Calibrating IR gun

Sdílet
Vložit
  • čas přidán 10. 07. 2019
  • Calibrating IR gun.

Komentáře • 21

  • @johnny0454
    @johnny0454 Před 2 lety +33

    That is not calibration. The emissivity setting is for different materials that you would be measuring, for example, the infrared emissivity of skin is around 0.98, polished steel 0.10, copper 0.60, etc. The emissivity of water and ice is going to be nowhere near the emissivity of say a wall, or steel. You set the emissivity for the material to be measured. If you set the emissivity to give you the correct temp for water, that is the only material that will give you a correct reading, it will be wildly incorrect for any other material, like skin, wood, or plastic. You can google emissivity charts for different materials so that you can set the emissivity correctly for each material to be measured.

    • @clone1137
      @clone1137 Před rokem

      Wow this was really insightful and interesting, thank you for taking the time to share!

    • @JesseFlannery
      @JesseFlannery Před 11 měsíci

      Thanks. This info is going to help me a lot. I am trying to get infrared thermometers into a healthcare setting. 😊

    • @ewerson18
      @ewerson18 Před 8 měsíci

      How can I calibrate?

    • @JesseFlannery
      @JesseFlannery Před 8 měsíci

      @@ewerson18 it says look up the emissivity chart for whatever you are measuring. My guess to calibrate you would set the emmisivity to water and make sure it calibrates to 32 F or 0 C for ice water then go from there changing the thermo emissivity chart to other things you would want to measure.

    • @ewerson18
      @ewerson18 Před 8 měsíci

      @@JesseFlannery hey Jesse, thanks I will try that. My sensor is measuring above what really is, perhaps it's just some dirt in the lens, I need to test it.

  • @thomasr1051
    @thomasr1051 Před 2 lety +3

    Ok well I learned a lot from the comments and from your video for how to calibrate for water

  • @YahwehisGod
    @YahwehisGod Před rokem +2

    Another thing no one is mentioning is to calibrate, you need a standard. That standard also needs calibration. If you don't have a calibrated standard, you don't have any calibration.

  • @AdiGeorgescu22
    @AdiGeorgescu22 Před 4 lety +8

    that's nnot calibration... you do not show how to calibrate. Emisivity depends on the material. If the reading is off.... how do you calibrate (adjust) the thermometer?

  • @Christianlvm22
    @Christianlvm22 Před 3 lety +2

    No... Any surface need a different EMS value

  • @heronzegarra3765
    @heronzegarra3765 Před 3 lety +1

    I think that this device can not support calibrate

  • @aliyavloge2476
    @aliyavloge2476 Před rokem

    Reset option

  • @rabeHH
    @rabeHH Před 2 lety

    TOP

  • @riverman4798
    @riverman4798 Před 3 lety +1

    You cant get real reading shooting fluid on the surface

    • @johnny0454
      @johnny0454 Před 2 lety +2

      You can if the emissivity is set correctly for the particular fluid. Emissivity must be set for each different material you are shooting, you can look up emissivity tables for different materials online. Emissivity varies wildly based upon how reflective or light-absorbing a particular material is. Polished steel is around 0.10 while skin is around 0.98.

    • @johnny0454
      @johnny0454 Před 2 lety +2

      More info and a demonstration: czcams.com/video/Nr_ziSlb4Sw/video.html