Installation of Driven Precast Reinforced Concrete Piles

Sdílet
Vložit
  • čas přidán 12. 12. 2020
  • This video visually explain how the Installation of Driven Precast Reinforced Concrete Piles carried out at Construction Sites.

Komentáře • 33

  • @ravir9970
    @ravir9970 Před 2 lety +6

    A complete practical guide that can be used to train the pile driving as well as supervisor. Sincere appreciation to the team developed for their thinking, time to compile and share !

  • @sufianabalkisbintimohdshah1730

    a very helpful video in details to visualize the steps in piling, interesting, good job!

  • @ahmadfaraz1288
    @ahmadfaraz1288 Před 2 lety +2

    Thank you very. You just saved my time. I have a job interview presentation and was unable to visualize the driven pile.

  • @nonsoonwuasoigwe3743
    @nonsoonwuasoigwe3743 Před 3 lety +3

    Thanks

  • @juwainiSport
    @juwainiSport Před 11 měsíci +1

    Mantap squer pile

  • @galihjati443
    @galihjati443 Před 7 měsíci +1

    why square pile joint welding far much better compared to round concrete pile? is it the welder or the geometry?

  • @ibrahimabdul3138
    @ibrahimabdul3138 Před rokem +2

    When to strop the strike? How do we know that we are going to stop?

    • @ProudtobeaCivilEngineer
      @ProudtobeaCivilEngineer  Před rokem +1

      We have a set calculation to terminate the driving of pile. Check the playlist. We already have a video on this. Thank you.

  • @aisyahnurirdina
    @aisyahnurirdina Před 2 měsíci

    is this same with displacement pile precast concerete ?

  • @engineersworld742
    @engineersworld742 Před 2 lety +2

    Please provide method statement for this procedure with technical data.. thank you...

  • @adiborneo5676
    @adiborneo5676 Před 10 měsíci +1

    ,,,,,❤

  • @sanyego6021
    @sanyego6021 Před 6 měsíci +1

    MPI test purpose for what ?

    • @ProudtobeaCivilEngineer
      @ProudtobeaCivilEngineer  Před 3 měsíci +1

      Magnetic Particle Inspection (MPI), also known as Magnetic Particle Testing (MPT), is a non-destructive testing (NDT) method used to detect surface and near-surface discontinuities in ferromagnetic materials, such as iron, nickel, cobalt, and some of their alloys. Here's why it's particularly useful for inspecting welding:
      Detection of Surface and Subsurface Defects: MPI is effective in identifying both surface and just-below-the-surface discontinuities. In welding, this includes cracks, porosity, incomplete fusion, and other inconsistencies that might compromise the integrity of the weld.
      Immediate Results: MPI provides immediate visual results. The presence of any discontinuities is indicated by the accumulation of magnetic particles at the defect site, which can be seen directly. This immediacy aids in the quick assessment of the welding quality.
      Minimal Preparation Required: The surface preparation for MPI is relatively simple compared to other methods. The area needs to be clean, but extensive preparation is not necessary, making it a quick and efficient process for weld inspection.
      Sensitive to Small Defects: MPI is highly sensitive to small surface cracks and other discontinuities that might not be visible to the naked eye or could be missed by other NDT methods.
      Applicability to Complex Shapes: The method can be applied to complex geometries that are typical in welded structures. The magnetic field and the particles can conform to the shape of the object, making it versatile for inspecting welds in various configurations and positions.
      Cost-Effective: Compared to some other NDT methods, MPI is cost-effective, especially for the detection of surface and near-surface discontinuities. Its efficiency and speed also contribute to its cost-effectiveness.
      No Hazard to the Component: MPI is a non-destructive test that does not harm the material's structure or future usability, making it ideal for routine maintenance and inspection.
      In summary, Magnetic Particle Inspection is a crucial technique in welding to ensure the quality and integrity of welds, particularly in critical structures where strength and safety are paramount.

  • @user-hw3sh6ef2f
    @user-hw3sh6ef2f Před 3 lety +2

    Method Statement pdf please

  • @randybell5461
    @randybell5461 Před 2 měsíci

    I don't believe the piles don't crack when driving them into the ground. I wouldn't use them.

    • @Odagledtexas
      @Odagledtexas Před 2 měsíci

      14,000 PSI Concrete piles work just fine.

  • @mohanadassthanamsegeram3501

    How long should wait after welding

    • @ProudtobeaCivilEngineer
      @ProudtobeaCivilEngineer  Před rokem +1

      Usually, we are using Cooling Agents in the construction sites, in order to speed up the work. In that case, we may wait 2 to 3 minutes only.
      If we didn't use the cooling agents, we need to wait until the weld gets cold naturally. It will take 30 to 45 minutes.

  • @tofazzelhossain2918
    @tofazzelhossain2918 Před 2 lety +1

    Bad back sound. I dislike it

  • @samar4593
    @samar4593 Před 7 měsíci +1

    very bad

  • @samar4593
    @samar4593 Před 7 měsíci +1

    piless are circular bad civil engineer