PAANO MAG INSTALL NG SERVICE EQUIPMENT

Sdílet
Vložit
  • čas přidán 11. 01. 2022
  • KAILANGAN PABA NG SERVICE EQUIPMENT NG MAIN CUT OUT para sa multi-metering? in this video mga lodi share ko lang ang work ko padin sa 8 Unit Apartment in the 16th day of my work. so dito na nga sa service entrance, watch till end mga lods, kailangan paba o hindi na?
    WARNING! You must ensure that all electricity is turned off on any device that you will be working on. Failure to do any electrical work properly and in a safe manner can result in electrocution or fire If you are uncertain about any things shown in this video or do not understand the basic electrical procedure. I recommend that you hire a licensed electrician to do this work for you, We are not responsible for any injuries or damages caused while using the information provided in this video.
    DISCLAIMER!!! I am not a professional, but I can contribute my gathered knowledge, Experience, and skills in this video
    If you have any questions, feel free to comment down below
    #BasicElectrical
    #Knowleys
    #InstallationWorks8UnitApartmentDAY16

Komentáře • 112

  • @willieperalta2618
    @willieperalta2618 Před 3 měsíci +1

    Ayos master easy work salamat sa pag share

    • @galawangelectrical
      @galawangelectrical  Před 3 měsíci

      walang anuman lods, thans for watching, pa subscribe nalang lods, salamat. dami pa tayong mga videos jn.

  • @bertapartv
    @bertapartv Před rokem +1

    Salamat sa kaalaman lods

  • @AbiebayMiniSounds2020
    @AbiebayMiniSounds2020 Před 2 lety +2

    Ang galing tlga ng paliwanag sir amigo..ang laking tulong mga ideas at diskarte na sineshare mo. Ang linis ng gawa at Solid sir amigo..

  • @jaimevelasquez3754
    @jaimevelasquez3754 Před 2 lety +2

    malinaw Ang paliwanag mo ok Yan Ang tama

  • @reyelectrical
    @reyelectrical Před rokem +1

    Lods salamat sa infortion dapat tagala tayo sumunod sa electric provider para ma uprobahan ang gawa at di masayang. More power ka electrical

  • @DaniloJaime
    @DaniloJaime Před 2 lety

    Thanks lods may natutunan din ako. God Bless po

  • @lheaj1111
    @lheaj1111 Před 2 lety +1

    Mlaking tulong yang mga tinuturo mo host,salamat sa pag bahagi.

  • @naivivsoulfly
    @naivivsoulfly Před 2 lety +1

    Maganda bossing yung mga paliwanag mo talagang madami matututunan sa iyo.

  • @ismaeljingco5594
    @ismaeljingco5594 Před 9 měsíci +1

    50mm capacity breaker 150 amps.100amps lang main mo boss.8 units ka

    • @galawangelectrical
      @galawangelectrical  Před 9 měsíci +1

      yes lods walang nakuhang 38mm2 na wire, yan ang available. wala naman problema kung malaki ang service entrance. ang 100A main cutout eh ayun sa load schedule. kung mag upgrade ng cutout pwede, walang ibang babaguhin kundi breaker lang. every unit sa sched mababa lang lods. mag 1yr na yang 100A di naman nag trip para sa overload. fully occufied ang mga unit.

  • @pejarckskilledwtv1081
    @pejarckskilledwtv1081 Před 2 lety +1

    ayus boss. ganda mo magpaliwanag malaking tulong sa mga maguhan.

  • @SamanthaUyTV
    @SamanthaUyTV Před 2 lety

    Cheers kapatid sa very informative share mo

  • @e-benguetlynden2323
    @e-benguetlynden2323 Před 2 lety +1

    Ayos na ayos idol.

  • @juliesdiary7229
    @juliesdiary7229 Před 2 lety +1

    gustong gusto kong pinapano od ang trabaho mo friend napakagaling mo po.

  • @BongHanglaGirl
    @BongHanglaGirl Před 2 lety +1

    Great video very informative thank you very much for sharing my good friend happy new year keep safe always have a wonderful day 👍

  • @KataTukuTV
    @KataTukuTV Před 2 lety +1

    more power sir
    salamat sa malinaw na tutorial sir

  • @amytyson3164
    @amytyson3164 Před 2 lety +1

    INGAT KAPATED GREAT SHARING

  • @christianmueca7524
    @christianmueca7524 Před 2 lety +1

    Ayos nanaman to lods! Very informative. Keep it up!

  • @NanaySakusinamixvlogs
    @NanaySakusinamixvlogs Před 2 lety

    Very informative kuya malaking tulong yan sa gusto matuto

  • @jcshaven6093
    @jcshaven6093 Před 2 lety +1

    good job again amigo

  • @Tutorial_Ref_Aircon_more

    good eve lodi

  • @Mstrknk
    @Mstrknk Před 2 lety +1

    nagulo ang isipan ko, ikaw na bahala diha bro

  • @rogernbackyard6677
    @rogernbackyard6677 Před 21 dnem

    Thanks po sir,,sakto may gawa ako nyan ngayon,,ask ko lang sir kung magkanu price sa pagterminate lahat,,,main breaker,wire gutter at breaker gutter,,,,para po may idea po ako,,,,sana mapansin

    • @galawangelectrical
      @galawangelectrical  Před 21 dnem

      diko na kasi iniisip yung ibang materials, kung baga as is na yan. yan ang gagamiting materials, kaya pinapakyaw ko nalang yan. 1500 isang meter lodi. installation from entrance cap gang ground rod, installation and termination ng wires ng meter at ng mga breaker cutout. at main pala ng meter center.

  • @Panda.0038
    @Panda.0038 Před 2 lety +1

    Ayos yan lodi lods may tanong lang Po Ako kasi Po nag ayos Po kami Ng wire Ng receptacle bakit Po kaya malkas parin koryiente kahit naka off na Yung switch Ng ilaw 😀

    • @galawangelectrical
      @galawangelectrical  Před 2 lety

      line to line ata ang power source nyo lods, kung may ayusin lagi ko sabi lods off the breaker para safety tyo. sa switch is isang line lang kina cut nyan. means meron pa yung isang line, kung line to line ang power source nyo. kaya much better and dapat lagi practices is lagi mag off ng breaker lodi.

    • @Panda.0038
      @Panda.0038 Před 2 lety

      @@galawangelectrical ok salamat po lods

  • @loydfernandez5490
    @loydfernandez5490 Před rokem +2

    sir pag 60 mm2 po ba nakalagay NA service entrance , kelangan bang 60 mm2 padin ang wire mula sa metro hanggang nema 3r enclosure or pwede na ang 8.0mm2 ? ang nakalagay kse sa plano e 8.0 mm2 mula nema 3r hanggang sa lighting popwer panel (LPP) , apartment po 8 units. , .?

    • @galawangelectrical
      @galawangelectrical  Před rokem

      yes lods dapat ganun, kung anu sa service entranace, sa meter pa baba ng breaker, dapat parehas ng size. bat maging 8mm lnag lods? ah sa LPP lang yan, kung yan naka lagay sa drawing ok lang yan,, bukod pa ang mga breaker ng kada unit? iniisip ko anung ilaw ang laman ng LPP., lods sa fb page ko , message ka dun, para maka reply ako agad, pag dito kasi matagal hehe.

  • @jaimecoronacion4928
    @jaimecoronacion4928 Před 2 lety +2

    Bakit po 100 amp lang Yung disconnection service ?
    Sorry sir baguhan lang po sa electrical

  • @gmcelectricalelectronicsse8575
    @gmcelectricalelectronicsse8575 Před 10 měsíci +1

    Sir bakit po sobrang kaki ng size bg wire para s 100 amps n breaker, dapat po ay 30 to 38mm2,

    • @galawangelectrical
      @galawangelectrical  Před 10 měsíci

      di ako sure dun sa nakuha ng cliet na wire lods, pero parang 38mm2 lang yan. ang nasabi ko ata is 50mm2. dun sa size ok lang na malaki yan lods. service entrance yan. may first service cutout and may mga branch. and apartment dwelling yan as multi dwelling. and every dwell may main may mga branch. kaya ok lang kung mas mataas sa rating ang wire sa rating ng cutout, specially kung service entrance yan.

  • @loydfernandez5490
    @loydfernandez5490 Před rokem +1

    lods paPASOK PO BA ANG 60MM2 NA WIRE SA TURNILYUHAN NG METRO?

    • @galawangelectrical
      @galawangelectrical  Před rokem

      jan sa video lods, may nilagay akong lug, screw type, means di na ako gumamit ng crimper. and yes pasok ang 60mm2, depende sa mabibili mong lug.

  • @warrdudez25
    @warrdudez25 Před 8 měsíci +1

    sir anong size ng service drop wire sa meralco? same po ba sa size ng patungo breaker? 38mm?

    • @galawangelectrical
      @galawangelectrical  Před 8 měsíci

      yes parang 38mm2 ang drop wire nila lods. yung service entrance 38mm2 din yan. di ako sure kaya nasabi ko jan sa video ai 50mm2 pero 38mm2 yan.

  • @paanovlog3296
    @paanovlog3296 Před rokem +1

    Lods ask ko lang po standard height ng mga gater na na install niyo po at anong tawag nong box nanasa taas namay pvc ano po purpose niyan?thanks

    • @galawangelectrical
      @galawangelectrical  Před rokem

      meter base ang dapat naka standard ang height lods, kelangan readable lang ng provider 5ft. pataas ang nirerequired nila. lagyan mo lang ng 2inch or 3 inch nipple rsc pipe bottom na yun ng auxilary gutter or busbar gutter or wire gutter, jan naka terminate ang mga incoming ng lahat ng meter.

  • @joeben6834
    @joeben6834 Před rokem +1

    Sir, my wire gutter box dito n 4 units gusto ko sana e upgrade sa no.8.0 pag pina alam b sa meralco ano mga requirements ? At nasa loob siya ng compound ng bahay pag nag pa survey ba sa meralco my posibilidad ba n ipalipat ng location ito? Thanks

    • @galawangelectrical
      @galawangelectrical  Před rokem

      4 units anung wire naka lagay lods? bat upgare ka ng 8? ilang units paba ipadagdag mo? kung madami ka idagdag lods, need mo ipa alam yan sa meralco. para mapalitan nila yung service drop, kung anu ang dapat need na load, yun ang ilagay nilang wire.

  • @francisjoydelacruz7249
    @francisjoydelacruz7249 Před 2 lety +1

    Lodz ganyan. Din ba ginagawa para sa commercial building

    • @galawangelectrical
      @galawangelectrical  Před 2 lety

      yes lods, mas prepared nila yung meter center, concentrated yung mga meter sa isang lugar lang kung marami.

  • @armiquiogue331
    @armiquiogue331 Před 17 dny +1

    Sir, magkano ngaun singilan sa 8 unit multi meter service entrance installation. Ty. Wala kc ako idea kung magkano sBihin ko sa contractor.

    • @galawangelectrical
      @galawangelectrical  Před 16 dny

      iba iba yan lods depende sa gagawa. katulad q freelance lang may mga iba din akong pinag gaga gawa bukod sa electrical works. aq sakin, pine presyuhan q yung ganyan per meter lang lodi. kung ilan ang meter yun ang price ko for installation and termination ng multi metering lods. pag kc contructor na malaki iba presyuhan nyan lods. saan ba location mo?

  • @marvindelacruz8454
    @marvindelacruz8454 Před 2 lety +1

    Ano po bah kylangan bro bakit lagi nag shout down ang breaker kulang po bah supply o my trouble sa wireng po salamat po sa sagot

    • @galawangelectrical
      @galawangelectrical  Před 2 lety

      ang ordinary na breaker is mag trip sa over current at short circuit. may mga dahilan din bakit nag oover current. gawa yan ng wires, ng connection, ng splice. or kahit sa mga naka turnilyo, minsan nag loose yan. umiinit ang terminal kaya nag trip din gawa nyan. pwede mong gawin check mo yung mga wires mo, mga connection, higpitan lahat ng turnilyo lahat ng splices check mo, para iwas din sa mga ganyan, yan ang preventive mentenance lods.

  • @garryesguerra8032
    @garryesguerra8032 Před rokem +1

    Maganda un gutter lods stainless,mgkano singilan dyn sa pagsetup Ng meter base?

    • @galawangelectrical
      @galawangelectrical  Před rokem

      labor and termination pwede na 1k to 1.5k jan per meter, gang sa grounding.

    • @garryesguerra8032
      @garryesguerra8032 Před rokem

      Panu nman.lods un ipapalipat un metro mgkano rate Ng electrician dyn malapit.lng ilalabas lng gate?

  • @loydfernandez5490
    @loydfernandez5490 Před 11 měsíci +1

    sir ano poang sukat ng wire gutter ang kakasya sa 9 meter base apartment unit po ongoing project ko. hoping masagot nyo po ako., Godbless po sir

    • @galawangelectrical
      @galawangelectrical  Před 11 měsíci

      ang ginagawa kong sukat lods, size ng meter base + 2cm + meterbase + 2 cm. ganyan lang sukat nyan lodi. ang meter base ai 18cm yan. yung 2 cm jan eh depende yan sa pipe na ilagay mo kung anung size yan. kung pang residentials housing 1inch lagay mong pipe. so alternate yung meter isa sa taas isa sa baba. makikita mo naman yan katulad jan sa video lods.

    • @loydfernandez5490
      @loydfernandez5490 Před 11 měsíci +1

      @@galawangelectrical salamat posir.

    • @galawangelectrical
      @galawangelectrical  Před 11 měsíci

      @@loydfernandez5490 walang anuman lods

  • @StickerShockPH
    @StickerShockPH Před 2 lety +1

    Lods out of topic ang tanong ko, bakit umuugong ang led light kahit patay sya may ugong.

    • @galawangelectrical
      @galawangelectrical  Před 2 lety

      pwedeng interference ng other device lods, electronically operated ang mga led light, check mo i off yung iabng electronics jan sa outlets mo, check mo if ganun padin, or if line to line ang power source nyo, may isang line na nag cause para naka stay active ang mga components ny like mga capacitor. isa yan sa nag cause ng humming sounds.

  • @MarcoChico-b2m
    @MarcoChico-b2m Před 19 dny

    Boss pag10 apartment Ang gagawin anung size Ng wire Ang gagamitin service entrance wire Anu wire

    • @galawangelectrical
      @galawangelectrical  Před 19 dny

      dep3nde sa load schedule ng building lodi. sa laki ng building na yan 10 unit hahanapan ng building permit yan, at bago mk kuha ng permit yan need yan may drawing yn pirmado ng engineer. so dun mo mkita ang gagamitin mo wire na approve ng engineer na gumawa ng drawing. hindi lods yan yung basta basta yun lang ilagay, as per drawing yan.

  • @ricklindamasco2071
    @ricklindamasco2071 Před rokem +1

    Lodi kaw nlang po ba gumagawa ng break gutter.saan mo nabibili yan pang MCB na breaker

    • @galawangelectrical
      @galawangelectrical  Před rokem

      hindi lods, yung may ari ang bumili ng gutter, puro install lang ako. sa breaker kung anu yung nasa schedule yn sinasabi ko na bilihin. katulad ng MCCB nabili, breaker yang need na may lug ang wire, wala tayong crimping tool, so pinabili natin yung may ari ng screw type na terminal lug pa pwede dun sa breaker. meron namang nabibiling ganun. chek mo lods bagong upload kong video. mga meter base din yun. bak mag ka idea ka.

    • @ricklindamasco2071
      @ricklindamasco2071 Před rokem +1

      @@galawangelectrical ok lods ayus.

    • @ricklindamasco2071
      @ricklindamasco2071 Před rokem +1

      @@galawangelectrical lodi anung pinagkaiba ng ganyan na meter base kaysa sa isang metro.lode paanu po pag line to ground connection po

    • @galawangelectrical
      @galawangelectrical  Před rokem

      @@ricklindamasco2071 ang iba iabng klase ng meter base ai mag base yan sa capacity ng terminal lods, may bago akong video lods andun sinabi ko yang sa meter base. may video din tayo about sa line to line at line to ground, sa connection rty ko yan gawan ng video lods,

  • @yuji1919
    @yuji1919 Před rokem +1

    Bos asan po yung main meter nyan?

    • @galawangelectrical
      @galawangelectrical  Před rokem

      walang main meter yan. lahat ng meter na yan ai main ng kada unit. at di na kailangan ang main meter jan kasi kada unit may meter na, sila na bahala mag bayad jan per meter.

  • @ericsonnavalta1343
    @ericsonnavalta1343 Před rokem +1

    Sir Anong sukat ung breaker gutter mo? May standard b Yan.

    • @galawangelectrical
      @galawangelectrical  Před rokem +1

      depende yan sa dami ng ilagay mo na breaker lods, yun ang haba ng gutter. yung sa taas need mo lang na maluwag yung breaker ka sa loob lods, jan sa ginawa ko, ang sukat nyan 20cm maluwag na yung mcb jan. yung depth 15cm to 20 cm maluwag na yan.

    • @ericsonnavalta1343
      @ericsonnavalta1343 Před rokem +1

      Thank you Sir.

    • @galawangelectrical
      @galawangelectrical  Před rokem

      @@ericsonnavalta1343 your welcome lods

  • @marilynlaranang2465
    @marilynlaranang2465 Před 2 lety +1

    Boss my main meter paba yan?

  • @reynaldopolintan9879
    @reynaldopolintan9879 Před 2 lety +1

    Meter box one unit po b or sub meter po

  • @nakedshot
    @nakedshot Před rokem +1

    Anu kaya ang size ng wire ginamit kada apartment ¿?

    • @galawangelectrical
      @galawangelectrical  Před rokem +1

      nirerequired ng electrical service provider na #8 ang gamitin. para yan sa normal na dwelling unit. kasama na jan ang apartment unit. matic yan `#8. pero kung mas malaki ang load mo, mas lalaki pa ang wire. ang apartment kasi is normal consumption lang yan.

    • @nakedshot
      @nakedshot Před rokem +1

      @@galawangelectrical pahabol na tanong sir halimbawa sir 30 amp breaker syempre para 10# guage yun , pero pwede ba may existing na 12# guage wire mag parallel ng isa pang 12 para sa 30 amp breaker halimbawa lang kunyari tinatamad palitan dinagdagan nlang pede ba sir?

    • @galawangelectrical
      @galawangelectrical  Před rokem +1

      @@nakedshot para saan lods? kung para sa outlet, ok lang #12 yan sa 30A. kung titingnan mo sa table ng ampacity ng mga wire. ang thhn #12 eh umaabot yn ng 30A lods. sa thhn ha.

  • @jekyllandhydewithjet5926
    @jekyllandhydewithjet5926 Před 2 lety +1

    sir yung cutout mo 63 amp po, yung sa loob ng unit sa main panel distribution box, anu po yung ginamit nyo po na main circuit breaker? (mcb) ilang amp po?

    • @galawangelectrical
      @galawangelectrical  Před 2 lety

      40A ang main sa kada unit lods, watch mo to. czcams.com/video/Ku0WOIeLVkE/video.html

    • @jekyllandhydewithjet5926
      @jekyllandhydewithjet5926 Před 2 lety

      @@galawangelectrical sir thank you, dami ko natutunan sa mga videos mo.. pinapanuod ko sila from time to time. yung mga teknik mo sir, ginagaya ko. ito dito yung example sa wiring sa breaker sa mcb, sa gutter box. para kapag may tumulo na patak ng tubig, kung sakali man. sure ball na hindi directang madadali ang mcb.

    • @galawangelectrical
      @galawangelectrical  Před 2 lety +1

      @@jekyllandhydewithjet5926 your welcome lodsm dami ko nakikita nyan lods nasusunog, findings nabasa, hehe. direst naka tapat yung butas sa breaker. kaya yan lagi ko gawa, naka lihis sa breakaer ang butas. dami pa tayo mga video jan lodi

    • @jekyllandhydewithjet5926
      @jekyllandhydewithjet5926 Před 2 lety +1

      @@galawangelectrical yes sir, since nasa labas ang mga gutter box prone sa katagalan sa leak ng paunti unting overtime na naiipon na patak ng tubig. lalu na yung walang mga maintenance checkup. tapos napansin ko dito sa street namin ang mga gutter breaker sa daanan ng wire sa tubo tapat talga sa breaker. dami nyo video sir, from time to time pinapaunod ko at review. maraming salamat sir sa pag share.

    • @galawangelectrical
      @galawangelectrical  Před 2 lety +1

      @@jekyllandhydewithjet5926 yes lods, kung sa degree of protection ng mga enclosure ang pag uusapan, bagsak na bagsak yung mga andito satin sa pinas, compare sa ibanag bansa lods. yung ginamit jan sa video na yan is stainless yan, pero pabricated lang, means hindi yan ganun ka 100%seal for outdoor use. and kahit yung mga nakikita natin na gather na coated lang pero on working na means na approve na. ganun ka luwg dito satin sa pinas lods, kaya tayo nalang ang gagawa kung panu natin magawa ng maayos ang work natin. thanks for watching my videos lods.

  • @paanovlog3296
    @paanovlog3296 Před rokem +1

    -Pag ganyan lods ano best reccoemnd mo gamitin na main cutout na breaker RCBO/RCCB ba or MCB?
    -Tyaka lods may nabibili ba na RSC pipe na ganyan na pagkaka iksi at threaded na?
    maraming salamt lods binalikan ko video mo

    • @galawangelectrical
      @galawangelectrical  Před rokem

      jan sa video lods, main disconnect yan. main cutout yan ng 8 unit apartment. kaya di pwede jan ang rcbo or rccb. mcb lang ok na jan. kung liek mo mag lagay ng rcbo or rccb sa panel mo na ilagay yun ng kaba unit.

    • @paanovlog3296
      @paanovlog3296 Před rokem

      @@galawangelectrical maraming salamat idol,,,maganda naba ang scheineder 60 AT sa bahay lang main cutout?

  • @naivivsoulfly
    @naivivsoulfly Před 2 lety +1

    Maganda bossing yung mga paliwanag mo talagang madami matututunan sa iyo.