Team Instrumentation & Controls
Team Instrumentation & Controls
  • 42
  • 643 979
GE Gas turbine protections- Part 3! Protective status trips! L4PSTX2
GE Gas turbine protections- Part 2! Protective status trips! L4PSTX1 czcams.com/video/pPCQXxaxVLQ/video.html
GE Gas turbine protections- Part 1! Pre-Ignition trips czcams.com/video/GjOmNOKItPQ/video.html
zhlédnutí: 2 479

Video

GE Gas turbine protections- Part 2! Protective status trips! L4PSTX1
zhlédnutí 2,3KPřed 2 lety
GE Gas turbine Protections- Part 1:Pre ignition trips! czcams.com/video/GjOmNOKItPQ/video.html
Honeywell DCS System: PID Controller! Programming part 3! PID controller practical explained!
zhlédnutí 14KPřed 2 lety
On thos video,O have explained about the basic functionality of PID controller. hope you like the video, watch it completely & let me know your thoughts
GE Gas turbine protections- Part 1! Pre-Ignition trips
zhlédnutí 8KPřed 3 lety
In this video I have explained various trip conditions related to Pre-Ignition. I will prepare few more videos related to other trip conditions also. protective status trip 1: czcams.com/video/pPCQXxaxVLQ/video.html
Power distribution in Mark VIe cabinet!
zhlédnutí 3,4KPřed 3 lety
In this video, we have explained to he detailed power flow in Mark VIe cabinet
HRSG Control Loops-2: Deaerator pressure control loop! Split range PID control loop
zhlédnutí 2,2KPřed 4 lety
In this video, How Deaerator pressure is maintained is explained from control loop diagram.
HRSG Control Loops-1: Deaerator Level Control
zhlédnutí 4,4KPřed 4 lety
In this video, I have explained about Deaerator level control loop from p&I'd and logic diagram. In upcoming few videos we will cover all the control loops of HRSG for CCPP.
GT Compressor offline water wash
zhlédnutí 8KPřed 5 lety
GT Compressor offline water wash
GE Gas turbine EOP DC logic
zhlédnutí 10KPřed 5 lety
GE Gas turbine EOP DC logic
GT Compressor Online water wash.
zhlédnutí 1,9KPřed 5 lety
GT Compressor Online water wash.
Honeywell DCS: Assignment of new IO modules in existing configuration
zhlédnutí 21KPřed 5 lety
Honeywell DCS: Assignment of new IO modules in existing configuration
Eccentricity in steam turbine!
zhlédnutí 3,5KPřed 5 lety
Eccentricity in steam turbine!
Honeywell DCS annual maintenance- part 1: Therotical overview
zhlédnutí 4,6KPřed 5 lety
In this video, the theoretical explanation is given for understanding the procedure & giving the support to upcoming part 2 video. In next video we will have practical exposure & real time redundancy check of power supply, controller, severs etc.
GE Gas turbine Hazardous Gas detection rack overview & its trip logics!
zhlédnutí 2,3KPřed 5 lety
GE Gas turbine Hazardous Gas detection rack overview & its trip logics!
Calibration of Diaphragm Pressure Transmitter!
zhlédnutí 3,1KPřed 5 lety
Zero trimming & performing the calibration of pressure transmitter.
Calibration of Diaphragm Pressure Switch!
zhlédnutí 4KPřed 5 lety
Calibration of Diaphragm Pressure Switch!
Honeywell DCS server's redundancy checking! "Manual failover & synchronization"!
zhlédnutí 11KPřed 5 lety
Honeywell DCS server's redundancy checking! "Manual failover & synchronization"!
Honeywell DCS programming- Part 2: Data Acquisition block fully explained
zhlédnutí 25KPřed 5 lety
Honeywell DCS programming- Part 2: Data Acquisition block fully explained
Calibration of SMARTPro pH 8966 smart transmitter!
zhlédnutí 16KPřed 5 lety
Calibration of SMARTPro pH 8966 smart transmitter!
Bently Nevada 3500 rack & modules overview!
zhlédnutí 37KPřed 5 lety
Bently Nevada 3500 rack & modules overview!
Honeywell DCS system! SOP for IO channel reconfiguration in Honeywell EPKS!
zhlédnutí 15KPřed 5 lety
Honeywell DCS system! SOP for IO channel reconfiguration in Honeywell EPKS!
Honeywell DCS System - C300 Controllers manual synchronisation!
zhlédnutí 20KPřed 5 lety
Honeywell DCS System - C300 Controllers manual synchronisation!
Important engineering tools in Honeywell Experion PKS DCS!
zhlédnutí 27KPřed 5 lety
Important engineering tools in Honeywell Experion PKS DCS!
GE Gas turbine (6FA machine) AOP logic in Mark VIe system!
zhlédnutí 20KPřed 5 lety
GE Gas turbine (6FA machine) AOP logic in Mark VIe system!
Boiler feed water pump & motor- part 2! DCS supervisory instruments
zhlédnutí 9KPřed 5 lety
Boiler feed water pump & motor- part 2! DCS supervisory instruments
IO module replacement in Honeywell DCS!
zhlédnutí 11KPřed 5 lety
IO module replacement in Honeywell DCS!
How motor start when DCS gives command! Feeder power & control circuit explained
zhlédnutí 48KPřed 5 lety
How motor start when DCS gives command! Feeder power & control circuit explained
Boiler feed water pump & motor- part 1!
zhlédnutí 21KPřed 5 lety
Boiler feed water pump & motor- part 1!
Motor start stop logic in Honeywell DCS! Logic explanation & Practical demonstration
zhlédnutí 38KPřed 5 lety
Motor start stop logic in Honeywell DCS! Logic explanation & Practical demonstration
Honeywell DCS system (EPKS) hardware overview & signal flow in DCS explained!
zhlédnutí 76KPřed 5 lety
Honeywell DCS system (EPKS) hardware overview & signal flow in DCS explained!

Komentáře

  • @faizanmajeedmalik4591

    I need operator display software. With this old software I am facing issue with Gen Protection error. Anyone can help this issue

  • @instrumentationbasicknowle2872

    How can I contact to you sir ???

  • @imti007ful
    @imti007ful Před 20 dny

    Thank u for the explanation...how to get such jobs? Can a computer science BE graduate get this type of jobs? If yes, how?

  • @MahaboobBashaShaik-qh9bs
    @MahaboobBashaShaik-qh9bs Před měsícem

    Next level explation Those r hungry to learn

  • @MariGarcia-mk1nf
    @MariGarcia-mk1nf Před měsícem

    Excelente explicación ❤

  • @akankshasharma9000
    @akankshasharma9000 Před měsícem

    Signal flow loop can you explain from probe to rack ..I am new in instrumentation industry I want to know from basics ..your video is very informative..thanks

  • @raghuraghavendra9456
    @raghuraghavendra9456 Před 2 měsíci

    Hi, I don't have configuration password. Tried 0000. Not working. Can you please help me on this?

  • @rameshwarlalgupta6503
    @rameshwarlalgupta6503 Před 3 měsíci

    Can you share your contact no regarding solution for one problem regarding water wash

  • @rameshwarlalgupta6503
    @rameshwarlalgupta6503 Před 3 měsíci

    Sir very good and informative knowledge share this halp me more thank you

  • @user-sq8jc1ex9l
    @user-sq8jc1ex9l Před 3 měsíci

    Alarm Selection option, change of state, off normal, alarm description mein confusion hai, please guid

  • @aashutoshkashyap3920
    @aashutoshkashyap3920 Před 3 měsíci

    Excellent 👌

  • @Rohit-zc2ew
    @Rohit-zc2ew Před 4 měsíci

    To good for controler understand sir

  • @Rohit-zc2ew
    @Rohit-zc2ew Před 4 měsíci

    Nice sir

  • @nayrbsworld3048
    @nayrbsworld3048 Před 4 měsíci

    thanks for sharing 🙏

  • @nayrbsworld3048
    @nayrbsworld3048 Před 4 měsíci

    nice. please create more

  • @pradipmane027
    @pradipmane027 Před 4 měsíci

    Ur voice is not clear

  • @naidulagudu1761
    @naidulagudu1761 Před 4 měsíci

    Very detailed content thank you🎉

  • @Dinatub470
    @Dinatub470 Před 5 měsíci

    Nice explain

  • @amarnikam3965
    @amarnikam3965 Před 6 měsíci

    Can you explain the Honeywell power tool and upload the video on it plz...

  • @MohammedMohammed-ih7ln
    @MohammedMohammed-ih7ln Před 6 měsíci

    Thanks for sharing and explaining

  • @worldinstrumentationengineer

    Very good ji

  • @Vcstrwqczg21-sw7ru
    @Vcstrwqczg21-sw7ru Před 7 měsíci

    Pls make in hindi

  • @markbizmark4608
    @markbizmark4608 Před 7 měsíci

    Sorry, will the software be available for download? Thank you in advance.

  • @jcl0511
    @jcl0511 Před 7 měsíci

    and there is 'first out' block in epks.

  • @ahmednoura4384
    @ahmednoura4384 Před 7 měsíci

    Hello .i have problem .i need help pleas During the data upload operation from the rack to the PC, we noticed that only the TDI card displays data, while the other locations (slots) remain inexplicably empty. This observation raises concerns about the integrity and recovery of data stored in other rack locations. Attempting to download the program to the rack encountered a major obstacle due to the mismatch between the virtual slots (blue) and physical slots (green) relative to the TDI board. The TDI card is designed to interface with physical rack slots, but due to this incompatibility, the download process remained unsuccessful

  • @ahmednoura4384
    @ahmednoura4384 Před 7 měsíci

    Hello .i have problem i need help pleas During the data upload operation from the rack to the PC, we noticed that only the TDI card displays data, while the other locations (slots) remain inexplicably empty. This observation raises concerns about the integrity and recovery of data stored in other rack locations. Attempting to download the program to the rack encountered a major obstacle due to the mismatch between the virtual slots (blue) and physical slots (green) relative to the TDI board. The TDI card is designed to interface with physical rack slots, but due to this incompatibility, the download process remained unsuccessful

  • @toufikbettahar8041
    @toufikbettahar8041 Před 8 měsíci

    Is TDI a hotswaped module ?

  • @mazharulislam5584
    @mazharulislam5584 Před 8 měsíci

    Hello Sir. I do like to ask if you know why gland steam pressure is kept so low? In our plant It's just 0.07 kgf/cm^2. Though we have to operate around o.45 kgf/cm^2. Thanks.

  • @_your.aditya_
    @_your.aditya_ Před 8 měsíci

    thanks thanks thanks

  • @_your.aditya_
    @_your.aditya_ Před 8 měsíci

    very good video

  • @akshayanath1748
    @akshayanath1748 Před 8 měsíci

    Sir I am fresher in Honeywell dcs so please I want to see clearly.

  • @akshayanath1748
    @akshayanath1748 Před 8 měsíci

    Not clearly showing the system display.

  • @veerkumar3452
    @veerkumar3452 Před 9 měsíci

    Sir Dol starter me use kiye gaye in 5 relays ke kiya kaam hai please explain in full details with help of control circuits diagram

  • @user-xc9td5ie6n
    @user-xc9td5ie6n Před 9 měsíci

    Experian PKS r Plant cruise

  • @veerkumar3452
    @veerkumar3452 Před 9 měsíci

    Sir very very thanks for sharing this informative videos with everyone.sir you are requested to please explain once again in fully details the above video using through control circuit diagram on the paper or with the help of control circuit diagram.and with the help of controlling circuit ferul identify nos physically.Thanks

  • @chitraputhiransarguru1976
    @chitraputhiransarguru1976 Před 9 měsíci

    please update start up and shut down seq

  • @rahulbhandary9393
    @rahulbhandary9393 Před 10 měsíci

    😷

  • @navdakram
    @navdakram Před 10 měsíci

    AOA respected sir I got an error while configuring readial vibration that is "Invalid Direct Value" do you have any idea please help me It is Bentley Nevada 3500 3300xl prob

  • @satish_maru
    @satish_maru Před 10 měsíci

    How to install cross sir

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    Can I get your wattupp line

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    Please I need help

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    I am new in a company which has Allen-Bradley, honeywell, siemens and other plc

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    I want people like you to be my mentor or to learn from

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    I am new in control and instrumentation field

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    Hi my name is Chris from Ghana 🇬🇭

  • @christianamoako9307
    @christianamoako9307 Před 10 měsíci

    Hi

  • @bandutharakhare3774
    @bandutharakhare3774 Před 10 měsíci

    Sir how to assign any Parameters pls explain us