MindaugasV85
MindaugasV85
  • 25
  • 39 922
PLC programming lesson: process subroutine
PLC programming lesson: process subroutine
zhlédnutí: 32

Video

PLC programming lesson: output subroutine
zhlédnutí 161Před měsícem
PLC programming lesson: output subroutine
PLC programming lesson: INPUT subroutine
zhlédnutí 144Před měsícem
PLC programming lesson: INPUT subroutine
Control Box Assembly #12
zhlédnutí 1,4KPřed 2 měsíci
Bliss by Luke Bergs | soundcloud.com/bergscloud/ Creative Commons - Attribution-ShareAlike 3.0 Unported creativecommons.org/licenses/by-sa/3.0/ Music promoted by www.chosic.com/free-music/all/
Balttechnika 2024
zhlédnutí 212Před 2 měsíci
Balttechnika 2024
Control Box Assembly #11
zhlédnutí 958Před 3 měsíci
Luke Bergs & AgusAlvarez - Sunny | soundcloud.com/bergscloud/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY-SA 3.0 creativecommons.org/licenses/by-sa/3.0/ Happy by Luke Bergs | soundcloud.com/bergscloud/ Creative Commons - Attribution-ShareAlike 3.0 Unported creativecommons.org/licenses/by-sa/3.0/ Music promoted by www.chosic.com/free-music/all/
Industrial machines #3
zhlédnutí 316Před 3 měsíci
Conveyors and carriages
Industrial machines #2
zhlédnutí 660Před 6 měsíci
2 axis manipulator
Control Box Assembly #10
zhlédnutí 3,7KPřed 7 měsíci
Copyright: Castle In The Sky - Instrumental by Luke Bergs | soundcloud.com/bergscloud/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY-SA 3.0 creativecommons.org/licenses/by-sa/3.0/ Luke Bergs & AgusAlvarez - Take It Slow | soundcloud.com/bergscloud/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY-SA 3.0 creativecommons.org/licenses/by-sa/3.0/
Control Box Assembly #9
zhlédnutí 1,8KPřed 8 měsíci
Song: Janji - Heroes Tonight (feat. Johnning) [NCS Release] Music provided by NoCopyrightSounds Free Download/Stream: ncs.io/htWatch: czcams.com/video/3nQNiWdeH2Q/video.html
Control Box Assembly #8
zhlédnutí 6KPřed 9 měsíci
Dance by Luke Bergs | soundcloud.com/bergscloud/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY-SA 3.0 creativecommons.org/licenses/by-sa/3.0/ Hangin’ On Palm Trees by Luke Bergs | soundcloud.com/bergscloud/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY-SA 3.0 creativecommons.org/licenses/by-sa/3.0/ Good Vibes by Luke Bergs & LiQWYD | soundclou...
PLC programming lesson #2: moto hour meter
zhlédnutí 208Před 9 měsíci
00:00 creating "moto hour meter" subroutine 19:32 bug??? must be tested! 21:23 let's add days 26:34 let's make Function Block for DVP series PLC 38:00 testing FB 41:24 developing FB 52:55 final FB test 54:45 exporting FB 55:44 FB advantages 61:02 let's make Function Block for AS series PLC 72:28 testing FB 76:00 exporting FB 77:43 importing FB 80:00 final word
PLC programming lesson #1: start/stop technology
zhlédnutí 269Před 9 měsíci
In this lesson I am going to explain you how to use SET, RESET relays. 00:00 creating a project 06:45 start/stop test 10:43 many start/stop buttons 26:13 two hands start buttons 37:24 the end
Industrial machines #1
zhlédnutí 248Před 9 měsíci
Battery powered carriage, max load 12t.
Control Box Assembly #7
zhlédnutí 2,5KPřed 10 měsíci
Control Box Assembly #7
ISPSoft: PLC link (ASCII vs RTU)
zhlédnutí 366Před 10 měsíci
ISPSoft: PLC link (ASCII vs RTU)
Control Box Assembly #6
zhlédnutí 7KPřed 10 měsíci
Control Box Assembly #6
Control Box Assembly #5
zhlédnutí 6KPřed 10 měsíci
Control Box Assembly #5
Duelco safety PLC (DSC-M1): failures simulation
zhlédnutí 467Před 10 měsíci
Duelco safety PLC (DSC-M1): failures simulation
Control Box Assembly #4 (LT language) (pasterizatoriaus skydo surinkimas, programavimas)
zhlédnutí 1,4KPřed 11 měsíci
Control Box Assembly #4 (LT language) (pasterizatoriaus skydo surinkimas, programavimas)
Control Box Assembly #3
zhlédnutí 1,5KPřed 11 měsíci
Control Box Assembly #3
Control Box Assembly #2
zhlédnutí 1,8KPřed 11 měsíci
Control Box Assembly #2
Control Box Assembly #1
zhlédnutí 2,3KPřed rokem
Control Box Assembly #1

Komentáře

  • @alvarodiaz945
    @alvarodiaz945 Před 20 dny

    Saludos, creo a mi experiencia armando tableros de control, que debiste usar un gabinete mas grande, no hay mucho espacio entre los dispositivos de fuerza, y el variador de frecuencia Delta no dejaste el espacio para su enfriamiento a como lo específica el manual de instalación, los cables no están marcados 😢y así varias observaciones 😮...

    • @mindaugasv85
      @mindaugasv85 Před 13 dny

      It's ok with cooling for our climate zone - no issues. The requirements are calculated for max enviroment temperature, for fully load VFD (max currennt), for long continuos running. For really I never had VFD overheating alarm in any project 😉 I add labels just on those wires where it's complicated to replace bad component without wire labels (f.e. vfd control signals). All others are just wasting of resources. Stop playing this "mouse games" when trying to find the issues. If you will pay attention to components labels, you will find components are in groups, f.e. power line 1F1-1DK1-1X1. Control switch 1Sa1.

  • @kieranjones4963
    @kieranjones4963 Před 22 dny

    Great to see you back on CZcams! Was gutted when your videos disappeared!

  • @flinton03
    @flinton03 Před měsícem

    Very clean and professional work.Bravo

  • @flinton03
    @flinton03 Před měsícem

    Nicer , in which country this factory located ?

    • @mindaugasv85
      @mindaugasv85 Před 28 dny

      Lithuania (EU), Earth, Solar system, Milky way galaxy, Universe (no name) 😉😂

  • @NorbaHouse
    @NorbaHouse Před měsícem

    congratulations! As always, good explanation with great examples. I don't want to be boring, but if you have an example of a temperature PID with a recipe, I would really appreciate it. I intend to automate a laminated glass oven. Thanks!! forgive the English, I'm Brazilian and I'm using a translator.

    • @mindaugasv85
      @mindaugasv85 Před měsícem

      I have never did PID with Delta PLC, only with Siemens. But if you have an option to select, use AS series PLC, not DVP - I have heard DVP series PLC has some bugs on some PID types (this information also is old, so maybe bugs have been fixed). P.S. you can write in any language - there's a translate button so I will understand 😉

  • @eugeneberdnik6295
    @eugeneberdnik6295 Před měsícem

    More!Sir, more videos about PLC programming:)

  • @NorbaHouse
    @NorbaHouse Před měsícem

    Feliz que voltou com o canal. Suas explicações e exemplo de montagem de caixas são excelentes. Parabéns pelo bom trabalho.

  • @martnreda8549
    @martnreda8549 Před 2 měsíci

    I was searching a lot for your old channel I was enjoying your old videos❤

  • @manolete19
    @manolete19 Před 2 měsíci

    What software do you use for designing? Could you share the design process?

  • @frm6018
    @frm6018 Před 2 měsíci

    does delta have modifications with the ability to program on structured text?

    • @mindaugasv85
      @mindaugasv85 Před měsícem

      Depends on PLC (some of them has) and software. You can test - software is free. WPLsoft (don't recommen to use this...), ISPsoft (for PLC) or DIAstudio (all in one, like TIA portal). For DIA studio you need to register but it is still free.

  • @alobalo3796
    @alobalo3796 Před 2 měsíci

    I hope if you can explain wiring

  • @pawegorzan5048
    @pawegorzan5048 Před 2 měsíci

    Nice movie, as always😃👍

  • @bennaidjatarek563
    @bennaidjatarek563 Před 2 měsíci

    Nice work 😊

  • @alexsikorskyzero
    @alexsikorskyzero Před 3 měsíci

    😍👍

  • @mahercontrol5696
    @mahercontrol5696 Před 3 měsíci

    good nice ❤

  • @josvandiepen3425
    @josvandiepen3425 Před 3 měsíci

    Green and Yellow colors are not allowed for wiring inside cabinets. Geen/Yellow is for PE/EARTH wire in Europe.

    • @mindaugasv85
      @mindaugasv85 Před 3 měsíci

      Don't panic - it's GROUNDED 0VDC 5:24

  • @josvandiepen3425
    @josvandiepen3425 Před 3 měsíci

    It's not allowed to use metal screws inside the cable conducts. You must use plastic or nylon. NORM EN60204.

    • @mindaugasv85
      @mindaugasv85 Před 3 měsíci

      Can you please show me where in internatiol standard they are writing about this? I doubt very much that this was discussed in this standard. Another thing, the standard is constantly being updated, sometimes there are stupid requirements in it, which are then withdrawn or rephrased. While talking about wire colors, the standard is very old and dumb: they just separated high voltage (black) from safe voltage (blue) and possible voltage when machine is powered off (orange). Also ground (G+Y). But these color standard is very old and in many situations are not helpful. Many companies produce control panels by their own wire color standards (I periodically check this while I see new machines in the factories). I have my own standard too, which is very helpful for debuging or expanding the system: L - black, N - blue, PE - gy. 24VDC - red, 0VDC - green. 24VDC from safety device (relay or contactor) - purple. 24V signala: pnp type - white, npn type - grey. Dry contacts (interlock) - orange. Other control voltage levels - brown, f.e. in 5VDC system, analog voltage signal and so on... So technically I am close to IEC standard. The different is in control (safe!) voltage part. And I am adding labels inside the control panel about the wires colors.

  • @stk5452
    @stk5452 Před 3 měsíci

    Не могли бы вы предоставить схему блока управления?

    • @mindaugasv85
      @mindaugasv85 Před 3 měsíci

      Hello, the drawings are useless for you - it's non standard machine + production line. There's no reason to share it 😉

    • @stk5452
      @stk5452 Před 3 měsíci

      @@mindaugasv85 I would just like to study it, I'm a beginner.

    • @tamaspekar2999
      @tamaspekar2999 Před 2 měsíci

      ​@@mindaugasv85Even if it's not standard, I could also appriciate if you upload them. As a begginer it's good to see useful techniques 😉

  • @FedeTimpano
    @FedeTimpano Před 3 měsíci

    Nice job dude, please keep it up

  • @TS-rs8mx
    @TS-rs8mx Před 3 měsíci

    Відразу видно, що людина любить свою роботу і отримує від неї задоволення.

  • @pawegorzan5048
    @pawegorzan5048 Před 3 měsíci

    I love your movies😍

  • @davesteer1228
    @davesteer1228 Před 4 měsíci

    I have been designing, wiring and writing software for control panels for 30+ years. Self tapping screws - fast, easy, cheap but not professional. Drill tap always the best route. No wire ID. Good luck fault finding this one. Component ID on device. What if device is changed? Low voltage directive states component IDs not on device or on trunking lid. Not sure if Wago terminals, looks like a cheap alternative. No attempt at segregation between ELV and mains voltage. Where was the electrical safety test? Looks like it was just turned on and hope it doesn't catch fire.

    • @mindaugasv85
      @mindaugasv85 Před 4 měsíci

      Thank you for your profesional opinion! It looks like you stuck in 90s with your standards 😁

  • @franciscovillamea644
    @franciscovillamea644 Před 4 měsíci

    Hello, what happened with your previous videos? I have been watching your channel for a long time and I remember other videos you had that were very good

    • @mindaugasv85
      @mindaugasv85 Před 4 měsíci

      Old channel has been deleted. I have uploaded only few old videos - I don't have more ☹️ Also for some "political" reasons I can't upload everything.... Even now I have many video data but just can't share in public 😬

  • @1966sanya
    @1966sanya Před 5 měsíci

    Sveiki. Ar tik surinkinėjate ar ir projektuojate?

    • @mindaugasv85
      @mindaugasv85 Před 4 měsíci

      Labas. Dirbu vienas. Pilnai visa automatika: projektavimas, surinkimas, instaliavimas, programavimas

  • @ArtcomeCi
    @ArtcomeCi Před 5 měsíci

    Ačiū uz video . Kokius mokslus esat baiges ? ka teko studijuoti ? kur papildomai mokindavotes ? CZcams ? Knygos ?

    • @mindaugasv85
      @mindaugasv85 Před 4 měsíci

      Kauno kolegija. Knygos tai saviugdos, nieko apie technika 😁 Keiciu darbovietes kas ~3 metus - geras budas igaut praktikos is skirtingu saltiniu 😂

    • @ArtcomeCi
      @ArtcomeCi Před 4 měsíci

      @@mindaugasv85 Super . Ačiū .

  • @yevheniiyevhenii5396
    @yevheniiyevhenii5396 Před 5 měsíci

    nice job

  • @ArtcomeCi
    @ArtcomeCi Před 5 měsíci

    Ačiū už video . 👊 Gal pasidalintum kur rasti medžiagos kur būtu aprašyta kaip tarpusavyje jungiasi visi skydelyje esantys komponentai ? Mokinuosi elektrika ir labai daug kur paviršutiniškai viskas dėstoma ir trūksta informacijos prie skydelių surinkimo technologijos .

    • @mindaugasv85
      @mindaugasv85 Před 5 měsíci

      Tai renki pagal projektą :) O projektuot išmoksi jau su laiku. Bet vardan smalsumo, tai sakyčiau pasiimk kokio dažnio keitiklio (VFD) aprašymą ir pasianalizuok niuansus, "wirind diagram", parametrizavimą... Aš kai pradėjau dirbt, tai labai daug tų manual'ų perskaitęs, dalį jų taip gana nuoširdžiai. Nesvarbu, kad su laiku pamiršti, bet bent jau galvoj išlieka, kad galima ir "taip anaip" padaryt, o kai bus poreikis kaip tiksliai daryt jau rasi aprašyme.

    • @mindaugasv85
      @mindaugasv85 Před 5 měsíci

      Jei kalbant apie patį projektavimo principą, tai sakyčiau pagrindiniai 3 punktai: Jėgos grandinė; Saugos grandinė (safety); Valdymo grandinė.

    • @ArtcomeCi
      @ArtcomeCi Před 5 měsíci

      @@mindaugasv85 Super . Ačiū už info 👊

  • @ArtcomeCi
    @ArtcomeCi Před 5 měsíci

    Ačiū už idomu video 👊

  • @FedeTimpano
    @FedeTimpano Před 5 měsíci

    After a long time I found your channel again!! Greetings from Argentina

  • @makovled
    @makovled Před 6 měsíci

    Sveiki! Jeskau darbo automatikos skydu surinkimo sferoj . Gal jums reikia pagalbos?

    • @mindaugasv85
      @mindaugasv85 Před 6 měsíci

      Labas. Kad aš vienas dirbu, o skydų surinkimas yra gana maža viso ko dalis 🙂 Tai kol kas išsiverčiu vienas

  • @bennaidjatarek563
    @bennaidjatarek563 Před 6 měsíci

    NICE WORK

  • @pawegorzan5048
    @pawegorzan5048 Před 6 měsíci

    Nice machine. Did you solve the issue with the horizontal motor and brake resistor overheating?

    • @mindaugasv85
      @mindaugasv85 Před 6 měsíci

      It is not overheating - it's just hot 🙂 But the customer is going to replace the motor+drive, I think it will be 1kW.

  • @pawegorzan5048
    @pawegorzan5048 Před 7 měsíci

    Another nice video. Are the servos canopen controlled? I have noticed kinco hmi, which you assembled in few control boxes. What do you think about them? Could you compare them to Delta or Weintek?

    • @mindaugasv85
      @mindaugasv85 Před 7 měsíci

      Yes, servo on canopen. These Kinco HMIs are from old control panels, they are about 10 years old. So I am using old Kinco HMIware soft. I think Kinco HMIs are high quality, never had them failed. I have used maybe about 40-50 these HMI. Only 2 were mechanically broken. If I would compare Delta DOP100 series, the soft of Delta is more user friendly. But Kinco is cheaper 😉

  • @pawegorzan5048
    @pawegorzan5048 Před 7 měsíci

    Welcome back Midaugas, I have been lookig for your movies😄

  • @mahercontrol5696
    @mahercontrol5696 Před 7 měsíci

    ❤❤❤❤ nice

  • @Ahmed-sv1zr
    @Ahmed-sv1zr Před 7 měsíci

    Nice

  • @boolve
    @boolve Před 7 měsíci

    Didžiulė karvė.

  • @rabahbelmiloud4194
    @rabahbelmiloud4194 Před 7 měsíci

    good work bro

  • @rabahbelmiloud4194
    @rabahbelmiloud4194 Před 7 měsíci

    happy that you are back, welcome back bro, keep up

  • @rabahbelmiloud4194
    @rabahbelmiloud4194 Před 7 měsíci

    please would you repost the old videos , i learned a lot from you, by the way i dont use delta devices instead i use siemens

    • @mindaugasv85
      @mindaugasv85 Před 7 měsíci

      I have uploaded what I had. Others are lost forever... Sorry 😬

  • @rabahbelmiloud4194
    @rabahbelmiloud4194 Před 7 měsíci

    its been a long time Mndagause , where is your old youtube channel, i used to flow every video you make, it was full of videos,

  • @hamidkhar6857
    @hamidkhar6857 Před 8 měsíci

    I like your work

  • @othmanothman1116
    @othmanothman1116 Před 8 měsíci

    👏👏👏

  • @abderaoufsetti9368
    @abderaoufsetti9368 Před 8 měsíci

    welcome back sir , we missed your videos ☺

  • @MantasAutomation
    @MantasAutomation Před 9 měsíci

    Labai patinka tavo video, pats labai dažnai randu ką pasimokyti ir pritaikyti projektuose! Turiu ir keletą klausimų. Pastebėjau, kad dažnai nenaudoji komunikacijų VFD valdymui - gal taip pigiau, nes galima atsisakyti komunikacijos modulių ir pan., tačiau ženkliai sumažintų montavimo darbus. Dar įdomu dėl EMI/RFI filtrų VFD įėjime - kodėl jų nenaudoji? Gal taip pat dėl kainos ar tiesiog nereikalauja užsakovas?

    • @mindaugasv85
      @mindaugasv85 Před 9 měsíci

      Labas, Su komunikacija (RS485, modbus) gana nepatikima - jei daugiau VFD tai lagina duomenų perdavimas. Kai kuriuose procesuose tai kritiškai svarbu. Kažkada ir su Elinta tuo klausimu kalbėjau - sakė ir jų inžinieriai VFD valdo per diskretinius, per komunikaciją tai nebent greičius nusisiunčia iš anksto užduotus, seka apkrovas ir t.t... Nu toks RS485 modbus principas - per vieną užklausą tik kelis wordus gali nusiųsti/gauti. CanOpen, Ethercat, Profinet... tų problemų neturi. Bet tuo pačiu tai papildomi pinigai įrangoje (PLC, VFD). O gedimo atveju su diskretiniais greičiau susitvarkoma - galima ir kitą VFD modelį panaudot. Retai kas tuos filtrus ant įėjimo stato, čia jau kai problemų atsiranda, tai tada pradeda ieškot tų sprendimų, ko pasekoje ir filtrai atsiranda. Pagal ES direktyvas, "filtravimas" privalo būti, kad neterštų įvadinio tinklo. Nors kai kurie VFD tuos filtrus turi integruotu, bet turbūt ne biudžetinė klasė. Šiaip seniai tuo klausimu besidomėjau: tiesiog uždariau vieną dieną tą klausimą - likau prie to standartinio "kai atsiras poreikis, tai įdėsiu". Didžioji dalis projektų yra klientų sprendimai: tokia ir tokia įranga ir t.t... Ir visi taupo. T.y. aš daugiausiai dirbu su tais, kurie gamina įrenginius, o ne galutiniais vartotojais. Tai dažniausiai jie jau žino*** ko reikia 😁

  • @SvenEdits
    @SvenEdits Před 9 měsíci

    wow your control cabinets look like they do here in Germany 😍 good video

    • @mindaugasv85
      @mindaugasv85 Před 9 měsíci

      Thank you! P.S. I assembly them in garage 😅

  • @Ahmed-sv1zr
    @Ahmed-sv1zr Před 10 měsíci

    Nice

  • @mahercontrol5696
    @mahercontrol5696 Před 10 měsíci

    Hey, you guys have any other channels. I'm looking for your old movies.

    • @mindaugasv85
      @mindaugasv85 Před 10 měsíci

      Hi, Old channel has been deleted ~2 years ago. Sorry for that... I only have 3 old videos, 2 of them are uploaded (cba5, cba6). The last one is modbus rtu vs ascii - data lag test. I will upload it asap. What videos are you looking for?

    • @mahercontrol5696
      @mahercontrol5696 Před 10 měsíci

      ​@@mindaugasv85 I was so upset that all your movies were beautiful.😢😢

    • @mahercontrol5696
      @mahercontrol5696 Před 10 měsíci

      @@mindaugasv85I'd love to see those films again.

    • @mindaugasv85
      @mindaugasv85 Před 10 měsíci

      Can't do anything now: I uploaded everything I had. The good thing is that the channel is here and I'm going to make more videos 😉

    • @mahercontrol5696
      @mahercontrol5696 Před 10 měsíci

      @@mindaugasv85 Hi. Thank you, my friend.

  • @SvenEdits
    @SvenEdits Před 10 měsíci

    nice video where are you from?

  • @boolve
    @boolve Před 11 měsíci

    At 2:20 you mentioned you have got a double stop button. Is it because of some sort of backup circuit or it really does disable other parts of the system? And what is the reason that you have removed the second set of contacts in your demonstration?

    • @mindaugasv85
      @mindaugasv85 Před 11 měsíci

      It's safety system (cat2, 3 or 4). That means e.stop should work if one contact fail and it will be not possible to activate it until you will not fix it. So I have removed 1 contact because I needed to keep it in closed state - failure simulation.