Regal Rexnord
Regal Rexnord
  • 392
  • 1 430 422
Mastering Automation in Modern Warehouses: Expert Insights to Boost Efficiency and Cut Costs
From advancements in artificial intelligence (AI) and robotics to the seamless integration of advanced sortation and warehouse management systems, automation is transforming material handling as we know it. While automated technologies significantly enhance productivity and operational efficiencies in modern warehouses and distribution centers, the pressure to quickly integrate these new technologies can easily become overwhelming. With so many options available, where does one begin?
With over 30 years of experience in the intralogistics and parcel industries, business development expert and Global Strategic Account Manager at Regal Rexnord™ Don Overberg shares his insights on the implementation, benefits, and future of automation technologies. In this webinar with PARCEL magazine, Don shows viewers how to navigate the intricate ecosystem of automated technology and shares real-world tips on how to save thousands in labor costs, streamline efficiency, and increase capacity.
zhlédnutí: 35

Video

COPRA™ EC Plug Fans
zhlédnutí 116Před 14 dny
Meet our Sales & Marketing Director, Tim Thorson, while he takes you through the advanced features and benefits of the Copra Plenum Fan, a powerhouse in HVAC technology. Combining the precision engineering of Regal Rexnord and Nicotra Gebhardt, this fan is equipped with an IE6 motor, offering unmatched efficiency and reliability. Discover why the Copra Plenum Fan is the top choice for demanding...
Motor Minute™ Technical Tip: What is a C-Face Motor?
zhlédnutí 296Před 14 dny
Regal Rexnord™ Motor Minute™ technical tips provide you with information to enhance your motor knowledge. Supplied in a one minute or so video format giving you the ability to learn on the go, on a break, or whenever you have a minute to learn. This month’s tech tip discusses the application and unique mounting design of C-face motors (also referred to as direct coupled) and universal replaceme...
Introducing Genteq® Evergreen® EM Dual Voltage Motors
zhlédnutí 151Před 21 dnem
With 2 motors on the truck, the new Evergreen EM dual voltage motors will likely replace over 90% of OEM constant torque ECM motors. Built with automatic rotation sensing, the same plug connection as the majority of the industry's OEM constant torque motors, and pre-programmed for use right out of the box with no apps or configuration, Evergreen EM motors make ECM easy. It’s now easier than eve...
The New Genteq® Evergreen® OM Motor Makes ECM Easier
zhlédnutí 297Před 21 dnem
The new Evergreen OM motor maximizes versatility and simplicity to provide a single motor with the ability to replace 24 PSC outdoor condensing fan motor ratings. Built with a reduced end shield to end shield length to fit more PSC applications, the new Evergreen OM Stock #6303S makes it easy to reduce inventory on the truck, increase first call completions and replace millions of PSC outdoor c...
Introducing the New Genteq® Evergreen® OM Motor
zhlédnutí 143Před 21 dnem
Balancing versatility and simplicity, the new Evergreen OM motor replaces millions of PSC outdoor condensing fan motor ratings. This motor also installs and connects just like a PSC motor. Built with a reduced end shield to end shield length, multiple mounting options, no programming and no complex wiring, the new Evergreen OM Stock #6303S defines ECM Made Easy™. MCV24028E
Evergreen OM Motor #6303S Applications
zhlédnutí 220Před 21 dnem
This video is a condensed version of the new Evergreen OM motor #6303S installation video (MCV24030E) directly focusing on the applications this motor is used in. This new Evergreen OM motor is designed to replace PSC outdoor condenser fan motors and is capable of replacing 28 PSC motor ratings with 1 motor. MCV24031E
Evergreen OM Motor #6303S Mechanical Installation
zhlédnutí 123Před 21 dnem
This video is a condensed version of the new Evergreen OM motor #6303S installation video (MCV24030E) directly focusing on the mechanical installation of this motor. This new Evergreen OM motor is designed to replace PSC outdoor condenser fan motors and is capable of replacing 28 PSC motor ratings with 1 motor. MCV24032E
Evergreen OM Motor #6303S Electrical Connections & Operation
zhlédnutí 222Před 21 dnem
This video is a condensed version of the new Evergreen OM motor #6303S installation video (MCV24030E) directly focusing on the electrical connections. This new Evergreen OM motor is designed to replace PSC outdoor condenser fan motors and is capable of replacing 28 PSC motor ratings with 1 motor. MCV24033E
Evergreen OM Motor #6303S Complete Installation
zhlédnutí 334Před 21 dnem
This video covers the complete installation of new Evergreen OM motor #6303S including applications, mechanical installation, electrical connections and operation. The new Evergreen motor is designed to replace PSC outdoor condenser fan motors and is capable of replacing 28 PSC motor ratings with 1 motor. MCV24030E
Genteq® Evergreen® EM Dual Voltage Motors Make ECM Easy
zhlédnutí 225Před 21 dnem
Introducing the next generation Evergreen EM motors with dual voltage 115 and 208-230 VAC capability. Built with automatic rotation sensing, the same plug connection as the majority of the industry's OEM constant torque motors, and pre-programmed for use right out of the box with no apps or configuration, Evergreen EM motors make ECM easy. MCV24027E
Get Smart, Efficient, and Connected with the SyMAX-SRt Motor
zhlédnutí 12Před 21 dnem
MCV23096E SB0397
Experience Precise Airflow and SKU Reduction with the SYMAX-SRi Motor
zhlédnutí 21Před 21 dnem
MCV23064E Experience Precise Airflow and SKU Reduction with the SYMAX-SRi Motor
Cut Costs, Boost Efficiency, and Minimize Maintenance with the SyMAX-SRi Motor.
zhlédnutí 108Před 21 dnem
Cut costs, boost efficiency, and minimize maintenance with the SyMAX-SRi motor.
How Conveyor Technologies are Adapting to Evolving Market Trends
zhlédnutí 50Před 28 dny
Is your business facing production challenges like keeping up with speed demands, but finding that newer packaging containers are more easily damaged increasing product and packaging waste? Regal Rexnord is an expert in conveyance systems and are here to guide you through the tailored solutions available to meet your business goals and mitigate these challenges. From integrating new technologie...
Genteq® Motors HILO Fan with Backwards Compatibility
zhlédnutí 42Před měsícem
Genteq® Motors HILO Fan with Backwards Compatibility
Genteq® Motors HILO Fan with Near Field Communications
zhlédnutí 35Před měsícem
Genteq® Motors HILO Fan with Near Field Communications
Next Generation Solutions for Condition Monitoring & Predictive Maintenance
zhlédnutí 191Před měsícem
Next Generation Solutions for Condition Monitoring & Predictive Maintenance
Robotic Conveyor Systems to Maximize Throughput
zhlédnutí 48Před měsícem
Robotic Conveyor Systems to Maximize Throughput
Motor Minute™ Technical Tip: What Does the NEMA Frame Size Tell You About Rigid Base Motors?
zhlédnutí 256Před měsícem
Motor Minute™ Technical Tip: What Does the NEMA Frame Size Tell You About Rigid Base Motors?
Rexnord® 6400 Series KleanTop® Plastic Spiral Cage Belt Video Overview
zhlédnutí 57Před měsícem
Rexnord® 6400 Series KleanTop® Plastic Spiral Cage Belt Video Overview
Intelligent Solutions for Cooling Tower Basin Pump Area
zhlédnutí 128Před měsícem
Intelligent Solutions for Cooling Tower Basin Pump Area
Boston Gear Gen2 SS700 Series | Keyless Tapered Bushing Install, Shaft Mounting, and Gearbox Removal
zhlédnutí 143Před měsícem
Boston Gear Gen2 SS700 Series | Keyless Tapered Bushing Install, Shaft Mounting, and Gearbox Removal
Boston Gear Gen2 SS700 Series | Demonstration of Field Installation and Removal of Shaft Cover
zhlédnutí 69Před měsícem
Boston Gear Gen2 SS700 Series | Demonstration of Field Installation and Removal of Shaft Cover
Flex-in-1® General Purpose Motors | LEESON® Motors
zhlédnutí 149Před 2 měsíci
Flex-in-1® General Purpose Motors | LEESON® Motors
Motor Minute™ Technical Tip: What's the Difference Between a 42 and 48 Frame Direct Drive FHP Motor?
zhlédnutí 457Před 2 měsíci
Motor Minute™ Technical Tip: What's the Difference Between a 42 and 48 Frame Direct Drive FHP Motor?
48 Frame Motor Presentation at AHR 2024
zhlédnutí 80Před 3 měsíci
48 Frame Motor Presentation at AHR 2024
Flex-in-1® Motor Configuration at AHR 2024
zhlédnutí 65Před 3 měsíci
Flex-in-1® Motor Configuration at AHR 2024
SyMAX®-SRi Motor Presentation at AHR 2024
zhlédnutí 69Před 3 měsíci
SyMAX®-SRi Motor Presentation at AHR 2024
SR Motor Line Presentation at AHR 2024
zhlédnutí 43Před 3 měsíci
SR Motor Line Presentation at AHR 2024

Komentáře

  • @petecolborn4289
    @petecolborn4289 Před 12 dny

    I have a pentair WF-4. Will this motor work? What other parts will I need to retrofit to it?

  • @mtbbiker6401
    @mtbbiker6401 Před 18 dny

    I've done some diagnostic testing using jumpers. My ECM2.3 just sort of rumbles and tries to spin but doesn't. I'm assuming it's getting power. Any idea if it's the control unit or actual motor that might be bad?

  • @jhowardmarkleyjr3335
    @jhowardmarkleyjr3335 Před 19 dny

    So which of the pins need power to test the motor without having to buy another product from you?

  • @blewis7359
    @blewis7359 Před 25 dny

    The selling point would have been to measure the wattage draw of the original system then show the draw of you replacement system. My blower motor draws about 650 watts at 110 VAC.

  • @LuisDeAraujo-sr3pf
    @LuisDeAraujo-sr3pf Před 28 dny

    Sir i cannot even begin to explain how long it took to find this vidoe but... I love you.

  • @cstephenmurray
    @cstephenmurray Před 29 dny

    (Repeat from other video. I want them to see this.) Homeowner review of product: I just replaced my motor with one of these. It's working fine. Now the suggestions: 1) There were no instructions for anything other than basic wiring either in the box or easy to find on their website. 2) The wires are WAY TOO SHORT! I had to cut off the wires from my old unit and splice them in. That makes no sense. If other manufacturers can put on longer wires, so can Century. 3) As a color deficient person I often have to have my wife help identify the colors. On the old unit the brown and black were very different. Once identified, I could easily tell them apart. My wife had to look closely to tell the brown and black apart on the Century. Not good! Fix these things and I would be happy.

  • @cstephenmurray
    @cstephenmurray Před 29 dny

    Homeowner review of product: I just replaced my motor with one of these. It's working fine. Now the suggestions: 1) There were no instructions for anything other than basic wiring either in the box or easy to find on their website. 2) The wires are WAY TOO SHORT! I had to cut off the wires from my old unit and splice them in. That makes no sense. If other manufacturers can put on longer wires, so can Century. 3) As a color deficient person I often have to have my wife help identify the colors. On the old unit the brown and black were very different. Once identified, I could easily tell them apart. My wife had to look closely to tell the brown and black apart on the Century. Not good! Fix these things and I would be happy.

    • @pcntrader
      @pcntrader Před 8 dny

      You are not a certified technician. This is not made for homeowner DIY. A certified technician can easily identify the wiring and installations. Long or short wires has never matter for a certified technician

  • @Peterruscito
    @Peterruscito Před měsícem

    That was not helpful. Need to know how to wire a variable speed motor into a single speed system.

  • @igrifaldo82
    @igrifaldo82 Před měsícem

    I’m only here to say for ECM motor on my three year old outside hvac compressor stopped working.

  • @microflowmeter
    @microflowmeter Před měsícem

    👍

  • @jamesswitalski9168
    @jamesswitalski9168 Před 2 měsíci

    Do we not know the cfm? Do we just look for .5 or lower with good delta T, SC, SH?

  • @Cedartreetechnologies
    @Cedartreetechnologies Před 2 měsíci

    Great tutorial on clever tech. I just had my 10 yr old ecm furnace blower motor replaced for the low, low price of $700. When I asked the service tech WtF, he said "ecm motor". So here I am. Sure, it's more efficient during its brief lifetime. But instead of being a cheap lifetime purchase, it cost me $70/yr for replacement cost. The probability that it saves $70/yr in electricity, seems quite low.

  • @avguytx4361
    @avguytx4361 Před 2 měsíci

    Piece. Of. Crap. Our Rheem motor made it 5 years exactly and now it powers on by itself, might shut off in a short time, might not, or might turn off when it's done calling for AC, or it might try to run for another hour or more and raise humidity. This even with the thermostat wires disconnected.

  • @user-ty2uz4gb7v
    @user-ty2uz4gb7v Před 3 měsíci

    My genteq x13 died after 8 years

  • @zapsurf1343
    @zapsurf1343 Před 3 měsíci

    3 year old Rheem unit fan motor died. Complete garbage.

  • @Darkblend
    @Darkblend Před 3 měsíci

    These will need replaced every 18 to 24 months. I'm on my 3rd. Male sure you install a high pressure switch.

  • @Americaiswithisrael9794
    @Americaiswithisrael9794 Před 5 měsíci

    Ecm motors are just a way to ensure motors go out more often

  • @shivomkuswaha3239
    @shivomkuswaha3239 Před 5 měsíci

    Mairathan company ki motor ka koi jawab nahin bahut hi ek number ki motor hoti hai

  • @del1rn
    @del1rn Před 5 měsíci

    ok, where do I get the service Manual ?

  • @cmatt1982
    @cmatt1982 Před 5 měsíci

    It should stand for Extremely Crappy Motor. These things are a money grab and a joke. Whoever developed this technology need to be brought out behind the wood shed.

  • @jonnymakers9560
    @jonnymakers9560 Před 6 měsíci

    The only thing that is constant in my $8K brand new furnace is a motor whine noise...I hate it. We are in talks with the tech....

  • @24rxman
    @24rxman Před 6 měsíci

    Is techinspect from supplyhouse the same tool as tech mate pro?

  • @agustinguzman6375
    @agustinguzman6375 Před 7 měsíci

    "infinity"... "infinity"??? you have a meter that measures "infinity"??...

  • @jonminnella4157
    @jonminnella4157 Před 7 měsíci

    Great technology however the price of the motor is a big problem

  • @dwayneflint8332
    @dwayneflint8332 Před 7 měsíci

    Why don't you update this vid.. can't buy shit for this steaming pile of engineering crap.. It'd be nice if you did a diagnostic on the ECM portion, maybe how to program this steaming pile of engineering failure. Just disgusted at your folks lack of support and parts and the monopolistic planned obsolesence of this POS. You point fingers at Nordyne, yet you manufactured this steaming pile and provide NO PARTS and Nordyne the steaming pile they are says this POS is a defunct and no longer supported PN. How MF convenient. THIS IS TOTAL BS. Support the POS engineered GE steaming pile with parts for the 100's of thousands of homeowners that this POS is in.

  • @davem3789
    @davem3789 Před 8 měsíci

    Can the TCB wear indicator be used on a melt shop crane? Temp ~ 135F

  • @GotchaplumberGotchahvac
    @GotchaplumberGotchahvac Před 9 měsíci

    Do u have any other wiring sources for ECM motors? Thank u.

  • @heethen112
    @heethen112 Před 9 měsíci

    I’m old so you saying this is easier doesn’t work for me. I prefer to know exactly where when why how the problem is. Not offering a Corel module is dumb too. Now we have the even stupidest technology with Bluetooth will present many new problems.. too many to cover, but one I will say is, now people that shouldn’t be trying to fix things they don’t comprehend!! On top of it will take away from many aspects of technicians..??

  • @Reisskraft
    @Reisskraft Před 9 měsíci

    What if the motor runs without 24 volt input?

    • @avguytx4361
      @avguytx4361 Před 3 měsíci

      That's what mine is currently doing. Sometimes keeps running after the call for AC is done and outside condenser is off, sometimes it works right and shuts off after 45 seconds, sometimes it comes right back on and runs for any weird amount of time, and sometimes I finally have to turn the breaker off. At least now there are alternatives to replacing this whole overpriced motor. You can do just an ECM or buy a Mars or Evergreen complete motor and it learn. Crazy.

  • @716ra
    @716ra Před 9 měsíci

    PROBSTROKER

  • @KL4life
    @KL4life Před 9 měsíci

    You mean "3 and 4" taps not " 2 and 3" is this guy even paying attn??

  • @shifter8207
    @shifter8207 Před 10 měsíci

    I had a similar problem with a 2.3 and the Supco tradefox tester and the motor ran but not with harness. Not sure if some testers have different ways of testing the motor

  • @luismiguel4156
    @luismiguel4156 Před 10 měsíci

    Can I lower the speed of this motor?

  • @hectorlongoria9625
    @hectorlongoria9625 Před 10 měsíci

    I have an issues with x13 it does its cycle but repeatedly turns on for 1,to 2seconds the off multiply times any info icm and motor have been replaced still same issues

  • @mercedessalazar8769
    @mercedessalazar8769 Před 11 měsíci

    Hi, When you connect the TechMate Pro does the motor run in full speed?

  • @gtnaidu5449
    @gtnaidu5449 Před 11 měsíci

    It's a wonderful technology

  • @JuanSolano-zd3ky
    @JuanSolano-zd3ky Před 11 měsíci

    Favor de traducirlo al español... saludos cordiales desde ESCOBEDO N.L. México septiembre 5 2023

  • @tommytran2975
    @tommytran2975 Před rokem

    these are junk!!! i bought a brand new rheem unit.. replaced it 2.5 years ago and 2.5 years later today i just literally had to replace it again!

    • @jameschen1913
      @jameschen1913 Před 4 měsíci

      Mine same, this shitting quality shouldn’t be in the market, is there somewhere for consumers to get reimbursed by the manufacturer? We should file lawsuits against them

    • @PumpkinKingXXIII
      @PumpkinKingXXIII Před 21 dnem

      Same, Rheem 142r 1/3 hp, mine always sounded wrong to me when it started. The installer said that was normal, 2 years latter and it failed, they replaced it, made the same screeching noise on startup and about 2 years again it failed again, I had to buy a used unit because I couldn’t find a new one anywhere, last weekend the used one died and big surprise is its backordered everywhere. Motors are fine but controllers seem to fail but they don’t sell controllers separately. It’s almost like they know it’s a weak point

    • @tommytran2975
      @tommytran2975 Před 21 dnem

      @@PumpkinKingXXIIIdesigned to fail is my thought. Junk junk junk.

  • @kenthomas4668
    @kenthomas4668 Před rokem

    Want to try something really cool if the motor ohms out bad? Look in there and find where the winding wires are wrapped around each other. Un wind them and if the motor was testing bad it isn't any more. Bad design!

  • @CarolHenderson-xz2iw

    Two of these have died in my Rheem A/C over the past 6 years. He mentions surge protection, but as an electrical engineer I have studied the circuit diagram, there is a thermistor, for inrush current control, but NO surge protection.

    • @jameschen1913
      @jameschen1913 Před 4 měsíci

      Mine same, 4.5 years two of them died, this is piece of junk motor

  • @jasonr6957
    @jasonr6957 Před rokem

    Buyer beware, I'm on my third ECM in 15 years. A better video to watch is how to convert to ECM to PSC motor for a small fraction of the cost.

  • @jarulegotoschool
    @jarulegotoschool Před rokem

    Go Pat! Awesome technology.

  • @Jason-wc3fh
    @Jason-wc3fh Před rokem

    In terms of overall comfort and nice slow start/stopping it's a nice design for homeowners that don't care to listen to the sound of the furnace while also saving a couple dollars in hydro consumption. They can drop to ridiculously low rpms for continuous fan operation that a psc cannot do. However, once that module fails and needs replacing, the manufacturer is laughing their way to the bank with the cost of the replacement that consists of about $50 or less in electronic parts is somewhere between $600 to over $1000 just for the module, not even including a motor!

  • @dyorneyman341
    @dyorneyman341 Před rokem

    Im waiting gor you to say the voltage ouput in the communication cable...

  • @Garth2011
    @Garth2011 Před rokem

    Sadly, Genteq X13 has a bad reputation for overpriced ECM motors/modules and total unreliable which carries high maintenance costs. Every HVAC tech says so. Maybe find electronic parts that will not fail in 15 years of use ! Cheap inferior components is plain dumb.

  • @Garth2011
    @Garth2011 Před rokem

    Are the modules still failing way too early such as the power in rush component? Seems that those ECM's are well over priced for the benefits they give as just one service call eliminates any savings on power for life.

  • @Garth2011
    @Garth2011 Před rokem

    Question is what are the savings/benefits over a $180 PSC replacement?

  • @victorpeguero5506
    @victorpeguero5506 Před rokem

    Oh I forgot ther are expensive too some costs between $800 to $1500 these pieces of crap

  • @victorpeguero5506
    @victorpeguero5506 Před rokem

    These motor are junk you can't even repair it they make full of cilicone so you can't change a simple capacitor or anything in the module junk junk don't last I had replace twice within a year wherever I go I have to swap it with the psc better