Rebar Splice Length & Location- Tagalog Tutorial

Sdílet
Vložit
  • čas přidán 12. 08. 2022
  • This video shows how to locate recommended Rebar Splicing points and lap lwbgrh as per NSCP section.

Komentáře • 28

  • @Damage_CTRL
    @Damage_CTRL Před rokem

    Ito dapat yung nag one milliom views hindi yung walang ka kwenta kwentang mga bloggers na wala naman katuturan.

  • @arielescala7991
    @arielescala7991 Před rokem +1

    Maganda ito para maeducate na rin ang mga nagpapagawa ng bahay na kapos sa budget at di na kayang maghire ng civil engr, importante talaga kasi maging economical at safe ang structure.

  • @emsnts1125
    @emsnts1125 Před 2 lety +1

    Very well explained!! 👏🏼👏🏼

  • @mrtams
    @mrtams Před měsícem +1

    Thank you God bless po

  • @kimberlymaesantos1660
    @kimberlymaesantos1660 Před 2 lety +1

    Hi sir, please cover din po yung commercial, procurement and QS topics. Maganda po kasi explanation nyo doon sa bid evaluation na video. Salamat po

  • @almajididjas7515
    @almajididjas7515 Před 2 lety +1

    Hi sir i hope gumawa rin kayo ng explanation about sa middle third ruling na usually ginagamit for pouring strip or construction joint. Salamat 😊

  • @reynaldosira5770
    @reynaldosira5770 Před 2 lety +1

    I'm your regular follower.for every new upload. Very informative

  • @richardneile.salalima54
    @richardneile.salalima54 Před 4 měsíci

    thank you sir

  • @jornlazatin8631
    @jornlazatin8631 Před 8 měsíci

    Thank you sir, new learnings ako palagi sa channel nyo.
    Question po, yung sinasabi po nila na 40d at 50d saan po galing ung splicing na yon?
    Thank you po.

  • @CheapTrick88
    @CheapTrick88 Před rokem

    question sir.. pareho lang po ba ang splicing at location ng extra bar pag sa footing tiebeam at grade beam? sabi kasi ni architect ay reverse sila pag nasa ibaba sila di pareho yung dinadala nilang load.

  • @jeynelsarraga4691
    @jeynelsarraga4691 Před 11 měsíci

    Sir pwde rin po ba ung 40d pra s slicing...???

  • @aeriskabkr1110
    @aeriskabkr1110 Před rokem

    Thanks, sa explanation sir, ganyan ang manner ng splicing na observed namin sa site.. Sir, tanong ko lang po kung paano at saan ginagamit ang formula for Lap Splice Lengths of Deformed Bars and Deformed Wires in Tension? nabasa ko lang po sa NSCP. Ang ginamit po dito na formula sa video is for Lap Splice Lengths of Deformed Bars and Deformed Wires in Compression

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  Před rokem +1

      As much as possible we avoid tension splice, but in rare cases always check moment diagram. Ensure all the required rebars are in-place within the tensile zone. Thanks

  • @pong3753
    @pong3753 Před 5 měsíci

    Sir sa NSCP po bawal naman po mag splice sa 2d sa bottom bars malapit sa face ng column..

  • @clutchplays4116
    @clutchplays4116 Před rokem

    Thank you Engr for the information. Just want to share na nagbabago po ang splice location if the member is intended for seismic purposes like girders. Btw po anong section po sa NSCP yung splice length formula? Thank you po

  • @bandz5433
    @bandz5433 Před 5 dny

    Sir sa lapping po ano po standard if contenues yong bakal? Salamat if masagot

  • @aeclint
    @aeclint Před měsícem +1

    So 300mm po min. ng lap splicing po ba sir?

  • @alexandermunasque2584
    @alexandermunasque2584 Před 2 lety

    hindi ba bawal mag splice sa support sir?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  Před 2 lety

      As long as you are within the comp. zone and let the aggregate pass through its good. Thanks

    • @alexandermunasque2584
      @alexandermunasque2584 Před 2 lety

      @@jsdesign_engineeringtv3633 thank you Sir.

    • @stephencano2737
      @stephencano2737 Před rokem +1

      for Special moment frames bawal mag splice sa support .. splicing is only allowed after twice the depth of beam from the support at 50 percent per beam cross section.. yung explanation ni sir sa splicing location at bottom bars at the support is only applicable for beams/girders recieving gravity loads only.. please see NSCP