Structural Strengthening & Stabilization - Beams and Slabs

Sdílet
Vložit
  • čas přidán 14. 07. 2024
  • Structural Strengthening & Stabilization of beams and slabs, strengthening of walls and columns, flexural strengthening, shear strengthening, repair and strengthening of joints

Komentáře • 27

  • @karthiassociates3146
    @karthiassociates3146 Před 3 lety +1

    Very useful lecture. Regards.

  • @suparnagoswami3906
    @suparnagoswami3906 Před 3 lety +2

    It was really helpful 🙏

  • @saithwickramasinghe1604
    @saithwickramasinghe1604 Před 3 lety +1

    Very helpful info

  • @Madankumar-hz4dv
    @Madankumar-hz4dv Před 3 lety +2

    I was waiting for this from many days. Thank you so much.

    • @yourfriendlyneighbourhood-9108
      @yourfriendlyneighbourhood-9108 Před 3 lety

      @Noe Axton very ethical for you. why would you tempt people...

    • @uriahallen7212
      @uriahallen7212 Před 2 lety

      you all prolly dont give a damn but does someone know of a method to log back into an instagram account??
      I was dumb lost the account password. I appreciate any help you can offer me

  • @gyayakbhuta
    @gyayakbhuta Před 3 lety +1

    It was really helpful

  • @commonerIndian
    @commonerIndian Před 2 lety +1

    great.. thanks

  • @haykalzaky7731
    @haykalzaky7731 Před 2 lety +1

    thankss

  • @mr.kpadmanadham550
    @mr.kpadmanadham550 Před 2 lety +1

    I may suggest to use shear studs to improve bond between existing and new conrete

  • @mohamedfaris1394
    @mohamedfaris1394 Před 3 lety +1

    it was really helpful

  • @khawyang5046
    @khawyang5046 Před měsícem

    This is very interesting, however, where can we find the reference design for those strengthening work?

  • @vaenu9993
    @vaenu9993 Před měsícem

    After rusted bars slab renovation may I use H type iron beams to support the slab?

  • @mr.kpadmanadham550
    @mr.kpadmanadham550 Před 2 lety +2

    Sir u given useful presentation. I have few questions. 1.How could u ensure compatability between the existing RCC and retrofitted Ultra high performance concrete.2 What is the ductility of retrofitted system that means increase or decrease. 3.why i asked this questions are before strengthening of integrated elements we must ensure safety of integrated connection system such as beam.column joint. R u done any experimental work in this lines???Thank u for presentation...

  • @madhucivil7302
    @madhucivil7302 Před 7 měsíci

    • @madhucivil7302
      @madhucivil7302 Před 7 měsíci

      Sir,
      It is very useful information which we are going to cast the retrofitting works at site.

  • @noproblem6865
    @noproblem6865 Před rokem

    Additional concrete and reinforcement on existing slab will apply more load on the existing slab???

  • @agustinussiahaan2432
    @agustinussiahaan2432 Před 2 lety +1

    You have no picture's or drawing's number. Your last drawing has an error. On the axial drawing, the teflon is placed under the steel, while in the cross sectional drawing, the teflon is placed above the steel. Please confirm. Thank you.

  • @billomalley1168
    @billomalley1168 Před rokem

    20:14

  • @vishvasmeshram6094
    @vishvasmeshram6094 Před 2 lety +1

    Is it possible

  • @medoghany6882
    @medoghany6882 Před 3 lety +2

    I benefited from your interesting explanation
    Please, I am asking you a favor
    I am a university student and there is research I am doing on this topic
    Can you help me by giving me a copy of this presentation ?

  • @coolgamer9429
    @coolgamer9429 Před 2 lety +1

    What was the thickness of the plate placed under the beam?

  • @saithwickramasinghe1604
    @saithwickramasinghe1604 Před 3 lety +1

    Very helpful info