Keurig K-Supreme Won’t Turn On, How To Reset Thermal Switch For No Power Issue.
Vložit
- čas přidán 24. 07. 2024
- In this video, I’m trying to restore life to a Keurig K-Supreme coffee maker that died during a descale process. This model is pretty well known for tripping the thermal protection device inside which cuts all power to the machine. I’ll cover the steps on how to reset this switch to restore power to the coffee maker. I was hoping to get lucky on this one, but we later discover that this machine has additional issues.
Video Timeline:
00:00 - Intro
01:00 - Disassembly
06:57 - Testing & Resetting Thermal Switch
09:30 - Reassembly
11:41 - Testing/ Outro
This video is for entertainment purposes and is not intended to replace written installation instructions, safety guidelines, and common sense. Please make sure to wear the appropriate safety gear when performing any repair. Finally, exercise EXTREME caution when working on electrical appliances, making sure that they are disconnected and powered down before working on them. - Jak na to + styl
So glad I found your video. Once I finally got the case off, reset the thermal switch and reassembled the case my unit works fine. The case on my unit actually is several parts which come off in sections. Thanks again.
Worked!!! Thanks! greatly appreciate it.
Great to hear you’re back brewing, happy I could help!
Thanks! This saved me from buying a new brewer.
Thank you very much, that was very helpful. I think the two lights are flashing because it isn't finished its descale cycle.
Thanks - that did the trick...until next time :)
Thanks for the helpful breakdown! Straight forward advice with tips on how to get the Keurig apart and working again. The keurig works like a charm again after resetting the thermal switch.