TerraBuddy
TerraBuddy
  • 15
  • 7 292
CHEESE MAGGI RECIPE
INGREDIENTS
Vegetables: Onion, green chillies, garlic, capsicum & tomatoes.
Spices: Salt, red chilly powder, dhania powder, oregano & red chilly flakes.
Cheese: Amul cheese
Noodles: Obviously Maggi !
zhlédnutí: 5

Video

CPR PART 2 ● PRACTICAL DEMONSTRATION
zhlédnutí 49Před 4 hodinami
The CPR Procedure is demonstrated on a mannequin. Disclaimer: This is not medical advice. It is only for information.
CPR PART 1 ● BASIC INFORMATION
zhlédnutí 14Před 4 hodinami
CPR stands for cardiopulmonary resuscitation, which is a life-saving emergency procedure that's performed when someone's breathing or heartbeat has stopped. It can be used to help someone who is in cardiac arrest, when their heart isn't beating effectively or has stopped beating. Before performing CPR on an adult, use the following preparation steps: Step 1. Call for Ambulance (108 - for INDIA)...
SNAKE RESCUE PROCESS ● By professional snake catchers ● INDIAN COBRA
zhlédnutí 560Před 4 hodinami
The snake shown in this video is the INDIAN COBRA. The snake got trapped inside the security room and could not go anywhere else, this made it easy for the snake catchers to trap it easily. No person or animal was hurt during this operation. The snake was carefully left in the forest afterwards.
Multilin D60 DP (Distance Protection) Relay Fault Report Cheecking Process.
zhlédnutí 29Před 14 dny
In all types of GE Multilin relays the Fault Reports are under "Actual Values" Menu.
ABB REF615 Relay Fault Report Checking Process
zhlédnutí 158Před 14 dny
ABB REF615 Backup Relay: Fault Current = Multiplication Factor (obtained from relay) X CT ratio. For eg: If Multiplication factor is 1.2 and CT ratio is 400/1, then - Fault current is 1.2X400 = 480Amps. NOTE: In these kind of relays the indication LEDs and Programmable LEDs need to be reset first, after a fault, before attempting to close the breaker.
Micom ALSTOM DP Relay | P40 Agile | Fault Record viewing process.
zhlédnutí 84Před 14 dny
The process is similar for P444, P442, P141 and similar Micom ALSTOM Relays.
MCUBE GUIDE PART 2
zhlédnutí 21Před 2 měsíci
Weekly Data collection procedure.
MCUBE GUIDE PART 1
zhlédnutí 27Před 2 měsíci
Weekly Data compilation procedure.
Mast Instant Coffee Recipe
zhlédnutí 28Před 5 měsíci
Energize yourself with this instant coffee made just under 5 minutes !!!
ID Creation for Biometric
zhlédnutí 42Před rokem
ID Creation for Biometric
Dissolved Gas Analysis Test of Transformer Oil | GE Transport X2 DGA Test Kit
zhlédnutí 3,8KPřed rokem
The Kit used in the Video is GE Make Transport X2. It is a portable Dissolved Gas Analysis (DGA) and moisture monitoring system for analysing insulating fluids. It uses photo-acoustic spectroscopy (PAS) technology to obtain measurements of critical gases. The product measures 7 fault gases: Hydrogen Methane Ethane Ethylene Carbon Dioxide Carbon Monoxide Acetylene & Moisture Levels.
How to put a VERTICAL BAR in-between text
zhlédnutí 2,6KPřed 3 lety
In most modern keyboards the vertical bar is present in-between the 'Enter' key and the 'Backspace' button. In some cases it may be present on the left of the 'Enter' Key or the 'Z' Key.