Defective Siemens 200 Amp Main Circuit Breaker
Not a common occurrence to have a Siemens 200 Amp Main Circuit Breaker be mechanically defective. All in a days work. #electricianlife⚡️ #200ampservice #defective #main breaker #lovewhatyoudo Not a common occurrence to have a Siemens 200 Amp Main Circuit Breaker be mechanically defective. All in a days work. #electricianlife⚡️ #200ampservice #defective #mainbreaker #lovewhatyoudo
zhlédnutí: 8 122

Video

Kristina hard at work
zhlédnutí 22Před 4 lety
This amazing woman is terminating a new circuit for an outdoor deck receptacle
Electrical House Wiring Mount Airy Philadelphia PA
zhlédnutí 168Před 4 lety
This is Krisitina drilling through a 100 year old stone wall. This is one part of the process in rewiring the 2nd floor of a house in the Mt. Airy section of Philadelphia. Call us today! taselectricllc.com/electrical-panel-and-service-upgrade/ Electrician House Rewiring Mount Airy Philadelphia PA - czcams.com/video/O2QgJI3WYgk/video.html If you are looking for Electrician House Rewiring Mount A...
Electrical Contractor Electrical Panel upgrade in Trooper PA
zhlédnutí 46Před 4 lety
Did an electrical rewire for a house in Trooper PA. The Electrical Panel got a 200amp upgrade . Call us! 267-242-1009 taselectricllc.com/electrical-contractor-electrical-panel-upgrade-in-trooper-pa/

Komentáře

  • @davidmatias6239
    @davidmatias6239 Před měsícem

    can a Main breaker be repaired? I have a Murray Crouse 200amp breaker that the switch is not snapping in place and seems loose after powering it back on. a new one is around $1200 bucks.

  • @markrobinson8539
    @markrobinson8539 Před měsícem

    Thank you for a sanity check..I just bought a brand new 40 space Siemens PN panel Siemens SN4060B1200 and the main breaker won't lock over to the ON position. I checked the breaker with an ohmeter and the main breaker switch stays open circuit. It didn't come with machine screws to attach the front panel to the back piece either.

  • @geronimot5133
    @geronimot5133 Před měsícem

    What is a good substitute for a Siemens 200 amp main breaker

  • @John34.
    @John34. Před 4 měsíci

    So, hopefully, not a difficult question. Im looking at installing an interlock system in my panel, which is in the garage. This will include a 30amp inlet wall plug for the solar generator to bring power to the panel. The problem is that my main breaker is on the outside of the garage with the power company meter. My panel in the garage has a main breaker punch out. I found one on Amazon for Siemens panel. It's a 200amp double pole breaker with one switch. Would this work. I've attached a link to amazon to show what im talking about. It also comes with the 30amp breaker that would be for the solar generator, and the interlock kit will sit between the main 200amp breaker and this 30amp breaker. Also, do you know how much electricians usually would charge for installing the main breaker in the panel. It doesn't look hard. I just dont want to void any homeowners insurance by doing electrical myself. Hopefully, not thousands. Siemens MBK200A 200-Amp Main Circuit Breaker for Use in Ultimate Type Load Centers & Q230 30-Amp Double Pole Type QP Circuit Breaker a.co/d/i4y1MVN

  • @danielhuynh01
    @danielhuynh01 Před 7 měsíci

    Hi, can I replace the 200 amp main breaker with a 100 amp? Thank you, and have a nice day

  • @charliesmith9528
    @charliesmith9528 Před 8 měsíci

    I have a simens breaker panel inside my manufactured home..main is getting very hot or trips sometimes when i run heat pump for a long time,,is it bad main or heat pump compressor

  • @Scott-eu1zv
    @Scott-eu1zv Před 8 měsíci

    Nice job. 😊

  • @pimptasticone
    @pimptasticone Před rokem

    Looks like my 20yo Siemens breaker won't move to the Off position....so guess I'll need to run down. Good news is it looks like this is an easy swap minus finding the breaker and of course any permit needed. Thanks for the video!

    • @taselectric8206
      @taselectric8206 Před 11 měsíci

      turn off all of the other breakers, then if you are able to pull the meter in your area without calling the power company, pull it. Check to make the wires feeding the main breaker are dead. You should need a flat head screwdriver, an Allen-key(not sure what size) and a socket either a 7/16 or 1/2 inch. And finally use noalox on the wires when putting them back into the breaker. It is good practice. If you have any questions, we can be reached on Instagram @taselectricllc

    • @pimptasticone
      @pimptasticone Před 11 měsíci

      @@taselectric8206 thanks. I was able to get the part but checking on permits and power company; new smart meters have a security tag on them.

  • @lupefiasco3159
    @lupefiasco3159 Před rokem

    You need a closeup of how your doing it. Its hard to see with you standing IFO the panel and the shadows don't help. Just saying...

    • @taselectric8206
      @taselectric8206 Před rokem

      Pull the meter, loosen the lugs for the wire, remove the bolts that hold the breaker to the bus and remove breaker. Installation is in reverse