Finding Why Compressor Isn't Starting? Fault Surprised Me!!

Sdílet
Vložit
  • čas přidán 6. 08. 2023
  • Are you facing the frustrating issue of your mini split AC compressor not starting? Don't worry; we've got you covered! In this video, we dive into the common reasons behind this problem and unveil a surprising fix that will keep your AC running in no time. Join our expert team as we guide you through the step-by-step troubleshooting process. We'll explore potential issues such as faulty wiring, capacitor problems, or a malfunctioning thermostat. We aim to help you identify the root cause and provide an effective solution. But here's the twist - the fix we reveal might surprise you! It's a simple yet often overlooked solution that can save you time, money, and unnecessary repairs. You won't believe how easy it is! Whether you're a DIY enthusiast or a homeowner looking to better understand your Air conditioner system, this video is for you. Our friendly and knowledgeable team will ensure you feel heard and provide concise answers to your questions.
    Don't miss out on this valuable troubleshooting guide! Hit that play button, and get your mini split AC compressor back in action. Remember, a cool and comfortable home is just a few steps away! Subscribe to our channel for helpful tips and tricks to keep your HVAC system running smoothly. Together, let's conquer the challenges of AC maintenance and enjoy the comfort we deserve.
    ******************************************************************************
    Products You Might Be Interested in buying and sharing with your friends. Thanks!
    Multimeters
    NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
    ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
    Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
    Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
    UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
    ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
    TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
    MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
    ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
    ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
    Thermal Camera
    UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
    TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
    Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
    Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
    Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
    TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
    Soldering Wires
    10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
    0.8mm/1.0mm 50g Lead-Free Solder➡️ s.click.aliexpress.com/e/_DDn...
    0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
    200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
    8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
    250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexpress.com/e/_Deu...
    Vacuum Pump
    18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
    VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
    Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
    VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
    Mani Fold Gauge
    Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
    R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexpress.com/e/_DeB...
    Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
    500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
    HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexpress.com/e/_DBi...
    Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
    MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexpress.com/e/_Dkg...
    Soldering stations
    RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
    JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexpress.com/e/_DFz...
    GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
    JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
    ******************************************************************************
    💡 Support Us On Patreon 👉 bit.ly/3vMga6S
    💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
    Social Links
    💡Facebook 👉 / forevertech3
    💡Instagram 👉 / forever_tech1
    💡Twitter 👉 / forevertech3
    #ac #hvac #compressor #airconditioner #compressor #motherboard #repair #fix

Komentáře • 28

  • @hamadaHamed-vl6kq
    @hamadaHamed-vl6kq Před 11 měsíci +2

    فنان فنان فنان يا احلى هندسه

  • @babaolowo35
    @babaolowo35 Před 11 měsíci +1

    THANK you

  • @ErsinGokay
    @ErsinGokay Před 12 dny

    excellent tech stuff

  • @trollteam4422
    @trollteam4422 Před 11 měsíci +1

    Does the orientation of the condenser coils matter? Can they be either vertical or horizontal?

  • @Jason-wc3fh
    @Jason-wc3fh Před 20 dny +1

    The compressor is a 3 phase motor. You had two windings with very accurate resistance readings of 3.8 ohms and one winding was out of spec at 4.3 ohms... Isn't that an indication that the compressor winding is no good? That difference also leads to different amperage readings across the legs when running and the compressor will likely heat up with running time. This is likely the reason the terminals melted on the compressor connection.

  • @Ghedi1965
    @Ghedi1965 Před 11 měsíci +1

    Thank you

  • @Bass.Player
    @Bass.Player Před 11 měsíci

    I have seen this before on central units. I used large gauge replacement wire to serve as a heat sink, no further problems'

  • @abdalqadr1
    @abdalqadr1 Před 17 dny +1

    ❤❤❤❤❤

  • @Abdulquariosimea-el1rr
    @Abdulquariosimea-el1rr Před 10 měsíci +1

    Wonderful video.
    Pls I wish to learn tutorial about the indoor and outdoor motherboard

  • @user-cv5qr8fk4i
    @user-cv5qr8fk4i Před 17 dny +1

    請問有中文字幕嗎?

    • @forevertechenglish
      @forevertechenglish  Před 17 dny

      是的,这个视频添加了中文字幕,你可以看看。如果没有,请告诉我,我会为你添加。

  • @nanibelloua4962
    @nanibelloua4962 Před měsícem

    How to make analyzer

  • @Hi-levels
    @Hi-levels Před 10 dny

    can you change the fuse in inverted AC compressor?

    • @forevertechenglish
      @forevertechenglish  Před 10 dny

      You mean to say a fuse inside the compressor? I don't get which fuse do you mean?

    • @Hi-levels
      @Hi-levels Před 10 dny +1

      @@forevertechenglish there is no Fuse inside the inverter compressor for ourdoot unit?
      My aux unit doesnt start at all for the outdoor part. I have no idea

    • @forevertechenglish
      @forevertechenglish  Před 10 dny +1

      @Hi-levels There must be a fuse on the circuit board of the outdoor unit. Not on the compressor, check the circuit board

  • @ballesteros614
    @ballesteros614 Před 9 měsíci

    I have a unit that is cooling but not blowing out sufficient air and not cooling the apartment, what can be the cause of this?

    • @forevertechenglish
      @forevertechenglish  Před 9 měsíci

      The coils could be dirty, the dirty coils make the air not to blow properly

  • @Meerschaut87
    @Meerschaut87 Před 26 dny

    Hi Forever Tech English,
    Thank you for explaining the error on the split unit.
    if i turn on the AC unit it starts working for about 10 minutes, after that it goes into error P4 and the compressor stops.
    I have done all test about the compressor wiring and tested the body short, everything is fine (also the compressor works for about 10 minutes, even the pipe starts getting ice on the surface and the indoor unit start to give cold air).
    I have measured the IPM and it gets +300V on the positive pin and 160V on the U, V and W Pin.
    Once the unit goes into error mode, the U, V and W Pin only gets a 23V.
    I have tried measuring the IGBT as you showed in this video: czcams.com/video/4IoV8I-pcT8/video.htmlsi=DmGR5cOUEwL9e8AH
    - Negative probe on Base (Gate) and Positive on Emitter i get 0.546V
    - Positive on Gate and negative on Emitter i get 1.083V
    - Negative on Emitter and positive on Collector i get OL
    - Positive on Emitter and negative on Collector i get 0.464V
    - Negative on Gate and positive on Collector i get OL
    - Positive on Gate and negative on Collector i get 1.372V
    Is this IGBT broken or is it still oke?
    what else could give me this error while i don't see anything else wrong or broken?
    Thanks alot.
    With friendly greetings

    • @forevertechenglish
      @forevertechenglish  Před 26 dny

      The UVW pins should have 15 volts not 160 volts

    • @Meerschaut87
      @Meerschaut87 Před 26 dny

      @@forevertechenglish That is correct, i hadn't seen the dot between the 6 and 0
      Now i measured 22V on every pin.

  • @erichertsens
    @erichertsens Před 11 měsíci

    I have a question, unrelated but might be of interest, lets say i have a string of solar panels wirh a steing voltage of 300V, is there a way to just inject that power just past the bridge rectifier? Food for thought

    • @forevertechenglish
      @forevertechenglish  Před 11 měsíci

      Well, that's something cool to do. I will have to figure out and experiment with it. Then we can get to a conclusion.

  • @user-tq7er5ug3g
    @user-tq7er5ug3g Před 4 měsíci

    E
    what problem ?