Video není dostupné.
Omlouváme se.

Calculate forces that restraints must resist to prevent lateral torsional buckling of steel beams.

Sdílet
Vložit
  • čas přidán 14. 08. 2024
  • If you like the video why don't you buy us a coffee www.buymeacoff...
    Our recommended books on Structural Engineering. amzn.to/3FpwLyK
    To stay up to date, please like and subscribe to our channel and press the bell button!
    / @structuralengineercalcs
    Should you require expertise in home extensions, loft conversions, comprehensive home renovations, or new construction projects-be it residential or commercial-our team of qualified structural engineers is available to assist you nationwide. This includes major cities such as London, Birmingham, and Greater Manchester. For inquiries or to initiate a consultation, please contact us at +44 7359 267907 or visit our official structuralengi...
    *Disclaimer:*
    None of what we teach in our videos should be taken as 'advice,' and you should always have your designs reviewed by a competent, experienced, registered, or chartered engineer.

Komentáře • 11

  • @emmadavies7434
    @emmadavies7434 Před 2 lety +3

    You don't see many structrual engineers taking time out of there busy life to teach others especially for free! This channel has helped me grow significantly! You’re a constant reminder that people can be good keep it up secalcs! :)

  • @trevluvscarsb6380
    @trevluvscarsb6380 Před 2 lety +1

    Another great video. If only you'd been around when i studied my degree 30 years ago. You explain everything so clearly and its immediately understandable. Excellent. I'm hooked!

  • @TazEditin9
    @TazEditin9 Před 2 lety +1

    It would be great to see some more advanced calculations ; for example an IStructE exam question example and maybe some advise on structure. Appreciate the videos, it’s always helpful to have simple calc tutorials even for more experienced engineers!

  • @ovieagbaga9505
    @ovieagbaga9505 Před 2 lety

    Thank you very much...I can not thank you enough. I still await your pile cap design.

  • @efy5aru
    @efy5aru Před 2 lety

    Yet another great video... Many thanks

  • @milquetoste
    @milquetoste Před rokem

    Hi, thank you so much for your videos. Would you happen to have any references for the 2.5% requirement?

  • @LvPatriot1
    @LvPatriot1 Před 2 lety +4

    Great video, but I have a question. Are those 2.5% mentioned somewhere in the some code, because how should I argument my point of view that it is enough, maybe 3% or 5 % need to be taken?
    You mentioned that steel beems have a tendency, I assume that it is due to the shape which they are produced and placed in the structure. If it would be a solid block but still in steel, then it should not have such problems. Additionally, I assume timber I-joists also can have such problem due to the form, but it can be neglected as they are covered with some sheet and fastened to it which creates quite a rigid system.

    • @StructuralEngineerCalcs
      @StructuralEngineerCalcs  Před 2 lety +9

      According to BS 5950, for one or two restraints, the members must be able to withstand a total force of 2.5 percent of the maximum compressive force in the beam, divided amongst the restraints in proportion to their spacing; for three or more restraints, each restraint should be able to withstand 1% of the maximum compressive force or the 2.5% force distributed in proportion to the restraint spacing. Eurocode 3 (BS EN 1993-1-1), Clause 6.3.2 explains that in order for a steel beam element to be classed as ‘restrained’, its compression flange must have sufficient restraint to prevent lateral torsional buckling. Beams with certain types of cross sections such as closed hollow sections with a height/depth ratio of less than or equal to 2, are not susceptible to lateral torsional buckling.

    • @LvPatriot1
      @LvPatriot1 Před 2 lety

      @@StructuralEngineerCalcs Thanks a lot for such a detailed explanation

  • @newaladyiat5071
    @newaladyiat5071 Před 2 lety

    Very nice video ❤