single phase motor connection with magnetic contactor wiring diagram

Sdílet
Vložit
  • čas přidán 6. 08. 2020
  • A single phase motor is an electrically powered
    rotary machine that can turn electric energy into
    mechanical energy. it works by using a single phase
    power supply. they contain two types of wiring hot
    and neutral. their power can reach 3Kw and supply
    voltages vary in unison.
    what is single phase water pump?
    single phase water pump a single phase pump runs on a
    single phase power supply. three phase water pump
    a three phase motor water pump needs three phase power
    supply. it has a simple design with small body size it
    can be highly efficient with high starting torque.
    why magnetic contactor is used
    Magnetic contactors are used in the electric motors
    to balance the change in frequency of the motor or
    the state of the motor which can be termed as the
    switching of the motor from on and off state.
    magnetic contactors act as a safeguard to protect
    the power supply and the motor.
    (MCB) Miniature Circuit Breaker
    Miniature Circuit Breaker MCB automatically switches off electrical
    circuit during an abnormal condition of the network means in overload
    condition as well as faulty condition.Now days we use an MCB in low
    voltage electrical network instead of a fuse.
    #motor #connection #wiring
    THANK`S FOR WATCHING THIS VIDEO
    PLEASE LIKE COMMENT SHARE AND
    SUBSCRIBE THIS CHANNLE
    / @jrelectricschool
    house wiring electrical switch board connection diagram
    • house wiring electrica...
    inverter wiring connection
    • inverter wiring connec...
    float switch connection auto & manual single phase water pump
    • float switch connectio...
    automatic changeover switch for generator
    • automatic changeover s...
    reverse forward dol starter control wiring
    • reverse forward dol st...
    electrical hand tools
    • electrical hand tools
    electrical house wiring full video
    • electrical house wirin...
    full house wiring diagram gang switch
    • full house wiring diag...
    float switch wiring diagram for water pump
    • float switch wiring di...
    split ac wiring diagram indoor outdoor single phase
    • split ac wiring diagra...
    star delta connection 3 phase motor diagram
    • star delta power wirin...
    complete electrical house wiring diagram
    • complete electrical ho...
    Submersible Motor Control Box Connection
    • Submersible Motor Cont...
    DOOR BELL WIRING DIAGRAM MULTIPLE SWITCH AND SERIES LAMP
    • DOOR BELL WIRING DIAGR...
    reverse forward dol starter power wiring
    • reverse forward dol st...
    single phase mcb distribution db box connection diagram
    • single phase mcb distr...
    house wiring single phase energy meter with light fan connection
    • house wiring single ph...
    3 phase distribution DB box wiring diagram
    • 3 phase distribution D...
    ELECTRICAL HOUSE WIRING WITH SWITCH BOARD CONNECTION
    • ELECTRICAL HOUSE WIRIN...
    Two Way switch Connection with light electric animation video
    • Two Way switch Connect...
    Music in this video
    Song: Erik Lund - Summertime (Vlog No Copyright Music)
    Music promoted by Vlog No Copyright Music.
    Video Link: • Video
    keyword:
    single phase motor connection
    single phase motor connection bangla
    single phase motor connection english
    single phase motor connection diagram
    single phase motor connection tamil
    single phase motor connection malayalam
    single phase motor connection with contactor
    single phase motor connection telugu
    single phase motor connection capacitor
    single phase motor connection with capacitor
    single phase motor connection animation
    how to connect a single phase motor to a 3 phase supply,
    single phase electric motor wiring
    single phase 220v motor wiring diagram
    single phase borewell motor connection
    single phase motor panel board connection
    single phase motor delta connection
    3 hp motor single phase connection
    5 hp single phase motor connection
    1 hp single phase motor connection
    single phase submersible motor starter connection in hindi
    single phase motor wiring
    connection of single phase motor
    single phase motor connection pdf
    single phase motor connection submersible
    single phase motor connection with centrifugal switch
    3 phase electric motor connection
    single phase 1hp motor connection
    1.5 hp single phase motor connection
    1 hp single phase submersible motor connection
    2hp single phase motor connection
    single phase motor 2 capacitor connection
    single phase 4 wire motor connection
    single phase 5hp motor connection
    6 wire motor connection single phase
    single phase 230 volt motor wiring diagram
  • Věda a technologie

Komentáře • 139

  • @ismaelmateoramirez3098

    Excelente ingeniero saludos gracias

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety

      sorry i am not understand your language
      please tell me Bangla,Hindi,English.
      Thank you.

  • @galawangelectrical
    @galawangelectrical Před 3 lety +5

    thanks for this simple but clear tutorial,

  • @leizhang7415
    @leizhang7415 Před 2 lety +2

    Thank you for your video. What kind of push button switch do I need to use? I bought momentary switch before I didn't know. When I finished wiring only working while I keep pushing 'start button', I think I need different kind of push button switch.

  • @shukruallahbaig4542
    @shukruallahbaig4542 Před 3 lety +1

    Good informative video sir very thank s

  • @epifanomoyojr9625
    @epifanomoyojr9625 Před 2 lety +1

    Very helpful Thank you

  • @Ingenioushacks.0609
    @Ingenioushacks.0609 Před 3 lety +1

    amazing video #dtntechnology

  • @manit77
    @manit77 Před 3 lety

    USA some instances 220v is transmitted over two lines and the third line is neutral.

  • @joew4202
    @joew4202 Před 3 lety

    I have a 3 phase OL I’m using on a 1 phase motor. The OL has 4 NO contacts, what do I use them for ? I can’t control the motor with the NO contacts correct ? The NO contacts have continuity(13,14). Do I need a separate contractor to make it work ?

  • @aldino2168
    @aldino2168 Před 3 lety +1

    Useful content

  • @sham1234567891
    @sham1234567891 Před 2 měsíci

    Great stuff! Could you please give the list of magnetic contactors and and MCB used in your video?
    Thanks and warmest regards.

  • @sammyltube2406
    @sammyltube2406 Před 3 lety

    Buena explicación

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety +1

      sorry i am not understand your language please tell me Bangla,Hindi,English. Thank you.

  • @blasivlog24
    @blasivlog24 Před 3 lety +1

    Wow ang galing nyo po idol

  • @richardondie
    @richardondie Před rokem +1

    Thank you

  • @ZafarIqbal-kk2qm
    @ZafarIqbal-kk2qm Před 2 měsíci

    Thanks so good teach agan thanks

  • @awaazmatroko5972
    @awaazmatroko5972 Před 2 lety +1

    I have seen many of your videos it's good! You have done a good job, I have a query I was searching on the net , but all don't fit the bill, I have a 3 phase 5hp water pump I need the following sensor : sump tank water level + timer on/ off , dry run - phase check. Auto on off...pls help.

    • @JrElectricSchool
      @JrElectricSchool  Před 2 lety +1

      please watching this video
      czcams.com/video/EGMH4TrNJs8/video.html

  • @cesarcastillojr
    @cesarcastillojr Před 3 lety +1

    Nice one

  • @engineer6877
    @engineer6877 Před 3 lety +1

    beautiful video what is the name of software that you are using

  • @kmndza
    @kmndza Před rokem +2

    youve got a wrong way to put a supply into the circuit breaker i think, supply side/incoming should be on the top side of the CB and the load side/outgoing should be on the bottom side of the CB. Do you agree?

  • @alexbrooks3142
    @alexbrooks3142 Před 2 lety

    Doing some research for my job, I really wish that there were less lines. Can someone link me to the eastern european/Russian electronics? JK, this video was actually very helpful.

  • @rakibelectricbd5561
    @rakibelectricbd5561 Před 3 lety

    ভাই আপনার ভিডিও সব গুলো আমি দেখি আমার অনেক ভালো লাগে,,,, ভাই আমার একটা চেনেল আছে আপনি যদি আপনার বন্দুর কাছে সিয়ার করে দিতেন,,, তাহলে আমার অনেক উপকার হতো,,,,,আমার চেনেল এর নাম,,, Rakib Electric BD,,,

  • @shankarvaigankar8116
    @shankarvaigankar8116 Před 11 měsíci

    Can I use modular contactor of Ac7a and Ac7b rating instead of Ac-3 rating. It will be safe to connect 2000watts single phase motor.

  • @felipejr.arnoza9672
    @felipejr.arnoza9672 Před 3 měsíci

    Salamat sa vedio nato

  • @stevenleebass
    @stevenleebass Před 3 lety +1

    are those available in the US? I have only been able to find availability outside the country

  • @abbc1495
    @abbc1495 Před 3 lety +1

    good job

  • @mwalimali6677
    @mwalimali6677 Před 2 lety +1

    Good job

  • @DIMA-fu3uf
    @DIMA-fu3uf Před 3 lety +1

    👍🏼👍🏼

  • @mitchellburnette1341
    @mitchellburnette1341 Před 2 lety

    What if I am using a micro switch instead of the push buttons?

  • @Savagethehome
    @Savagethehome Před 3 lety +1

    Thanx you so much for this awesome video, but how many volt is the motor and what’s the voltage on the line coming from the panel ?

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety +3

      it is single phase 220v motor

    • @Savagethehome
      @Savagethehome Před 3 lety

      @@JrElectricSchool I live in the USA and I have 2 panels 277v panel and 120v panel
      Which panel do I connect it to ?

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety

      @@Savagethehome you can connect 277v

    • @harveydeclan8538
      @harveydeclan8538 Před 2 lety

      You prolly dont give a shit but does any of you know of a way to get back into an instagram account..?
      I was stupid forgot the account password. I appreciate any tips you can offer me.

    • @garrettkairo1582
      @garrettkairo1582 Před 2 lety

      @Harvey Declan instablaster :)

  • @mcrogertvvlog8827
    @mcrogertvvlog8827 Před 3 lety +1

    Nice

  • @joew4202
    @joew4202 Před 3 lety

    Can you tell me where I can get these parts at. I want to connect to to plc

  • @smooddawg9166
    @smooddawg9166 Před 2 lety

    Can a bad motor causes the contactor to remain close?

  • @manteshsharma2168
    @manteshsharma2168 Před 3 lety +1

    Super sir

  • @simontirkey7863
    @simontirkey7863 Před 3 lety +1

    Good

  • @MukeshPatel-ul6qw
    @MukeshPatel-ul6qw Před 3 lety +1

    Theory ke sath

  • @abbc1495
    @abbc1495 Před 3 lety +1

    nice

  • @viveksharma1045
    @viveksharma1045 Před 3 měsíci

    ek convaur motor ko start switch ek stop switch,ek emergency stop switch,ke sath el convaur ke last me tray takrane pr convaur stop ho jaye ek limit switch ,condtion h ki convaur jab bhi start kare to on switch se hi ho,esa sld koi bhai banake de sakta h kya/,ek realy use hogi sayad

  • @joshuamariegalila5049
    @joshuamariegalila5049 Před 2 lety +1

    👍

  • @dilipdas5777
    @dilipdas5777 Před 2 lety

    Do I need magnetic contactor for 1 hp motor?

  • @hasanaliozkaya228
    @hasanaliozkaya228 Před 3 lety +1

    hello, thanks for the video. Which animation program did you prepare the video with?

  • @abdulrahman-hz1zg
    @abdulrahman-hz1zg Před 3 lety

    Y did you connect contactor no out to start and stop button between... Could you please explain brother

  • @JawadAli-up2cd
    @JawadAli-up2cd Před 3 lety

    Sir where you takes picture of electric components

  • @abbc1495
    @abbc1495 Před 3 lety +1

    wow

  • @mo2058130
    @mo2058130 Před 3 lety +1

    How do I know what size contactor I need 36 V 800 W thank you

  • @clloyder
    @clloyder Před 3 lety +1

    What apps did you used? Thanks

  • @darwineleydo7071
    @darwineleydo7071 Před 3 lety

    How to connect the overload relay with that diagram. Thank you

    • @darwineleydo7071
      @darwineleydo7071 Před 3 lety

      My single phase motor is 10hp 60A is this applicable?

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety

      please watching this video
      czcams.com/video/m6-s-yGP8q4/video.html

  • @johndoriano4796
    @johndoriano4796 Před rokem

    Master anu po specs ng MC mo? Tnx Nice video.

  • @puneeths7809
    @puneeths7809 Před 3 lety +2

    Sir what is the rating of mcb and magnetic contacter

  • @slfreedom4712
    @slfreedom4712 Před 3 lety +1

    supper video..how to connect devices using this softweare

  • @mchungkom
    @mchungkom Před 3 lety +1

    Sirji, agar explanation kardiya hota toh aur bariya hota

  • @newhindistory3528
    @newhindistory3528 Před 3 lety

    आप कौन सा ऐप इस्तेमाल करते हैं सर

  • @newhindistory3528
    @newhindistory3528 Před 3 lety

    कौन ऐप से डायग्राम बनाते हैं

  • @abbc1495
    @abbc1495 Před 3 lety +1

    nc

  • @dilshadv2492
    @dilshadv2492 Před 3 lety +1

    Oru mcb nine rande out kodukan patumo

  • @kouroshse5876
    @kouroshse5876 Před 3 lety

    I think its better to show first how the control circuits works ... the stop start botton then to the magnetic coik of the contactor... then the power circuit from the mcb to the line 1 line 2 of the contactor then gojng to the motor.

  • @mohd.shaqibkhan3277
    @mohd.shaqibkhan3277 Před 3 lety +1

    Bhai 100 amp ka 4 pole 2NO aur 2NC type contactor lagbhag kitne ka milta hai???

  • @samuelcalderon3807
    @samuelcalderon3807 Před 2 lety

    If my contactor works with 220 volt .. i only feed bye one líne .. in other words i feed only bye A2... the bobine only have one líne

  • @operation2303
    @operation2303 Před 3 lety +1

    How to calculate magnetic conductor size?

  • @dplustv7553
    @dplustv7553 Před rokem

    Schneider Electric Square D TELEMECANIQUE TeSys LC1D12BD

  • @tusharsharma5654
    @tusharsharma5654 Před rokem

    Simulator kon sa ha yi sir

  • @bayuj4ncok
    @bayuj4ncok Před 3 lety

    Why u take no coil?

  • @curato3901
    @curato3901 Před 2 lety

    mas mahirap pa redstone mechanics ng minecraft eh ez lang pala to.

  • @anandasekaran1687
    @anandasekaran1687 Před 3 lety +1

    Can you say about the software ,that you are using ?

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety +2

      filmora wondershare,sony vegas pro,
      adobe after effects,adobe premiere pro,
      adobe photoshop,microsoft office.

  • @technicalinformation6824
    @technicalinformation6824 Před 3 lety +1

    Y kesy. Bnaty ah video kon say app pe bnaty hoo

  • @aruldoss1524
    @aruldoss1524 Před rokem

    தமிழ் வீடியோ போடுங்க

  • @RahulRoy-wp1pm
    @RahulRoy-wp1pm Před 9 měsíci +1

    समझ में नहीं आया

  • @erniegomonit1730
    @erniegomonit1730 Před 2 lety

    What is the meaning of symbol L, N, E in your diagram..?

    • @mylesdickenson9060
      @mylesdickenson9060 Před rokem

      L= live /active /energised, colour= red or brown
      N= neutral, black or blue
      E = earth/ground, green or green and yellow

  • @mdabdurnurtusar7751
    @mdabdurnurtusar7751 Před 2 lety +1

    ভাই কেপাছিটার কি ভাবে লাগাই, ভি ডি ও দিবেন ৫ হ্্জ

  • @newhindistory3528
    @newhindistory3528 Před 3 lety

    App kun sa istemal karte sir

  • @bakiullah4476
    @bakiullah4476 Před 2 lety

    This contackter name

  • @xsmunsifali4958
    @xsmunsifali4958 Před 2 lety

    begart tona na kame por to nahi ky

  • @abbc1495
    @abbc1495 Před 3 lety

    nv

  • @jazz-ys9dl
    @jazz-ys9dl Před 2 lety +1

    Sir i want joint school

    • @JrElectricSchool
      @JrElectricSchool  Před 2 lety +2

      please you can subscribe our channel and joint free.
      Thank you.

  • @raymundmalicdem7228
    @raymundmalicdem7228 Před 3 lety

    Sir yung may overload relay panu po wiring

    • @JrElectricSchool
      @JrElectricSchool  Před 3 lety

      sorry i am not understand your language please tell me Bangla,Hindi,English.
      Thank you.

  • @paulbirch5803
    @paulbirch5803 Před 2 lety

    Music is horrendous. Video is worse

  • @stuffoflardohfortheloveof

    I’m afraid I need to point out an error in your circuit. The very last ‘+’ (live/red) connection you made (3:15) was from contactor terminal 14 to a point BETWEEN the green start (NO) switch and the red stop (NC) switch. It was meant to be the holding/latching part of the circuit. However, because the start switch is a momentary switch as soon as it is released current cannot flow back to the contactor ie it cannot feed the holding circuit (contactor terminal A1). To correct this simply remove and replace by making a direct connection between 14 & A2.

    • @kelargo
      @kelargo Před rokem

      I tried this. It causes a short. The diagram at the end works as desired.

    • @jasonk8936
      @jasonk8936 Před rokem

      Both switches are momentary switches? Don't quite understand " it cannot feed the holding circuit (contactor terminal A1). To correct this simply remove and replace by making a direct connection between 14 & A2." Care to explain a little?

    • @stuffoflardohfortheloveof
      @stuffoflardohfortheloveof Před rokem +1

      @@jasonk8936 Apologies, i've just rewatched the vid and cannot understand why i wrote that (TBH i cant even remember writing it)🤔. I'll delete my original to not confuse anyone else 👍

    • @stuffoflardohfortheloveof
      @stuffoflardohfortheloveof Před rokem +1

      @@kelargo Apologies, i've just rewatched the vid and cannot understand why i wrote that (TBH i cant even remember writing it)🤔. I'll delete my original to not confuse anyone else 👍

    • @jasonk8936
      @jasonk8936 Před rokem

      @@stuffoflardohfortheloveof No worries. I too dont remember anything anymore after the vax

  • @abbc1495
    @abbc1495 Před 3 lety

    good job