6. ABB ACS880 Drive Basic Startup and Commissioning

Sdílet
Vložit
  • čas přidán 29. 08. 2024

Komentáře • 50

  • @dalvrzx
    @dalvrzx Před rokem

    Thank you for such detailed guides!

  • @nihalvarma2953
    @nihalvarma2953 Před rokem

    very informative and useful, thank you

  • @williansousa415
    @williansousa415 Před 2 lety

    Muito bom. Parabéns pelo vídeo. Ajudou muito.

  • @nakul104
    @nakul104 Před 3 lety +2

    Also make a vedio master slave configuration with Encoder

  • @denishpatel8830
    @denishpatel8830 Před 2 lety

    Hello Dexter,
    Nice work as always....kudos to your efforts...
    Can you share video which shows controlling of drive start and speed using modbus communication?

  • @user-um6iq8dc2w
    @user-um6iq8dc2w Před 2 lety

    Bravo!

  • @rajibadhya8653
    @rajibadhya8653 Před 2 lety

    Awesome......

  • @tukaramjambhale831
    @tukaramjambhale831 Před rokem

    Thanks ❤

  • @rashedsyed5412
    @rashedsyed5412 Před 6 měsíci

    HI thanks for the info .
    But I checked you are using two additional module and you are not defining them in 7. system info .
    Could you please clarify the same.

  • @renannatalisuman3805
    @renannatalisuman3805 Před rokem

    I've installed an ACS880 to control a cooling tower fan, whose power is 55kW, and the cabling distance is 100m. When I started the drive at full speed (60Hz) high noises appeared, but operating in low speed (30-40Hz) there were no noise. What could it be?

  • @srinivasreddy8842
    @srinivasreddy8842 Před 2 lety +1

    Can u suggest me ,How to eliminate motor speed fluctuation during starting time
    What exactly parameter to be change

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      Hi, you could change the start stop mode in parameter 21 to constant time and define the magnetization time to magnetize the motor before giving a start command. This will normally make sure there is enough torque to follow the speed ref. Or another method is to enable brake function and define starting torque if your motor have a mech brake.

  • @ch.industrialelectricity5625

    Hello! For acs880 inverter series, the motor needs to be connected to the encoder to work, right?

  • @Villegasedyjhon
    @Villegasedyjhon Před 3 lety +1

    Por favor, pude grabar un video del mismo tema pero bien nítido. Te agradezco un monton:
    Quiero igualar los tiempos de las rampas al tiempo medido con mi cronómetro por favor quiero saber que parámetro mover

    • @averageengineer4266
      @averageengineer4266  Před 3 lety

      Iam guessing you want to control the ramp time.
      Parameter 23.11 - Set it to ACC/Dec Time 1
      Parameter 23.12 - Enter the acceleration time in Seconds
      Parameter 23.13 - Enter the deceleration time in Seconds

  • @jamesbond0004
    @jamesbond0004 Před 2 lety

    Thank you kindly, that was very informative.
    can i ask though to be clear, exactly how did you choose between torque control and speed control modes, because the local control was giving a speed ref? i guess that will be covered at next stage. interested in seeing how you setup the paras for direct tension control example in a rolling mill application
    do you do on-line training by the way? i would be interested ..

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      Thank you, i have made a video for tension control some time back. Pls see - czcams.com/video/_hjVjPl-pJM/video.html

    • @jamesbond0004
      @jamesbond0004 Před 2 lety

      I will check it out, thank you kindly

  • @sushildhariwal8694
    @sushildhariwal8694 Před 2 lety

    Hello Dear
    May I know why torque is not affected in ID run?

  • @nakul104
    @nakul104 Před 3 lety +1

    Boss pl make vedio on HD quality so easily see all parameters

    • @averageengineer4266
      @averageengineer4266  Před 3 lety +1

      Hi, the vid is in HD , pls change the quality to 1080p and thanks for watching

  • @irwaniwan8137
    @irwaniwan8137 Před rokem

    What's the parameter for a set start forward & reverse?

  • @ILAYARAJAraja
    @ILAYARAJAraja Před rokem

    I cannot change the drive I'd 2 to 1? And I follow the Drive-id2-Change id1-enter, but I cannot change, please share the information if you know, thanks

  • @Sm_robux9
    @Sm_robux9 Před 2 lety

    Sir please explain dc bus charging and dishcharging concept in acs 800

  • @abhi9823179961
    @abhi9823179961 Před 2 lety

    We have 3 motor and all 3 motor Igbt got burnt
    ACS880-01 abb model
    Now it’s expensive to change complete vfd.
    So at least I can interchange some card to make 1 vfd good.
    I have ordered one Igbt and zgad-571 drive card.
    I want to do bench test without connecting motor, is it possible to do ?
    I can manage to give mA signal to control.
    Secondly what is root cause of Igbt burnt? What should I check ?
    Kindly suggest

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      Hi, in my experience IGBT failures are mostly due to a faulty card in the drive or if the moisture get inside and cause a short circuit. You can change DTC to scalar in parameter group 99 to test without a motor

    • @abhi9823179961
      @abhi9823179961 Před 2 lety

      @@averageengineer4266
      Ok thanks
      So only changing DTC parameter will do?
      Further investigation found one IC found burnt on control board(ZCU-12).
      Any procedure to test without motor plz share.

  • @himansusahu8850
    @himansusahu8850 Před rokem

    sir can you explain how to assigned all the DI in parameter in detail

  • @electricalmotorsanddrives7206

    Sir Please guide me how to connect abb acs 880 with profibus dp means software and plc changes.

    • @averageengineer4266
      @averageengineer4266  Před 3 lety

      Hi, pls check this video -
      czcams.com/video/Y2pvitN9JcM/video.html

    • @averageengineer4266
      @averageengineer4266  Před 3 lety

      czcams.com/video/jJV1J-R_4hM/video.html

    • @electricalmotorsanddrives7206
      @electricalmotorsanddrives7206 Před 3 lety

      Sir my previous drive (abb acs800) and it is running on profibus dp we want to replace it with acs 880 . Our plc is modicon quantam series.

  • @ganeshmmn8211
    @ganeshmmn8211 Před 2 lety

    We have a drive ACS 880 that is not getting on what is the reason

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      May be u forgot to switch on power😜, jokes aside, there are a lot of reasons, very difficult to answer without seeing it..

  • @user-um6iq8dc2w
    @user-um6iq8dc2w Před 2 lety

    How i can change control or status word 0-1? this parameter is read only.

    • @averageengineer4266
      @averageengineer4266  Před 2 lety +1

      Status word is read only, but in control word you can write. Which plc are u using?

    • @user-um6iq8dc2w
      @user-um6iq8dc2w Před 2 lety +1

      @@averageengineer4266 oh bro, i don't know PLC ( . hot dip galvanized line. I am electrical. Automation using tia portal.

  • @Sm_robux9
    @Sm_robux9 Před 2 lety

    Sir i m interested training of plc dcs and drive

  • @rishinathreghu579
    @rishinathreghu579 Před rokem

    hi sir ,i am facing an issue in communication with drive

  • @vfdrepairinglab
    @vfdrepairinglab Před rokem

    Plz i need drive composer pro register key

  • @murhafmahfoud9469
    @murhafmahfoud9469 Před 2 lety

    hello
    Iwant to ask about charging the busbar or capacitors using external charger after along time of storing
    Why we do that or can privide me any file about that .
    As quick as you can
    Thank you very much

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      Hi,
      There is a possiblity for the capacitors to blast if it is not used for a long time. So in this case , it is better to charge the capacitors slowly rather than directly applying the normal voltage. Normally we use an auto transformer and rectifier , so that we can slowly increase the voltage.

    • @murhafmahfoud9469
      @murhafmahfoud9469 Před 2 lety

      @@averageengineer4266 thank you very much
      Can you determined witch capacitors please.
      and if you have any file show how to do it .
      Because i searched about this subject alot i didnt find any thing .
      Thank you again .

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      @@murhafmahfoud9469 you dont need to open the drive and charge capacitors, the external dc supply can be directly connected to dc link of the drive and slowly increase the dc supply by 100 V steps.

    • @averageengineer4266
      @averageengineer4266  Před 2 lety

      And also since it involves damaging the drive , pls consult with the manufacturer before doing

    • @murhafmahfoud9469
      @murhafmahfoud9469 Před 2 lety

      @@averageengineer4266 i know we dont need to open the drvie .
      But can you determined which capacitor we need to charge
      because i have to prepare a report about that .
      Also if any file exist that will be great
      Thank you very much