4 Concrete Test Live Practical | Slump Test | Cube test | Temperature Test | Rebound hammer Test
Vložit
- čas přidán 6. 07. 2021
- 15 Mistake in House construction
• 15 Biggest Mistakes du...
15 Technical Term for civil Engineers
• 15 Technical Every civ...
Official Website Civil Site Visit
civilsitevisit.com
Daily New Job Links
civilsitevisit.com/recruitment/
WHATSAPP GROUP
chat.whatsapp.com/Kvn5i0GGzjp...
( TELEGRAM GROUP FOR CIVIL ENGINEERS )
t.me/joinchat/i84Oy3K0wqgzMjU1
t.me/joinchat/zwE9MYXIdgY5OWY1
( TELEGRAM GROUP FOR JOB UPDTAE )
t.me/joinchat/AzzpD2BS3qhmZjZl
( OUR OTHER CZcams CHANNEL )
1. For Job Update
/ @civilsitevisitjobsupd...
2. For Business Idea
/ @businesskaadda12
3.Civil Engineer Sharma Ji ( Basic of civil Engineering )
/ @civilsitengineer
4.Pareeksha ( Job & Exam Preparation )
/ @civilengineerintervie...
10 Most watched Video of ( CIVIL SITE VISIT )
1. Tile or marble Flooring
• मार्बल लगाये या टाइल |...
2.How to decrease construction cost of House
• घर बनाते समय इन 5 बातो...
3.Construction Cost of 1000 Sqft House
• Construction cost of 1...
4.Parapet Wall Cheap & Best Design
• Parapet wall two Best ...
5.Wall Dampness Treatment
• Wall Dampness Treatmen...
6.Marble or Tile Flooring
• Marble or Tile ? which...
7.Cracks in wall repair
• घर की दीवारों में क्रे...
8.Mistake in House Construction
• घर बनाते समय इन 8 बातो...
9.1000 sqft House Material Quantity
• 1000 sqft का घर बनाने ...
10.ACC Block Vs Red Brick
• 1000 sqft का घर बनाने ...
CONTACT DETAILS
✔Email Id for Business Enquiry - rs140565@gmail.com
✔Twitter: VisitCivil?s=09
✔Facebook Page: / 100041543491213
✔ LinkedIn: / rahul-sharma-66324a215
✔Instagram: / civil_site_visit
✔Tumblr: / civilsitevisit
For Business Enquiry
7006672812 (Note :- Only WhatsApp )
Disclaimer - This video is for educational purpose only. Copyright
Disclaimer Under Section 107 of the Copyright Act 1976, allowance is
made for "fair use" for purposes such as criticism, comment, news
reporting, teaching, scholarship, and research. Fair use is a use
permitted by copyright statute that might otherwise be infringing.
Non-profit, educational or personal use tips the balance in favor of
fair use .
#ConcretetestLivepracticl #FreepracticalTrainin
Tremendous job you are doing sir .... Keep it sir
Explained very nicely.
Slump test is done to test water cement ratio which has direct impact on the design strength of concrete. The reduction in height after the cone is removed depends on the type of concrete vis a vis design strength. For example concrete of M20, M25, M30 etc have different reductions in height after the cone is removed.
Amazing video sir, most knowledgeable I can guarantee. Thank you so much. Keep providing us such valuable content. Thank you sir.
Very nice sir prectical video dekh kr bhut kuch sekhne ko mila
Again Thank you so much🙏
Very nice
Thank you brothet for giving practical information👍🏻🤝🏻🙂
Very nicely carried out practical concrete various tests and explained to understand even dull student. Best video
F uk v
For slump test, number of layers is 3 and for each layer the tamping should be 25 times. Care should be taken that while tamping 2nd layer it must not penetrate 1st layer and same for 3rd layer, this test should be completed within 2 min, Ref: IS 1199(part-2):2018 (but your video is informative, keeping growing good luck)
Test taken to make a video l don't think in india any bulider will waste time in such tests concrete comes pour it work done go home that is regular practise time pass video
Now the standard has been change. You must penetrate the previous layer by 1 inch. The way he test the slump is bulshit. Slump must be fill in 3 layer. 1st layer 7 cm. 2nd layer 16 cm. 3rd layer 30 cm. Tamping in each layer must be 25 time.
I agree with you
As per IS code 1199 2018.......We fill the slump cone in 3 layer of 25 time stroke each...The hole procedure should be done within the 3 min time frame
Right
I also noticed same he said 4 layer 25-28 tamping Totally wrong.
And again said 35 tamping in cube filling, he doesn't know any thing
@@atoullshukkla5625 25 time is right
I can proof
28 days ka calculation wrong hai 30*99/100
Very nice u r sharing greatful knowledge
Nice Explain & very informative video 👌
Great effort sir... 🙏🙏
Apka jo KN/Nmm2 ka volume ata hai usko grade of concrete se divided karo usse pata chalega ki kitna % hai
........
adhoora gyan nhi please, KN/mm² ka volume? ye kya cheez hoti hai yrrr
value likho typing error mtt kro boht freshers isi me confuse ho jayenge
best valuable civil engg site technical knowledge
Very helpfull question
Thanks For The Awesome Content Appreciate From Pakistan
MASS Scientific Sales Mr. Mahipat is very good work
Thnks for this type of video sir👍
Bhut hi badia video h Sir G.👍
Very informative video sir
Thankyu so much sir ji👏👌👌Mene to apke ye test ke video pahle dekhe the aek aek krke lekin aaj fir se revision ho gaya sirjii superb plz sir or video banao jisse hame pura knowledge mil ske 🥰🥰👌👌👌🌷🌷🌷
1 sariya Fitter+ 1 helper = _____ Kg.
1 Carpenter+ 1 Helper= ______ sqm.
8 ghante Ki Job me.
Kitna Productivity Hota he practically.
Most useful video 👍
Very helpful Video for freshers sir thanks for making this.....these three test are very very important for civil engineer bring some more videos 👍
amazing video...very interesting
So important video ❤️❤️
Jaldi se jaldi 1 million hoga
22:25 Actually 7 days me 67% strength and 14 days days मे 87% strength achieved होनी चाहिए according with IS code 🙏
Which IS code
Apne konse IS code me dekha
Sir bahot maaza aa raha h aap ka video dekh kr k
Thnkuu for giving knowledge concrete testing
Wonder full information
Very helpful
Very Nice..thanks
Please upload this type of more videos
Hello Assalamualaikum good to see this video love it ...
Excellent news
As per BSEN or ASTM for the slump testbitz only 3 layers...BSEN its says equal hight of layers,ASTM its says equal quantity for layers
Nice video very helpful
Thanks sir ji..
The slump test is considered failed as per bs when the concrete collapse. The concrete is too watery.
Desired values are between 40 and 80 unless it's a pump mix with extra cement.
The method for raising the cone is inappropriate, he should lift the cone from a higher or standing position.
Anyway good initiative to show test on site. Kudos
Thank you 💕
as per new amendment slump cone test also done in 3 layes
Very good job sir
Best information
Best ever vedio
Nice information sir
Very useful
Great👏👏
🙏 aapka bohot aabhar🙏🙏🙏
Informative
Nyc work sir
love you brother thank you
Nice video sir
Very nice sirji
Thanks for this amazing content,
czcams.com/video/isWVxNUfpiU/video.html
Practical dekh kar confidence bad gya sir
Aa a
thank u 🙏🙏🙏🙏
Thankyou so much Sir
Thank you sir❤
Thank you
Vah sir
Love you from devbhumi dwarka ❤
czcams.com/video/sJ7bp_fAW74/video.html
Hyy
ASTM standard as per 3 layer not 4 layer flings slump cone also lifting slump cone within 5-+2 second asper ASTM
Cube should be filled in 3 layers and slump cone should be filled in 4 layers
@@logiclessmind1525 please let me know standard?
Thanks sir
Pillars are already constructed upto base level.but sudden shortage of money had kept the construction work on suspension for five months. Do u think it will damage the bar that are open from the pillars
Cement wash the exposed rebars including stirrups to prevent formation of rust. Rust is very dangerous as there won't be proper bondage with the concrete if the rebars have become rusty.
Chemical coat for rods will be added advantage
Very good
so good
Nice sir jiiii ❤️
Nice video
Sir concrete mix design se video banaye plz
Thanks🙏🌹❤
Ok plz may you share design mix of m30
At 21:32 jo 22.5 hai wo metre me hona chahiye kyuki 150mm*150mm=22500mm ata hai aur isko metre me convert karne pe ye 22.5metre ho jata hai.....aur 600kilo N hai ya only Newtown? Bhai mujhe kuch jagah calculation explaining me error laga hai...
Good 👍
Sir plz ek video brick test ka bhi or tiles ka bhi .waiting for positive response
Which type of rod should be used for tamping in case of slump test?
Tamping rod...
Sir water level kaise krte hai..
Floor ko up ya down Krna ho..
And floor slope kaise dete hai..
Theory video banao sir...
Plz Plz plz sir
Thanks u sir
👍👍 job 💪💪
Sir after how many days should we check rebound hammer test after pillar casting ?
rain water harvesting par banaiye please
Thx
Nw concrete filling layers has changed...ne it's 3..nd cube tolrance should b 150+-0.2
1 sample pe 3 specimen ready kiya jaata h na..???
Keep it up
Thanku sir
Good 👍👍👍👍
My friend i'm not engineer but I know about concrete because i'm also did this work in kuwait international airport so I want a job
Please, please Slab ke vibration ke bareme datail me video banaye, slab ke size ke according standard vibration kitna hona chahiye oh commen people vibromeeter application se kaise count kare yeh bataye, mera 10x12 ka living room hai usme vibrometer se ek standard football ko 6ft hight se chhodne se 2.5 mm tak ka vibration show karta hai (6ft se chhodne se, na ke patakne se ) toh kya yeh sahi hai?flat new hai
Make video on pqc
good
Bhai QA QC or IBC standards pa b video bnao plz
Sir ultrasonic ka bhi video
Good
Nice
Sir, thermometer ka concrete inserting time k liye kya refrence code h ???
Bt sir As per morth 5th revision tempt is between 25 to 30 if exceeds 30 thn use cold water or ice bt u told in your vedio max temperature 35..please clear
Sir please batiya roof may bend ayga Gaya bataiye abhi Kya
Cement ke grade par bhi nirbhar karta hai na sir
Engineering👨🔧 key bahut video🎥 hain 😇😇😇
Apni bhasha ki baat hee kuch aur hain😇😇😇😇😇
jittaa 4 saal me nhi pdhaaa uttnnaa 40 min me btaadiyaa sir aapne or site construction vaale ques. laauyee sir ap 🤗🤗🤗🤗
🖤