Top Load Washing Machine dL Erorr Code. #lg
Error DL means that your door lock has failed. Whether you hear the lock trying to latch or not, the latch will need to be replaced to fix this problem. It's actually a fairly easy part to replace.
zhlédnutí: 25

Video

Troubleshooting : Emergency stop button #perkins
zhlédnutí 205Před měsícem
The button safely shuts down all power, including uninterruptable power supplies, batteries and generators from a central location. EPO buttons can be found in places such as manufacturing plants, telecommunications facilities and IT data centers.
How To Troubleshoot Fuel In Oil Contamination . Diesel engine...
zhlédnutí 203Před 2 měsíci
Fuel dilution can decrease oil viscosity and lubricity even at very low levels, increasing both bearing wear and the potential for bearing failure.
How to install an oil seal correctly.
zhlédnutí 846Před 2 měsíci
Oil seal: how to install it correctly 1: Preparing the oil seal installation. 2: Remove the old oil seal. 3: Select the correct oil seal size. 4: Check the materials and surfaces. 5: Clean the surfaces. 6: Use the right assembly tools. 7: Assembling the oil seal.
How to fix a leaking mini split AC, With simple tools in your home depot.
zhlédnutí 135Před 2 měsíci
One of the most common causes of leakage is clogged drainage. The culprit can be dirt, dust, and fungus that block the water to flow. The water will try to find the other way out, causing the AC to leak. If you let this problem sit for too long, this may cause a breathing problem.
The symptoms of a bad injection pump #perkins
zhlédnutí 442Před 3 měsíci
Here are the symptoms to look out for when you suspect there are issues with your engine's injection pump: -Hard starting. -Reduced engine power. -Increased fuel consumption. -Visible increase in exhaust smoke. -Misfiring.
5 Reasons why your air-conditioner is not cooling well, #airconditioning
zhlédnutí 384Před 5 měsíci
There are a number of reasons why your air conditioner might be running but not cooling. It could be an issue with the thermostat, the compressor, or the evaporator coils. Or, it could simply be clogged with dust and debris, which is preventing it from working properly.
Engine Oil Pressure Sensor Wiring 1103/1104 Series #perkinsfamily
zhlédnutí 1,8KPřed 7 měsíci
An oil pressure sensor is a simple device that sends signal to the Genset controller This is a very simple device made up of a spring-loaded switch and a diaphragm. The diaphragm receives oil and is designed to stay open at a set pressure level.
A Bad Oil Pressure Sensor's Symptom #perkinsfamily
zhlédnutí 953Před 8 měsíci
An oil pressure sensor is a device used to measure the oil pressure on an engine. Oil pressure sensor is actually a term that covers at least two different and distinct types of sensor - an oil pressure switch and and oil pressure sender.
12 Volts Relay Test & Wiring #diy .....
zhlédnutí 691Před 9 měsíci
12 VOLTS RELAY : These relays are an optimal solution for full voltage applications on a variety of vehicle equipment including head lamps, auxiliary lamps, fog horns, motors for fans, window lifters, air conditioners, heated rear windows, and in diesel generator it is used to control the starter motor & the fuel cutt soleniod.
Understanding SPN & FMI Fault Codes. #spn #fmi
zhlédnutí 3,2KPřed 9 měsíci
SPN is short for suspect parameter number. It identifies which electrical circuit, part or component of your generator isn't working properly. FMI stands for failure mode identifier-this part of the fault code tells you what type of problem your generator has.
Engine Under Speed Shutdown SPN 190 FMI 1 Diagnoses.
zhlédnutí 3,5KPřed 9 měsíci
Engine Under Speed Shutdown SPN 190 FMI 1 Diagnoses.
PowerWizard Control Module Description #perkins
zhlédnutí 491Před 9 měsíci
PowerWizard Control Module Description #perkins
Engine failure to start due to a bad Relay #perkins
zhlédnutí 8KPřed 9 měsíci
Engine failure to start due to a bad Relay #perkins
How a starter motor works
zhlédnutí 183Před 11 měsíci
How a starter motor works
Unexpected engine shut down symptoms. #generator #1millionsubscribers
zhlédnutí 8KPřed rokem
Unexpected engine shut down symptoms. #generator #1millionsubscribers
CH 05 Error LG Dual Inverter Air-condition #ac #error #codes
zhlédnutí 43KPřed rokem
CH 05 Error LG Dual Inverter Air-condition #ac #error #codes
AC Refrigerant Pump Down
zhlédnutí 452Před rokem
AC Refrigerant Pump Down
How to Adjust Generator's Voltage ? #AVR #perkins
zhlédnutí 3,6KPřed rokem
How to Adjust Generator's Voltage ? #AVR #perkins
What Cause Engine Under Speed Shutdown on Generator #perkins
zhlédnutí 4,2KPřed rokem
What Cause Engine Under Speed Shutdown on Generator #perkins
How to Clean Properly an Air-condition's Evaporator. #lg #ac #maintenance
zhlédnutí 855Před rokem
How to Clean Properly an Air-condition's Evaporator. #lg #ac #maintenance
Crankshaft Position Sensor Test #toyota #crankshaft #positions #sensor
zhlédnutí 2KPřed rokem
Crankshaft Position Sensor Test #toyota #crankshaft #positions #sensor
LG Top Load Washing Machine Error Codes & Maintenance.. #lg #topload #washing #machine
zhlédnutí 4,2KPřed rokem
LG Top Load Washing Machine Error Codes & Maintenance.. #lg #topload #washing #machine
How to Properly Recharge Your AC System
zhlédnutí 672Před rokem
How to Properly Recharge Your AC System
This simple outdoor unit cleaning will extend compressor's life
zhlédnutí 4,5KPřed rokem
This simple outdoor unit cleaning will extend compressor's life
photocell sensor connection with a contactor.
zhlédnutí 163Před rokem
photocell sensor connection with a contactor.
Simple Car Maintenance to Prevent Expensive Repairs
zhlédnutí 220Před rokem
Simple Car Maintenance to Prevent Expensive Repairs
Generator Starting problems and troubleshoot
zhlédnutí 42KPřed rokem
Generator Starting problems and troubleshoot
Toyota Hardtop Land Cruiser Cabin Air Filter Mesh Cleaning
zhlédnutí 1,4KPřed rokem
Toyota Hardtop Land Cruiser Cabin Air Filter Mesh Cleaning
Generator's engine speed sensor problems and symptoms
zhlédnutí 9KPřed rokem
Generator's engine speed sensor problems and symptoms

Komentáře

  • @mariadecampus2759
    @mariadecampus2759 Před 4 dny

    Come Si imposta la temperatura nel telecomando????

  • @piotrmarg7126
    @piotrmarg7126 Před 13 dny

    1mm is in lg manual

  • @PatrickKitarepakei
    @PatrickKitarepakei Před 16 dny

    Why rpm for 4pole genset is 1678 and not 1500

    • @northjayhoon9789
      @northjayhoon9789 Před 13 dny

      4 pole 230 V 50 Hz. RPM 1500 4 pole 120/110 V 60 Hz. RPM 1800 Run the genset check the frequency and correct the RPM.

  • @Automation_workshop
    @Automation_workshop Před 19 dny

    Hi dear, We have a Cummins generator, it trips on overspeed alarm, what could be the cause? Fuel SOV relay is okay, starter is okay, we could not figure out where is the problem.

    • @northjayhoon9789
      @northjayhoon9789 Před 19 dny

      Greetings ! Could you please give further information ? Is this Genset overspeed at first start, or any time when you crank it overspeed?

    • @Automation_workshop
      @Automation_workshop Před 18 dny

      @@northjayhoon9789 every time when we start the gen set trip on over speed, over speed setpoint is 1650, speed probe is healthy, engine trips during cranking

    • @northjayhoon9789
      @northjayhoon9789 Před 18 dny

      Thank you for your info, Your Genset RPM should be 1500, Your generator voltage 230 volts and 50Hz at 1500 RPM If you don't have any issue with fuel line and injection pump, your engine RPM should remain the same rpm ,even after loading In this case adjust the engine RPM at 1550 and then load the genset see if the engine RPM remain at 1500 if so! your problem solved.

  • @isrealbronco9639
    @isrealbronco9639 Před 22 dny

    Thank you for your indept explanation , it is very informative

  • @talhazubair2904
    @talhazubair2904 Před 25 dny

    Sir i have question Kindly help me to crack of my question. I am an Electrical Engineer and working on Caterpillar generator G3520H model, One day there was a fault on it about *kw sensor* so I could not troubleshoot, so what could be the fault? Where should troubleshooting be done?

    • @northjayhoon9789
      @northjayhoon9789 Před 25 dny

      Greetings Thank you for your inquiries I'm wondering if you could tell me about your Genset controller First I need to know about Genset controller and then we need to finde the event code , after that I can tell you what problem you have with your generator.

    • @talhazubair2904
      @talhazubair2904 Před 25 dny

      @@northjayhoon9789 deep sea electronics DSE 8610 MKH

    • @talhazubair2904
      @talhazubair2904 Před 25 dny

      @@northjayhoon9789 Engine all parameter shown on ( Enercon Simatic HMI)

    • @northjayhoon9789
      @northjayhoon9789 Před 24 dny

      Kw fault code can be displayed on generator overview It tells us the generator was overloaded Calculate the current on generator overview parameters when it is fully loaded and then check the maximum current shown at your Genset ,if it is loaded 100% which mean you need to reduce the load It should not be load more than 80%

    • @talhazubair2904
      @talhazubair2904 Před 24 dny

      Thanks a ton Sir.

  • @talhazubair2904
    @talhazubair2904 Před 25 dny

    Thank you mate

  • @CholMonytwic
    @CholMonytwic Před měsícem

    Very interesting, i wish if you can help me to do the connection of socket next time.

  • @venkatesanmahalingam9865
    @venkatesanmahalingam9865 Před měsícem

    Hi sir, useful and informative

  • @electricalrme2267
    @electricalrme2267 Před měsícem

    Hello sir I have her a Perkins diesel generator. As I can see there are two Magnetic Pick-Up mounted in the unit. The Injection Pump has a logic control governor (LCG) and the generator is also controlled remotely which is used for synchronizing to other generator. My question is why there are two MPU installed?

    • @northjayhoon9789
      @northjayhoon9789 Před měsícem

      Greetings! Thank you for your enquiries. You got 2 MPU , one of the sensor is responsible for your starter motor while you cranking the engine, as soon as the engine starts the sensor sends the signal to the GSC the GSC cuts the power on starter motors relay meanwhile the starter motor disengage. The second MPU is monitoring the engine speed when you loading the generator the RPM drops and the GSC (Genset Controller) accelerate the engine through the LCG. However some engines have only one MPU but twin are more reliable.

  • @electricalrme2267
    @electricalrme2267 Před měsícem

    Great!

  • @AnsphilNuyikre
    @AnsphilNuyikre Před měsícem

    My problem for genset is not cranking sir

    • @northjayhoon9789
      @northjayhoon9789 Před měsícem

      Check your battery voltage make sure it is fully charged otherwise you have problem either with starter motors solenoid or relay please click on this link watch this video it could solve your problems. czcams.com/video/W8UOMo2-gVE/video.htmlsi=nSVv097Oid6tu8Uj

  • @IbrahimKarrosesay
    @IbrahimKarrosesay Před měsícem

    The tutorial is well explained. Can you please do a tutorial where you can make full connection from the gen controller and the entire circuit step by step with all components involved in the circuit.

    • @northjayhoon9789
      @northjayhoon9789 Před měsícem

      Thank you for your enquiry ! Will try with another video.

  • @alx.8721
    @alx.8721 Před měsícem

    Ohm’ing out an electrical part by its connector (wiring) is not the most reliable, but ahh, it’ll do.

  • @abdallamwareje2920
    @abdallamwareje2920 Před 2 měsíci

    ❤❤

  • @abdallamwareje2920
    @abdallamwareje2920 Před 2 měsíci

  • @abdualkadershuga1163
    @abdualkadershuga1163 Před 2 měsíci

    Hello my dear friend, I have a problem with a Caterpillar C18 generator, 500 kilowatts. After the generator is started without load, there is a problem with the speed and voltage stabilizing together, with a humming sound occurring in the generator. It is unstable. Please help me. Many thanks and respect to you.

    • @abdualkadershuga1163
      @abdualkadershuga1163 Před 2 měsíci

      Please, can you give me your WhatsApp number so I can send you a video clip of this problem

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      Greetings Thank you for your enquiry! Can you tell me about RPM and the voltage in your country? If the voltage is 110 v 60Hz the RPM should be 1800 for 220 v 50Hz the RPM should be 1500. First make sure stabilize your engine speed , either there is problem with your fuel line or the injectors are bad . 01 Check the fuel line and the pump pressure . 02 inspect the injectors . If they are all ok Do a compression test make sure you don't have any problem with your engine after inspection when you got all ok the engine speed stabilized , check the voltage if still the voltage fluctuating please check the AVR.

    • @abdualkadershuga1163
      @abdualkadershuga1163 Před měsícem

      the RPM 50/52/48 And Voltage 400/420/389/380

    • @abdualkadershuga1163
      @abdualkadershuga1163 Před měsícem

      Speed ​​and voltage are unstable

  • @badoui
    @badoui Před 2 měsíci

    How to problem alarem high volteg battrie ....?

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      Thank you for your enquiry! If your generator's controller indicates/ warning high battery alarm, definitely you need to check DC alternator . An alternator's output is controlled by an integrated voltage regulator, which is designed to prevent overcharge. You may have a faulty voltage regulator and it does over charge your battery.

  • @user-xf9ov9vb2n
    @user-xf9ov9vb2n Před 2 měsíci

    Very helpful, thank you

  • @sylviahoffmann3614
    @sylviahoffmann3614 Před 2 měsíci

    THIS ID THE HORROR .NO FILTERS INDISE???

  • @electricalrme2267
    @electricalrme2267 Před 2 měsíci

    Thanks Sir. Please upload more troubleshooting videos.

  • @electricalrme2267
    @electricalrme2267 Před 2 měsíci

    Thank you

  • @electricalrme2267
    @electricalrme2267 Před 2 měsíci

    Thanks your videos help me a lot

  • @electricalrme2267
    @electricalrme2267 Před 2 měsíci

    Very informative

  • @KosibaZso
    @KosibaZso Před 2 měsíci

    OMG. Thankyou for your video!!! I saved 150 dollars cuz if it. I could easily take apart and clean my machine as i followed you. It was full of mold. I could clean it totally, and now i can enjoy it to the fullest. 😊😊 Thanks for your work.

  • @Blackadar56
    @Blackadar56 Před 2 měsíci

    Just what I was looking for. Thank you 🙏

  • @tomicooltomi
    @tomicooltomi Před 2 měsíci

    Helped a lot, thank you

  • @debeoderoolawale4109
    @debeoderoolawale4109 Před 2 měsíci

    great what if the wire is good yet the communication is signal

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      Greetings If you have already check the wires : L N 3c Ground The next step is to check all components at the PCB in the outdoor unit if everything looks good at the outdoor next check the PCB board at the indoor units.

  • @elcolibri1971
    @elcolibri1971 Před 2 měsíci

    Thanks sir 🔧,I had already checked that filter and I think the problem is with the lift pump, a few months ago the tank was contaminated, the injection pump and injectors were serviced but nothing has been done to the lift pump

  • @elcolibri1971
    @elcolibri1971 Před 2 měsíci

    Hello, I am having the same problem with a generator similar to the one you are calibrating the sensor, it has a new sensor, calibrated, and the failure continues, loss of signal or erratic speed sensor, what could be happening there if the problem remains the same

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      Greetings If you have replaced the sensor and still have the same problem please check those two wires which connected to the sensor either there is loose connection or one of the wire has been corroded. Note:for loose connection you need the inspect the sensor connector If there is loose connection engine vibrations will cause loose the signal.

    • @elcolibri1971
      @elcolibri1971 Před 2 měsíci

      @@northjayhoon9789 Hello, thank you for your information, I replaced the harness by making a new one other than the one it came with and it continues to present the problem, I believe that the problem is caused by the fuel, I notice that the engine slows down as the load of each section of the hotel where it is installed. Sometimes you have to turn it on up to 3 times for it to start.

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      czcams.com/video/w1UhNIMYeYM/video.htmlsi=S4d7-yv3ClUAHSOE

  • @shoaibsheikh7741
    @shoaibsheikh7741 Před 3 měsíci

    My engine has similar problem, unexpected shutdown! But when i restart the engine it starts normal. However only during the change in load it shut downs! Wht it could be ? I already inspected fuel side. Thank you.

    • @northjayhoon9789
      @northjayhoon9789 Před 2 měsíci

      Greetings Unexpected shutdown is an electrical problem, it happens if there is loose connection where the negatives circuits are grounded at the engine, or there is power interruption happens with circuit which is supplying power to the fuel cut solenoid .

    • @shoaibsheikh7741
      @shoaibsheikh7741 Před 2 měsíci

      @@northjayhoon9789 appreciated sir!

  • @fifteen15k48
    @fifteen15k48 Před 3 měsíci

    Hello boss I from Ghana 🇬🇭 my LG Ac giving me CH05 too

  • @antoniogonzalezmedel
    @antoniogonzalezmedel Před 3 měsíci

    My FGWilson trip in the First start by overspeed... In the second start no problem... I gona Check my filter of pump. Thanks Mr.

    • @northjayhoon9789
      @northjayhoon9789 Před 3 měsíci

      Greetings First start overspeed means there is a problem with the fuel line The fuel from filter housing returns back to the fuel tank after some hours , while the generator is standby In this situation before you start the engine please run the prime pump for two minutes and start the engine , if the engine did not overspeed which mean the fuel line gets empty when it is standby for two or three hours Note: if your generator doesn't have an electric fuel prime pump Pump it manually.

  • @christopherfadera763
    @christopherfadera763 Před 3 měsíci

    Big help for us. Thank you sir 🙏

  • @christopherfadera763
    @christopherfadera763 Před 3 měsíci

    Sir, can I ask for a wiring diagram of the same unit. Our unit at site is P200-2. We have a problem with our fuel solinoid voltage supplies.no voltage showing whilst starting and engine won't start. Thank you sir

    • @northjayhoon9789
      @northjayhoon9789 Před 3 měsíci

      Greetings Thank you for your request Please send me an email to north.jayhoon@gmail.com I will send you the wiring diagram. All the best

  • @christopherfadera763
    @christopherfadera763 Před 3 měsíci

    Hello sir.new subcriber.

  • @richardconsuelo2998
    @richardconsuelo2998 Před 4 měsíci

    How about the engine local connectivity shutdown.how to resolve

    • @northjayhoon9789
      @northjayhoon9789 Před 3 měsíci

      Could you please tell further about local connectivity? Is this generator running as a backup?

  • @saeedalali9551
    @saeedalali9551 Před 4 měsíci

    Thanks to you My dear ❤

  • @prannoytej7180
    @prannoytej7180 Před 4 měsíci

    What about the outside unit? The compressor?

    • @northjayhoon9789
      @northjayhoon9789 Před 4 měsíci

      czcams.com/play/PL9emt8gEX58R2R3CcxGHMFyQPt58M_vu1.html&si=unLxtPszQY8-ymuQ

  • @walidkamal266
    @walidkamal266 Před 4 měsíci

    good job

  • @djisydneyaustralia
    @djisydneyaustralia Před 4 měsíci

    Well done sir, nice diagnostic procedure

  • @antoniogonzalezmedel
    @antoniogonzalezmedel Před 4 měsíci

    Congratulations 🎉

  • @antoniogonzalezmedel
    @antoniogonzalezmedel Před 4 měsíci

    The wires are to trash

    • @northjayhoon9789
      @northjayhoon9789 Před 4 měsíci

      Thank you for your consideration This is a 12 years old generator the previous service providers screws up everything We have been trying to fix them.

  • @riyaan1993
    @riyaan1993 Před 4 měsíci

    hi there..same issue for my ac as well.. all wires are fine... ac works for few mins, and then ch 5 erro comes up.. sometimes ac works without any issues, but then the next day, sane error pops up.. what couls be the issue? and today its been 3 days i havent used the ac..its not starting at all

    • @northjayhoon9789
      @northjayhoon9789 Před 4 měsíci

      Greetings Check the input circuits at the indoor PCB make sure they are ok you may have a blown fuse once you figure out with the current problem that you mentioned your AC is off at all not starting After you are able to run the unit connect a single wire to the 3c circuit in indoor and the other end of wire should reach to the outdoor connect it to the 3c circuit of outdoor this wire should be isolated from the rest of wire Run the AC unit and wait 20 mins if the erro comes back then you need to check the PCB board at the outdoor there are so many component you have to check sometimes the PCB itself goes bad

    • @andywong1782
      @andywong1782 Před 2 měsíci

      Hi, you found the problem yet? I have the exactly issue like you. I haven't checked the wire yet. Ch05 shown up occasional after 30 min or so. After I turned off everything for any hour or so, it will be back to normal, depending on luck.

  • @lakewbiru3225
    @lakewbiru3225 Před 5 měsíci

    please adding schematic diagram &wiring

  • @northjayhoon9789
    @northjayhoon9789 Před 5 měsíci

    czcams.com/video/OkRnR5NB2wg/video.htmlsi=GQbtChnnCcetiEQe

  • @northjayhoon9789
    @northjayhoon9789 Před 5 měsíci

    czcams.com/video/OkRnR5NB2wg/video.htmlsi=GQbtChnnCcetiEQe

  • @NashonJohn-eq7of
    @NashonJohn-eq7of Před 5 měsíci

    Thanks sir .very informative

  • @joelty250
    @joelty250 Před 5 měsíci

    Very helpful Sir. Thank you

  • @OyetundeDavidOyeyemi
    @OyetundeDavidOyeyemi Před 5 měsíci

    This is an excellent test carried out, simple and straightforward