HVAC - Learn about Enviromental Monitoring System for clean rooms in Pharma
zhlédnutí 102Před 9 měsíci
Mistakes in calibration and validation of medical equipment or systems that keep the facility compliant can be avoided is common sense is applied when the standard operation procedures are written by unprofesional or not qualified people.
Learn from A to Z how the AHU is controlling the tempertuare and humidity in clean rooms
zhlédnutí 370Před 9 měsíci
Learn from A to Z how the AHU is controlling the tempertuare and humidity in clean rooms
HVAC free materials for HVAC trainers partialy explained faults and design errors
zhlédnutí 114Před 9 měsíci
This materila is partialy explained allowing the trainers to show to students issues related to AHus errors in design . This materials covers heat exchangers air flow and AHU's errors in design. Also the control philosophy is touched .
PART 3 LEARN ABOUT COMPLETE AHU'S TEMEPRATURE AND HUMIDITY CONTROL STRATEGY ANALYSES
zhlédnutí 68Před 9 měsíci
PART 3 LEARN ABOUT COMPLETE AHU'S TEMEPRATURE AND HUMIDITY CONTROL STRATEGY ANALYSES
PART 2 LEARN ABOUT COMPLETE AHU'S TEMEPRATURE AND HUMIDITY CONTROL STRATEGY ANALYSES
zhlédnutí 96Před 9 měsíci
Watching this you will understand that cooling heat exchangers which are using chilled water of glycol rely on the chilled water's temeprature to cool or dehumidify the air .
PART 1 LEARN ABOUT COMPLETE AHU'S TEMEPRATURE AND HUMIDITY CONTROL STRATEGY ANALYSES
zhlédnutí 73Před 9 měsíci
LEARN HOW TO INVESTIGATE ahu'C CONTROL STRATEGY , ANALYSE THE DESIGN AND EVALUATE ITS CAPACITY. aT THE END OF THIS COURSE YOU WILL NEVER BE FRUSTRATED EVER AGAIN IF YOU ARE REQUIERED TO REPAIR AN INCORECT DESIGNED SYSTEM tHAT WILL KEEP YOUR JOB SAFE.
HVAc AHU and heat exchanger capacity analyses and errors in design identification.
zhlédnutí 144Před 9 měsíci
This video is meant to explain mistake done bu designers , incorect control philosophy and issues related to lack of AHU understanding. This video if understood will make you a better HVAC engineer.
Understand in Pharma Industry AHUs that are not recirculating the air in clean rooms .
zhlédnutí 256Před 9 měsíci
There are many design errors . If you are a technician do not blame your self if the system is not working well before to understand how it shoulod work . I came across a lot of lies , manipulation , ignorance and careless from many companies heads . Believe in your self . Do the best from your heart . Be proud and honest. Do not kneal in front of people which have the talent to make you guilty...
Learn how to investigate HVAC electrical motor overloads and contactors in few minutes
zhlédnutí 187Před rokem
Learn how to investigate HVAC electrical motor overloads and contactors in few minutes
Syncronicity and precision makes things run smoothly unlike politicians or other entities that are s
zhlédnutí 41Před rokem
Syncronicity and precision makes things run smoothly unlike politicians or other entities that are s
Learn about electrical auxiliary control circuits and avoid electrocution danger in HVAC industry
zhlédnutí 293Před rokem
Learn about electrical auxiliary control circuits and avoid electrocution danger in HVAC industry
Learn fast how to investigate electrical faults and avoid dangers related to borrowed neutrals.
zhlédnutí 302Před rokem
Learn fast how to investigate electrical faults and avoid dangers related to borrowed neutrals.
Learn in 25 minutes How To Investigate Poorly or Incorrectly Designed Circuits In Domastic Or Comer
zhlédnutí 100Před rokem
Learn in 25 minutes How To Investigate Poorly or Incorrectly Designed Circuits In Domastic Or Comer
Learn in only 18 minutes to investigate and rectify electrical circuits faults in homes or offices
zhlédnutí 339Před rokem
Learn in only 18 minutes to investigate and rectify electrical circuits faults in homes or offices
HVAC AHU AIR CONTROL SIMULATION HELPS YOU TO UNDERSTAND THE AIR TRANSFORMATION WHEN PASING THE COILS
zhlédnutí 192Před rokem
HVAC AHU AIR CONTROL SIMULATION HELPS YOU TO UNDERSTAND THE AIR TRANSFORMATION WHEN PASING THE COILS
TRICS ABOUT HOW TO INVESTIGATE A PRESURISATION UNIT FAULT AND ITS EFECTS ON HEATING SYSTEMS
zhlédnutí 315Před rokem
TRICS ABOUT HOW TO INVESTIGATE A PRESURISATION UNIT FAULT AND ITS EFECTS ON HEATING SYSTEMS
LEARN FAST HVAC PRESSURISATION UNITS AND PRESSURE VESSELS ISSUES OR HIGH PRESSURE PROBELMS IN HEATI
zhlédnutí 1,4KPřed rokem
LEARN FAST HVAC PRESSURISATION UNITS AND PRESSURE VESSELS ISSUES OR HIGH PRESSURE PROBELMS IN HEATI
HVAC SUMP pump control investigation ,relays ,control box and transition to PCBs and PLC,s or BMSs
zhlédnutí 278Před rokem
HVAC SUMP pump control investigation ,relays ,control box and transition to PCBs and PLC,s or BMSs
Understand how to investigate sump pumps circuits step by step Part 1
zhlédnutí 180Před rokem
Understand how to investigate sump pumps circuits step by step Part 1
SUMP PUMP CONTROL SIMULATION
zhlédnutí 110Před rokem
SUMP PUMP CONTROL SIMULATION
LEARN HOW TO SERVICE REPAIR OR DESIGN A SUMP PUMP CONTROL HVAC PART 1
zhlédnutí 132Před rokem
LEARN HOW TO SERVICE REPAIR OR DESIGN A SUMP PUMP CONTROL HVAC PART 1
HVAC OBSERVE THE ELECTRICAL SYSTEM TROUGH CUSTOMER EYES AND LEARN TO ANALYSE THE ELECTRICAL SYSTEM
zhlédnutí 70Před rokem
HVAC OBSERVE THE ELECTRICAL SYSTEM TROUGH CUSTOMER EYES AND LEARN TO ANALYSE THE ELECTRICAL SYSTEM
LEARN TO INVESTIGATE ,TROUBLESHOOT OR SERVICE CIRCUITS WITH LATCH RELAYS FOR HVAC EQUIPMENTS
zhlédnutí 195Před rokem
LEARN TO INVESTIGATE ,TROUBLESHOOT OR SERVICE CIRCUITS WITH LATCH RELAYS FOR HVAC EQUIPMENTS
LEARN TO INVESTIGATE ANALYSE ,DIAGNOSE AND REPAIR HVAC ELECTRICAL MOTOR CIRCUITS PART 2
zhlédnutí 166Před rokem
LEARN TO INVESTIGATE ANALYSE ,DIAGNOSE AND REPAIR HVAC ELECTRICAL MOTOR CIRCUITS PART 2
Learn to investigate , analyse diagnose and repair HVAC electrical motor circuits Part 1
zhlédnutí 141Před rokem
Learn to investigate , analyse diagnose and repair HVAC electrical motor circuits Part 1
Real HVAC Engineering ,,,Design and Build Customised AHUs to match clients demands....
zhlédnutí 260Před rokem
Real HVAC Engineering ,,,Design and Build Customised AHUs to match clients demands....
LEARN ABOUT HVAC AHU AIR CONTROL STRATEGY MOTORS AND DAMPERS IN LESS THAN 15 MINUTES
zhlédnutí 337Před rokem
LEARN ABOUT HVAC AHU AIR CONTROL STRATEGY MOTORS AND DAMPERS IN LESS THAN 15 MINUTES
Mitsubishi air conditioning cassette error code P5 .Condensate water eliminating issue .
zhlédnutí 4,4KPřed rokem
Mitsubishi air conditioning cassette error code P5 .Condensate water eliminating issue .
HVAC Understand air conditioning and learn to troubleshoot faults easily
zhlédnutí 120Před rokem
HVAC Understand air conditioning and learn to troubleshoot faults easily

Komentáře

  • @Deenibayanoriginal
    @Deenibayanoriginal Před 10 dny

    Sir how can i control rh and temp by using plc ??

    • @TechnicalChallenger
      @TechnicalChallenger Před 9 dny

      @@Deenibayanoriginal To control temperature and humidity by using a PLC you need to have a software downloaded on to the PLC and the PLC should have analog imputs and outputs . If your AHU have a heating ,cooling heat exchanger and humififier controlled by valves driven by actuators and your heat exchangers are using lycol or water then the PLC will control the T and RH by instructing the heat exchanger actuators to alow the heat exchangers to heat and cool acordingly to the setpoints . If you are using DX coil then you ca have as well capacity control etc . The humidity control is done by tne PLC only if the AHU is equipt with proper heat exchangers and actuators or other form of capacity control valves . You can act directly on compressors or gas boilers to control the heating cooling and RH considering that you also have a humidifier fitted in to your system .There are many ways to build a RH % control . Please watch my other videos about the RH% control .

    • @Deenibayanoriginal
      @Deenibayanoriginal Před 9 dny

      @@TechnicalChallenger sir in our ahu there is only chilled water valve and hot water valve and by using this I have to control rh and temperature

    • @Deenibayanoriginal
      @Deenibayanoriginal Před 9 dny

      Can you suggest me how can I make a ladder logic in my plc

    • @TechnicalChallenger
      @TechnicalChallenger Před 9 dny

      @@Deenibayanoriginal Dear Friend Are uou familiar with laddr logic ? What PLC or BMS are you using

    • @Deenibayanoriginal
      @Deenibayanoriginal Před 9 dny

      @@TechnicalChallenger sir I'm using delta plc and analog card for analog signals

  • @lmatheis
    @lmatheis Před 23 dny

    Hi there, I was hoping to connect and see if I could learn from you about my personal home system

  • @oluwafemimichael9253
    @oluwafemimichael9253 Před 28 dny

    What is the cost along with capacity

  • @sumitnagargoje1790
    @sumitnagargoje1790 Před 2 měsíci

    Hi Can you explain how circulating pump influence pressurisation unit operation? In your pressure gauge at return line near circulation pump you see pressure reading above 2 bar but your PRV is set at 2 bar Wouldn’t pressurisation unit start kicking in and adjust that pressure?

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 měsíci

      When pump start the return pressure is lower that the flow pressure . The presurizatiin unit follows the return pressure .When the pump is not running the only pressure difference is in between the lower and any higher point where the pressure is taken . When the pump is running the heating agent is on dynamic state . The presurisatiin unit is monitoring the retun pressure .

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 měsíci

      Also the presurissatiin unit show 1.5 bars and the return PRV is set at 2 bars . The flow PRV is set at 3 bars .

  • @londreseeu562
    @londreseeu562 Před 2 měsíci

    The best ever video about PU and the whole system. Thank you!

  • @BernardNelson-tp1mw
    @BernardNelson-tp1mw Před 3 měsíci

    Excellent training! Thanks for sharing your knowledge. I watched the video twice. I have been a hands-on HVAC engineer for 53 years but I am still learning.

    • @TechnicalChallenger
      @TechnicalChallenger Před 3 měsíci

      Thank you sir . I am also learning and I am still hands in tools. I am just sharing with my fellows engineers the daily issus I have when running trough HVAC systems .

  • @Charlesgoodeman
    @Charlesgoodeman Před 3 měsíci

    "A responsible HVAC engineer will only think with his heart, not with his mind, and this is the truth..." This got a chuckle out of me.

    • @TechnicalChallenger
      @TechnicalChallenger Před 3 měsíci

      At least an emotion have been born .Nothing happen if the potentiality remain just potentiality . Kindness makes an engineer more human .

  • @jumokebabatope
    @jumokebabatope Před 4 měsíci

    Thank you . Exactly what I was looking for

  • @Don-po1di
    @Don-po1di Před 5 měsíci

    Helpful thanks

  • @Kris.K.
    @Kris.K. Před 5 měsíci

    Hi, i have Grundig tumble dryer. It was working perfectly without any problems. But now won't turn ON. Socket is fine ( tested ). Any idea what can be a problem?

    • @TechnicalChallenger
      @TechnicalChallenger Před 5 měsíci

      Test the plug Test the power supply on PCB Test the fuse on PCB If the fuse on PCB is damaged then check the PCB Resistance or unplug from PCB the Water Pump The Compressor and the Fan .Replace the PCB fuse and see if lights up when you plug it in .If yes then test the fan ,the water pump and the fan .see witch one is blowing the fuse .

    • @Kris.K.
      @Kris.K. Před 5 měsíci

      @@TechnicalChallenger Thank you! Have a nice day👍🏻

  • @hvacgas5292
    @hvacgas5292 Před 6 měsíci

    Great video ,very helpful thank you

  • @cippollino83
    @cippollino83 Před 7 měsíci

    Salut. La fel fac aceeasi meserie. Super interesant. Am incercat sa fac cursuri de plc Cu siemens.

    • @TechnicalChallenger
      @TechnicalChallenger Před 7 měsíci

      Poi e de invatat putin Au o arhitectura si un algoritm mai diferit de alte systeme dar e ok . Eu nu fac programare acuma . Am lasat programare ca mi a mancat viata . M am apucat de managemet in industria farmaceutica

  • @OrionCrazyCarl
    @OrionCrazyCarl Před 7 měsíci

    Where do you hook in to charge the system?

    • @TechnicalChallenger
      @TechnicalChallenger Před 5 měsíci

      You have to cut the compressor seal port and to charge it there . For that you need to atach a valve to the compressor port . Then you use a scale ti charge the system after you vacum it of course .

  • @petrisoralexandru3461
    @petrisoralexandru3461 Před 7 měsíci

    Hello My dryer lost oil from the compressor. Do you know where I can fix?

    • @TechnicalChallenger
      @TechnicalChallenger Před 7 měsíci

      Did the compressor luse the oil or the refrigerant . If you have a heat pump dryer then there is more likely to lose the refrigerant rather than the oil . Unless you break the compressor pipes and and yrn it up side down or run it lond ours with broken pipes .

    • @petrisoralexandru3461
      @petrisoralexandru3461 Před 7 měsíci

      Do you have a email to send the pictures?

    • @TechnicalChallenger
      @TechnicalChallenger Před 7 měsíci

      @@petrisoralexandru3461 Suna ma 07956487538

  • @jeffvandagrif
    @jeffvandagrif Před 7 měsíci

    This was exactly what I was looking for. Thanks!

  • @niranvandenende3254
    @niranvandenende3254 Před 8 měsíci

    Hello my friend, I have a similar heat pump dryer like yours. Mine has the error that it thinks that the water reservoir is full (however this is not the case). I know that it ''thinks'' that the reservoir is full because a sensor down below measures that the container is overfilling. From previous experience i know that most of the time the sensor is dirty so it thinks that the reservoir is full without it being full. Do you know if there is a water level sensor somewhere below? I already cleaned the pump and tested it and the waterpump is working fine!

  • @micahmexswel5712
    @micahmexswel5712 Před 8 měsíci

    Hello sir..i have a question...my question how to reduce humidity in ot room..

  • @gregknutsen673
    @gregknutsen673 Před 9 měsíci

    Thanks for sharing your knowledge

  • @TechnicalChallenger
    @TechnicalChallenger Před 9 měsíci

    Thank you

  • @nickyengle9668
    @nickyengle9668 Před 9 měsíci

    Thks for sharing!

  • @MM-mk6rg
    @MM-mk6rg Před 10 měsíci

    I have a system where the boiler is in the red at about 3bar causing the prv to realise water.the press unit digital screen says 1.1bar and when this kicks in to fill the heating through loss of water it goes from saying 1.1 bar to 2.3bar.what would my problem be.

    • @TechnicalChallenger
      @TechnicalChallenger Před 10 měsíci

      Check the pressure vessel inside the boiler and see if it is faulty or ifnit is correct presurised . See if the temperature is gowing above 90’C

  • @user-vs5fi2vy3h
    @user-vs5fi2vy3h Před 10 měsíci

    Hello What software do you use to design installation Could you recommend the software to design installation for plumbing and heating system domestic and commercial Please Thank you John

  • @user-dl9no4nn6t
    @user-dl9no4nn6t Před 11 měsíci

    Hi. Thank you for the video. I have a query, the positions of the pressure gauges are not right. PG at V12 shows flow and PG at V13 shows return though they are on the same pipeline.

    • @TechnicalChallenger
      @TechnicalChallenger Před 11 měsíci

      They are before and abive the pump . Pump can not have flow in both sides The pump is pushing the liquid and the liquid is returning to the pump . So you have flow and return .

    • @TechnicalChallenger
      @TechnicalChallenger Před 11 měsíci

      On a close circuit you have only ine pipe technicaly speaking and the pressure DP is governed by the Pump and flow restriction only when pump is running and the fluid is on dinamic state . When in static state the DP is also giverned by tue building hight but that is apolying inly in vertical pipes . Every 10m you gain aprox one Bar .

    • @TechnicalChallenger
      @TechnicalChallenger Před 11 měsíci

      Thank you for your observation . I enjoy challanges !

  • @muraliksa
    @muraliksa Před rokem

    - Please explain HTT 930H51 - Burner controller...!!!

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Dear Frind You can attach to the module to PT 100 probes and then the free voltage relays will do the job to any connected circuit . I am not familiar with the module but geting trough its PDF it os stright forward .

  • @samlee4382
    @samlee4382 Před rokem

    Thanks for the effort and sharing

  • @arnelada6216
    @arnelada6216 Před rokem

    Let’s say Pressurization pump kicks in at 0.5 Bar. How about from 1.5 Bar , the operating pressure becomes 0.8 bar only and not reach yet the 0.5 Bar? Does expansion tank also kicks in through gravity and return the expanded water to the system? Or just wait the pressure to 0.5 Bar to make the pump compensate the pressure loss?

  • @christianblake36
    @christianblake36 Před rokem

    This was the best explanation I've heard thank you I appreciate your knowledge

  • @sudhi1013
    @sudhi1013 Před rokem

    Cool .this video is informative

  • @sudhi1013
    @sudhi1013 Před rokem

    Hi pls share the calculation of pressurization unit and its selection

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Dear Sir Pressurisation unit does not require calculation Please look trough my other videos . The heating installation meed calculation And the hight of the installation meed to be considered too

  • @sudhi1013
    @sudhi1013 Před rokem

    Hi good explanation

  • @Ash-sx3is
    @Ash-sx3is Před rokem

    A brilliant set of videos animations and explanations as well as details, in my last job the other engineers wouldn’t tell you any information, they always kept it to themselves. So I have been on this quest to learn, learn more and keep myself up to date. Thanks once again, you are doing a great job.

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Thank you for your good words Life is harsh sometime . I came in UK a while ago and I slept on the streets . I could not speak english . I had no money I have instead a big heart . I put this information on You Tube to help my colleagues and fellow technicians around the world . Thank you again for your words and I hope you will find your way to have a great life .

  • @TechnicalChallenger

    Dear Sir A Programable logic control (PLC) or a Building Management control (BMS) controls many applications from which one of it could be the AHU . PLC or BMS that I personally encounter in my career are Siemens ,Mitsubishi ,Yokogawa ,Trend ,Priva Controller , RDM with submultiple PLCs, Omron , Alan Bradley etc. I just finish level 4 Tia Portal which is Siemens Trainning course . If you want to become a HVAC engineer with programming control knowledge is a hard work . If you want to understand the control philosophy first scroll trough my videos and look to the ones that are about AHUs. Get familiar with control philosophy .I will open a canal online to help as many engineers as I can for free. Please contact me if you need more help or guidance .

  • @democracyforall
    @democracyforall Před rokem

    Nice video, good job but where do we learn about PLC control or this kind PLC control for AHU? Do you know any school etc that teaches this kind PLC programming course for AHU?

  • @joewebb4836
    @joewebb4836 Před rokem

    No latch / jogging circuit.

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Yes you write but in that case I would not a stop button in series .

  • @nickhowell6291
    @nickhowell6291 Před rokem

    Thanks for making this video, we have exactly the same problem, and need to remove the black cover to wash out the condenser. Maybe I'll wait until my wife is away before taking it apart! Thanks again :)

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      If you remove the heat pump cover make sure you will put it back properly . Pay attention to the capillary tube that link the condenser from the evaporator . Also clean the condensate water pump . The internal filter need to be cleaned too. The wires need to be fixed back on their locker .The spinning cylinder will cut them or will rub the insulation and make a short circuit . Inside near the opening door on the lower side there are two parallel metals blades that are sensing the humidity of the clothing.Clean them too . The two parallel blades are short-circuited by the clothing moisture and as long as the PCB will receive the signal back trough the short circuited blades the drier will continue its cycle . Good luck .

    • @russellwalker9177
      @russellwalker9177 Před rokem

      I think this a brilliant video. Also you describe the fancy very well. I can identify with your outlook on managerial positions too. Your English is very good, certainly better than my Hungarian.

    • @russellwalker9177
      @russellwalker9177 Před rokem

      I have acquired a Grundig (Beko/Arcoelectric based) heat pump dryer. I was told “it doesn’t heat” so I intend to do a full strip down and decontamination of all the parts and see what happens. I also plan to check compressor start/run relay and overload (assuming it is an AC compressor like in a standard fridge). I will report back what happens. Thanks again for taking the time to post your thoughts.

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      If you intend to strip it I suggest to check first the dryer running protocol . First try to see if the heat pumping cycle stars . To do that you have to throw a wheat towel or something so the two metal blades that are near the door panel on the frame will be touched by the wheat cloth . The resistive short circuit sent to the PCB will initiate the heat pumping cycle . If you will wait and you will here the compressor buzzing just wait for about 5 minute .The back plate on to the back of the drier where the hot and dryer air moves from the heat pump in to the tumble dryer’s cylinder must get hot . If that is getting hot then you must clean the filters to allow the air to circulate free trough the installation . If that back cover remain cold and you can here the compressor running then the system could lose the refrigerant . Refrigerant can be 134a R600 or you will find the type on the Drier Label. If the heat exchanger is aluminium i can show you how to solder it safely not to melt the pipes . If the compressor does not start then check the Capacitor and the starting relay and the compressor,s SCR. Then have a direct try from a 230VAC power source .I mean a cable connected direct to L N E and see for 10 seconds if the compressor is running . Good look .

  • @wasabnasir9766
    @wasabnasir9766 Před rokem

    Could you send me any video/ drawing for showing the connection between expansion tank, pressurization unit and air separator along with all safety and automation.

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Dear Sir I have more videos about pressurisation units and boiler systems . If you will scroll trough my videos you will find more information . I did not really targeted expansion tanks systems as they are too simple . If you will dean with vented systems that imply expansion tanks make sure the tanks will be fitted at a reasonable hight so there will be enough pressure in to the system Send me your e mail to see what can I do .

  • @wasabnasir9766
    @wasabnasir9766 Před rokem

    Is any different between pressure vessel and expansion tank?

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Yes it is . They are both keeping the pressure in control but they are different features . One in open vented an the other one is closed circuit

  • @maxxam5162
    @maxxam5162 Před rokem

    I have S4560A 1008, starting everything it's working fine, the fire start but it seems cannot detect the fire on sensor connected on pin 13, because after few seconds go in alarm with output on pin 2. If I push reset it start again, but the issue is coming again. Do you have any idea how to fix?

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Check the ionisation probe or the flame quality . If the ionisation probe have an issue then the unit will cut the flame automatically . Try to clean it first Also try to clean the connection of the wire Make shore the earth is well connected

    • @maxxam5162
      @maxxam5162 Před rokem

      How can check the ionisation probe ? Without flame how much be the resistor, and with flame?

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      @@maxxam5162 normally that is half rectified wave . You could see that in the oscilloscope . Did you cleaned the probe and the connections ? Make sure you have the appropriate distance between ionisation probe and earth

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      @@maxxam5162 07956487538

  • @Aaronozard
    @Aaronozard Před rokem

    Your my hero

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Hi Arron I am Mihai John If you are the Arron I know then I am happy that I could help . If not I am happy any way . Kind regards

    • @Aaronozard
      @Aaronozard Před rokem

      @@TechnicalChallenger hello mate- how are you

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      I am ok . Working Hard . Just like u . 07956487538 You can buzz me anytime if you need help . I miss the old times !

    • @Aaronozard
      @Aaronozard Před rokem

      @@TechnicalChallenger will try give you a call tomorrow- when I get 10 minutes 👍

  • @wyatankurtis8679
    @wyatankurtis8679 Před rokem

    🙄 𝓅𝓇𝑜𝓂𝑜𝓈𝓂

  • @purrungas2012
    @purrungas2012 Před rokem

    Top of the line, we need instructors like you in the HVAC industry, thanks a lot for your video

  • @henrybartlett1986
    @henrybartlett1986 Před rokem

    Very good. Thanks for posting.

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      Thank you I wish I was more explicit but english is my second language and I am struggling a bit .

  • @MrRaefel12
    @MrRaefel12 Před rokem

    Would the feed from the pressurisation unit reduce the htg f temperature before it reaches the htg pump?

    • @TechnicalChallenger
      @TechnicalChallenger Před rokem

      The presurisation unit is just to make sure the pressure loss is compensate . The water quantity pushed in to the system should be very small unless there is a nasty leak . Technically speaking the efect of the injected water is not to be considered when talking about temperature .

  • @SHIVAm-mp1dk
    @SHIVAm-mp1dk Před rokem

    Great sir, thanks

  • @rasinmuhammed1762
    @rasinmuhammed1762 Před 2 lety

    Hi Sir, Can I have your contact number please, I want to ask you some doubts about the Imi Pnumatex pressurization unit.

  • @l.d0135
    @l.d0135 Před 2 lety

    Am I right in thinking that using this example we would have to shut and drain down the system in order to check the expansion vessel charge? If so, should there not be another IV and DOV fitted in-between before it reaches the main line?

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 lety

      Yes you are very right . Thank you for that observation . I made this video explaining only the issues that could be generated by the inappropriate settings . Technically speaking you are perfect right . To segregate the system you need valves . Make sense . What can I say . I am privileged to met people with eagle eyes like you . Al my respect.

  • @hasybro4798
    @hasybro4798 Před 2 lety

    Grete

  • @yalchi13
    @yalchi13 Před 2 lety

    Thank you for posting this video bro. Very helpful

  • @elabaisdarhan
    @elabaisdarhan Před 2 lety

    Thank you, sir! A very helpful video. Just by watching the video, I can tell the amount of experiennce this takes. Are there any videos where you are doing design? I mean the calculations and sizing? I'd be happy to watch!

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 lety

      Dear Sir I am not smarter than you The earth is lager than us and plenty for all of us to learn I just want to share my pain with my fellow colleagues.

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 lety

      There i a book about calculations and designs . That is the easy part . The concept is the hardest .I can gave to you some guidance .

    • @hvacdesignsolutions
      @hvacdesignsolutions Před 2 lety

      I think it's pretty obvious he's not a HVAC Designer.

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 lety

      @@hvacdesignsolutions Dear Sir HVAC designer ? Heating ventilation and Air conditioning designer ? I respect your opinion about me . I just try to help as much as I can . I am working in control philosophy but I can help you with the design .the problem os that I do everything for free in my own time and the calculation is irrelevant at this point . Once you will know what you want then I can involve some formulas to help . Gas ,water ,air ,heat load ,air change rates or differential pressure cascade are subject to a complex approach . So could you please tell me how can I help you ? We do not have to be stingy .We can support each other to navigate trough this life .to make it better . 😀

  • @njwareing6408
    @njwareing6408 Před 2 lety

    Does a pressure vessel on the chilled water side work the same as on the hot side +

    • @TechnicalChallenger
      @TechnicalChallenger Před 2 lety

      Good question .Thank you . Because a chiller is usually a cooling system the pressurisation unit will work with an inverted value. When the chiller is off the water is worm and the water pressure in to the system is related directly to the water temperature . You must fill the water circuit on chiller with a maximum pressure allowed by the system . Make sure that you are below the PRV set point . The pressure on the chillers water circuit will drop when the chiller will cool the water . We all know that the water shrink until is freezing .When it is freezing the the water volume is increased again but this is just a basic side explanation . The pressurisation should be set to support the water pressure drop when the water is cooling down . The pressure vessel should be carefully chosen to provide the appropriate elasticity for the system . Technically YES The pressurisation work the same but the pressure in to the system will work in opposite to a boiler system as the water is losing the heat when chiller is working so it is obvious that it will loose the pressure . If the system elasticity is not well calculated the pressurisation will compensate the low pressure when chiller is running and the PRV will eliminate the water when the chiller will rest in night time . If the chiller runs continuously and the variation of temperature is zero then the pressure variation will be zero and the pressure vessel will be good only when the chiller will be turned off . Hope that helps . With respect . Mihai John