Air Conditioner Powered by Micro-Air EasyStart with Genmax GM900iED Portable Generator

Sdílet
Vložit
  • čas přidán 22. 07. 2024
  • UPDATED MARCH 2023: Micro-Air revised its sizing to optimize the performance of EasyStarts installed on Home HVAC units. The change occurred subsequent to the posting of this video.
    You can find your proper EasyStart model using the BTUs of your unit in the Company model selector tool here à www.micro-air.com/tools/easys....
    EasyStart 368-X72-Blue 4 to 6 tons
    EasyStart 368-X48-Blue 2 to 3.5 tons
    EasyStart 364-X36-Blue 1 to 1.5 tons
    Thank You for watching!! Subscribe / Like
    In this video, I demonstrate how I can power my house, including the air conditioner with a generator and an EasyStart.
    EasyStart™ is a one-of-a-kind, custom-developed soft starter for single-phase motors like those used in the home and commercial contexts. It employs a 4-part start ramp sequence that is self-optimizing, resulting in the lowest possible start-up current. EasyStart can deliver a start current reduction of up to 75% of a compressor's LRA (locked-rotor amperage). EasyStart is the perfect solution that allows an air conditioner or refrigeration compressor to operate on a generator, inverter, or limited utility power when it would otherwise not have functioned. It can also be applied to air compressors and fluid pump motors.
    Micro-Air EasyStart - amzn.to/3fDcazE
    Additional Cable for Easy Start:
    EasyStart comes with 4 cables with 4 colors (same colors are recommended, not mandatory)
    10 AWG THHN wire (white) - amzn.to/3E2IlSC
    10 AWG THHN wire (brown) - amzn.to/3sZVt4J
    14 AWG THHN wire (black) - amzn.to/3hjIXdP
    14 AWG THHN wire (orange) - amzn.to/3WC9YsL
    Metal Junction Box - amzn.to/3DIyEXY
    Magnetic Hooks - amzn.to/3TbMk3E
    Mixed Electrical Quick Disconnect Insulated - amzn.to/3UwDZsa
    ELECTRICAL CONDUIT AND FITTINGS AS NEEDED
    GENMAX GM9000iED - amzn.to/3QmedVL
    Magnetic Oil Dipstick - amzn.to/3St2aXd
    Magnetic Oil Drain Plug Bolt - amzn.to/3SrXocj
    Low Profile Oil Drain Pan - amzn.to/3QwGoAZ
    Reliance LL550C 50 Amp Connector CS6364 - amzn.to/39ODlEZ
    Reliance 50 Amp Flanged Inlet 14-50FP - amzn.to/39Q0jvd
    Nassau SOOW SO Cord Power Wire 6/4 35 FT. - amzn.to/3OFQAGB
    Reliance Controls Power Inlet Box 50-Amp - amzn.to/3bsFh6y
    WELLUCK 50 Amp Power Inlet Box - amzn.to/3Ng7Q4l
    CHAPTERS::
    0:00 Setup Generator
    0:54 Intro
    2:04 A/C LRA
    2:50 EasyStart Overview
    4:15 Recap
    5:37 Closing
    -----------------------
    #Generator #Inverter #Inlet
    -----------------------
    ‪@dinkingofficial7521‬ ​
    ‪@MicroairNet‬
  • Jak na to + styl

Komentáře • 37

  • @pinballguru
    @pinballguru Před 14 dny +1

    I bought 2 units as we have 2 AC units. They are all the same now . I loved the video. The enclosures are so much better . Easy to look for issues versus taking cover off. Well Done.

  • @PRAISEFATHERYA
    @PRAISEFATHERYA Před 12 dny +1

    Hey you're the best you explained it the best possible way. Thabk you for your hard work. Because I always wondered how am I going to start my AC but now i know.

  • @projectswithjw
    @projectswithjw Před 6 měsíci +2

    I really like the soft starters mounted inside the enclosures 👍

  • @miguel.a.lefebre
    @miguel.a.lefebre Před rokem

    Absolutely great video. Thanks!

  • @mrteausaable
    @mrteausaable Před rokem

    Update from Micro-Air, I contacted them and they told me for my 2 tons Compressor to use the EasyStart 368-X48-Blue for more efficient. No longer use 364 unit or smaller. Thanks for the video.

    • @JavierRivera
      @JavierRivera  Před rokem +2

      Yes. They changed their parameters. 364 still works for 2tons but according to them now 368 will be more efficient.

  • @stelon7615
    @stelon7615 Před rokem +1

    As always great informative video Javier, thank you! Having the two EasyStarts together in a junction box was a great idea! Micro Air's tech support is outstanding when it comes to run you through the whole installation process if you bump into any issues.

    • @JavierRivera
      @JavierRivera  Před rokem

      Thanks. I didn’t like the idea of having the easy start exposed. Now. The only problem I have not resolved is that I need to add a waterproof wire connection diagram for any technician that comes to repair the ac units. So he knows what are those 4 cables and how are connected.

    • @stelon7615
      @stelon7615 Před rokem

      @@JavierRivera yes, you have to. It happened to me recently and I wasn't home. The A/C guy asked my wife if he could disconnect the "box" that was connected to my 5ton unit to "run some tests" and he never wired it back🤬

    • @JavierRivera
      @JavierRivera  Před rokem

      @@stelon7615 Well, for now, I printed 2 wiring diagrams and put them with the air handler unit paperwork in the front of the unit. Eventually, I might need to put 1 of those diagrams in a ziplock bag and place it in the outside units and maybe in the junction box.

    • @mrteausaable
      @mrteausaable Před rokem

      Why this unit cost over $300 where l can get about price of new compressor?

    • @JavierRivera
      @JavierRivera  Před rokem

      This is not only to prolong the life of your compressor. The main purpose is to reduce the amount of rushed Amps needed to start the condenser unit so you can use a Generator to power the unit at your home.

  • @tsx6142
    @tsx6142 Před rokem

    I have your exact same CHAMPION generator and I changed it to Propane myself with a kit. I never even ran it with gas one time. I bought and filled four (4) 50# propane tanks so I have a pretty long run time and I don't worry about the gas going bad. I need to get that MicroAir so I can run my 4Ton unit. What is the size of your long cable? I have a similar cable that I built myself and it's a #8/4 SOOW about 115ft.

    • @JavierRivera
      @JavierRivera  Před rokem

      Hello. It depends of the easystart model. You could order the extra cables from micro-air by contacting them by email so you have the same colors. If not here are the sizes.
      EasyStart 364
      14awg x 2c + 10awg 2c
      EasyStart 368
      12awg x 2c + 14awg x2c

  • @pinballguru
    @pinballguru Před 14 dny

    Can you see both units running on the APP? What is the best connector if I splice the wires and buy the same as you show .

    • @JavierRivera
      @JavierRivera  Před 14 dny

      @@pinballguru The app will detect the signal when the AC is running. So if you want to connect to the 2nd ac you will need to stop the 1st ac and start the 2nd one and you will see that the app will see it. Best connectors. WAGO connectors.

  • @user-dc6mg2rk8p
    @user-dc6mg2rk8p Před 10 měsíci

    How did you extend the wires? Splice? Or did you go inside the box and put on longer wires?

    • @JavierRivera
      @JavierRivera  Před 10 měsíci

      I contacted micro-air and I bought 15ft of cable from them then I Spliced the cables. The cables that comes with the Easystart are welded inside the box.

    • @user-dc6mg2rk8p
      @user-dc6mg2rk8p Před 10 měsíci +1

      @@JavierRiveraOk thanks. I contacted them and they told me they don’t sell the cable. But they said to buy the wires, splice and I guess I could use a flexible liquidtite conduit. Thanks.

  • @AgentOffice
    @AgentOffice Před rokem +1

    Fun

  • @user-dc6mg2rk8p
    @user-dc6mg2rk8p Před 10 měsíci

    If you have 2 a/c’s set up, how will you know which Bluetooth is reading which a/c?

    • @JavierRivera
      @JavierRivera  Před 10 měsíci

      I will know depending of which A/C is running. Something I start one A/C check the app and then stop that unit and start the other one.

    • @user-dc6mg2rk8p
      @user-dc6mg2rk8p Před 10 měsíci

      @@JavierRiveraok thanks. I’m going with a setup like you have, since I have a 4 ton and a 2.1/2 ton. Just ordered the electrical box. Going to splice the wires too. Thanks for your advice.

  • @pinballguru
    @pinballguru Před 12 dny

    Hi Javier, is It's mounted in a water proof box with it closed. I cant seem to connected to the app sitting in my living room. Do I have to be next to it for the app to connect>? is the metal door preventing it from connecting? It worked while we were installing. Weird.

    • @JavierRivera
      @JavierRivera  Před 12 dny +1

      @@pinballguru that is correct. The easystart waterproof enclosure prevents the Bluetooth signal from going out. So. Yes you have to be close to the easystart.

    • @pinballguru
      @pinballguru Před 12 dny

      @@JavierRivera maybe I can drill small hole on the side and that should work.

    • @JavierRivera
      @JavierRivera  Před 12 dny

      @@pinballguru I would not do it, will store moisture.

    • @pinballguru
      @pinballguru Před 12 dny

      @JavierRivera bit the micro is sealed and people mount in side and on the outside. Just thinking .

  • @kevincarlin3080
    @kevincarlin3080 Před rokem

    Is it Genmax 900 or 9000?

  • @danray9744
    @danray9744 Před rokem

    Just because that Generator has a 50amp Plug Don't Mean i can produce 50amps that GM9000IED is rated at 9000W Max Surge & 7600watts Running Amps So 9000 divided by 240volts = 37.5 Max Amps that's why it has a 50amp plug they don't make a 40 amp plug Just a 30 amp & 50 amp , so at 37.5 amps the 30amp plug would be underrated so they had to put a 50amp plug But it still will only Produce 37.5 amps NOT 50 amps 7600w = 31.6 Amps @240v , To get 50amps @240volts you will need a 12,000watt Generator

    • @JavierRivera
      @JavierRivera  Před rokem +1

      In reality is more than 50amp. 75amps at 9000w starting watts. Running watts is 7600w. Per leg is 3,800. 3,800 divided by 120 = 31.6amp per leg. Each leg is 120v with 31.6 amp for a total of 240v with 63.2amp at 7600w Running watts.

    • @teamhall71
      @teamhall71 Před 11 měsíci

      @@JavierRivera You don't get double the power just because you have 2 legs, each leg is out of phase with the other. Your generator has 7600 running watts at 240v, that is 31.6A. It may be able to tolerate a short spike twice that for a millisecond but your generator is not producing 63A continuous. As the other poster stated, the rating of the plug is 50A and has nothing to do with the output of the generator.

  • @brendandonahue6104
    @brendandonahue6104 Před rokem

    LRA stands for Lock Rotor Amps. It does not mean this is what it takes to start the compressor and fan. That in rush what pop your breaker.
    RLA is your Run Load Amps. Your math is off.

    • @JavierRivera
      @JavierRivera  Před rokem

      Hi, I know but is a close number that the amps will spike for a second that is why I used that number instead of measuring it with a clamp meter. if you need exact numbers to be able to make a decision let me know and I can get it for you.