie ha ampare 0 show hoty ha
Can I call u for mppt settings
جزاك الله
load chalane par 15.2 battery voltage pe chali jati hai wese 14.2 hi rehta hai keya ye thek hai
Jo load ap chla rahy hn kahe woh 15.2 A ka na ho dosra ap Ampair mppt chek krty hn ya kse mtr wagera se
Bhai mene paktech mppt py 14.2 cut off set ki hai phir bhi wo 14.2 sy opar chala jata hai 15volts tak asa Q? please reply
Ap vereable screw ko Clockwise ghumain 13.7 pe tu m ne set kia hy aik bhai ka
Same issue
کوئی بھائی میرے سوال کا اگر کنفرم جواب دے سکتا ہے تو پلیز زحمت فرمائیں
یہ تو کنفرم ہے میں بھی جانتا ہوں کہ چارج کنٹرولر کے ساتھ پہلے بیٹری کو لگایا جاتا ہے بعد میں سولر
لیکن میرے پاس فیصل 65 ایمپئر کا چارج کنٹرولر ہے جس سے لیا ہے اس نے اور ایک دو اور بندوں نے کہا کہ فیصل والوں کا کنکشن الٹ ہوتا ہے یعنی پہلے سولر کو کنکٹ کریں'گے بعد میں بیٹری کو اور اس نے چیکنک کے دوران ایسا ہی کیا
لیکن میں کنفیوز ہوں ایسا کرنا واقعی ٹھیک ہو گا؟؟
اور اگر ہم پہلے بیٹری کو کنکٹ کریں'گے تو کٹ آ ف وولٹیج کو کس طرح سیٹ کریں گے پھر ؟
کوئ ٹیکنیکل یا تجربہ کار بندہ پلیز رہنمائی کریں
Ap solar ke tareen pehly lga cutoff voltage set kr skty hn no problem main ne paktech mppt ka esy he conviction kia hy
Clenp miter sy check kery
aap ne MPPT k saath PWM q Lagaya hai ? sirf MPPT se kaam nahin chalay ga ?
Pwm ke sath 2 180w ke panal lgy hn jo keh pehly kharedy hove thee
Two betray series my ya perlal my lagygy.
Age 12 V bnany Hain tho parallel. Awr agr 24 V bnany hain tho Series main
Parlar agr ups ya Dc home Appliance 12 hn tu.
Parallel ka Kya faida ha? Ma ne 2 panel 580w k series me lgae hen. Mppt 80a ha. Plz guide kr dein@@ZAEngineeringhub-Zulfiqar
@@birdlovers9182
بیٹریاں پیرالیل میں جوڑنے سے ان کا کرنٹ اور کیپیسٹی (یعنی چارج سٹور کرنے کی گنجائش) دونوں بڑھ جاتے ہیں مگر وولٹیج نہیں بدلتے۔ مثلا اگر آپ کے پاس 2 بیٹریاں ہیں اور ہر بیٹری کے وولٹیج 12V، کیپیسٹی 120Ah، اور چارجنگ یا ڈسچارجنگ کرنٹ 30A ہے۔ جب آپ ان کو پیرالیل کنکشن میں لگائیں گے تو آوٹ پٹ وولٹیج 12V، کیپیسٹی 240Ah، اور کرنٹ 60A ہو جائے گا۔
Mera battery full hai par voltage 15.6 show hoti hai.mvut b 14.2 show huwi hai
Please ap jo nechy Adjustment scriow lga howa hy es ko Clockwise Ghomain
Suna ha ye baghair battry k bhi chal jata ha?
G bhai chlata hy mgr reske hota hy
Usko cutoff nhi float charging kehte hen.😅
Asan lfzun m btia hy bhy Bulk Absorption ya Float Charging ke chakr m ne pra
Mppt ky sath pmw lagana zarori hy.
Lga deen tu acha hy ne tu mppt pr dekhae de raha hota keh bty ktne reh gy hy menevely load band krna pre ga
Low voltage cut off kesd hooga 12 volt dc
Adjustment scriow ko Clockwise ghumain plz
Maira mppt to 14.0 tak battery charge kerta hai
Ap cutoff voltage 14.2 pr kren vereable secreo se
Ap ny pwm kun lgaya ha?
Bhai pwm 180w 2 panal kly lgaia hy 180w ke panal es ly lgy hn incase agr ap kr charge controller koe problem krty hn tu ap ka load Direct chl ske bhai mera bil 8000/9000 ata thaa last month only 2000 aia Ap koshish karen Dc load chalain es sy ap ko backup zeada mle ga
Price Kya hai hybrid ki or sada ki
Simple 9600 orr hybrid 10500
@@ZAEngineeringhub-Zulfiqar AP k pas available hai
کمپنی کٹ اف وولٹ سٹنگ کیے بغیر فروخت کرتی ہے ۔میرا ایک جل گیا تھا ۔
Bhai m ne jb lgia tu cutoff ne krta thaa battery garam ho jate thee phr m ne es ke settings ke ab yeh 14.8 pr cutoff krta hy battery bhe gram ne hote
Bro setting Kesy ho gi
@@ZAEngineeringhub-Zulfiqar setting kaisay kar li bhai... Hamay b batao
550 v ki ,1 plet hy
575w Canadian
kise kam ka Mppt ni total bakwas
Kaam chalata hy etny peson m