- 222
- 1 802 601
Electrical and Electronic tech
India
Registrace 4. 03. 2011
To learn about technical of electrical and electronics.
Machines,instruments ECT.
#electricalandelectronictech
Machines,instruments ECT.
#electricalandelectronictech
Siemens relay ct connection
you can easily understand by this video,how to connect ct connection in Siemens relay.
zhlédnutí: 421
Video
How to replace The Transformer LT push.
zhlédnutí 184Před měsícem
you can easily understand by this video , how to replace the transformer LT push.
How to set ct ratio in Siemens 7SR1003 relay
zhlédnutí 184Před měsícem
You can easily understand by this video, how to set ct ratio in Siemens 7SR1003 relay.
CT shorting link
zhlédnutí 2KPřed 3 měsíci
In this video you can easily understand, which shorting link of current transformer are close and open
Micom relay input and output settings
zhlédnutí 402Před 3 měsíci
You can easily understand by this video, how to set input and output of relay.
Breaker class E1M2C2@ElectricalandElectronictech
zhlédnutí 361Před 5 měsíci
Breaker class E1M2C2@ElectricalandElectronictech
Home automation using Bluetooth and Arduino UNO
zhlédnutí 164Před 7 měsíci
You can easily understand by this video,how to do home automation using Bluetooth and Arduino UNO board. I m explaining about wiring,pin details, program upload with step by step. It is 100% working. Link for blutooth app, click below 👇 drive.google.com/file/d/1q1ZJnxYPjkY-MyxqHwGKF81JienzgUsJ/view?usp=drivesdk Link for home automation using Bluetooth Code, click below 👇 drive.google.com/file/d...
Fiber optical cable splicing
zhlédnutí 237Před 7 měsíci
You can easily understand by this video, how to joint fibre optical cable by splicing machine
HT breaker drawing explain
zhlédnutí 732Před 8 měsíci
In this video you can easily understand, how to see and trace the electrical drawing.
CG VFD id run
zhlédnutí 351Před 9 měsíci
You can easily understand by this video, how to do ID run in CG VFD
CRM test (circuit Breaker contact resistance measurement)
zhlédnutí 2,3KPřed rokem
CRM test (circuit Breaker contact resistance measurement)
what is icu ics in mccb acb@electrical and electronic tech
zhlédnutí 2KPřed rokem
what is icu ics in mccb acb@electrical and electronic tech
Circuit Breaker open,close,c-o test and reason for the test
zhlédnutí 2,3KPřed rokem
Circuit Breaker open,close,c-o test and reason for the test
What is ISF and ALF in current transformer
zhlédnutí 8KPřed 2 lety
What is ISF and ALF in current transformer
𝗦𝗜𝗠𝗨𝗟𝗔𝗧𝗘𝗗 𝗦𝗜𝗡𝗘𝗪𝗔𝗩𝗘 𝗔𝗨𝗥 𝗣𝗨𝗥𝗘𝗦𝗜𝗡𝗘𝗪𝗔𝗩𝗘 𝗔𝗨𝗥 𝗠𝗢𝗗𝗜𝗙𝗜𝗘𝗗 𝗦𝗜𝗡𝗘𝗪𝗔𝗩𝗘 𝗜𝗡𝗩𝗘𝗥𝗧𝗘𝗥 𝗔𝗨𝗥 𝗨𝗣𝗦 𝗠𝗘 𝗔𝗡𝗧𝗔𝗥
❤
Very good
We need MICOM E1 Battery Box
Sir please make a video on netural ester oil for transformermers
Great explanation!
Hello sir,can you help me🙏
Very excellent graphics and excellent way to convey the concept. Thank you very much. Wonderful way of communication. Really appreciated.
Çok guzel ama dilinizi anlamiyorum
Well Explained. working in Oil and Gas Design Engineering filed, they should be know.
Can u explain tamil
These are all videos available in my Tamil you tube channel Voltage tech tamil
Gajab
Great Sir😀😀😃😃
Super
Wow! thanks a lot for your information.
Very good
Tik aey💯👌🏻
Very good information thanks a lot sir
Mog per 30 digri kyo likha hota hai sir ji
I can't understand the language. Take your things and go. Come again.
We need patience for this work😊
Nice topic
What happened when voltage in any phase came 10% less
In ka kya matlab hota hai?
Good i under stand
👍👍👍👍
Thank you
You Should more work on the teaching process.
Thanks sir good video i see approx 30 video but nobody explain how capacitor change the phase angle but you explain it
Very nice
Amazing sir
Thank you sir for your information 🙏
Excellent
Amazing explanation sir
Explain in english bro...
Very nice explanation sir
Heatsink parameters no.?
Three phase mein kaise test kare
sir can u explain by video what happen if we use different class for overhead line..substation A using CT class X..but another remote end substation using CT class 5P20..what happen if fault occured..??
Good
Very good
Very good 🙏
City supply on hote hi trip hota hai.. kya kare???
Well sir, simply explained
Plc in put and out put fault finding details video send me
Sir please LAVTSC penal ke bare me ek video banaiye
Please sir 🙏
Very nice...keep continue..try to make video daily...topic wise
What is @6 Ir written in Overload (long time). Can you clarify on this.
Sir Nice Explained and one doubt i have to asked everytime we calculate fault current at secondary side only
Because we have connect load that means equipment, machine,busbar everything in secondary side only.the secondary current flow in this all items.so we must calculate fault current using secondary.
Sir there is one input from WTI CT, and other input is from oil pocket , so the indicator move from both the inputs how it is possible